Speedfit JGTRV User manual

speedfitUFH.co.uk
For model:
JGTRV
Instruction Manual

Contents
JGTRV
2x AA Batteries
Instruction Manual
speedfitUFH.co.uk
For model:
JGTRV
Instruction Manual
Icons used in this manual:
Safety
Important info
Your benefit
Instruction manual:
• Box contents
• Introduction
• Product compliance and
Safety information
• Installation
• User interface
• Status/LED indication
• Installer notes
For latest PDF Instruction Manual
please go to speedfitUFH.co.uk
02
Wireless TRV Instruction Manual
Adapter
Box contents:

Introduction. Thank you for purchasing the Speedfit Aura Wireless
TRV (JGTRV). The JGTRV simply replaces the passive head supplied
with a standard Thermostatic Radiator Valve (TRV). The JGTRV must be
used with a JGSTATW1 or JGSTATW2 Wireless Thermostat and a JGCO
Wireless coordinator (all sold separately). The JGTRV can be used with
the JGBR Wireless Boiler Receiver (configured to RX1) and other Aura
wireless products (see below).
Product Compliance. This product is CE compliant and meets the
following EC Directives:
RoHS2 directive 2011/65/EU, Electro-Magnetic Compatibility
directive 2004/108/EC and Low voltage directive 2006/95/EC.
Safety Information. Use in accordance with the regulations. The
Aura JGTRV is to be used for room control in buildings.
Installation. This accessory must be fitted by a competent
person, and installation must comply with the guidance, standards
and regulations applicable to the location where the product is
installed. Failure to comply with the relevant standards could lead to
prosecution.
JGSTATW1/
JGSTATW2
Thermostat (Required)
Wiring Centre JGWCW
JGBR
(Optional)
JGCO
(Required)
03
speedfitUFH.co.uk
Product Compliance & Safety Information

To provide the best level of system control, we recommend that the
JGTRV is installed with a JGBR Boiler Receiver (configured to RX1).
This enables the Wireless Thermostats in the system to switch the boiler
on/off whilst also opening/closing the radiator valves.
+
Only 3 TRV’s can be paried to a JGSTATW1/JGSTATW2.
The JGTRV is
modulating which
means it can
regulate the flow-
rate through the
valve. A paired
Wireless Thermostat
increases/decreases
the flow-rate
through the valve
based on the
difference between
the set temperature
and the room
temperature.
04
Wireless TRV Instruction Manual
System Overview

Installation - General
Detach top housing
by pressing a flat
screwdriver into the
slot as shown above.
Remove the battery
cap.
Insert the batteries
and replace the
battery cap.
Please note correct
battery orientation.
Gently place the
top housing onto the
bottom housing.
Note correct
orientation.
Optional adapter.Ready to be fitted
to the radiator valve.
Note: The LED will
flash green and then
red before eventually
changing to solid red.
1 2 3
4 5
05
speedfitUFH.co.uk

Place the TRV over
the radiator valve.
Tighten the TRV
(finger tight) to the
radiator valve.
Check that LED is
solid red.
Press any button to
commence adaptive
mode.
Adaptation to the
valve is complete
once all noise and
LED activity has
ceased. If LED
continues to flash
refer to page 11.
The unit is now ready
for pairing to the
Aura thermostat.
It is recommended
that pairing is done on
a room by room basis.
06
Wireless TRV Instruction Manual
Installation - General
6 7 8
9
10 11

1
2
3
System setup checklist
The Wireless Coordinator must be in
Pairing Mode.
Before starting the pairing, make sure
the light is flashing on the Coordinator
by holding the button for 5 seconds.
Please refer to the JGCO Wireless
Coordinator Instruction Manual.
Ensure that the thermostat is powered up and ready for
configuration and pairing.
Please refer to pages 32 and 37 in the Wireless Thermostat
Instruction Manual.
If you are using the optional JGBR Boiler Receiver configured for
remote boiler switching, ensure this has been powered up and
the red flashing LED has gone steady.
Please refer to Boiler Receiver Instruction Manual.
07
speedfitUFH.co.uk
Installation - Pairing

Press and hold the pairing button
for 5 seconds.
Once the red LED starts flashing go
to page 37 in
JGSTATW1/JGSTATW2
Instruction Manual.
When pairing is successful with the JGSTATW1/JGSTATW2
thermostat the LED will go out.
08
Wireless TRV Instruction Manual
1
2
Installation - Pairing

LED Indication
Pairing Button
Manual
open/status
indication
Manual
close/status
indication
09
speedfitUFH.co.uk
User Interface

LED flashes red
twice. The valve is
manually closed.
LED flashes green
twice. The valve is
manually open.
If wireless link is lost error code **-07 will show on the
connected thermostat.
Manual Mode (See page 12)
10
Wireless TRV Instruction Manual
Status Indication
Short press on
either button will
show status.

Low Battery
If the battery low, the red light
will flash three times every ten
seconds. When replacing batteries
follow steps 1 to 9 on page 5 and 6.
Installation Error
If there is an error in the installation
the TRV LED will flash Red / Green
alternately. Please remove the TRV
from the radiator valve and repeat
the installation steps on page 6.
Low battery in the radiator valve will also be shown as
error code **-22 on the connected thermostat.
11
speedfitUFH.co.uk
LED Indication

Long press to
manually open TRV.
LED flashes green once and then goes out.
To check status refer to page 10.
To remove the JGTRV from auto mode, follow steps below.
Long press to
manually close TRV.
LED flashes red once and then goes out.
To check status refer to previous page.
Short press to return to Auto
mode. Red LED will flash
once to confirm that the unit
is in AUTO.
12
Wireless TRV Instruction Manual
Manual Override

Model JGTRV
Type Hydraulic Radiator Valve
DC Motor
M30 x 1.5
Input 3 push buttons.
Auto/Open/Close/Pair
LED Indicator Bi-Colour, Red/Green
Valve Adaptation Automatic
Power Source 2 x AA Batteries
Battery Life 12 Months
Control Method Modulating
Communication Zigbee - 2.4GHz
Operating Temperature 0ºC to 50ºC
Storage Temperature -20ºC to 60ºC
13
speedfitUFH.co.uk
Technical Detail

14
Wireless TRV Instruction Manual
Installer Notes

15
speedfitUFH.co.uk
Installer Notes
Disclaimer
Customers that choose to operate their heating remotely using JG Aura Range
technology via their personal computer, tablet or smart phone device(s) will
be entering into a contract with Salus Controls plc (“Salus”), which is a third
party supplier of the software. John Guest Ltd and afliates within the John
Guest group of companies from time to time (the “John Guest Group”) make
no representations or warranties of any kind about the reliability or suitability of
the software or applications provided by Salus. The John Guest Group disclaims
liability (excluding liability for death and personal injury resulting from negligence)
for any loss or damage caused by the software provided to customers by Salus.
Any agreement entered into with Salus is therefore strictly at your own risk.

John Guest Speedfit Limited
Horton Road, West Drayton, Middlesex UB7 8JL, England.
Tel: 01895 449233
Fax: 01895 420321
speedfitUFH.co.uk
Technical Help Desk: 01895 425333
The above namestyles are all trademarks of John Guest International Limited.
©
John Guest International Limited 2016. All rights reserved.
Z2105/424/1016
,and
Table of contents
Other Speedfit Thermostat manuals