Soundoff Signal Nergy BluePrint ENGCP18001 User manual

EVCS_Control Panel_ENGCP18001 5.16
1.800.338.7337 / www.soundoffsignal.com
NOTICE:
Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.
Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at
www.soundoffsignal.com/sales-support. If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800338.7337 (press #4 to skip the
automated message). Questions or comments that do not require immediate attention may be emailed to [email protected].
SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
6.9”W
3.5”H
Arrow Indication
ON (Red) when
function is active
*Buttons are Backlit
CONTROL PANEL
PART NUMBER: ENGCP18001
The Control Panel features 8 (eight) auxiliary buttons for one-touch programming and a three-position slide switch to
allow convenient switching for the most frequently used warning modes.
It also features an eight-second buzzer alert to notify users that the level or auxiliary buttons are activated and
dimmable green LED backlighting.
.
Tech Specs
nERGY Control System
Control Panel
Input Voltage: 10-16Vdc (Negative Ground)
Sleep Current: 8 mA
Inputs: 1x 3pin MIC Input
Reverse Polarity Protection: Protected
Transient Protection: Protected
High Voltage Protection: Protected
Low Voltage Protection: Protected
Operating Temp: -40˚C to + 65˚C
Dimensions: 6.9”H x 3.5”Wx 1.2”D
Weight, Boxed: 1.3lb.
Weight, Device Only: 1.1lb
The control panel is not waterproof. Install in a protected location away from excessive
heat and moisture.
* SIREN AUDIO BUTTON ACTIVATED
(EXCEPT RADIO REBROADCAST)
STANDBY SPKR 1 INDICATOR SPKR 2 INDICATOR CONDITION
FLASHING ON ON OVER-TEMPERATURE, (380R ONLY)
FLASHING OFF ON UNDER-VOLTAGE
FLASHING ON OFF OVER-VOLTAGE
FLASHING FLASHING - COMM FAULT - RELAY
FLASHING - FLASHING COMM FAULT - AMP
FLASHING FLASHING FLASHING COMM FAULT -CENTRAL CONTROLLER
ON - - STANDBY MODE
*OFF ON - SPKR 1 IS ACTIVE
*OFF - ON SPKR 2 IS ACTIVE
*OFF OFF - SPKR 1 IS NON-FUNCTIONING
*OFF - OFF SPKR 2 IS NON-FUNCTIONING
SIREN AMPLIFIER DIAGNOSTIC INDICATORS:
•HIGH CURRENT interconnects must be properly terminated. Poor crimp quality can cause heat
build-up and re. Follow crimp connector manufacturer instructions.
•DO NOT install this product or route any wires in the Air Bag Deployment Zone. Refer to vehicle
Owner’s Manual for deployment zones.
•Do NOT use system to disconnect headlights, brake lights or other safety equipment.
•Unit may become hot to touch during normal operation.
•Failure to properly install connectors, fuses or wiring may cause vehicle failure or re.
•Installation must only be performed by trained technician. Installer must determine vehicle wiring
conguration and proper integration of system.
•Use proper wire gauge. All power wires connecting to positive (+) or negative (-) battery terminal
or local chassis ground (-) must be sized to supply at least 125% of max. current and properly fused at
power source.
•Install protective grommets when routing wire through rewall or metal.
WARNING
1

EVCS_Control Panel_ENGCP18001 5.16
1.800.338.7337 / www.soundoffsignal.com
NOTICE:
Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.
Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at
www.soundoffsignal.com/sales-support. If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800338.7337 (press #4 to skip the
automated message). Questions or comments that do not require immediate attention may be emailed to [email protected].
SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
NOTE:
For All programming modes: Momentarily depress Radio
Rebroadcast push-button to exit.
To hear samples of all the tones available go to www.
soundoffsignal.com website.
INPUT SETTINGS:
1. Press and Hold Auxiliary Button 1 and 3 until slide switch #3 LED
ashes.
*1. Park Kill Polarity Mode: Determines what voltage
level will activate park kill functions.
ON = activated when +V is applied to Park
Kill input wire.
OFF = activated when Ground is applied to
Park Kill input wire.
LEGEND:
ON
OFF
GRAYED AREAS DENOTE FACTORY DEFAULTS
2
DON’T CARE
*2. Horn Ring Polarity Mode: Determines what voltage level
will activate Horn Ring functions.
ON = activated when +V is
applied to Horn Ring input wire
OFF = activated when Ground is applied
to Horn Ring input wire
3. Tone Push-button: Determines if the Tone Push-button
activation will allow a siren tone to be produced.
ON = Tone Push-button Enabled
OFF = Tone Push-button Disabled
*= Setting can be selected in bluePRINT conguration
application
Setting in conguration application will override
control panel displayed setting.
** =Setting can be overidden by bluePRINT
conguration application if “on” setting is set on
Control Panel
Slide Switch LEDs
Arrow Control LEDs
AUXILLARY BUTTON #s
1 2 3 4
5 6 7 8
Diagnostic LED’s
PROGRAMMING MANUAL
**5. Park Kill Latch: When Park Kill input is triggered,
determines how siren tone proceeds once park kill input
is no longer active. Set to enabled for software control.
ON = Tone remains disabled until
operator selects other tone
OFF = Tone resumes once Park Kill input
is no longer active
**4. Level 3 tone activation: Determines when the siren tone
push-buttons on control panel are enabled.
ON = Tone push-buttons always enabled
OFF = Tone push-buttons only enabled
when slide switch is in position #3.

EVCS_Control Panel_ENGCP18001 5.16
1.800.338.7337 / www.soundoffsignal.com
HIGH
LOW 2
65
3
7
4
*Setting PA Volume:
1. Press and Hold Auxiliary Push-Button “1” and “2” until slide switch
#2 and #3 indicator LED ashes.
2. Depress and hold PA switch on microphone and press Push-button
“1”-“8” depending on volume required. When correct
volume is determined, press Radio Rebroadcast and the
volume setting will be permanently stored.
ALTERNATE HORN RING CONTROL
OPTION 1 OPTION 2
STANDBY OEM HORN OEM HORN
LEVEL 1 OEM HORN OEM HORN
LEVEL 2 Air Horn or Wail
Button Tone while
Pressed *
Tap to Turn On Warning Tone,
Tap again to Change Warning
Tone. Press and Hold for Air
Horn Tone
LEVEL 3 Tap to turn ON
Warning Tone, Tap
again to change
Warning Tone. Press
and Hold for Air Horn
Tone
TONE
SWITCH OFF:
Air Horn Tone
or Wail Button
Tone while
Pressed *
TONE
SWITCH ON:
Tap to change
Warning Tone,
Press and Hold
for Air Horn
Tone
BACKLIGHT INTENSITY:
While pressing RADIO REBROADCAST BUTTON,
press Auxiliary Button 1-8 to adjust backlight intensity.
Button 1 = Lowest intensity, Button 8 = Highest intensity.
Backlight must be enabled by the Gray wire on CN6.
3. GUN LOCK SECURITY:
ON = Operator must press Standby button
within 1 second after pressing 8
second time delay button to active
switch
OFF = 8 second time delay switch is
activated immediately when
pressed
3
SLIDE SWITCH SETTINGS
MODE
RELAY
OUTPUT
#1
RELAY
OUTPUT
#2
RELAY
OUTPUT
#3
SLIDE
SWITCH
POSITION
1AUXILIARY PUSH-BUTTON ‘1’
IS SELECTED
1
2
3
2AUXILIARY PUSH-BUTTON ‘2’
IS SELECTED
1
2
3
3AUXILIARY PUSH-BUTTON ‘3’
IS SELECTED
1
2
3
SLIDE SWITCH SETTINGS:
1. Press and hold Auxiliary Push-Button “1” and “4” until
slide switch #2 indicator LED ashes.
2. Press Auxiliary Push-Button “1”, “2” or “3” depending on
which conguration for the slide switch is required.
PROGRAMMING MANUAL
*Set in “OTHER MODES” 6. Horn Ring Standby Tone
ALTERNATE MODES:
1. Press and Hold Auxiliary Push-Button “2” and “6” until Slide
Switch indicator #1 and indicator #2 LED ashes.
1. Alternate Horn Ring control: Custom operation of vehicle
horn when pressed. Refer to gure below for details.
ON = Enabled
OFF = Disabled
2. Alternate Horn Ring control option: (Alternate Horn Ring
Control must be enabled). Custom operation of vehicle
horn when pressed. Refer to gure below for details.
ON = Option 2
OFF = Option 1
OTHER MODES:
1. Press and Hold Auxiliary Button “1” and “5” until slide switch
#1 and #3 indicator LED ashes.
1. Buzzer: Audible tone from control panel whenever operator
presses push-button or changes position of slide/rotary
switch
ON = Buzzer enabled
OFF = Buzzer disabled
2. 8 Second Buzzer Alert: Provides audible beep whenever any
auxiliary switches are ON or level 1, 2, or 3 is active.
ON = Enabled
OFF = Disabled
3. Air Horn Button Output Channels
ON =In standby mode, Air Horn tone is
output on Spkr A & B. When Warning
Tone is Active, Warning Tone continues
on Spkr A & Air Horn Button Tone is
output on Spkr B
OFF =Air Horn Button Tone always
produced on Spkr A & B

EVCS_Control Panel_ENGCP18001 5.16
1.800.338.7337 / www.soundoffsignal.com
AUXILIARY SWITCH SETTINGS:
Refer to Figure at bottom center for Button and LED locations and
terminology
1. Press and Hold Auxiliary Button #1 and #8 until slide switch #1 LED
ashes.
2. Press the button which setting is going to be viewed/changed 1 time.
3. Monitor the 5 LED’s for the arrow controller to determine setting
- *Arrow Controller (Left, Right, Center, OFF), Dual Output; 1 & 9
- Alternate Action Switch (Press ON / Press OFF)
- Momentary Action Switch (ON only when depressed)
- 8 Second ON Time (ON for 8 seconds when depressed)
- Level 1 Disable (Turns OFF Level 1 Output)
- Level 2 Disable (Turns OFF Level 2 Output)
- Left Arrow, Single Output
- Right Arrow, Single Output
- Center Arrow, Single Output
- Warning Bar Output
4. Press and release button until desired mode is selected.
5. Continue steps 2-3 for any other buttons that need to be programmed.
Denotes Factory Default Setting
*Can only be programmed to one button
and will disable Left, Right and Center
Arrow Single Outputs if they are used.
Default Settings:
Button #1: Arrow Controller
Button #2-7: Alternate Action Switch
Button #8: 8 Second ON Time
4
Auxiliary Push-button to Slide switch mapping programming:
Allows the operator to have the siren automatically turn on
auxiliary push-buttons based on the position of the slide
switch.
If an auxiliary push-button is programmed to turn ON when the
slide switch position is selected, the auxiliary push-button will
turn OFF when the programmed slide switch position is no
longer selected.
The operator can override the automatic activation of the auxiliary
push-button by momentarily pressing the auxiliary push-
button.
To program:
1. Press auxiliary push-buttons ‘4’ and ‘5’ for 2 seconds until
Radio Rebroadcast indicator LED ashes.
2. Move slide switch to desired position.
3. Press auxiliary push-buttons ‘1’ – ‘8’ as required.
4. Repeat steps 2 and 3 for other slide switch positions as
required.
5. Place appropriate button legend over activity indicator for each
programmed button.
LED ON Auxiliary push-button will automatically turn
ON when level switch position is activated.
LED OFF
Auxiliary push-button will not automatically
turn ON when level switch position is
activated.
*TONE PROGRAMMING:
1. Press and hold “buttons” “2” and “7” for 2 seconds until Slide
switch LED’S 1,2, and 3 ash
2. Press tone button to be programmed (Wail, Yelp, Tone,
Manual, or Horn). Auxiliary button 1 = HORN, button 2 =
MANUAL
3. Auxiliary buttons 5-8 will determine which tone is to be played
when the user presses the button.
4. Repeat steps 2 and 3 for each tone button
5. Press Radio Rebroadcast button to exit programming mode
MANUAL BUTTON TONE DURATION
MOMENTARY: When played solo
LATCHED: When played over other tones.
STANDBY SPKR 1 INDICATOR SPKR 2 INDICATOR CONDITION
FLASHING ON ON OVER-TEMPERATURE, (380R ONLY)
FLASHING OFF ON UNDER-VOLTAGE
FLASHING ON OFF OVER-VOLTAGE
FLASHING FLASHING - COMM FAULT - RELAY
FLASHING - FLASHING COMM FAULT - AMP
FLASHING FLASHING FLASHING COMM FAULT -RELAY AND AMP
ON - - STANDBY MODE
*OFF ON - SPKR 1 IS ACTIVE
*OFF - ON SPKR 2 IS ACTIVE
*OFF OFF - SPKR 1 IS NON-FUNCTIONING
*OFF - OFF SPKR 2 IS NON-FUNCTIONING
SIREN AMPLIFIER DIAGNOSTIC INDICATORS:
* SIREN AUDIO BUTTON ACTIVATED
(EXCEPT RADIO REBROADCAST)
PROGRAMMING MANUAL

EVCS_Control Panel_ENGCP18001 5.16
1.800.338.7337 / www.soundoffsignal.com
NOTICE:
Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.
Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at
www.soundoffsignal.com/sales-support. If you have questions regarding this product, contact Technical Services, Monday - Friday, 8 a.m. to 5 p.m. at 1.800338.7337 (press #4 to skip the
automated message). Questions or comments that do not require immediate attention may be emailed to [email protected].
SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.
BUTTON
#6
BUTTON
#7
BUTTON
#8
SPKR A SPKR B
OFF OFF OFF WAIL 1 WAIL 1
OFF OFF ON WAIL 2 WAIL 2
OFF ON OFF WAIL 1 WAIL 2
OFF ON ON WAIL 1 YELP 1
ON OFF OFF WAIL 1 ALERT A
ON OFF ON WAIL 1 HiLo
ON ON OFF WAIL 2 SUPER HiLo
ON ON ON WAIL 2 PIERCER
WAIL BUTTON
BUTTON
#6
BUTTON
#7
BUTTON
#8
SPKR A SPKR B
OFF OFF OFF YELP 1 YELP 1
OFF OFF ON YELP 2 YELP 2
OFF ON OFF YELP 1 YELP 2
OFF ON ON YELP 1 WAIL 1
ON OFF OFF YELP 1 PIERCER
ON OFF ON YELP 1 HiLo
ON ON OFF YELP 2 SUPER HiLo
ON ON ON YELP 2 PIERCER
YELP BUTTON
BUTTON
#5
BUTTON
#6
BUTTON
#7
BUTTON
#8
SPKR A SPKR B
OFF OFF OFF OFF TONE
SCROLL*
TONE
SCROLL*
OFF OFF OFF ON PIERCER PIERCER
OFF OFF ON OFF HiLo HiLo
OFF OFF ON ON SUPER HiLo SUPER HiLo
OFF ON OFF OFF ALERT A ALERT A
OFF ON OFF ON ALERT A HiLo
OFF ON ON OFF ALERT A SUPER HiLo
OFF ON ON ON HiLo SUPER HiLo
ON OFF OFF OFF HiLo PIERCER
ON OFF OFF ON ALERT A ALERT B
ON OFF ON OFF PIERCER YELP 1
ON OFF ON ON PIERCER WAIL 1
ON ON OFF OFF SUPER HiLo PIERCER
ON ON OFF ON WAIL 1 WAIL 2
ON ON ON OFF YELP 1 YELP 2
ON ON ON ON WAIL 1 YELP 1
TONE BUTTON
BUTTON
#5
BUTTON
#6
BUTTON
#7
BUTTON
#8
SPKR A SPKR B
OFF OFF OFF OFF HORN 1 HORN 1
OFF OFF OFF ON HORN 2 HORN 2
OFF OFF ON OFF HORN 3 HORN 3
OFF OFF ON ON HORN 4 HORN 4
OFF ON OFF OFF HORN 1 HORN 2
OFF ON OFF ON HORN 1 HORN 3
OFF ON ON OFF HORN 4 HORN 1
OFF ON ON ON HORN 2 HORN 3
ON OFF OFF OFF HORN 2 HORN 4
ON OFF OFF ON HORN 3 HORN 4
ON OFF ON OFF HORN 1 WAIL 1
ON OFF ON ON HORN 1 YELP 1
ON ON OFF OFF HORN 1 PIERCER
ON ON OFF ON HORN 2 YELP 1
ON ON ON OFF HORN 3 YELP 1
ON ON ON ON HORN 4 SUPER
HiLo
HORN BUTTON
BUTTON
#6
BUTTON
#7
BUTTON
#8
SPKR A/B
OFF OFF OFF WAIL 1
FREQUENCY DECREASE WHEN
RELEASED
OFF OFF ON WAIL 1
IMMEDIATE OFF WHEN RELEASED
OFF ON OFF YELP 1
OFF ON ON PIERCER
ON OFF OFF ALERT A
ON OFF ON HiLo
ON ON OFF SUPER HiLo
ON ON ON WAIL 1
IMMEDIATE OFF WHEN RELEASED
MANUAL BUTTON (SOLO PLAY ONLY)
Denotes Factory Default Setting
SPKR A SPKR B
WAIL 1 WAIL 2
WAIL 2 YELP 1
YELP 1 YELP 2
YELP 2 PIERCER
PIERCER ALERT A
ALERT A WAIL 1
*TONE SCROLL
5
PROGRAMMING MANUAL
Table of contents
Other Soundoff Signal Control Panel manuals
Popular Control Panel manuals by other brands

Micro Air Corporation
Micro Air Corporation FX2-CHILLER Operation manual

GE
GE NetworX NX-6 Installation and startup

Teletek electronics
Teletek electronics CA62 Installation and programming manual

Elite
Elite AP-3000 installation guide

HIK VISION
HIK VISION DS-19A Series manual

C & K Systems
C & K Systems Securit 802 Features