!"#$%&'!"#$#&(!)*+),(!-.*/(!01.*(23.*4)(205/*011)*(
6,)*(7.58.1(
(
%9 7.+5(:)./8*),(
1) The&design&of&IP68&waterproof&level&and&aluminum&shell&helps&effectively&prevent&erosion.& &
2) 12&V/24&V&system&voltage.&
3) LED&numeric&display&and&waterproof&keys&are&easy&to&use.&
4) An&upgraded&3-stage&PWM&charging&algorithm&applies&an&equalizing&charge&to&the&battery&every&week,&effectively&preventing& &&&&&&&&&&&&&&
the&battery&from&non-equalization&and&sulfuration&and&therefore&extending&the&battery's&service&life.&
5) Up&to&5&load&working&modes&facilitate&the&product's&application&to&different&types&of&road&lamps&and&monitoring&devices.&
6) Charging& program& options& are& available& for& sealed,& GEL&and& flooded&lead-acid& batteries& and& ternary-material& lithium& and&
lithium&iron&phosphate&batteries.& &
7) An&external&temperature&sensor&helps&deliver&high-precision&temperature&compensation.& &
8) Parameter&settings&of& power-down& saving& functions&eliminate&the&trouble&of& repeated&settings,&making&operation& easy& and& &&
convenient.& &
9) Various&kinds&of&state&indicators.& &
10) Overcharge,&over-discharge&and&overload&protection,&as&well&as&short-circuit&and&reverse-connection&protection.&
11) TVS&lighting&protection.& &
#9 ;5,/.11./+05(.5<(=+*+54(
1. The&controller&shall&be&installed&securely,&and&its&dimensions&are&as&follows:& &
External&dimensions:&82×58×20&(mm)/&2410;&82×100×20&(mm)/&2420&
Installation&dimensions:&43×75&(mm)/&2410;&82×75&(mm)/&2420&
Installation&hole&diameter:&3.5&(mm)&
&
&
&
&
&
&
(
(
(
(
2. The&SL&series&controller&can&work&under&a&system&voltage&of&12&V&or&24&V.&In&actual&practice,&connect&the&battery&first,&and&the&
controller&starts&operation&after&automatically&recognizing&the&battery&voltage.&For&a&12&V&system,&the&nixie&tube&displays&"0.&".&&
For&a&24& V& system,&the&nixie&tube&displays&"1.& "&and&battery&indicator&lights&up;& otherwise,&check& whether&the&connection&is&
correct.&
3. Connect&the&solar&panel's&"+"&and&"-"&poles.&If&sunlight&is&present,&the&solar&panel&indicator&lights&up;&otherwise,&check&whether&
the&connection&is&correct.& &
4. Connect&the&load's&"+"&and&"-"&poles.&Connect&the&load&leads&to&the&controller's&load&output&terminal,&and&the&current&shall&not&
exceed&the&controller's&rated&current.&
The&wiring&is&shown&below:&
&
&
>9 6,.4)(?)@0--)5<./+05,(
1) When&the&controller&is&powered&on,&it&automatically&recognizes&the&battery&voltage.&In&practical&use,&connect&the&battery&first,&
and&make&sure&the&connection&is&sound&and&reliable.&
2) As& the& controller& generates& heat& during& operation,& you& are& advised& to& install& it& in& an& environment& with& good& ventilation&
conditions.& &
3) The& controller& measures& the& ambient& temperature& and& makes& compensation& to& battery& charging& based& on& the&
measurement.&As&long&as&actual&conditions&permit,&place&the&battery&and&the&controller&in&the&same&environment.& & &
4) Choose&cables&with&large&enough&capacity&for&connection,&in&case&too&much&loss&incurred&on&the&lines&causes&the&controller&to&
misjudge.&
5) The&controller&has&a&common&positive&pole&inside.&If&grounding&is&needed,&ground&the&positive&pole.&
6) It's&important&to&fully&charge&the&battery&regularly.&At&least&one&full&charging&in&every&month&is&recommended,&and&failure&to&
do&that&may&cause&permanent&damage&to&the&battery.&Only&when&inflow&energy&outpaces&outflow&energy&can&the&battery&be&
charged&full.&Users&shall&bear&this&in&mind&when&configuring&the&system.&
$9 !/./)(;5<+@./0*,(
"AB("+43/(
;5<+@./)<(;/)-(
!/./)(
7).5+54(
(
Charging& &
& &
Steady&on& & &
Solar&panel&of&voltage&
Steady&off& & &
Solar&panel&of&no&voltage&
Slow&
flashing& & &
Charging&in&process&
Quick&
flashing& &
System&over&voltage&
(
Battery&
& &
Steady&on& & &
Normal&battery&function&
Steady&off& & &
Battery&not&connected&
Slow&
flashing& & &
Battery&under&voltage&
Quick&
flashing& &
Battery&over&discharged&
(
Load&
& &
Steady&on& & &
Load&turned&on&
Steady&off& & &
Load&turned&off&
Slow&
flashing& & &
Overload&protection&
Quick&
flashing& &
Short-circuit&protection&
C9 70<)(B),@*+D/+05(.5<(!)//+54,(E.F1)( ( (
The&SL2410/20&series&controller&has&5&working&modes,&and&specific&settings&are&listed&in&the&table&below.& &
%9 G8*)(1+43/( @05/*01( H&I:& When& sunlight& disappears& and& light& intensity& drops& to& the& starting& point,& the& controller& initiates& a&
10-minute&delay&to&confirm&the&starting&signal,&and&then&switches&on&the&load&for&operation&according&to&parameter&settings.&When&
sunlight& emerges& and& light& intensity& reaches& the& starting& point,& the& controller& initiates& a& 10-minute& delay& to& confirm& the&
shutting-down&signal,&and&then&shuts&down&the&output&to&stop&the&load's&operation.&
#9 "+43/( @05/*01( J( /+-)( @05/*01( H%( /0( $9I:The&starting&process&is&the&same&as&the&pure&light&control.&After&operating&for& a&preset&
period&of&time&(settable&from&1&to&14&hours),&the&load&turns&off&automatically.& &
>9 7.58.1(-0<)(HC9I:(In&this&mode,&the&user&can&switch&the&load&on&or&off&by&operating&the&keys,&regardless&of&daytime&or&night.&
This&mode&is&designed&for&some&specially&purposed&loads,&and&also&used&in&the&debugging&process.& & &
$9 B)F844+54( -0<)( HK9IL( used& for& system& debugging.& With& light& signals,& the& load& is& shut& off;& without& light& signals,& the& load& is&
switched&on.&This&mode&enables&fast&check&of&the&correctness&of&system&installation&during&installation&and&debugging.& &
C9 Normal&on&mode&(7.):&The&energized&load&keeps&in&output&state,&and&this&mode&is&suitable&for&loads&which&need&24-hour&power&
supply.& &
&
"AB(B+,D1.M(
70<)(
"AB(B+,D1.M(
70<)(
0&
Pure&light&control&
mode&
9&
Light&control&+&time&
control&(9&hours)&
1&
Light&control&+&time&
control&(1&hour)&
0.&
Light&control&+&time&
control&(10&hours)&
2&
Light&control&+&time&
control&(2&hours)&
1.&
Light&control&+&time&
control&(11&hours)&
3&
Light&control&+&time&
control&(3&hours)(
2.&
Light&control&+&time&
control&(12&hours)&
4&
Light&control&+&time&
control&(4&hours)(
3.&
Light&control&+&time&
control&(13&hours)&
5&
Light&control&+&time&
control&(5&hours)&
4.&
Light&control&+&time&
control&(14&hours)&
6&
Light&control&+&time&
control&(6&hours)&
5.&
Manual&mode&
7&
Light&control&+&time&
control&(7&hours)&
6.&
Debugging&mode&
8&
Light&control&+&time&
control&(8&hours)&
7.&
Normal&on&mode&
K9 !)//+54(7)/30<,(
"0.<(N0*O+54(-0<)(,)//+54(-)/30<L(
Press&the&key&for&no&less&than&3s,&and&the&nixie&tube&begins&to&flash,&indicating&that&the&system&can&be&adjusted.&Release&the&key&and&
every& time& you& click& it,& the& number& displayed& on& the& nixie& tube& changes& to& another.& When& the& number& becomes& the& one& that&
corresponds&to&the&mode&selected&by&the&user,&wait&until&the&nixie&tube&stops&flashing&or&press&the&key&again&for&no&less&than&3s&to&
complete&the&setting.& &
P.//)*M(/MD)(,)//+54(-)/30<L(
In&the&[5.]&mode,&press&the&key&for&3s,&and&the&nixie&tube&begins&to&flash.&Release&the&key,&and&long&press&the&key&again.&The&three&
LED&lights&and&nixie&tube&begin&to& flash.&Then,& click&the& key&to&choose&a& battery&type&by&the&numeric&value&displayed&on& the&nixie&
tube.&After&that,&long&press&the&key.&When&the&indicator&lights&stop&flashing,&the&setting&is&complete&and&nixie&tube&exits&to&the&[5.]&
mode.& &
Q+R+)(/8F)(
B+,D1.M(
P.//)*M(EMD)(
Q+R+)(E8F)(
B+,D1.M(
P.//)*M(EMD)(
1&
Sealed&lead-acid&battery&
5&
4&strings&of&
ternary-material&lithium&
batteries&
2&
GEL&lead-acid&battery&
6&
7&strings&of&
ternary-material&lithium&
batteries&
3&
Flooded&lead-acid&battery&
7&
4&strings&of&lithium&iron&
phosphate&batteries&
4&
3&strings&of&ternary-material&
lithium&batteries(
8&
8&strings&of&lithium&iron&
phosphate&batteries&
S9 G.*.-)/)*(B)/.+1,(
&
For& the& above& parameters,& the& ambient& temperature& is& 12& °C,& the& system& voltage& is& 12& V,& and& the& lithium& battery&
parameters&are&single-piece&ones.& &
T9 20--05(G*0F1)-,(.5<(!018/+05,(
!M-D/0-,(
2.8,),(.5<(,018/+05,(
While&sunlight&is&present,&the&solar&panel&
indicator&does&not&light&up.&
Check&whether&the&solar&panel&is&correctly&connected&and&contact&is&
good&and&reliable.&
The& solar& panel& charging& indicator& is&
flashing&quickly.&
&
System&overvoltage.&Check&whether&the&battery&voltage&is&too&high.&
The& solar& panel& indicator& is& off& and&
battery&voltage&is&normal,&but&there&is&no&
output.& &
&
&
The&load&will&be&switched&on&automatically&after&10&minutes.&
&
The&battery&indicator&does&not&light&up.&
The& battery& may& be& failing& to& supply& power.& Check& whether& the&
battery&is&correctly&connected.&
The& battery& indicator& is& flashing& quickly,&
The& battery& is& over-discharged,& and& will& recover& when& recharged&
P.//)*M(/MD)(
Sealed&
GEL&
Flooded&
Ternary-material&
lithium&
Lithium&iron&
phosphate&
!M,/)-(@8**)5/(
10&A;&20&A&
Q0U10.<(10,,( (
10&mA/&12&V;&13&mA/&24&V&
!01.*()5)*4M(+5D8/(
V01/.4)(
<&55&V&
!M,/)-(V01/.4)(
12&V/&24&V&
Auto&
12&V/&24&V&
Auto&
12&V/&24&V&
Auto&
3&and&4&
strings:&12&V&
system&
7&strings:&24&V&
system&
4&strings:&12&V&
system&
8&strings:&24V&
system&
WV)*V01/.4)(
D*0/)@/+05(
17.0&V&
17.0&V&
17.0&V&
4.2&V&*&N&+&
2.0&V&
3.65&V&*&N&+&
2.0&V&
AX8.1+Y+54( @3.*4+54(
V01/.4)(
14.6&V&
—&
14.8&V&
—&
—&
P00,/( @3.*4+54(
V01/.4)(
14.4&V& &
14.2&V& &
14.6&V& &
—&
—&
:10./+54(@3.*4+54(
V01/.4)( (
13.8&V&
&&&&13.8&V&
13.8&V&
&&&&&& —&
—&
WV)*@3.*4)(V01/.4)(
—&
&&&&&—&
—& &
4.2&V&*&N&
3.65&V&*&N&
WV)*@3.*4)(*)@0V)*M(
—&
&&&&&—&
—&
3.9&V&*&N&
3.4&V&*&N&
P00,/(@3.*4+54(
*)@0V)*M(V01/.4)(
13.2&V&
13.2&V&
13.2&V&
—&
—&
WV)*U<+,@3.*4)(
*)@0V)*M(V01/.4)( (
12.5&V&
12.5&V&
12.5&V&
3.3&V&*&N&
3.0&V&*&N&
65<)*V01/.4)( (
12.0&V&
12.0&V&
12.0&V&
3.2&V&*&N&
2.8V&*&N&
WV)*U<+,@3.*4)(
V01/.4)( (
11.0&V&
11.0&V&
11.0&V&
3.0&V&*&N&
2.5&V&*&N&
E)-D)*./8*)(
@0-D)5,./+05(
-4.0&mv/°C/&2&V&
&
—&
—&
AX8.1+Y+54(@3.*4+54(
<8*./+05( (
1&hour& &
—&
1&hour&
—&
—&
P00,/(@3.*4+54(
<8*./+05( (
4&hours&
4&hours&
4&hours&
—&
—&
"+43/(@05/*011)<(
V01/.4)(
Light&controlled&on&5&V,&light&controlled&off&6&V&
"+43/(@05/*01(
Z8<4-)5/(/+-)(
1&min&
WV)*10.<(.5<(
,30*/U@+*@8+/(
D*0/)@/+05(
1.25&times&of&rated&current:&30&s;& &
1.5&times&of&rated&current:&5&s&of&overload&protection;&
Over&3&times&of&rated&current:&short-circuit&protection.&
WD)*./+54(
/)-D)*./8*)(
-35°C&to&+65°C;&
G*0/)@/+05(<)4*))(
IP68&
=)+43/(
140&g&(10&A)& & & & & & & & & & & & & 300&g&(20&A)&
B+-)5,+05,(
82×58×20&(mm)/&10&A;&82×100×20&(mm)/&20&A&
(L×W×H)&
and&there&is&no&output.&
adequately.&
The&load&indicator&is&flashing&slowly,&and&
there&is&no&output.&
The&load&power&exceeds&the&rated&power.&Reduce&power-consuming&
devices&and&long&press&the&key&to&recover.&
The&load&indicator&is&flashing&quickly,&and&
there&is&no&output.&
The&load&is&short-circuited.&After&removing&the&problem,&long&press&
the&key&or&wait&until&it&recovers&automatically&the&next&day.&
The&load&indicator&is&steady&on,&and&there&
is&no&output.&
Check& whether& the& power-consuming& devices& are& connected&
correctly&and&reliably.&
&
Other&symptoms&
Check&whether&the&wiring&is&sound&and&reliable&and&system&voltage&
(12&V/&24&V)&is&correctly&recognized.&
(
E3)(@05/)5/,(0[(/3+,(-.58.1(.*)(,8FZ)@/(/0(@3.54)(N+/308/(D*+0*(50/+@)9(

Other manuals for SL2410

1

This manual suits for next models

1

Other Srne Controllers manuals

Srne MD Series User manual

Srne

Srne MD Series User manual

Srne ML4860 User manual

Srne

Srne ML4860 User manual

Srne SR-LG Series User manual

Srne

Srne SR-LG Series User manual

Srne ML2440N10 User manual

Srne

Srne ML2440N10 User manual

Srne ML2420 User manual

Srne

Srne ML2420 User manual

Srne SL2410 User manual

Srne

Srne SL2410 User manual

Srne ML4860N15 User manual

Srne

Srne ML4860N15 User manual

Srne ML Series User manual

Srne

Srne ML Series User manual

Srne ML Series User manual

Srne

Srne ML Series User manual

Srne HM-CU Series User manual

Srne

Srne HM-CU Series User manual

Popular Controllers manuals by other brands

Rice Lake iRite 920i Operation manuals

Rice Lake

Rice Lake iRite 920i Operation manuals

US drives PHOENIX EX instruction manual

US drives

US drives PHOENIX EX instruction manual

Lenel LNL-1300-U quick reference

Lenel

Lenel LNL-1300-U quick reference

Omron CV/CVM1 Replacement guide

Omron

Omron CV/CVM1 Replacement guide

Evco Vcolor 338 Installer manual

Evco

Evco Vcolor 338 Installer manual

FlowLine Switch Pro A 1 Series owner's manual

FlowLine

FlowLine Switch Pro A 1 Series owner's manual

Kübler CODIX 555 manual

Kübler

Kübler CODIX 555 manual

Sinope RM3250ZB-C4 installation guide

Sinope

Sinope RM3250ZB-C4 installation guide

SainSmart 2M542 operating manual

SainSmart

SainSmart 2M542 operating manual

iNels DA3-22M instruction manual

iNels

iNels DA3-22M instruction manual

Johnson Controls TC-8902 installation instructions

Johnson Controls

Johnson Controls TC-8902 installation instructions

McCain ATC eX2 NEMA user manual

McCain

McCain ATC eX2 NEMA user manual

Signaline SKM-95 instruction manual

Signaline

Signaline SKM-95 instruction manual

Jandy AquaLink RS All Button Quick review card

Jandy

Jandy AquaLink RS All Button Quick review card

Pride Controller GC2 Operation instructions

Pride

Pride Controller GC2 Operation instructions

Linak LA12 user manual

Linak

Linak LA12 user manual

Mitsubishi Electric LGF-100GX-E Handbook

Mitsubishi Electric

Mitsubishi Electric LGF-100GX-E Handbook

MULTISPAN PID 2303-3C manual

MULTISPAN

MULTISPAN PID 2303-3C manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.