Sper scientific 800018 User manual

Bluetooth® Datalogging
RH / Temperature /
Barometer
800018
Instruction Manual

2
TABLE OF CONTENTS
1. INTRODUCTION . . . . . . . . . . . 3
2. FEATURES . . . . . . . . . . . . . . . 4
3. MATERIALS SUPPLIED . . . . . . . 4
4. MONITOR DESCRIPTION . . . . . . . 5
5. SETUP . . . . . . . . . . . . . . . . . 6
6. PROGRAMMING THE DEVICE . . . . 7
7. DOWNLOADING THE DATA . . . . . 11
8. ADDITIONAL FEATURES . . . . . . 12
9. CARE AND MAINTENANCE . . . . . 13
10. SPECIFICATIONS . . . . . . . . . . 14
11. WARRANTY . . . . . . . . . . . . . 15

3
INTRODUCTION
This Sper Scientic humidity, temperature,
barometer, datalogger (model 800018) oers
a compact design and the convenience of
Bluetooth® streaming to a smartphone App
for data storage and sharing. Humidity,
temperature, and barometric pressure cycle
automatically on the large LCD screen
while Hi/Low alarms are clearly indicated at
a distance by the color-coded bright LED
light on the housing. An optional audible
alarm matches this warning from the phone.
Measurement intervals can be set up to 12
times per day with 16000 datapoints available
per parameter. Once the dataset is complete,
there is no need to attach the device to a
computer to retrieve comprehensive reports.
Simply download a full color graphical report
and e-mail it directly from the phone to any
computer for printing or further analysis in
Excel. Quickly view Min/Max at any time by
pushing a button on the device without
interfering with the datalogging. The App
can simultaneously communicate with up to
3 loggers allowing the user to have multiple
units in dierent areas of any business.

4
FEATURES
• Min/Max for each function.
• Attached ip-out tag for wall mounting.
• Magnetic backing
• Long life Lithium Battery
MATERIALS SUPPLIED
• Temperature
• CR2 Lithium ion battery
• Instruction manual

5
MONITOR DESCRIPTION
1. LCD Display
2. Color-coded LED light
3. Power/Start/Stop
4. Min/Max
5. Magnets for mounting
6. Flip out wall mount
7. Battery Door

6
SET UP
Battery Installation
1. Using a coin or slotted screwdriver, turn
the battery door counter-clockwise to open
the housing.
2. Carefully install the CR2 Lithium ion bat-
tery, ensuring correct polarity.
3. Replace the battery door and turn clock-
wise using gentle inward pressure.
Download the App
You will need to download the free App from
iOS or Android before using this device.
1. Search Nice Logger in the App store and
look for this icon
2. Download the App and open it on your
smartphone.
3. Connect the phone to the logger by select-
ing the serial number on the screen that
matches the logger.

7
Changing the Unit of Measure, naming the
device, or setting a password.
1. On the main screen of the app
(operation screen), select the Logger ID icon.
2. Using the toggle keys, select the desired
Fahrenheit or Celsius temperature unit and
hPa or inHg scale for barometric pressure.
3. Click in the gray ID box to name the device.
Naming the Device can provide a description
for all reports such as “warehouse temperature”
or “My datalogger.”
PROGRAMMING THE DEVICE
Once the device starts logging, you will not
be able to change the settings. Make sure
all parameters are set properly before
starting the device.
1. Press POWER to turn the device on.
2. Open the app on your smart phone and
connect to the device by pressing the serial
number in the upper left corner.
3. The operations screen should display on
the main screen. If it does not, press the
serial number again.

8
4. Press the congure icon to open the inter-
active settings display.
5. For each parameter, select the gray box for
data entry.
6. Set the sampling rate. The sampling rate
is equal to how often the logger takes a
reading. You can set it to once every ten
seconds all the way up to once every 2
hours. Once your desired selection has
been made click done.
7. Select the starting mode as key or on time.
All methods require you to push the start
button on the App before the logging will
commence. If the logging is for a future
date, you will still need to press start, but the
logging won’t begin until the date and time
you set.
8. Set the stop time. There are four options for
this, which are described below:
Memory Full or Key stop: The logger will
continue taking readings until the memory is
full. Once the memory is full, it will not take
any more readings. You can override this by
manually stopping the logger at any time.

9
Memory Loop till key stop: The logger will
continue taking readings until the memory is
full. Once the memory is full, it will continue
taking readings, replacing the earliest data with
new readings. You can override this by manu-
ally stopping the logger at any time.
Memory Full or on Date/Time: The logger
will continue taking readings until the Date and
Time you program it to stop. It will stop reading
if the memory is full before the date/time you
set. You can override this by manually stopping
the logger at any time.
Memory Loop till Date/Time: The logger will
continue taking readings until the date and
time you set. If the memory is full before the
preset date and time, it will continue taking
readings and replace the earliest data with new
readings. You can override this by manually
stopping the logger at any time.
9. Set the alarm to sound by either a single
event or for the entire time the logger is
active (cumulative)
10. Choose which parameters to alarm.
Individual alarms can sound and show a
visible warning light for each parameter.
Click done after your alarms are set.

10
11. Click Save in the upper corner of the
screen. This step is important. The
logger will not function if the settings
are not saved.
12. Make sure you have the desired units of
measure selected from the Logger ID sec-
tion on the main screen (standard or metric)
and press done.
13. Press the Start Logging button on the main
screen of the phone to begin. The meter
itself will display REC to conrm that the
datalogging is underway.
IMPORTANT: DO NOT PRESS START/
STOP ON THE DEVICE. IT WILL SHUT
THE MONITOR OFF. IF YOU SHUT THE
MONITOR OFF, YOU WILL NEED TO
RESAVE THE SETTINGS BEFORE
INITIATING THE DATALOGGING.

11
DOWNLOADING THE DATA
1. Stop the datalogging by pressing the
stop logging icon in the App or turning
the monitor o with the START/STOP
button.
2. Turn the monitor back on if necessary to
connect to the App.
3. Select Readout from the main screen of
the App.
4. The App will ask for the serial number.
Enter the number of the device in the
gray box and click Done.
5. The App will download the data from the
device, as indicated by the progress bar.
6. After the le has downloaded, return to
the main operation screen and click les
at the bottom of the logger screen. All
downloaded les will appear.
7. Select the le in question and choose
CSV (Excel) or PDF format from the
icons at the top of the screen.
8. Your le can now be sent via text,
e-mail, le sharing, or any other data
sharing application available on your
phone.

12
ADDITIONAL FEATURES
Password Protection: The device can be
protected from unauthorized use by applying
a password. To do this, enter the Logger ID
screen and toggle the password option on.
Manual Min/Max: You can view the
minimum and maximums for each parameter
at any time directly on the device without
having to look at the phone app. Simply
press the min/max button to toggle through
the minimum and maximum values. Once
they have been viewed, toggle to the main
screen by pressing min/max again.

13
CARE AND MAINTENANCE
• Do not use abrasives, solvents or clean-
ing agents containing carbon, alcohol or
benzenes on the monitor.
• Do not drop the monitor.
• Repairs or services not covered in this
manual should be performed by qualied
personnel only. Please contact Sper
Scientic to speak with a technician.
• Use only the recommended battery when
replacement is needed.

14
SPECIFICATIONS
Range Res. Accuracy
Temp. -22 to 158°F
-30 to 70°C
0.1°F/C ±1.0°F
±0.5°C
RH 0.1 to 80% 0.1% ±3% (@25°C & 10
to 80% RH)
otherwise ±5%
Barometric
pressure
300 to
1100 hPa
8.9 to
32.5 inHg
0.1 hPa
0.1 inHg
±3 hPa (0 to 60°C)
±5 hPa (-20 to 0°C)
Battery type CR2
Battery life 72 Days
Dimensions 3” x 2” x 1” (78 x 50 x 23 mm)
Weight 2.3 oz (66 g) (with battery)
Data points 16000 per parameter

15
WARRANTY
Sper Scientic warrants this product against
defects in materials and workmanship
for a period of one (1) year from the
date of purchase, and agrees to repair or
replace any defective unit without charge.
If your model has since been discontinued,
an equivalent Sper Scientic product will
be substituted if available. This warranty
does not cover batteries, battery leakage, or
damage resulting from accident, tampering,
misuse, or abuse of the product. Opening the
meter to expose its electronics will void the
warranty. To obtain warranty service, ship the
unit postage prepaid to:
SPER SCIENTIFIC LTD.
8281 E. Evans Rd., Suite #103
Scottsdale, AZ 85260
(480) 948-4448
The defective unit must be accompanied by
a description of the problem and your return
address. Register your product online at
www.sperwarranty.com within 10 days of
purchase.
Please note: The most current version of the manual
can always be found at www.sperdirect.com

16
rev. 8/7/2019
Table of contents
Other Sper scientific Data Logger manuals