SpectraPure UltraPrecise ATO User manual

06-19-2018
UltraPrecise Auto Top Off
Liquid Level Controller
(LLC-UPLC-ATO)
INSTALLATION MANUAL

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
2
SpectraPure
®
ALL RETURNS WITHOUT RMA# WILL BE REFUSED. CLAIMS
MUST BE WITHIN 10 DAYS FROM RECEIPT.
COPYRIGHT© 2016 BY SPECTRAPURE INC
ALL RIGHTS RESERVED
No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means, electronic, mechanical, photocopying,
recording or otherwise without the prior written permission of SpectraPure Inc.
PACKING LIST FOR LLC-UPLC-ATO:
IF ANY OF THE ITEMS LISTED BELOW ARE MISSING PLEASE
CONTACT SPECTRAPURE PRIOR TO INSTALLATION.
- Module w/ Sensor Tubes Attached - 12' White Tubing
- Magnetic Sensor Holder Assembly - Blue Warranty Card
- 12v /800mA Power Supply - Operations Manual
- Allen Wrench
TABLE OF CONTENTS
System Features 3
System Specifications 3
Pump Connections and Controls 4
Setup Diagrams 5
Introduction 6
Familiarizing Yourself With The ATO 6-7
Quick Setup 7
Setup
Settings 8
Fill Mode Setup 8
Drain Mode Setup 8-9
Duty Cycle Setup 9
Setting Pump Speed 9
Pump Speed Settings 10
Duty Cycle Settings 11
System Startup 12
Servicing The Pump Module 12-15
Troubleshooting 16
Five-Year Limited Warranty 16
Warranty Support 16

SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
SpectraPure
®
SpectraPure® Inc. assumes no responsibility for water damage due
to leaks or misapplications of our products. It is the user’s responsibility
to determine that the system is leak-free and properly installed.
SYSTEM FEATURES
• Highest Quality and Accuracy -- New and Improved “Gen 6”
LiterMeter3 Pump machined to aerospace tolerances. Antiwear and anti-
friction coated for exceptional pump life.
• Fully automatic operation - May be programmed to fill a vessel or to
drain a sump (Fill Mode/Drain Mode).
• High reliability metal pump housing
• Virtually maintenance free
• No damage to the pump if run dry
• No check valves to clog or seals to leak
• Self-priming and anti-siphoning
• High limit Sensor Tube for fail-safe operation
• High delivery pressure - over 40 psi
• Compact size and cool operation
• Kalkwasser safe
• Quiet operation and low power consumption
• Complete system consumes less than 3 watts when pump is on
• Extended 5-year Warranty
SYSTEM SPECIFICATIONS:
Pump Flow Rate: Adjustable in 10 Steps up to 180 ml./min.
Dimensions: 5.35"L x 2.15"H x 2.2"W (13.6 cm. x 5.5 cm. x 5.6 cm.)
Maximum Daily Total (per Pump): 260 liters (68.5 gals.)
Draw Height: from maximum 25 feet (7.6 meters) below
Delivery Height: to maximum 60 feet (18.3 meters) above
Power Supply: 115VAC /12VDC wall-mounted power supply
(Can be powered by 12VDC battery)

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
4
SpectraPure
®
This system is not waterproof. Saltwater damage is not covered in our
five year warranty. Do not let the Pump Module fall into water!
Always run a new pump dry for 20 minutes before putting it into service.
Be sure to observe the rollers revolving around the rotating motor shaft
through the hole in the end of the pump head. See “Servicing The Pump
Module” on Page 12 if the rollers don’t move.
Power
Connection
Air Line Tubing
to High Limit
Sensor Tube
Air Line Tubing
to Primary
Sensor Tube
PUMP CONNECTIONS AND CONTROLS:
Pump Speed LED Indicator Lights
(also indicate seconds pump
runs when in Duty Cycle mode)
Down /Drain
Pump Head
Inspection Hole
Up /Fill
INPUT
(from reservoir)
OUTPUT
to aquarium
Press fit the end of a
piece of 1/4"
polyethylene tubing
into the rubber inlet
hose at
least 3/4".
This is
connected
to the
supply
reservoir.
This
reservoir
needs to be vented to
prevent collapse.

SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
SpectraPure
®
SETUP DIAGRAMS:
RESERVOIR
DISPLAY TANK
OR SUMP
ATO
MAGNETIC
PROBE
HOLDER
CLEAR AIR
LINE TUBING
(x2)
NORMAL WATER LEVEL
HIGH LIMIT WATER LEVEL
FRONT VIEW OF THE MAGNETIC
PROBE HOLDER
The high limit sensor will shut the
pump off if the water level reaches the
top of the bevel in the tube. Position
the high limit sensor tube so any
abnormal rise in the sump will
deactivate the circuit and kill power
to the ATO control module. See
page 10 for instructions in setting the
high and low water levels.
The Sensor Tube should be
mounted in the display tank
or sump where the water level
changes due to evaporation.
Pump operation is dependent
upon the water level in relation
to the Sensor Tube.

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
6
SpectraPure
®
INTRODUCTION:
The Ultra Precise ATO (Automatic Top Off) unit works as either an ATO (Fill
mode) or as a sump pump (Drain mode). It has an integrated peristaltic
pump that is capable of pumping approximately 180 ml/min when
running at full speed. This may be regulated by changing the pump speed
in 10 steps, from minimum to maximum. You may further alter the rate
of flow by changing the Duty Cycle. The Duty Cycle consists of recurring
20-second cycles. The default setting is for the pump to run for the entire
20-second cycle. The user may change that setting to allow the pump
to run for as few as 2 seconds during each cyle, in even increments (i.e.
2,4,6,8, etc.). This feature can be extremely useful to dial in exact dosages
when using the ATO as a delivery pump for Kalkwasser, etc.
There are many advantages to the integrated perstaltic pump. The liquids
themselves never come in contact with the internal workings of the pump.
This contributes to the extremely long lifespan of the peristaltic pump. Also,
since the pump does not rely on the liquid being pumped for lubrication,
there are no deleterious effects if the pump is run dry. The LLC-UPLC-ATO
is also capable of pumping liquid to a level of 60 feet above the pump
itself or 300 feet horizontally. This is very handy if your sump is located on
a different floor or in a different room than your aquarium or if you can’t
mount the pump in close proximity.
The ATO comes complete with a liquid level Sensor Tube which allows
the user to set the levels of operation for the pump. In “Fill” mode, it turns
on when the lower level is reached and turns off when the upper level is
reached. It also includes a separate high limit Sensor Tube which works as
a safety backup system. This sensor operates off of a separate circuit which
will function even if the main processor and/or the pump switch were to
fail. If the water level ever reaches the high limit sensor, the pump will be
de-energized and will stay off until the water level drops below the low
water level that has been set by the user.
The sensor tubes are held in place by a proprietary rustproof magnetic
probe holder. This has been designed to hold the sensor tubes securely in
place on tank walls up to 3/4" in thickness.
FAMILIARIZING YOURSELF WITH THE ATO:
The ATO comes “out of the box” ready to move water from your storage
reservoir to your display tank. The Pump will be running at full speed (10)
and will be constantly ON.
Before you connect the ATO to its Storage Reservoir and Display Tank,
take a few minutes to familiarize yourself with the operation of the ATO.
It is most convenient to locate the ATO near the Display Tank, within the
reach of the two airline tubes that are part of the Sensor Tube Assembly.
(continued on next page)

SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
SpectraPure
®
You can cut the tubes in two and extend them with 1/4" OD x 1/8" ID vinyl
tubing to an additional distance of fifteen feet.
There are 6 lights, arranged vertically along the left side of the ATO. They
are numbered 0, 2, 4, 6, 8 and 10. They are used in different modes to
display various values and settings.
There are two buttons, UP ( ) and DOWN ( ). They are used to modify
the runtime characteristics of the pump. Repeated presses of the UP button
steps the indicator lights up to light 10. One more press of the UP button
returns to light 0. Likewise, with the light 0 blinking, one press of the
DOWN button will return the display to light 10. This is the most common
way to quickly switch the pump from off to on and back to off.
During normal operation, the lights will indicate the SPEED at which the
pump is running and the state of the pump — on or off. When the light(s)
are solid on, the pump is on, when the light(s) are blinking, the pump is
not running.
When the Primary Sensor Tube senses the water level dropping below
the “lower limit” point, the pump will turn on and stay on until the Primary
Sensor Tube senses the water level rising to the “upper limit” point. At that
time, the pump will turn off and stay off until the level drops below the
“lower limit” point again.
If the water level EVER reaches the high limit sensor tube, the pump will
be stopped and all six lights will blink rapidly in unison until the water level
is lowered.
When power is normally applied, the ATO will quickly go into its main
mode of normal operation. During normal operation, the lights indicate
the SPEED of the Pump in 10 steps, with 10 representing FULL SPEED and
0 representing OFF. Pressing the UP and DOWN buttons step the lights
through the sequence from 0 to 10. There will be some maximum vertical
distance where the pump may stall when it is set to a speed setting of 1.
Increase the SPEED to 2 or even 3 for reliable operation.
During normal operation, the Primary Sensor Tube is positioned in the
receiving vessel so that the expected high and low levels fall within the
length of the Primary Sensor Tube.
FAMILIARIZING YOURSELF WITH THE ATO: (CONT.)
QUICK SETUP
The Quick Setup should be performed with the High Limit Sensor Tube
out of the water and the Primary Sensor Tube inserted into the water as
shown on Page 5.
With the pump off, hold the DOWN arrow button and apply power. After
3 seconds, release the button. All 6 lights will blink three times in unison.
The pump will then start to run in a normal mode with a pump speed of
10 and a duty cycle of 20 seconds. The water level will now be maintained
to within one-tenth of an inch (±0.1") of this point.

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
8
SpectraPure
®
SETTINGS
When the ATO is initially plugged in and powered up, the bottom light
(0) will blink rapidly for three seconds before engaging the pump. At this
time, the pump may be set for FILL or DRAIN mode.
NOTE: Setting the high and low levels may be performed at a table using
a large glass of water. We recommend using a waterproof marker
to indicate your set points on the Primary Sensor Tube. This will
assist you when installing the Sensor Tube Assembly in your SUMP.
FILL MODE SETUP
1. Power up the ATO unit
2. Within 3 seconds, while light 0 is blinking, press the UP button for
two seconds, then release it. The three lower lights (4,2 and 0) will
blink in a downward sequence.
3. Position the Primary Sensor Tube in the water at the point on the
tube where you want to set the “lower limit”. This will be the level
where the pump will turn on. We recommend that you set this so
that it is at least one inch from the open end of the tube.
4. Press the DOWN button to set the lower limit.
5. The three upper lights (6, 8 and 10) will now blink in an upward
sequence.
6. Position the Primary Sensor Tube in the water at the point on the
tube where you want to set the upper limit. This will be the water
level where the pump will turn OFF. We recommend that you set
this between 0.2 to 4 inches above the lower limit point.
7. Press the UP button to set the upper limit.
8. All six lights will turn on briefly to indicate success. These settings
are remembered even after power is removed from the unit.
DRAIN MODE SETUP
1. Power up the ATO unit
2. Within 3 seconds, while light 0 is blinking, press the DOWN button
for two seconds, then release it. The three lower lights (4,2 and 0)
will blink in a downward sequence.
SETUP:
(continued on next page)

SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
SpectraPure
®
SETUP: (continued)
3. Position the Primary Sensor Tube in the water at the point on the
tube where you want to set the “lower limit”. This will be the level
where the pump will turn OFF. We recommend that you set this so
that it is at least one inch from the open end of the tube.
4. Press the DOWN button to set the lower limit.
5. The three upper lights (6, 8 and 10) will now blink in an upward
sequence.
6. Position the Primary Sensor Tube in the water at the point on the
tube where you want to set the upper limit. This will be the water
level where the pump will turn ON. We recommend that you set
this between 0.2 to 4 inches above the lower limit point.
7. Press the UP button to set the upper limit.
8. All six lights will turn on briefly to indicate success. These settings
are remembered even after power is removed from the unit.
DUTY CYCLE SETUP
1. Power down the ATO unit.
2. Press and hold the UP button
3. Power up the ATO unit
4. All six lights will flash twice to indicate that you are in Duty Cycle
Mode, then one or two lights will blink rapidly, indicating the
current setting for Duty Cycle Mode. (See Page 7 for explanation.)
5. Press the UP and DOWN buttons to adjust this setting.
6. To quit this setup mode, simply remove power from the ATO. This
setting will be remembered.
SETTING PUMP SPEED
During normal operation, the lights will indicate the SPEED at which the
pump is operating and the state of the pump — on or off. Solidly lit lights
indicate that the pump is running; blinking lights indicate that the pump is
not running. In both instances, the lights indicate the SPEED setting of the
pump. Whenever the pump is running, you may use the UP and DOWN
buttons to adjust the pump SPEED. (See Page 10 for further details.)

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
10
SpectraPure
®
10
6
4
2
0
10
6
4
2
0
8
8
10
6
4
2
0
8
10
6
4
2
0
8
Pump
O
Pump
On Full
Pump On
Step 5
10
6
4
2
0
8
Pump O
Step 4
LEGEND
Blinking
On
O
PUMP SPEED SETTINGS
The pump has been set at the factory to run at full
speed when you first turn it on. At this setting, it
will pump at the rate of about 180 ml./min. This
may be adjusted in 10 steps. Step “1” is as slow as
the pump can safely run. When set at Step “10”,
the pump is running at full speed. During normal
operation, the lights will indicate the speed of the
pump. You may use the UP and DOWN buttons
to adjust the speed of the pump. When two
adjacent lights are lit, it indicates that the step is
the number between these two. (e.g. If the lights
next to 6 and 4 are both lit, the pump is running
at Step “5”.)
NOTE: The High Limit Sensor Tube acts as a safety
backup. It is on a separate circuit that will
operate even if the main processor and/or the
pump switch were to fail. If the water level
reaches the High Limit Sensor tube, the pump
will stop and all six lights will blink rapidly in
unison until the water level drops back below
the level of the High Limit Sensor tube. If the
processor is disabled, the pump will still turn
off but the lights will not blink.

SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
SpectraPure
®
DUTY CYCLE SETTINGS
Duty Cycle is a function that will limit the time the pump is on in a 20-second
recurring period. This function adds more precision when controlling the
amount of liquid that is being pumped.
e.g. Typically, when the LLC-UPLC-ATO is running at full speed, it is
pumping about 180 ml./min. (2.85 gallons per hour). If the Duty Cycle is
set to “1” (2 seconds), the overall rate will be about 18 ml./min.
LEGEND
Blinking
O
Duty Cycle Duration Times
These values represent the number of seconds the pump
will run during a 20-second duty cycle. The number values
are doubled since this is based on a 20-second duty cycle.
When two adjacent lights are lit it represents the value
between the two numbers.
NOTE: The Duty Cycle will not allow a setting of 0 seconds.
10 1010 1010
6 66 66
4 44 44
2 22 22
0 00 00
8 88 88
20 secs 18 secs 16 secs 14 secs 12 secs
10 1010 1010
6 66 66
4 44 44
2 22 22
0 00 00
8 88 88
10 secs 8 secs 6 secs 4 secs 2 secs

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
12
SpectraPure
®
SYSTEM STARTUP
1. Before installing your ATO, turn the unit on and run it dry for 20
minutes in order to break the pump in.
2. Use 1/4" tubing to connect the Storage Reservoir to the rubber
tube end of the ATO.
NOTE: Be sure the tubing cannot escape from the Storage Reservoir.
3. Push the tubing into the end of the rubber tubing on the pump.
4. Use 1/4" tubing to connect the right angle fitting on the ATO to
the Display Tank. Firmly push the tubing into the quick connect
fitting until it hits the bottom of the fitting.
NOTE: Be sure the tubing cannot escape from the Display Tank.
5. Mount the Sensor Tube Assembly to the side of your Display Tank
or sump. (See diagrams on Page 5.)
SERVICING THE PUMP MODULE:
These instructions apply to ALL SpectraPure Pump Products. It is
recommended that the pump head be inspected and cleaned, or the
tubing replaced per the following procedure. (Refer to images on pages
14-15)
1. If you are just inspecting the pump head, it is not absolutely necessary
to disconnect the two tubings from the head, but it might make this
task easier (Fig. B-1).
2. Use the provided 3/32" Allen Hex Key to remove the three bolts in
the pump head and lift the pump head away from the motor shaft.
(Fig. B-2)
3. Remove the three white rollers from the pump head. (Fig. B-3)
4. If they are dirty, clean the three white rollers, tubing, head and base
plate with a cloth soaked in De-Solv-it®(available in most grocery
stores), acetone, or petroleum spirits. Make sure you remove all
gummy deposits, then rinse parts with water and dry. Next, wipe
the motor shaft clean. Be careful not to spill solvents on the plastic
case or it will damage the finish. Keep cleaning fluids away from the
bearing at the base of the motor shaft.
(continued on next page)

SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
SpectraPure
®
5. If you are replacing the tubing assembly, remove the tubing from
the pump head as shown in Fig. B-4. Replace the tubing assembly
with a new tubing assembly. Reinstall by firmly inserting the tubing
into the outlet port of the pump head as far as possible. (Fig. B-5)
6. Pinch the other end of the tubing and insert it through the slot at
the inlet port of the pump body. Manipulate the tubing so that it
conforms to the inside diameter of the pump body. Be sure that the
tubing is completely pushed down into the output port so the tie-
wrap is within 1/16" of the pump body and the plastic “wear strip”
is positioned to the inside so the rollers will contact the wear strip
evenly. (Fig. B-6)
7. Place two of the three rollers into the pump body, pushing them
against the tubing. (Fig. B-7) Hold them in position with your left
thumb and then push the third roller into place. (Fig. B-8)
8. Carefully line up the locator pin with the slot in the inlet port. (Fig.
B-9)
9. Press the pump head firmly against the pump plate and check for
proper alignment. (Figs. B-10 and B-11) Use the 3/32" Allen Hex Key
to reinstall the three pump head bolts. (Fig. B-12)
10. Replace the union connector on the output port stud. The final
assembly should look like Fig. B-1.
11. Run the pump dry for 20 minutes. Be sure to observe the rollers
revolving around the rotating motor shaft through the hole in the
end
of the pump head.
SERVICING THE PUMP MODULE: (continued)
(continued on next page)

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
14
SpectraPure
®
Fig. B-1 Fig. B-2
Fig. B-3 Fig. B-4
Fig. B-5 Fig. B-6
SERVICING THE PUMP MODULE: (continued)

SpectraPure
®
Inc
. Fax 480.894.6109 Fax us toll-free 1.877.527.7873
SpectraPure
®
Fig. B-7 Fig. B-8
Fig. B-9 Fig. B-10
Fig. B-11 Fig. B-12
SERVICING THE PUMP MODULE: (continued)

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
16
SpectraPure
®
TROUBLESHOOTING:
Excessive Noise
1. Make sure that the Pump Module is not attached to or sitting
atop a box or enclosure that will act as a “speaker” and amplify
the vibration of the pump.
2. Secure the attached tubing so that it does not vibrate against
nearby walls, cabinets, or other objects.
No LEDs are lit
1. Replace power supply
Lights are on but rollers are not turning
1. Look through the observation hole at the end of the pump head
and see if the shaft is turning. If not, call SpectraPure Technical
Support.
2. If the shaft is turning, follow the instructions on pages 12-13 for
servicing the pump head.
Pump is running and rollers are turning but no fluid is being pumped.
1. Check the ends of the tubing for obstructions.
2. Check for a loose connection on the suction side which will
cause the pump to lose its prime.
FIVE-YEAR LIMITED WARRANTY:
SpectraPure, Inc. warrants each new Ultra Precise ATO to the original owner only to be free
of defects in material and workmanship for a period of 5 years from the date of receipt.
SpectraPure’s liability under this warranty shall be limited to repairing or replacing on
SpectraPure’s option, without charge, F.O.B. SpectraPure’s factory. SpectraPure will not be
liable for any cost of removal, installation, transportation, or any other charges which may
arise in connection with a warranty claim.
SpectraPure will not be liable for damage or wear to products caused by abnormal operating
conditions, accident, abuse, misuse, unauthorized alteration or repair, improper installation
and operating conditions, power failures, freezing, flood, fire, or acts of God.
WARRANTY SUPPORT:
As confident as we are in our Pump Technology, we request that you fill out and return the
Warranty Card in order to take full advantage of our FIVE YEAR WARRANTY.
This manual suits for next models
1
Table of contents
Other SpectraPure Controllers manuals
Popular Controllers manuals by other brands

Allen-Bradley
Allen-Bradley PowerFlex 755 IP00 installation instructions

Aaeon
Aaeon AEC-6841 manual

Sunrise System
Sunrise System SRS 100 Guide

Onkyo
Onkyo SC886 - PR Preamplifier / Processor instruction manual

Basler
Basler DGC-2020HD Installation instructions manual

Tyco
Tyco BIFFI EHAS Series Installation Instructions and Maintenance Manual