Speedfit JGSTAT2W User manual


02
JGSTAT2 Instruction Manual
Instruction Manual
GSTAT2W
(White)
GSTAT2B
(Black)
Fixing screws
Box contents:
Contents
Icons used in this manual:
Safety
Important info
Your benefit
For latest PDF Instruction Manual please
go to .speedfitUFH.co.uk
Instruction manual:
• Box contents
• Introduction
• Product compliance
• System options overview
• Installation
• Parameter settings
• Error codes
• User guide
• Installers notes

03
www.speedfitUFH.co.uk
Introduction. Thank you for purchasing
one of our Speedfit Aura 230V Thermostat
models. To use all of the Thermostat
features, the optional communications
cables is required.
The unit can be configured to be a
Programmable Room Thermostat (PRT),
Group Control Thermostat, Group
Thermostat or Hot Water Timer.
Communication between neighbouring
GSTAT2 and GSTAT1 Dial Thermostats is
possible via the GWC Wiring Centre
(pictured below) and the optional
communications cables. More information
can be found on pages 9 and 10.
Safety Information. Use in
accordance with the regulations.
The Aura GSTAT2 is to be used
for room control of heating and
hot water systems inside
buildings.
Product Compliance. This
product is CE compliant and
meets the following EC
Directives:
RoHS2 2011/65/EU, Electro-
Magnetic Compatibility directive
2004/108/EC and Low voltage
directive 2006/95/EC.
Speedfit Aura Wiring Centre GWC
We hope you enjoy this product...
Product Compliance & Safety Information

Emergency. Switch off the voltage
to the individual thermostat, wiring
centre or complete system.
Sources of danger. The
thermostat must be disconnected
from mains supply before removing
the cover.
For the installer. Please enter
any parameter changes in the
Installer Notes section (pages 72
- 75).
Installer parameter
settings. The Aura GSTAT2
is equipped with an Installer
Parameter section (see page
40). This must only be entered
by the installer or a competent
person. Changing these
parameters can have a serious
effect on your heating system.
230v AC
Warning. This product must be
fitted by a competent person.
Installation must comply with the
guidance, standards and
regulations applicable to the
location where the product is
installed. Failure to comply with the
requirements of the relevant
guidance, standards and
regulations could lead to injury,
death or prosecution.
These instructions are applicable to the
Speedfit Aura model stated on the front cover
of this Instruction Manual only.
Warning. Always isolate the
AC Mains supply before
installing or working on any
components that require 230v
AC 50Hz supply.
04
JGSTAT2 Instruction Manual
Product Compliance & Safety Information

Programmable Room
Thermostat (PRT) The unit can be
configured to either
one of the following.
UFH Manifold
Wiring Centre
Radiator
Boiler
Hot Water
Group Control
Thermostat
Group
Thermostat
Timer
05
www.speedfitUFH.co.uk
System Overview - Configuration Options
1
2
3
4
SYSTEM OVERVIEW

Programma le Room Thermostat (PRT). When configured for PRT (see page 31) the
Programmable Room Thermostat mainly works by itself and allows the user to have separate
Time and Temperature control of each zone on the wiring centre. Features like Holiday, Party and
Frost mode have to be set on each individual thermostat. The PRT can be configured for global
heat/cool system changeover if your system supports this. This is achieved from a switched input
from the Wiring Centre (see the Wiring Centre Instruction Manual). Communication Connection
(see page 13) is required to use heat/cool changeover function.
Group Control Thermostat. When configured as a Group Control Thermostat (see page 33),
the unit allows central control of up to 7 Group Thermostats (see below). There can be a
maximum of 2 groups per 8 zone wiring centre. Permanent temperature override, Holiday, Party
and Frost modes can be selected centrally from the Group Control Thermostat. Holiday mode
will also be applied to a timer if applicable. Communication connections (see page 13) are
required for grouping the Group Thermostats. Thermostats can be also globally changed from
heating to cooling thermostats if your system supports this by using the switched input
connection on the GWC (see the Wiring Centre Instruction Manual) along with the
Communications connections mentioned above.
Group Thermostat. When configured as a Group Thermostat (see page 36), the unit will follow
the time schedule and override modes of the Group Control Thermostat. The Group Thermostat
can have its own programmed temperatures, Manual Override and also be removed from the
group temporarily or permanently. Communication connections are required (see page 13).
Timer. When configured as a Timer (see pages 32 and 34), the unit will operate without
temperature control. In this configuration, the unit can be used as a Hot Water Timer. The Timer
will also follow a Group Control Thermostat when Holiday mode has been activated (requires
communication connections).
06
JGSTAT2 Instruction Manual
System Overview - Configuration Options

Power and Switching cable – used to
power thermostats and drive output.
Grouping and Communication cable.
Communication cable can be used when units are used as individual PRT's for
heat/cool changeover. Please refer to page 13 and the Wiring Centre
Instruction Manual.
While the units can function as standalone PRTs or
Timers, installing this optional inexpensive
Communication cable allows the units to communicate
with each other. This allows a thermostat to assume
convenient remote control of a group. This brings
central control of features such as Time Control,
Holiday and Party functions as well as Frost Control.
The individual group members can leave or re-enter
group control at the push of a button.
Cable size 1.5mm 3 core for L,N,SL and 0.5mm twin for the communication.
07
www.speedfitUFH.co.uk
System Overview - Ca les
SYSTEM OVERVIEW

Option 1 - age 09. Unit is configured as individual PRT.
Option 2 - age 10. Unit is configured as a Group Control Thermostat used to control
a group(s) of unit(s) configured as Group Thermostats.
Option 3 - age 10. Unit is configured as a Group Control Thermostat used to control a
group(s) of Digital Stat(s) configured as Group Thermostats.
The systems below, although not exhaustive show the main
options. The maximum number of groups per GWC Wiring
Centre is two. The group selection communication cable
must correspond to the group terminals on the GWC Wiring
Centre. Please refer to the GWC Instruction Manual.
All digital variants can be
configured from GSTAT2. Groups
must have a Group Control
Thermostat. 1 or 2 groups can be
used per wiring centre. HW Timer
can be stand alone or part of a
group. If using HW Timer as part
of a group it must be in Group 1.
08
JGSTAT2 Instruction Manual
System Overview - Options
Group 1 Group 2
Group 1 Group 2

FUNCTION RT USING COMMUNICATION
CONNECTION - RT
Individual Room Control 44
Individual Holiday Function 44
Individual Party Function 44
Individual Heating Program 44
Individual Frost Function 44
Group Holiday including HW 66
Group Party 66
Group Heating Program 66
Group Permanent Override 66
Group Temporary Override 66
Heat/Cool changeover 64
Note: The communication connection is only used for heat/cool changeover when
using units configured to PRT’s and using the relevant connection on the GWC
Wiring Centre. Please refer to the Wiring Centre Instruction Manual.
Option 1 - age 31.All thermostats set as PRT.
09
www.speedfitUFH.co.uk
System Overview - Grouping and Communication
SYSTEM OVERVIEW

FUNCTION RT USING COMMUNICATION
CONNECTION - GROU CONTROL
Individual Room Control 44
Individual Holiday Function 44
Individual Party Function 44
Individual Heating Program 44
Individual Frost Function 44
Group Holiday including HW 64
Group Party 64
Group Heating Program 64
Group Permanent Override 64
Group Temporary Override 64
Heat/Cool changeover 64
Note: HW timer will only use HOLIDAY mode when the communication connection
is used. Also the HW Timer must be connected to GROUP 1 communication
terminals on the Wiring Centre. Please see the Wiring Centre Instruction Manual.
Option 2 - age 33 Option 3 - age 35
10
JGSTAT2 Instruction Manual
System Overview - Grouping and Communication

When the unit is configured as a Hot Water Timer (see page 34) there
are two methods of connecting the cylinder thermostat.
Unit configured to
Hot Water Timer.
Cylinder thermostat options:
Connected directly to GWC (default).
Connected directly to GSTAT2.
11
www.speedfitUFH.co.uk
System Overview - Hot Water Option
1
2
SYSTEM OVERVIEW

Connected direct to GWC (default).
SL L N
12
+
SL L N
12
+
SL L N
12
+
SL L N
12
+
For convenience there is a unique built in option allowing the cylinder
thermostat to be connected to either the HW Timer or Wiring Centre.
12
JGSTAT2 Instruction Manual
System Overview - Hot Water Option
1 2
Please refer to the Wiring Centre Instruction Manual and page 18 for more information.
Connected direct to GSTAT2 (requires
additional parameter change see page 40).

1 2 3
Understanding your terminal connections.
Rear of unit
Communication Terms
12v DC. Two wire twisted
pair can be used for
Grouping Functions between
Group Control Thermostat,
Group Thermostat and HW
Timer.
Power Terminals 230v
AC. Used for supplying
power to the unit and
switched output.
Sensor Terminals. Can
be used for external AIR or
Floor sensor when
configured as thermostat.
Can also be used for
cylinder thermostat when
configured for HW.
13
www.speedfitUFH.co.uk
Installation - Terminal Connections
1
3
2
INSTALLATION

Carefully remove the front housing.
60mm
14
JGSTAT2 Instruction Manual
Installation - Thermostat Mounting
12
3

Not to be positioned on an exterior wall.
Not
Do not insta
Only the te
Not
Do not insta
Only the te
Not
Do not insta
Only the te
Not
Do not insta
Only the te
Mounting position and installation. To ensure trouble free operation and efficient
control, the unit is best positioned in a draft free area and at 130cm from the
floor. Do not position the thermostat near any heat source, behind curtains, in
direct sunlight or an area of high humidity.
15
www.speedfitUFH.co.uk
Installation - Thermostat Mounting
130cm
INSTALLATION

SL N L
GROUP 2 GROUP 1
---- ++++
ZONE 1
SL N L SL N L SL N L SL N L SL N L SL N L SL N LSL N L
ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
5 x 20mm
5 x 20mm
While the thermostats can function as PRT or
Timers, installing this optional inexpensive
Communication Cable allows the thermostats to
communicate with each other. This allows the
thermostat to assume convenient remote control
of groups of thermostats bringing central control
of features such as Time Control, Holiday and
Party functions as well as Frost Control. The
individual group members can leave or re-enter
group control at the push of a button.
Optional
communication
connection 12v DC
For more detail refer to the Wiring Centre
Instruction Manual.
16
JGSTAT2 Instruction Manual
Installation - Thermostat Connections

Note: If you are using an External Sensor, the unit has to be
configured for External Air Sensor or Floor Protection Sensor.
Please see Device Parameter Setting on page 40.
Aura External Sensor (sold separately).
17
www.speedfitUFH.co.uk
Installation - Thermostat External Sensor
INSTALLATION

Power Connections 230v AC
If hot water is part
of a group then the
communication
connection must be
connected to group 1.
18
JGSTAT2 Instruction Manual
Installation - Hot Water Timer Wiring
ZONE 1
SL N L SL N L SL N L SL N L SL N L SL N L SL N LSL N L
ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
5 x 20mm
5 x 20mm
SL NL
GROUP 2 GROUP 1
---- ++++
Optional
communication
connection 12v DC

ZONE 1
SL N L SL N L SL N L SL N L SL N L SL N L SL N LSL N L
ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
5 x 20mm
5 x 20mm
ZONE 1
SL N L SL N L SL N L SL N L SL N L SL N L SL N LSL N L
ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
5 x 20mm
5 x 20mm
Note: Optional - The GSTAT2 can be configured for a connection to a cylinder
thermostat. Please see Device Parameters on page 40. For additional wiring
centre information refer to the Wiring Centre Instruction Manual.
IN OUT
HW Timer connected
to cylinder thermostat.
Link must
be fitted
IN OUT
WC connected cylinder
to thermostat (Default).
Cylinder thermostat
19
www.speedfitUFH.co.uk
Installation - Hot Water Timer Cylinder Thermostat
INSTALLATION

Check that the wiring is completed for:
Please use the screws provided.
Ensure the orientation arrow is
pointing upwards.
You are ready to secure the rear housing to the wall box.
Power terminals.
Sensor terminals (if applicable).
Communication connections (optional but recommended).
20
JGSTAT2 Instruction Manual
Installation - Thermostat Mounting
1
2
3
This manual suits for next models
1
Table of contents
Other Speedfit Thermostat manuals