Soundchoice PROAudio T-6245 User manual

PUBLIC ADDRESS SYSTEM
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
OPERATION MANUAL
DIGITAL MIXER 6 ZONE
T-6245
MASTER
0
1
2
3
456
7
8
9
10
TREBLEBASS
0
1
2
3
456
7
8
9
10
MUSIC
0
1
2
3
456
7
8
9
10
MICRO
REC
STOP
PLAYACTIVEMIC
MESSAGE RECORDER
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6 TUNERCDTAPE OUTPUT LEVEL POWER
ON
T-6245
DIGITAL MIXER 6 ZONE
0
+5
-5
+4
+3
+2
+1
-4
-3
-2
-1 0
+5
-5
+4
+3
+2
+1
-4
-3
-2
-1
0
1
2
3
456
7
8
9
10 0
1
2
3
456
7
8
9
10
OFF

TABLE OF CONTENTS
2
T-6235
1. SAFETY PRECAUTIONS .......................................................................................3
2. GENERAL DESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel ..............................................................................................................6
4.2 Rear Panel..............................................................................................................7
5. CONNECTIONS .......................................................................................................8
6. APPLICATIONS .......................................................................................................9
7.ADDRESS SET ........................................................................................................11
8.BLOCK DIAGRAM ..................................................................................................13
9.SPECIFICATIONS ..................................................................................................14
10.DIMENSIONAL DIAGRAM ..................................................................................15
V1.0-2009-04-14

Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer.
Make no further attempt to operate the unit in this
condition as this may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
SOUND CHOICE
SOUND CHOICE
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
3
SAFETY PRECAUTIONS
T-6245

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
sw hed on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the
cleaning. If dust is allowed to accumulate in the
unit over a long period of time, a fire or damage
to the unit may result.
itc
SOUND CHOICE
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Sw h off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
itc
4
SAFETY PRECAUTIONS
T-6245

1. 6 zones sources selection and control function.
2. 6 zones alarming sources selection control with 24VDC output.
3. Build-in 3 record storage, can setting freely to play.
4. Build-in chime generator.
5. 3 CH sources input:1 CH MIC input, build-in optional control, build-in optional control+48V phantom power.
6. 3 CH preamp output :MUSIC,MUSIC PAGE,PAGE pre output.
7. 3 Classes priority.
a:Build-in record message (1and 2) Priority: TUNER,CD,MP3.
b:Build-in chime priority: record message(1and 2): TUNER,CD,MP3.
c: Select paging MIC override all audio sources.
9. Build-in voltage output indicator.
10.485 COM port.
3. FEATURES
T-6245 a digital mixer can provide an ideal public address solution from small to big places such us
mosques,schools,hotelsand factoriesto train stadium and air stations.
is 6 zone
2. GENERAL DESCRIPTION
5T-6245

4.1 FRONT PANEL
6
1. ZONE(1~6)
N.6 buttons for music selection In the 6 different zones
2. AUDIO
N.3 key sw h for input channel selection:
Tuner CD Tape
3. OUTPUT LEVEL
Power level indicator
4. POWER
Power indicator
5. POWER SW H
On top of the opening Power
Press the end, power shut down
6. MASTER
Master level control
7. TREBLE
Adjust treble response. Rotate clockwise to increase
treble output and anticlockwise to reduce it.
8. BASS
Adjust bass response. Rotate clockwise to increase
bass output and anticlockwise to reduce it.
itc
ITC
4. NOMENCLATURE AND FUNCTIONS
9. MUSIC
Music volume control
10.MICRO
MICRO volume control
11.REC
Key switch Rec message
Three messages of 60 seconds each
could be recorded; for message selection
see sw h(13) on rear Panel.
12.STOP
Key sw h stop message
13.PLAY
Key sw h play message for manual activation
14.ACTIVE
Indicator play message
15.MIC
Internal microphone for message recor-
ding
itc
itc
itc
MASTER
0
1
2
3
456
7
8
9
10
TREBLEBASS
0
1
2
3
456
7
8
9
10
MUSIC
0
1
2
3
456
7
8
9
10
MICRO
REC
STOP
PLAYACTIVEMIC
MESSAGE RECORDER
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6 TUNERCDTAPE OUTPUT LEVEL POWER
T-6245
DIGITAL MIXER 6 ZONE
0
+5
-5
+4
+3
+2
+1
-4
-3
-2
-1 0
+5
-5
+4
+3
+2
+1
-4
-3
-2
-1
ON
OFF
1342
5
6
7
891011121314
15
T-6245

16.AC INLET
Connect to the supplied power cord.
17.OUT COMMON RELE MUSIC ZONE
18.OUT POWER CONTROL RELE
19.OUT MIX SIGNAL MUSIC VOICE
20.OUT SIGNAL MUSIC
21.OUT SIGNAL VOICE
22.CONTACT PLAY MESSAGE 1 OR 2
The third message is activated by
Microphone basedirectly.
23. SW H REC MESSAGE:
OFF, 1, 2, 3 .
This is used to select the message
to record
24. SWS H MESSAGE 1
TIME / CONTINUOS
- 1 TIME:
The recorded message plays only
Once
- CONTINUOS:
The recorded message plays
continuously till the message
contact is kept closed.
25. SW H MICROPHONE ALARM /
NORMAL THE MIXER COULD WORK
WITHOUT MICROPHONE CONSOLE
BMD6; ASIMPLE MICROPHONE BASE
WITH PRIORITY CONTACT COULD BE
CONNECTED TO XLR MICROPHONE
INPUT).
ITC
ITC
ITC
NOMENCLATURE AND FUCTIONS
7
4.2 REAR PANEL
16 1817
38
PRIORITY
TAPE CD TUNER MICRO
CONSOL
~240V/50Hz
T1AL250V
GAIN GAIN CONSOL
VOLUME
VOLUME
CHIME
OFF
12
3
REC
MESSAGE
1 TIME
CONTINUOS
MESSAGE
NORMAL
ALARM VOL.PLAY
MESSAGE
VOL.REC
MIC
OPEN RELE OUT ZONE 1 OUT ZONE 2 OUT ZONE 3 OUT ZONE 4 OUT ZONE 5 OUT ZONE 6 OUT
COM NO1 NO2
PLAY MESSAGE
+1
RELE ZONE CONSOL OUT MIX MUSIC-PAGE OUT MUSIC OUT PAGE OUTIN COM ZONE
+48V
PHANTOM
+2
+3
+4
+5
+6
36
19 20 21 22 23 24 25 26 27 28 29 30
37 35 34 33 32 31
- ALARM:
The voice is simultaneously
distributed in all the 6 zones
- NORMAL:
The voice is distributed only in the
zone selected with front panel
Buttons
26. VOLUME REC MESSAGE
27. VOLUME PLAY MESSAGE
28. PHANTOM POWER SELECT SW H
29. CHIME VOLUME CONTROL
30. PRIORITY CONTROL PORT FOR BGM AND
INTERNAL CHIME.
31. INPUT RJ45 CONSOL
Max 6 microphone bases in
Parallel
32. VOLUME INPUT CONSOL
33. CONSOL GAIN CONTROL
34. MICROPHONE GAIN CONTROL
35. MICROPHONE INPUT XLR BALANCED
36. AUDIO SOURCE INTERFACE
37. OUT ZONE (1~6)
38. OUT CONTACE OPEN RELE ZONE
ITC
T-6245
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM

5. CONNECTIONS
NETWORK CONNECTION LINE
78
A
123456
NET PRODUCTION LINE METHOD
Note: Network lines must adopt the five categories of twisted-pair with double-layer
shielding, RJ45 connectors must be used with shielded connector.
B: 1 Blue 2 White Blue 3 Brown 4 White Brown 5 Orange 6 White Orange
7 Green 8 White Green
A: 1 Blue 2 White Blue 3 Brown 4 White Brown 5 Orange 6 White Orange
7 Green 8 White Green
Paging Station
Digital Mixer 6 zone
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
8
12345678
B
A
B
Network Line
~240V/50Hz
T1AL250V
OPEN RELE OUT ZONE 1 OUT ZONE 2 OUT ZONE 3 OUT ZONE 4 OUT ZONE 5 OUT ZONE 6 OUT
COM NO1 NO2
PLAY MESSAGE
+1
RELE ZONE CONSOL OUT MIX MUSIC-PAGE OUT MUSIC OUT PAGE OUTIN COM ZONE
+2
+3
+4
+5
+6
PRIORITY
TAPE CD TUNER MICRO
CONSOL
GAIN GAIN CONSOL
VOLUME
VOLUME
CHIME
OFF
12
3
REC
MESSAGE
1 TIME
CONTINUOS
MESSAGE
NORMAL
ALARM VOL.PLAY
MESSAGE
VOL.REC
MIC
+48V
PHANTOM
T-6245
RISKOF ELECTRIC SHOCK
DONOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PASQUVRIR
AVIS:
SERIAL NO:
PUBLICADDRESS SYSTEM
LINK OUT
AB

6. APPLICATIONS
9
1 amplifier for music 1 amplifier for voice for 6 zone
Voice
Music
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
Compact disc
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
ZONE 6 OUT
NO2
PLAY MESSAGE
PRIORITY
TAPE CD TUNER MICRO
CONSOL
GAIN GAIN CONSOL
VOLUME
VOLUME
CHIME
OFF
12
3
REC
MESSAGE
1 TIME
CONTINUOS
MESSAGE
NORMAL
ALARM VOL.PLAY
MESSAGE
VOL.REC
MIC
+48V
PHANTOM
~240V/50Hz
T1AL250V
OPEN RELE OUT ZONE 1 OUT ZONE 2 OUT ZONE 3 OUT ZONE 4 OUT ZONE 5 OUT
COM NO1
+1
RELE ZONE CONSOL OUT MIX MUSIC-PAGE OUT MUSIC OUT PAGE OUTIN COM ZONE
+2
+3
+4
+5
+6
T-6245
RISKOF ELECTRIC SHOCK
DONOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PASQUVRIR
AVIS:
SERIAL NO:
PUBLICADDRESS SYSTEM
LINK OUT
LINK OUT
LINK OUT
LINK OUT
LINK OUT
LINK OUT
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~240V/50Hz
FUSE
T7AL250V
POWER FUSE
350W
500W
650W
T8AL250V
T10AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~240V/50Hz
FUSE
T7AL250V
POWER FUSE
350W
500W
650W
T8AL250V
T10AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:

10
T-6245
APPLICATIONS
6 amplifier one for each zone
Compact disc
Zone 6
Zone 5
Zone 4
Zone 3
Zone 2
Zone 1
ZONE 6 OUT
NO2
PLAY MESSAGE
PRIORITY
TAPE CD TUNER MICRO
CONSOL
GAIN GAIN CONSOL
VOLUME
VOLUME
CHIME
OFF
12
3
REC
MESSAGE
1 TIME
CONTINUOS
MESSAGE
NORMAL
ALARM VOL.PLAY
MESSAGE
VOL.REC
MIC
+48V
PHANTOM
~240V/50Hz
T1AL250V
OPEN RELE OUT ZONE 1 OUT ZONE 2 OUT ZONE 3 OUT ZONE 4 OUT ZONE 5 OUT
COM NO1
+1
RELE ZONE CONSOLOUT MIX MUSIC-PAGE OUT MUSIC OUT PAGE OUTIN COM ZONE
+2
+3
+4
+5
+6
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLICADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
POWER
24VDC
-10 +10 010
-10 +10
CHIME
VOLUME TREBLE BASS VOLUME ID CONSOL
LINE IN
010
1
2
3
1 GND
2 GND
3+24DC
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLIC ADDRESS SYSTEM
LINK OUT
LINK OUT
LINK OUT
LINK OUT
LINK OUT
LINK OUT
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~240V/50Hz
FUSE
T7AL250V
POWER FUSE
350W
500W
650W
T8AL250V
T10AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~240V/50Hz
FUSE
T7AL250V
POWER FUSE
350W
500W
650W
T8AL250V
T10AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~240V/50Hz
FUSE
T7AL250V
POWER FUSE
350W
500W
650W
T8AL250V
T10AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~240V/50Hz
FUSE
T7AL250V
POWER FUSE
350W
500W
650W
T8AL250V
T10AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~240V/50Hz
FUSE
T7AL250V
POWER FUSE
350W
500W
650W
T8AL250V
T10AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:
INPUTS
LINK
GND
LIFT
100V 70V 4~16 COM
OUTPUT
~240V/50Hz
FUSE
T7AL250V
POWER FUSE
350W
500W
650W
T8AL250V
T10AL250V
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
PUBLIC ADDRESS SYSTEM
SERIAL NO:

7.ADDRESS SET
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
ADDRESS DEFINITION
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ADDRESS DEFINITION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ID CONSOL ADDRESS SET
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
11 T-6245

ADDRESS SET
ADDRESS DEFINITION
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
ID CONSOL ADDRESS SET
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
ADDRESS DEFINITION
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
12
T-6245

VOLUME
CHIME
VOLUME
M1
1
8
CONSOL
GND
POWER
+24V
MAX485
CONTROL
SIGNAL
M1
NORMAL
ALARM
PRIORITY
VCC
GAIN
VOLUME
A 2
+48V
PHANTOM
MICRO
CHIME
SIGNAL MESSAGE 1 - 2 - 3
BASS
A 3
CONTROL
A 5
MUTE 4
ON/OFF
MUTE 4
A 4
VOLUME
MUSIC
VOLUME
MESSAGE
PLAY
MESSAGE 3
VOLUME
REC
CD
TAPE
TUNER
MIC
MUTE 2
A 1
MUTE 1
CONTROL
REC/PLAY
MESSAGE
ZONE 3
ZONE 6
ZONE 5
ZONE 4
ZONE 2
ZONE 1
TREBLE
MUTE 3
CONTROL ISD4003
REC
OUT VCC
PLAY
MESSAGE 1
PLAY
MESSAGE 2
PLAY STOP
MCU
OFF
123
1 TIME
CONTINUOS
RL1B
RL2B
OUT +24 V zone 4
OUT +24 V zone 3
OUT +24 V zone 2
OUT +24 V zone 1
OUT -24 V com
OUT +24 V zone 6
OUT +24 V zone 5
OUT RELE'
ZONE CONSOL
CONTACT (15)
COLD
GND
HOT
GND
COLD
COLD
COLD
COLD
HOT
HOT
HOT
GND
GND
GND
HOT
BALANCED
RL1A
RL2A
OUT ZONE 1
CONTACT (21)
OUT OPEN RELE'
CONTACT (20)
OUT PAGE
0 dB
CONTACT (19)
OUT ZONE 2
CONTACT (21)
OUT ZONE 3
CONTACT (21)
LEVEL OUTPUT (VU METER)
RL3B
RL4B
RL5B
RL6B
GND
COLD
GND
HOT
COLD
COLD
COLD
HOT
GND
HOT
GND
HOT
RL3A
RL4A
RL5A
RL6A
OUT ZONE 4
CONTACT (21)
OUT ZONE 5
CONTACT (21)
OUT ZONE 6
CONTACT (21)
IN COM ZONE
CONTACT (16)
IN COM ZONE
CONTACT (16)
COLD
GND
HOT
GND
COLD
HOT
BALANCED
BALANCED
OUT MUSIC
0 dB
CONTACT (18)
OUT MIX MUSIC-PAGE
0 dB
CONTACT (17)
7. BLOCK DIAGRAM
13 T-6245

T-6245
Model
1 Mircophone input
Sensitivity -50 / -2 dB 2, 5 / 500 mV
S/N ratio >68dB
Frequency response 100/17.000Hz(-3dB)
Phantom power 48V
3 Auxiliaryinputs
Tuner and Tape input sensitivity /
impedance 200 mV / 47 Kohm
500 mV / 47 Kohm
>90 dB
40/20.000Hz(-3dB)
CD input sensitivity / impedance
Frequency response
S/N ratio
Control
Bass 12dB
12dB
2 tone active for contact free in
priority and BGM
>0.1%
Treble
Normal distortion
Chime
Operating condition
Main power supply 240 VAC 50 Hz
484X322X88
6
Dimension(mm)
Max number of microphone bases
Weight 6.58Kg
Consol input
Sensitivity -50 / -2 dB 2, 5 / 500 mV
S/N ratio >68dB
Frequency response 100/17.000Hz(-3dB)
8. SPECIFICATIONS
14
T-6245

9. DIMENSIONAL DIAGRAM
100
Over
100
Over
Over
100
UNIT :mm
UNIT :mm
6
84
84
25
297
291
88
94
436
484
PRIORITY
TAPE CD TUNER MICRO
CONSOL
~240V/50Hz
T1AL250V
GAIN GAIN CONSOL
VOLUME
VOLUME
CHIME
OFF
12
3
REC
MESSAGE
1 TIME
CONTINUOS
MESSAGE
NORMAL
ALARM VOL.PLAY
MESSAGE
VOL.REC
MIC
OPEN RELE OUT ZONE 1 OUT ZONE 2 OUT ZONE 3 OUT ZONE 4 OUT ZONE 5 OUT ZONE 6 OUT
COM NO1 NO2
PLAY MESSAGE
+1
RELE ZONE CONSO OUTLMIX MUSIC-PAGE OUT MUSIC OUT PAGE OUTIN COM ZONE
+48V
PHANTOM
+2
+3
+4
+5
+6
MASTER
0
1
2
3
456
7
8
9
10
TREBLEBASS
0
1
2
3
456
7
8
9
10
MUSIC
0
1
2
3
456
7
8
9
10
MICRO
REC
STOP
PLAYACTIVEMIC
MESSAGE RECORDER
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6 TUNERCDTAPE OUTPUT LEVEL POWER
T-6245
DIGITAL MIXER 6 ZONE
0
+5
-5
+4
+3
+2
+1
-4
-3
-2
-1 0
+5
-5
+4
+3
+2
+1
-4
-3
-2
-1
ON
OFF
MASTER
0
1
2
3
456
7
8
9
10
TREBLEBASS
0
1
2
3
456
7
8
9
10
MUSIC
0
1
2
3
456
7
8
9
10
MICRO
REC
STOP
PLAYACTIVEMIC
MESSAGE RECORDER
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6 TUNERCDTAPE OUTPUT LEVEL POWER
T-6245
DIGITAL MIXER 6 ZONE
0
+5
-5
+4
+3
+2
+1
-4
-3
-2
-1 0
+5
-5
+4
+3
+2
+1
-4
-3
-2
-1
ON
OFF
15 T-6245
RISKOF ELECTRIC SHOCK
DONOT OPEN
RISQUE DE CHOC ELECTRICUS
-NE PAS QUVRIR
AVIS:
SERIAL NO:
PUBLICADDRESS SYSTEM

PUBLIC ADDRESS SYSTEM
2009-04 Version1.0
Table of contents