1 General Information
1.1 Passive infrared long range detector «Foton-16» (hereinafter, the
Detector) is designed for detecting intrusion into a protected space
and generating an alarm message.
1.2 Ambient class: Boreal climate.
1.3 The Detector is designed to operate continuously around the
clock.
1.4 The Detector does not produce any interferences to other
detectors of the same or other type and designation, as well as to any
domestic radio equipment.
2 Features
- Active infrared channel with antimasking function.
- Possibility of saving of the Detection channel masking parameters
into nonvolatile memory.
- Two-color LED indication with a possibility of it’s disabling.
- Self-testing mode.
- Immunity to insect’s intrusion to the pyrodetector.
- Swivel bracket (supplied) providing ease of the Detector installation
and detection zone repositioning.
3 Specifications
Parameter Value
Detection range, maximum 20 m
Maximum antimasking detection range, not less than 0.1 m
Power supply 9 …15 V DC
Consumption current, not more than 35 mA
Alarm message duration, not less than 4 sec
Operation temperature minus 30 ... +55 °С
Relative humidity under +25 °С without moisture
condensation, up to 98 %
IP rating IP41
Dimensions, maximum 126 х 70 х 55 mm
Mass, maximum 150 g
Average service life, not less than 8 years
Detection zone pattern is shown in Figure 1.
Figure 3 – Terminals for hookup wire connection
Connection of the Detector to the control panel (CP) should be
fulfilled in accordance with CH Installation Guide.
7 The Detector Adjustment
The Detector adjustment should be realized by changing position
of «1», «2», «3», «4» and «5»DIP-switches, located at the top of
PCB. DIP-switch «1» changes sensitivity value, «5» – manages
anti-masking channel operation tactics, «2», «3», «4» supervise only
the LED indication modes.
a) Detector base
b) Swivel Bracket
6
3
5
1
23
4
78910 11
12
Figure 1 – Detection Zone Pattern
4 Scope of delivery
Name QNT
Passive infrared long range detector «Foton-16A»
Swivel bracket
Screw 3-3х30.016
Passive infrared long range detector «Foton-16A».
Installation Guide
1 pc.
1 pc.
2 pcs.
1 copy
5 Installing the Detector
Recommended mounting height of the Detector is 2.3 m above the
floor. The shape of the Detector base allows to mount the Detector
on the wall, as well as in the corner of the room. In case of the swivel
bracket usage (supplied), the Detector can be installed on the wall or
ceiling at a hight 2.3 ... 3 m above the floor. Swivel bracket construction
provides detection zone repositioning.
When choosing the Detector installation place, take note of the fact
that the detection zone may be limited by non-transparent objects
(curtains, houseplants, cabinets, bookcases, etc.), as well as glass and
mesh partitions. There must be no windows, air conditioners, space
heaters or heating radiators in the Detector visibility range.
The Detector installation:
5.1 Unfasten the latch through the opening (5), which is situated
downside the detector case by means of screwdriver and put off the
detector cover.
5.2 Put off the PCB by means of pushing up it’s fixing arm (4) on
the base.
5.3 Drill the holes (1) for wiring and fastening the Detector:
- for wall mounting – holes (6);
- for corner mounting – holes (3).
5.4 Pass the wire through the mounting holes (1) and fasten the
base on the wall (corner) by screws.
5.5 If swivel braket is used for installation:
- open hole (2);
- insert a nut (8) to the sphere bulge (9);
- insert a sphere (9) and then a bush (7) to the base of the swivel
bracket (11).
Fasten an assembled swivel bracket on the wall (ceiling) by screws.
Pass the wires and tighten the base on the swivel bracket by the screw
(12). Fix position of the sphere when tightening the screw (12).
5.6 Put PCB on it’s place.
Figure 2 – Detectoir Base and Swivel Bracket
Note – Places for mounting holes on the installation surface can
be marked using a detector base with opened holes as a pattern.
6 The Detector Hooking up
Marked terminals for the Detector hooking up are located at the top
of the PCB (See Figure 3).
DIP-switch Position
ON OFF
«1» Sensitivity Norm High
«2» TEST Alarm LED
Indication
Indication of
detection
«3» LED indication ON OFF
«4» Alarm memory ON OFF
«5» MASK See Cl. 8.7
MASK
MEM
IND
TEST
SENS
+12V-
ALFAILURE TAMPER
Table 2
b) Top
View
a) Side
View
20 m
20 m
1 m 2.3 m
PASSIVE INFRARED LONG
RANGE DETECTOR
«FOTON-16A»
WITH ANTIMASKING
FUNCTION
Installation Guide
8.7 Masking Detection
The Detector provides anti-masking function. «Masking» message is
displayed by the LED indicator intermittent blinking green. If masking
attributes remain constant, «Masking» message is generated by «AL»
and «FAILURE» contacts opening. Masking message is generated
not earlier than after three minutes upon the expiry of warmup time.
Depending on switch «5» position, anti-masking function is realised
by two modes:
a) upon setting DIP-switch «5» to «OFF» position after every switching
on the Detector stores current circumstances as an basic reference
standard;
b) upon setting DIP-switch «5» to «ON» position the Detector refers
to once-stored current circumstances as an basic reference standard.
Reference environment storage is fulfilled immediately after setting
switch «5» to ON position. If the switch «5» is set to ON position while
the Detector is in »Warm-up time» state with power off, then storage of
reference environment is executed upon the expiry of »warm-up time».
8.8 Detection of repositioning
The Detector controls changing of its tilt relatively to initial position
for more than (5.5 ± 0.5)°. Storage of initial position is executed upon
the expiry of «warm-up time».
9 Storage and Transportation
9.1 The Detector in original package without power supply batteries
is resistant to:
а) transport jolting with the acceleration of 30 m/sec2with impact
frequency rate from 10 to 120 impacts/sec or 15000 impacts with the
same acceleration;
b) the ambient temperature from minus 50 … +50 °С;
c) relative air humidity (95 ± 3) % at the ambient temperature +35 °С.
9.2 The Detectors in original package may be transported by any
transport facility in closed vehicles over any distances in compliance with
the existing shipping rules concerning the respective means of transport.
9.3 After transportation under the conditions different to exploitation
conditions, the Detector shall be ready to operate after a maximum of
six hours.
10 Manufacturer’s Guarantees
The Manufacturer guarantees conformity of the Detector to it’s
Technical Specifications if conditions of transportation, storage,
assembling and operation are observed. The guaranteed storage
period is 63 months since the date of manufacturing the Detector.
The guaranteed period of operation is 60 months since the date of
commissioning within the storage period guaranteed.
The Detectors that are found to non-conforming to it’s Technical
Requirements shall be repaired by the Manufacturer, provided the
installation and operation rules have been complied with.
11 Packing Certificate
Passive infrared long range detector «Foton-16A» has been
manufactured in compliance with the active technical documentation
and classified as fit for operation and packed by «RIELTA» JSC.
Packing date _______________________________
month, year
The Detector generates the following messages:
Table 3
Message Contacts state LED
Indication
Indication
Duration
AL TAMPER FAILURE
«Warm-Up
Time» Opened Opened Opened Red 1 Hz Up to 60
sec
«Norm» Closed Closed Closed OFF
«Alarm» Opened Closed Closed Red
Not less
than 2s
«Case
tampering» Closed Opened Closed
OFF
Up to cause
removal
«Masking» Closed Opened Closed Blinking
green
Up to cause
removal
«Repositioning
or wall
tampering»
Closed Opened Closed
Blinking
green
Up to cause
removal
«Total lack of
power supply» Opened Opened Opened OFF Up to cause
removal
«Voltage drop» Closed Closed Opened Green/
Red
15
minutes1)
«Rise of
ambient
temperature»
Closed Closed Opened Green/
Red
15
minutes1)
«Self-testing
procedure fail» Closed Closed Opened Green/
Red
15
minutes1)
1) «Alarm memory» indication is switched ON with 5 minutes delay and is
lighting during 15 minutes.
8 Switching ON and Testing
8.1 During one minute after energizing the Detector with closed
cover or after closing cover of already energized detector, the Detector
operates in «Warm-up time» mode, after what it changes to standby
mode and is ready to generate «Alarm» message.
8.2 «Alarm» message is generated by opening «AL» contacts for
4 sec after intrusion into detection zone.
8.3 During first seven minutes operation in standby mode the
Detector displays crossing of every sensitivity zone by shot-term blink
(0.25 sec) of red LED indicator. This indication mode allows to check
and adjust detection zone position. If «2» DIP-switch is set to «ON»
position, LED indicator displays an «Alarm» message generation by
lighting red during 4 sec.
8.4 After seven minutes operation in standby mode LED indicator
displays an «Alarm» message generation by lighting red during 4 sec.
To provide masking of the Detector operation, «Alarm» LED indication
can be disabled by setting «3» switch to «OFF» position.
8.5 DIP-switch «1» changes the Detector sensitivity from normal
(«ON» position) to high («OFF» position). Detection range data in
Cl. 3 are reported for the Detector normal sensitivity state.
8.6 Self-Testing
During process of its operation the Detector is monitoring power
supply and ambient temperature values. Also it performs periodical
procedure of detection channel self-testing. In case when ambient
temperature reaches the value close to 36 °С, the Detector sensitivity
level increases automatically.
If power supply reaches the value (62.5 ± 2.5) °С or if self-testing
procedure fails, the Detector generates relevant message by opening
FAILURE contacts. This message is in progress during 15 minutes
after removal of its cause, it is followed by LED indicator alternate
lighting green and red.
«RIELTA» JSC, www.rielta.com,
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],
Tel./fax. +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected].
Rev. 3 оf 03.09.19
v.6.1

Other Rielta Security Sensor manuals

Rielta ORLAN-2 User manual

Rielta

Rielta ORLAN-2 User manual

Rielta STEKLO-3RK User manual

Rielta

Rielta STEKLO-3RK User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta STZ-RK User manual

Rielta

Rielta STZ-RK User manual

Rielta Pyrone-4RK User manual

Rielta

Rielta Pyrone-4RK User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta FOTON-12-RK User manual

Rielta

Rielta FOTON-12-RK User manual

Rielta SH-V-10 User manual

Rielta

Rielta SH-V-10 User manual

Rielta ZVON-1 User manual

Rielta

Rielta ZVON-1 User manual

Rielta Ochrana ORLAN-D User manual

Rielta

Rielta Ochrana ORLAN-D User manual

Rielta STEKLO-3M User manual

Rielta

Rielta STEKLO-3M User manual

Rielta STZ-RK User manual

Rielta

Rielta STZ-RK User manual

Rielta Ladoga MK-RK version 2 User manual

Rielta

Rielta Ladoga MK-RK version 2 User manual

Rielta STZ-RK User manual

Rielta

Rielta STZ-RK User manual

Rielta Ladoga IPR-RK User manual

Rielta

Rielta Ladoga IPR-RK User manual

Rielta PYRONE-8B-RK User manual

Rielta

Rielta PYRONE-8B-RK User manual

Rielta chrana ORLAN-SH User manual

Rielta

Rielta chrana ORLAN-SH User manual

Rielta FOTON-SH2 User manual

Rielta

Rielta FOTON-SH2 User manual

Rielta C.Nord CN-Glass User manual

Rielta

Rielta C.Nord CN-Glass User manual

Rielta Ladoga MK-RK User manual

Rielta

Rielta Ladoga MK-RK User manual

Rielta ZVON-1 User manual

Rielta

Rielta ZVON-1 User manual

Rielta PYRONE-8-RK User manual

Rielta

Rielta PYRONE-8-RK User manual

Rielta FOTON-21 User manual

Rielta

Rielta FOTON-21 User manual

Rielta PYRONE-SH User manual

Rielta

Rielta PYRONE-SH User manual

Popular Security Sensor manuals by other brands

Ecolink PIR-ZWAVE2 installation instructions

Ecolink

Ecolink PIR-ZWAVE2 installation instructions

Alarmtech GD 370 Installer manual

Alarmtech

Alarmtech GD 370 Installer manual

Nice LP21 User, installation and safety instructions

Nice

Nice LP21 User, installation and safety instructions

Elkay Ceilingmountpir Fitting and operating instructions

Elkay

Elkay Ceilingmountpir Fitting and operating instructions

Honeywell SPM Flex user manual

Honeywell

Honeywell SPM Flex user manual

LEGRAND Mosaic 0 489 22 manual

LEGRAND

LEGRAND Mosaic 0 489 22 manual

BFT RIP installation manual

BFT

BFT RIP installation manual

MICRO-EPSILON capaNCDT 6228 operating instructions

MICRO-EPSILON

MICRO-EPSILON capaNCDT 6228 operating instructions

Emos G1160 quick start guide

Emos

Emos G1160 quick start guide

IMMOOS SS1 oGB operating instructions

IMMOOS

IMMOOS SS1 oGB operating instructions

Pilz PSEN 2.1p-20 operating manual

Pilz

Pilz PSEN 2.1p-20 operating manual

Satel COBALT quick start guide

Satel

Satel COBALT quick start guide

Radiodetection 1205CXB Operation manual

Radiodetection

Radiodetection 1205CXB Operation manual

Elkron EIR600FC Installation, programming and functions manual

Elkron

Elkron EIR600FC Installation, programming and functions manual

Besantek BST-HVD9 instruction manual

Besantek

Besantek BST-HVD9 instruction manual

LUDLUM 70 System manual

LUDLUM

LUDLUM 70 System manual

Bosean Electronic Technology BH-4S user manual

Bosean Electronic Technology

Bosean Electronic Technology BH-4S user manual

hager TX510 Setup instructions

hager

hager TX510 Setup instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.