DLM-E 3kW & 4kW Series Power Supplies Contents
M362000-01 Rev E xix
LIST OF FIGURES
Figure 2–1. EMI Suppression Filter.................................................................................. 2-2
Figure 2–2. DLM–E Controls, Connectors, and Indicators (5V–80V models) .................. 2-5
Figure 2-3. DLM–E Controls, Connectors, and Indicators (150V–600V models) ............. 2-6
Figure 2–4. Single Load with Local Sensing (Default).....................................................2-12
Figure 2–5. Single Load with Remote Sensing ...............................................................2-13
Figure 2–6. Multiple Loads with Local Sensing...............................................................2-14
Figure 2–7. Multiple Loads with Remote Sensing...........................................................2-14
Figure 3–1. Operating Modes .......................................................................................... 3-2
Figure 3–2. Local Mode Default Configuration................................................................. 3-3
Figure 3–3. J11 Sense Connector.................................................................................... 3-5
Figure 4–1. J3 Connector................................................................................................. 4-3
Figure 4–2. Locating Jumpers, Switch, and Connector.................................................... 4-4
Figure 4–3. Programming Output Voltage, Current Limit and OVP with REM/LOC Switch4-7
Figure 4–4. Programming Output Voltage with a 0–5 VDC or 0–10 VDC Source............ 4-8
Figure 4–5. Programming Output Voltage with a 0–5k Ohm Resistance......................... 4-9
Figure 4–6. Programming Output Current Limit with a 0–5 VDC or 0–10 VDC Source...4-10
Figure 4–7. Programming Output Current Limit with a 0–5k Ohm Resistance................4-11
Figure 4–8. Programming Output Voltage Remotely, Local Control of Current Limit/OVP4-12
Figure 4–9. Programming Output Current Remotely, Local Control of Voltage Limit/OVP4-13
Figure 4–10. Remote Programming of OVP with a 0–5 VDC or 0–10 VDC External Voltage
Source.......................................................................................................4-15
Figure 4–11. Remote Programming of OVP with a 0–5k ohm Resistance......................4-16
Figure 4–12. Using Shutdown with a DC Input (Positive Logic)......................................4-18
Figure 4–13. Using Shutdown with Contact Closure of a Normally OPEN Relay (S1-6 Up)4-
19
Figure 4–14. Using Shutdown with Contact Closure of a Normally OPEN Relay (S1-6 Down)
..................................................................................................................4-19
Figure 4–15. Using Shutdown with Contact Closure of a Normally CLOSED Relay (S1-6 Up)
..................................................................................................................4-19
Figure 4–16. Using Shutdown with Contact Closure of Normally CLOSED Relay (S1-6
Down)........................................................................................................4-20
Figure 4–17. Series Operation of Multiple Supplies........................................................4-22
Figure 4–18. Split Supply Operation of Multiple Supplies (Two Positive Voltages).........4-23
Figure 4–19. Split Supply Operation of Multiple Supplies (Positive–Negative Supply)....4-23
Figure 4–20. Parallel Operation of Multiple Supplies ......................................................4-25
Figure 5–1. Potentiometer Locations ............................................................................... 5-3