Source S16WLED-WH Maintenance and service guide

Product Information Sheet
COMMISSION DELEGATED REGULATION (EU) 2019/2015 with regard to energy labelling of light
sources
Supplier's name or trade mark: Source
Supplier's address: SGD Limited, Unit 7/8 Ashbourne Business Centre, Ballybin Road, Ashbourne,
Co. Meath. A84 YP58. Ireland.
Model identifier: S16WLED WH
Type of light source:
Lighting technology used: LED Non-directional or
directional:
NDLS
Light source cap-type
(or other electric interface)
SMD
Mains or non-mains: NMLS Connected light
source (CLS):
No
Colour-tuneable light source: No Envelope: -
High luminance light source: No
Anti-glare shield: No Dimmable: No
Product parameters
Parameter Value Parameter Value
General product parameters:
Energy consumption in on-
mode (kWh/1000 h), rounded
up to the nearest integer
16Energy efficiency
class
F
Useful luminous flux (ɸuse),
indicating if it refers to the flux
in a sphere (360º), in a wide
cone (120º) or in a narrow cone
(90º)
1 600 in Wide
cone (120°)
Correlated colour
temperature,
rounded to the
nearest 100 K,
or the range of
correlated colour
temperatures,
rounded to the
nearest 100 K, that
can be set
4 000
On-mode power (Pon),
expressed in W
16,0 Standby power (Psb),
expressed in W
and rounded to the
second decimal
-
Networked standby power (Pnet)
for CLS, expressed in W and
rounded to the second decimal
- Colour rendering
index, rounded to
the nearest integer,
or the range of CRI-
values that can be
set
84
Height 318Outer
dimensions Width 318
Spectral power
distribution in the
See image
in last page
Page 1 / 3

without
separate
control gear,
lighting
control parts
and non-
lighting
control parts,
if any
(millimetre)
Depth 82 range 250 nm to 800
nm, at full-load
Claim of equivalent power(a) - If yes, equivalent
power (W)
-
Chromaticity
coordinates (x and y)
0,383
0,379
Parameters for LED and OLED light sources:
R9 colour rendering index value 17 Survival factor 1,00
the lumen maintenance factor -
(a)'-' : not applicable;
(b)'-' : not applicable;
Page 2 / 3

Not for general waste. Please contact your local authority on how to dispose correctly.
Installation & Maintenance instructions for S16WLED 16W.
Important Information
If you do not feel fully confident when dealing with electrical procedures, seek the advice of a qualified electrician.
This product must be installed in accordance with the current building and IEE wiring regulations.
Switch off the mains before commencing installation. These products are designed for connection to a 240V 50Hz
supply. Any broken or damaged parts should be replaced as soon as possible. We will not accept responsibility for any
claims arising from a poor installation. This product is suitable for outdoor use IP65.
Please note emergency packs/batteries carry a 12 month warranty.
LEDs are an inductive lead and may have higher inrush currents, it may be necessary to update your MCBs to
compensate.
Specification
Power Supply
240V 50Hz
Operating Temperature
0°C - +30°C
IP Rating
IP65
Kelvin
4000K
Lumens
1100lm
CRI
Ra80
Wattage
16W
Life Expectancy
25,000 hrs
Installation:
●Isolate supply voltage before working with electrics.
●Remove trim and diffuser by turning anti-clockwise.
●Loosen but do not remove the three LED gear tray supporting screws, rotate the tray and allow it to hang on the
support strap.
●Pass supply wires through grommet into the base section, taking care to ensure they are not trapped between the
fitting and mounting surface.
●Fix base section to the wall or ceiling. Use adequate fixings with regard to type of surface being fixed to.
FIG 1 - Wiring instructions for non-emergency units.
●Connect incoming neutral cable (blue wire) to the neutral terminal on connector block.
●Connect incoming live cable (brown wire) to the live terminal on the connector block.
●Connect incoming neutral cable (blue wire) to the neutral terminal on connector block.
●Connect incoming live cable (brown wire) to the switch live terminal on the connector block.
●Connect incoming permanent live cable (black wire) to the permanent terminal on the connector block.
●Charge for 24 hours.
●You must complete a FULL discharge and then a further 24 hour recharge prior to testing & full operation.
Microwave Technical Specification
Sensitivity
10% / 50% / 75% / 100%
Hold-time
5s / 90s / 5min / 15min
Daylight sensor
2lux / 10lux / 50lux / disable
Microwave Frequency
5.8 GHz +/- 75 MHz
Detection Range
10m x 6m
Detection angle
30°C ~ 60°C
Working Temperature
-20°C ~ 60°C
Microwave Settings
Neutral - Blue
Earth
Live - Brown
Neutral - Blue
Earth
Live - Brown
Mains Supply Luminaire
FIG 2 – Wiring Instructions for emergency units
Neutral
Earth
Switched Live
Live
Neutral
Earth
Switched Live
Live
Mains Supply Luminaire
318mm
82mm
Installation & Maintenance
S16WLED-WH, S16WCCT-WH, S16W EME CCT,
S16W SEN WH CCT, S16W EM SENS CCT
Unit 7/8 Ashbourne Business Centre, Ballybin Road, Ashbourne, Co. Meath, Ireland, A84 YP58,
Phone: 00353 1 835 7447
Unit 32 Junction One Business Park, Valley Road, Birkenhead, Merseyside, UK, CH41 7ED,
UK Ph: 0330 551 7000
Website: www.sgd.ie
For more information contact:
Detection area, hold time and daylight sensor can be set by using DIP switches
on the sensor. Note that reducing the detection area will also reduce the sensitivity.
Question
SETTINGS
1, Detection area
I: up to 100%
II: up to 75%
III: up to 50%
IV: up to 25%
V: up to 10%
2, Hold time
Refers to the time period the lamp remains at
100% illumination after no motion is detected.
I: 5s
II: 30s
III: 90s
IV: 3min
V: 20min
VI:30min
3,Daylight sensor
The sensor can be set to only allow the lamp to
illuminate below a defined ambient brightness
threshold. The settings are as follows:
I: 2lux, darkness operation only
II: 10lux, darkness operation only
III:25lux, twilight operation
IV:50lux, twilight operation
V:Disable
*When set to Disable, the daylight sensor will switch on the lamp when motion
is detected regardless of ambient light levels.
The load will
not illuminate
Incorrect daylight
sensor setting selected.
Load has failed.
Power is switched off. Switch on.
Adjust setting.
Replace load.
Continuous movement in the
detection area.
The lamp (containing sensor) is
installed in an area too close to
reflective surfaces, i.e. metal,
glass or concrete walls.
Check detection area setting.
1, Make sure installation area
suitable with at least 30cm space
between lamp and surrounding
reflective surfaces.
2, Reduce sensitivity (detection area).
The load is
permanently
illuminated.
The load will
not illuminate
despite
movement.
Speed of moving object is not in
the range of 0.5-3m/s or the
detection radius is too small.
Check detection area setting.
Cause Remedy
FAQ
ON O N O N
ON O N
ON O N
ON
ON
Ⅰ
Ⅱ
Ⅲ
Ⅳ
Ⅴ
1 2 3
100%
75%
50%
25%
10%
ON O N O N
ON O N
ON O N
ON
ON O N
ON
Ⅰ
Ⅱ
Ⅲ
Ⅳ
Ⅴ
4 5 6
Ⅳ
5s
30s
90s
3min
20min
30min
ON ON ON
ON O N
ON
ON
ON
Ⅰ
Ⅱ
7 8 9
Disable
50lux
10lux
2lux
25lux
Ⅲ
Ⅳ
Ⅴ
Not for general waste. Please contact your local authority on how to dispose correctly.
Installation & Maintenance instructions for S16WLED 16W.
Important Information
If you do not feel fully confident when dealing with electrical procedures, seek the advice of a qualified electrician.
This product must be installed in accordance with the current building and IEE wiring regulations.
Switch off the mains before commencing installation. These products are designed for connection to a 240V 50Hz
supply. Any broken or damaged parts should be replaced as soon as possible. We will not accept responsibility for any
claims arising from a poor installation. This product is suitable for outdoor use IP65.
Please note emergency packs/batteries carry a 12 month warranty.
LEDs are an inductive lead and may have higher inrush currents, it may be necessary to update your MCBs to
compensate.
Specification
Power Supply
240V 50Hz
Operating Temperature
0°C - +30°C
IP Rating
IP65
Kelvin
4000K
Lumens
1100lm
CRI
Ra80
Wattage
16W
Life Expectancy
25,000 hrs
Installation:
●Isolate supply voltage before working with electrics.
●Remove trim and diffuser by turning anti-clockwise.
●Loosen but do not remove the three LED gear tray supporting screws, rotate the tray and allow it to hang on the
support strap.
●Pass supply wires through grommet into the base section, taking care to ensure they are not trapped between the
fitting and mounting surface.
●Fix base section to the wall or ceiling. Use adequate fixings with regard to type of surface being fixed to.
FIG 1 - Wiring instructions for non-emergency units.
●Connect incoming neutral cable (blue wire) to the neutral terminal on connector block.
●Connect incoming live cable (brown wire) to the live terminal on the connector block.
●Connect incoming neutral cable (blue wire) to the neutral terminal on connector block.
●Connect incoming live cable (brown wire) to the switch live terminal on the connector block.
●Connect incoming permanent live cable (black wire) to the permanent terminal on the connector block.
●Charge for 24 hours.
●You must complete a FULL discharge and then a further 24 hour recharge prior to testing & full operation.
Microwave Technical Specification
Sensitivity
10% / 50% / 75% / 100%
Hold-time
5s / 90s / 5min / 15min
Daylight sensor
2lux / 10lux / 50lux / disable
Microwave Frequency
5.8 GHz +/- 75 MHz
Detection Range
10m x 6m
Detection angle
30°C ~ 60°C
Working Temperature
-20°C ~ 60°C
Microwave Settings
Neutral - Blue
Earth
Live - Brown
Neutral - Blue
Earth
Live - Brown
Mains Supply Luminaire
FIG 2 – Wiring Instructions for emergency units
Neutral
Earth
Switched Live
Live
Neutral
Earth
Switched Live
Live
Mains Supply Luminaire
318mm
82mm
Specication CCT Version
Power Supply 240V 50Hz
Operating Temp 0°C-+30°C
IP Rating IP65
Colour Temp 3000k, 4000k, 6000k
Multi Wattage 9w, 12w, 16w
Lumens 954lm, 1236lm, 1600lm
CRI Ra80
Life Time 50000H
Specication Standard Version
Power Supply 240V 50Hz
Operating Temp 0°C-+30°C
IP Rating IP65
Colour Temp 4000k
Multi Wattage 9w, 12w, 16w
Lumens 954lm, 1236lm, 1600lm
CRI Ra80
Life Time 50000H
Product end of life instruction.
This Lighting product is in the scope of EU 2019/2020 directive on Waste Electrical and Electronic Equipment (WEEE). This
product must be disposed according to the legislation. This document is intended for use by end of life recyclers or treatment
facilities. It provides the basic information to assure an appropriate end of life treatment for the components and materials of
the product. Please follow pictured diagram on the back of this manual showing how to dismantle the product into different
components which should be disposed correctly. These components would consist of plastic, metal and electronic materials.
It is the responsibility of the end user to dispose of this product correctly. www.weeeireland.ie or contact your local council for
further information.
Disassembly Diagram
ErP
COMPLIANT
IP65
COMPLIANT
Quality
Assurance
years
1.
2. 3.
4. 5.

MICROWAVE MOTION SENSOR FEATURES
Automatic switching based on motion and light level.
Zero-crossing point operation helps protect the sensor against in-rush current.
Super Compact size makes it suitable to x within most luminaires.
4-pole press-in terminal (L, N, N, L’), easy assembly.
Detection area, time delay and daylight threshold can be precisely set via DIP switch.
Wide detection area, range up to 12m in diameter.
SPECIFICATIONS
GENERAL GUIDELINES FOR INSTALLATION
1. The sensor should be installed by a qualied electrician. And ensure that the electricity supply is switched off before
installing or servicing the product.
2. The sensor should not be modied in any way. Any modications made for this product will immediately invalidate any
warranties issued.
3. The company does not accept responsibility for any consequences resulting from unauthorized modication of the
product.
4. The sensor should be connected to a stable power supply of 220-240Vac 50Hz/60Hz.
5. Microwaves cannot pass through metal or brick walls if thicker than 20cm. They will pass through thinner walls but there
will be some attenuation.
6. Installation inside a glass or plastic housing will result in a reduction of detection sensitivity.
7. Expect a reduction of approximately 20% for every 3mm of thickness.
INSTALLATION AND WIRING
The sensor has a 4 position terminal block as pic 1. L(Phase),
N(Neutral), L’(Switched Phase / Control)
The sensor is designed for installation at 3-12m in height.
WIRING SCHEME
FOR ON/OFF FUNCTION: Connect to normal control gears
(normal LED drivers or ballasts), the wiring as per pic 2.
Pic 1 Pic 2
DETECTION PATTERN
Detection area, hold time and daylight sensor can be set by using DIP switches
on the sensor. Note that reducing the detection area will also reduce the sensitivity.
Question
SETTINGS
1, Detection area
I: up to 100%
II: up to 75%
III: up to 50%
IV: up to 25%
V: up to 10%
2, Hold time
Refers to the time period the lamp remains at
100% illumination after no motion is detected.
I: 5s
II: 30s
III: 90s
IV: 3min
V: 20min
VI:30min
3,Daylight sensor
The sensor can be set to only allow the lamp to
illuminate below a defined ambient brightness
threshold. The settings are as follows:
I: 2lux, darkness operation only
II: 10lux, darkness operation only
III:25lux, twilight operation
IV:50lux, twilight operation
V:Disable
*When set to Disable, the daylight sensor will switch on the lamp when motion
is detected regardless of ambient light levels.
The load will
not illuminate
Incorrect daylight
sensor setting selected.
Load has failed.
Power is switched off. Switch on.
Adjust setting.
Replace load.
Continuous movement in the
detection area.
The lamp (containing sensor) is
installed in an area too close to
reflective surfaces, i.e. metal,
glass or concrete walls.
Check detection area setting.
1, Make sure installation area
suitable with at least 30cm space
between lamp and surrounding
reflective surfaces.
2, Reduce sensitivity (detection area).
The load is
permanently
illuminated.
The load will
not illuminate
despite
movement.
Speed of moving object is not in
the range of 0.5-3m/s or the
detection radius is too small.
Check detection area setting.
Cause Remedy
FAQ
ON O N O N
ON O N
ON O N
ON
ON
Ⅰ
Ⅱ
Ⅲ
Ⅳ
Ⅴ
1 2 3
100%
75%
50%
25%
10%
ON O N O N
ON O N
ON O N
ON
ON O N
ON
Ⅰ
Ⅱ
Ⅲ
Ⅳ
Ⅴ
4 5 6
Ⅳ
5s
30s
90s
3min
20min
30min
ON O N O N
ON O N
ON
ON
ON
Ⅰ
Ⅱ
7 8 9
Disable
50lux
10lux
2lux
25lux
Ⅲ
Ⅳ
Ⅴ

Spectrum Test Report
Date
Sam. Status
Instrument
Sample
Sample No.
Manufacturer
: S16WLED-WH
: 10
: SGD LIMITED
Test Condition
Temprature : 25.3Deg RH
WL Range : 350nm-1000nm IP
TTest Mode : Fast Test
Sensitivity
: 2021-12-30 14:41:00
:
: HAAS-2000
: 65.0%
: 52192 (80%)
: 479 ms
: High
Spectrum
1.0 = 2.958e+001mW/nm
350 513 675 838 1000
Wavelength(nm)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
Spectrum SDCM:0.9
0.362 0.367 0.372 0.377 0.382 0.387 0.392 0.397
0.363
0.371
0.38
0.388
0.397
ANSI/4100K, x= 0.382 y=0.380
Colorimetric Parameters
Chromaticity Coordinate: x = 0.3825 y = 0.3787 / u' = 0.2257 v' = 0.5027 (duv=3.01e-04)
CCT= 3959K Prcp WL: Ld=579.1nm Purity=28.4%
Peak WL: Lp=451nm FWHM: =19.6nm Ratio:R=18.7% G=78.0% B=3.3%
Render Index: Ra = 84.1
R1 =83 R2 =89 R3 =93 R4 =84 R5 =83 R6 =85 R7 =88
R8 =68 R9 =17 R10=73 R11=84 R12=60 R13=85 R14=96 R15=78
Photometric & Radiometric Parameters
Flux = 1445.0 lm Eff. : 102.39 lm/W Fe = 4.4230 W
Electrical parameters
V = 230.2 V I = 0.1190 A P = 14.11 W PF = 0.5153 F=49.99 Hz

Declaration Number
Declaration Number
Declaration Number
034-S16W EM SENS CCT
034-S16 EME CCT
034-S16W SEN WH CCT
034-S16WCCT -WH
034-S16WLED-WH
This declaration of conformity is issued under the sole responsibility of the manufacturer.
Model Number:
Codes
Codes
S16W EM SENS CCT
S16 EME CCT
S16W SEN WH CCT
S16WCCT -WH
S16WLED-WH
The product/model of the declaration described above is in conformity with the relevant
Community harmonisation legislation.
Low Voltage Directive (2014/35/EU)
EMC (2014/30/EU)
The product/model of the declaration described above is in conformity with the below
listed harmonised standards and technical specifications listed below:
EN55015:2013, EN61000-3-2:2014, EN61000-3-3:2013, EN61547:2009, EN60598-1:2015,
EN60598-2-1:1989, EN61347-1:2015, EN61347-2-13:2014, EN62471:2008,
EN62031:2008+A1:2013+A2:2015, EN62493:2015
Signed 12/10/2022
This manual suits for next models
4
Table of contents
Popular Security Sensor manuals by other brands

Olimpia electronics
Olimpia electronics BSR-6160 quick start guide

La Crosse Technology
La Crosse Technology Alerts Mobile TX70U-IT manual

Guardian
Guardian EyeSafe G1200 Installation, operation and maintenance

Petzl
Petzl AVAO BOD TECHNICAL NOTICE

Brandson Equipment
Brandson Equipment 304973 user manual

Kidde
Kidde 60WLDR-W-CA user guide

Connected Inventions
Connected Inventions Detectify R3.2 user manual

LG
LG 14HK701G-W.AUB owner's manual

ST Quadrat
ST Quadrat LUX-top GBD-RR 465 installation instructions

Datasensing
Datasensing TLU Series instruction manual

Technogym
Technogym 0WR00914AA quick reference

Wenglor
Wenglor SG4-I operating instructions