EMERGENCY SWITCHES
More information on www.spamel.eu 19-7-2022
Technical data
Rated insulation voltage Ui500 V
Rated continuous current Iu=Ith 10 A
Rated operational current
Iefor AC-15
2.5 A (230 V)
1.6 A (400/500 V)
Rated operational current
Iefor AC-13
4 A (24 V)
1 A (110 V)
0.25 A (220 V)
Degree of protection IP65
Wire gauge 2× 1...2.5 mm² (solid)
2× 0.75...1.5 mm² (stranded)
Parameters of resistors in the set 270 Ohm
2.2 kOhm
3.9 kOhm
15 kOhm
22 kOhm
47 kOhm
Manual emergency pushbutton OA1 with resistor board
Ordering code
OA1- - -Y1\
Hammer
without hammer
-M with hammer
Signalling
without signalling
-24 with signalling LED 24V AC/DC
-230 with signalling LED 230V AC
-P24 with PULSATING LED 24V DC
(pulsating frequency 2 Hz)
Switches
10, 20
01, 02
11
Pushbutton type
Atriggered automatically after breaking the glass
Bafter breaking the glass press the button manually
Version
W01 surface mounting
W02 flush
Code examples
OP1-W01-A-11
on-plaster mounting, 1 NO switch and 1 NC switch. When the glass is broken the pushbutton is
released automatically (type A acc. to PN-EN 54-11)
OP1-W02-B-10-230-M
flush mounting with 1 NO switch. When the glass is broken it is necessary to push the button
(type B acc. to PN-EN 54-11). Signalling LED 230 V AC. With a hammer.
Product description
OA1 with resistor board can be used in systems with Control and Indicating
equipment which enables a selected state (Alarm, Detection or Damage),
depending on the resistance of the detection line. A dropping resistor,
end-of-line resistor or a switch with dry contacts (NO or NC) can be connected
to the board. The assembly with a resistor board can hold up to two switches,
SP22-10 (NO) or SP22-01 (NC), with one of them connected to the board.
Depending on the type, it can switch on or off the dropping resistor. Available
versions with A or B alarm characteristic are identical to standard assembly
OA1. Resetting the alarm is also the same as in the standard version. Owners of
the manual emergency pushbutton OA1 without a resistor board, can order it
separately, using the code PPOŻ-1700/R01.
Components
Boards
Resistor board
Cable for call points
Accessories
Hammer with a holder PPOŻ-1200\P01
Glass PPOŻ-5701\P01
Normally open switch (10) green
Normally closed switch (01) red
Note
When selecting current paths, the selected type (A or B) should be taken into
account
TYP A
NO contacts (10, 20, 30): after breaking the glass or removing the cover, the
contacts open.
NC contacts (01, 02, 03): after breaking the glass or removing the cover, the
contacts close.
Mixed NC/NO contacts (11, 12, 21): after breaking the glass, the NO contacts will
open and the NC contacts will close.
TYP B
NO contacts (10, 20, 30): after breaking the glass or removing the cover, the
button must be pressed manually - the contacts will close.
NC contacts (01, 02, 03): after breaking the glass or removing the cover, the
button must be pressed manually - the contacts will open.
Mixed NC/NO contacts (11, 12, 21): after pressing the button, the NO contacts
will close and the NC contacts will open.
Emergency switches
EMERGENCY SWITCHES
More information on www.spamel.eu 19-7-2022

113
59
35
flush mounting
Dimensions

113
30
52
Spacing of xing holes
68
Space for a gland
surface mounting
Emergency switches

This manual suits for next models

1

Other Spamel Security System manuals

Spamel SZ/1B User manual

Spamel

Spamel SZ/1B User manual

Spamel SG/1Z User manual

Spamel

Spamel SG/1Z User manual

Popular Security System manuals by other brands

hager 53601 quick start guide

hager

hager 53601 quick start guide

Giant Alarm System JJ-MB-02-2 user manual

Giant Alarm System

Giant Alarm System JJ-MB-02-2 user manual

Amico Alarm Valve Combo Unit Installation and maintenance manual

Amico

Amico Alarm Valve Combo Unit Installation and maintenance manual

CHALET E Series Basic operation guide

CHALET

CHALET E Series Basic operation guide

TeleCare24 Fall Alarm Plan user guide

TeleCare24

TeleCare24 Fall Alarm Plan user guide

Bose Sicilia Entero ESC Installation Menu Guide

Bose Sicilia

Bose Sicilia Entero ESC Installation Menu Guide

Sailor H412 User & installation manual

Sailor

Sailor H412 User & installation manual

Venitem VP/EN54-23 Installation and user manual

Venitem

Venitem VP/EN54-23 Installation and user manual

netvox RA03A user manual

netvox

netvox RA03A user manual

SKYTRONIC 351.023 instruction manual

SKYTRONIC

SKYTRONIC 351.023 instruction manual

Plumis Automist Smartscan Hydra Instruction, Installation, Operation and Maintenance Manual

Plumis

Plumis Automist Smartscan Hydra Instruction, Installation, Operation and Maintenance Manual

Satel SP-6500 instruction manual

Satel

Satel SP-6500 instruction manual

Steren CCTV-500 manual

Steren

Steren CCTV-500 manual

iGuard FPS110 Series Operation manual

iGuard

iGuard FPS110 Series Operation manual

Roule RL-R31 user manual

Roule

Roule RL-R31 user manual

LTS LTD9116MKIT user manual

LTS

LTS LTD9116MKIT user manual

Cobra P1703-141 manual

Cobra

Cobra P1703-141 manual

Gorilla 8007 instructions

Gorilla

Gorilla 8007 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.