INSTALLATION
Please read before installing this equipment. Failure to do so may void your
warranty.
Installation
The 801 and 802 ow meters give the best accuracy when there is a smooth,
unobstructed ow through it. To minimize turbulence, there should be at least
12″/30cm of straight plumbing upstream from the ow meter and at least
6″/15cm of straight plumbing downstream from the ow meter. Mount the ow
meter in a location that physically protects it from damage and allows liquid to
drain away after the sprayer is ushed and secured at the end of the operating
day. A straight, vertical section of the main boom supply line is the ideal location
for the ow meter.
Keep the ow meter from lying in a low section of the sprayer plumbing.
This is particularly important in cold weather when water might freeze in the
ow meter and cause damage to the unit. It is also important when applying
chemical suspensions which may settle out and stall the ow meter turbine if
they cannot drain away.
Before installing the ow meter insert, make sure there are no obstructions in
the insert cavity. Clearance at the bottom of the cavity is very close and over
compressing of foreign material in the cavity can cause damage to the ow
meter body. For 801, turn the insert locking collar until it is hand tight. For 802
install the ow meter insert until the pin openings are aligned.
Prior to each day’s spraying, the ow meter should be inspected to ensure there
are no leaks around the attachment ttings. At the end of the day, care should
be taken to thoroughly ush the ow meter with clean water.
Make sure no water or sediment is trapped in the flow meter
The impeller type ow meters supplied by TeeJet Technologies are inherently
rugged. However, continued use over time will eventually wear the internal
bearings and shafts until the meter becomes inaccurate. Replacement kits are
available to repair the ow meters. Contact your TeeJet Technologies dealer for
these parts.
801/802 FLOW METERS
INSTALLATION, SPECIFICATION, AND WARRANTY INFORMATION
801 & 802 FLOW METERS
O-Ring
Bolt
Sensor
Hose Barb
Flow Meter Sensor
Main Flow Meter Body
Flanged
Clamp
>12"/30cm
> 6"/15cm
Main Product
Pump
Bypass Line
Auto Range®
Valve
Pump Discharge
Flow Meter
To Booms
NOTE: The Flow Meter
must be mounted so that
it will drain completely
when the sprayer is not
operating
Connector, Deutsch 3 Pos/Skts
Pin Out Color Function
A Red +4.5V to 16V
BWhite Signal
C Black Ground
Connector, Conxall 3 Pos/Pins
Pin Out Color Function
1Black Ground
2White Signal
3 Red +5V
98-01087-ENUS R5 English-US
© TeeJet Technologies 2014 www.teejet.com
INSTALLATION
Specications
Measuring Data 801 Flow Meter 802 Flow Meter
Linearity at recommended ow range +/- 3.0% +/- 3.0%
Flow Range 2-60 GPM (7.5-225 LPM)
(3-30 GPM recommended for max life)
3-130 GPM (10-495 LPM)
(5-110 GPM recommended for max life)
Maximum Working Pressure 300 PSI (20.7 Bar) 200 PSI (14 Bar)
Pressure Drop 10 GPM (37.85 LPM) - NA
20 GPM (75.71 LPM) - 3 PSI (0.21 Bar)
30 GPM (113.56 LPM) - 7.5 PSI (0.52 Bar)
40 GPM (151.42 LPM) - 12.5 PSI (0.86 Bar)
50 GPM (189.27 LPM) - 19.5 PSI (1.34 Bar)
60 GPM (227.12 LPM) - 29 PSI (2.0 Bar)
30 GPM (113.56 LPM) - NA
60 GPM (227.12 LPM) - 1 PSI (0.07 Bar)
100 GPM (378.54 LPM) - 3 PSI (0.21 Bar)
130 GPM(492.10 LM) - 5 PSI (0.34 Bar)
Measuring range is partly dependent on the selected type and size of connectors.
The flow meter is bidirectional for mounting purposes.
Electrical Data 801 Flow Meter 802 Flow Meter
Sensor Open collector NPN
50% square wave
10-300 Hz in operating range
Open collector NPN
50% square wave
10-300 Hz in operating range
Calibration Number (Approximate) TeeJet Controller - 82 pulses/liter
Mid-Tech Controller - 310 pulses/gallon
Raven Controller - 820 pulses/10 liter
Raven Controller - 3100 pulses/10 gallons
TeeJet Controller - 21 pulses/liter
Mid-Tech Controller - 79 pulses/gallon
Raven Controller - 210 pulses/10 liter
Raven Controller - 790 pulses/10 gallons
LED Indicators Green-Power
Orange-Signal
Green-Power
Orange-Signal
Measuring Data 801 and 802 Flow Meters
Body & Insert 30% glass lled polypropylene
Shaft 410 hardened stainless steel
Turbine & Bearing Support 20% talc lled polypropylene
Bearing Sapphire
Bearing Housing 303 stainless steel
Warranty
The warranty on this equipment may be affected for the following reasons:
• Improper installation
• Obvious abuse
• Lack of, or improper maintenance
• Employed in a manner inconsistent with its intended use
• Used with chemicals that are incompatible with the materials which this product is made of
(See “Warranty and Limitations” statement in your controller manual for other limitations)
This ow meter is manufactured using some or all of the following materials:
• 303 Stainless Steel
• 410 Stainless Steel
• Polypropylene
TeeJet Technologies does not recommend metering any product that reacts with these materials and damage resulting from the use of such products will not be
covered under the warranty. Please contact your chemical supplier to verify that the chemicals you are using are compatible.
If you have any questions about installation or use, refer to the installation section of your manual or call your TeeJet Technologies dealer.

This manual suits for next models

1

Popular Measuring Instrument manuals by other brands

RTW 11528G operating manual

RTW

RTW 11528G operating manual

SMC Networks PPA100 Series instruction manual

SMC Networks

SMC Networks PPA100 Series instruction manual

Greenlee 5990A instruction manual

Greenlee

Greenlee 5990A instruction manual

Extech Instruments SDL800-NIST user guide

Extech Instruments

Extech Instruments SDL800-NIST user guide

Agilent Technologies 3200P user guide

Agilent Technologies

Agilent Technologies 3200P user guide

Teledyne PEM-9004 operating instructions

Teledyne

Teledyne PEM-9004 operating instructions

Banjo MFM100 manual

Banjo

Banjo MFM100 manual

Endress+Hauser Liquiline System CA80NO Brief operating instructions

Endress+Hauser

Endress+Hauser Liquiline System CA80NO Brief operating instructions

Precision Digital Corporation ProtEX-MAX PD8-6200 Series instruction manual

Precision Digital Corporation

Precision Digital Corporation ProtEX-MAX PD8-6200 Series instruction manual

Delmhorst J-Lite owner's manual

Delmhorst

Delmhorst J-Lite owner's manual

Kübler CODIX 52P operating instructions

Kübler

Kübler CODIX 52P operating instructions

Sanwa DCL1000 instruction manual

Sanwa

Sanwa DCL1000 instruction manual

Eaton Cutler-Hammer Enclosed IQ Instruction leaflet

Eaton

Eaton Cutler-Hammer Enclosed IQ Instruction leaflet

MuxLab 500831 Installation & operation manual

MuxLab

MuxLab 500831 Installation & operation manual

Konica Minolta CM-700d manual

Konica Minolta

Konica Minolta CM-700d manual

Electronic 63 quick start guide

Electronic

Electronic 63 quick start guide

GE Grid Solutions Multilin 9450 instruction manual

GE Grid Solutions

GE Grid Solutions Multilin 9450 instruction manual

TFA LM 40 instruction manual

TFA

TFA LM 40 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.