Expansion Rack
Unit name CV/CVM1 series CS-series Description
Power Supply Units CV500-PS221
CVM1-PA208 C200HW-PA209R
C200HW-PA204R
C200HW-PA204
C200HW-PA204C
AC type
Note: RUN Output cannot be used on Expansion Backplanes.
CV500-PS211 C200HW-PD024
C200HW-PD025 DC type
Note: No RUN output type provided.
Backplanes
(Expansion Backplanes) < CPU Expansion Backplane
>
CV500-BI111(11slot)
< I/O Expansion Backplane >
CV500-BI042(4 slots)
CV500-BI062(6 slots)
CV500-BI112(11 slots)
CVM1-BI064(6 slots)
CVM1-BI114(4 slots)
[ I/O Backplanes for C500 ]
C500-BI***
CS1W-BI033/BI032 (3 slots)
CS1W-BI053/BI052 (5 slots)
CS1W-BI083/BI082 (8 slots)
CS1W-BI103/BI102 (10 slots)
*
Both CS1 Units and C200H Units can be used for CS1W-BC[][]3.
Only CS1 Units can be used for CS1W-BC[][]2. C200H Units cannot be used.
*When an I/O Control Unit for long distance expansion is mounted, the number of Units that can be
mounted on the backplane will decrease by one.
Expansion Units
(I/O Interface Units) CV500-II101
CV500-II201
C500-II002
CS1W-IC102
(I/O Control Unit for long
distance expansion)
or
Unnecessary (when total
expansion length is 12 m or
less.)
The I/O Control Unit for long distance expansion is necessary when the total expansion cable length
exceeds 12 m.
(The Unit can be used even if the total expansion legth is 12 m or less. You can also directly
connect the expansion cable to the Backplane without using an I/O Control Unit.)
Note: When an I/O Control Unit is mounted, the number of available slots decreases by one.
Connecting Cables for
Expansion Backplanes < CPU Bus Cable >
CV500-CN311 (30 cm)
CV500-CN611 (60 cm)
< CS/CJ I/O Connecting
Cables >
CS1W-CN313 (30 cm)
CS1W-CN713 (70 cm)
CS1W-CN223 (2 m)
The cable connects a CS-series CPU Rack or Extension Rack with another Expansion Rack.
With CV/CVM1, you have to connect two cables between a CPU Unit and an Expansion Rack: one
is this connecting cable and the other is an I/O Cable.
With CS/CJ-series, you need only one cable, i.e. an I/O connection cable for CS/CJ.
<CV-series I/O Connecting
Cables: Connects CS-series
Long distance Expansion
Racks.>
CV500-CN312 (30 cm)
CV500-CN612 (60 cm)
CV500-CN122 (1 m)
CV500-CN222 (2 m)
CV500-CN322 (3 m)
CV500-CN522 (5 m)
CV500-CN132 (10 m)
CV500-CN232 (20 m)
CV500-CN332 (30 m)
CV500-CN432 (40 m)
CV500-CN532 (50 m)
An Expansion Unit and a cable for long distance expansion are required when the total length of the
expansion cable exceeds 12 m.
Reference: The CS-series uses CV/CVM1-series I/O Cables for long distance expansion. You can
reuse them when you replace the CV/CVM1-series. The number of available slots, however,
decreases by one bacuase CS-series uses I/O Control Unit for long distance expansion.
Note: If you want to use the existing connecting cables for Expansion Backplanes, be sure to check
the conditions of the cables.
-Check for disconnected wire or wire that can be easily disconnected.
-Check for rust or corrosion.
-Check for damage of connectors (The connector must be inserted and fixed firmly.)
< I/O Cable >
CV500-CN312 (30 cm)
CV500-CN612 (60 cm)
CV500-CN122 (1 m)
CV500-CN222 (2 m)
CV500-CN322 (3 m)
CV500-CN522 (5 m)
CV500-CN132 (10 m)
CV500-CN232 (20 m)
CV500-CN332 (30 m)
CV500-CN432 (40 m)
CV500-CN532 (50 m)
< CS/CJ I/O Connecting
Cables >
CS1W-CN313 (30 cm)
CS1W-CN713 (70 cm)
CS1W-CN223 (2 m)
CS1W-CN323 (3 m)
CS1W-CN523 (5 m)
CS1W-CN133 (10 m)
CS1W-CN133-B2 (12 m)
With the CS series, no Expansion Unit is necessary if the total length of expansion cable is 12 m or
less. You can connect the cable directly to the Backplane.
<I/O Cable (for connecting
single Expansion I/O Rack via
Backplanes)>
CV500-CN413 (40cm)
CV500-CN613 (60cm)
< CS/CJ I/O Connecting
Cables >
CS1W-CN313 (30 cm)
CS1W-CN713 (70 cm)
CS1W-CN223 (2 m)
An I/O Control Unit is unnecessary for expansion.
<I/O connecting cable for
C500>
C500-CN312N (30cm)
C500-CN512N (50cm)
C500-CN812N (80cm)
C500-CN122N (1m)
C500-CN222N (2m)
< I/O connecting cables for
CS/CS >
CS1W-CN313 (30 cm)
CS1W-CN713 (70 cm)
CS1W-CN223 (2 m)
An I/O Control Unit is unnecessary for expansion.
Electrical Isolation
Sleeve
(CV500-ATT04/ATT05)
CV500-ATT04
CV500-ATT05 Unnecessary The noise-preventing spacer is unnecessary for CS, because CS Units are installed by isolating
from the control panel.
I/O Units & Special I/O Units
Unit name CV/CVM1 series CS-series Description
Basic I/O Units C500-ID/IA/IM[][][]
C500-OD/OC/OA[][][]
C500-MD[][][]
CS1W-ID/IA/IM[][][]
CS1W-OD/OC/OA[][][]
CS1W-MD[][][]
or
C200H-ID/IA/IM[][][]
C200H-OD/OC/OA[][][]
C200H-MD[][][]
Use CS or C200H Basic I/O Units.
The terminal block wirings and input/output specifications are different with some Units.
To improve maintainability, it is recommended that you renewal the system with CS-series Units.
Special I/O Unit C500-[][][][]
CS1W-[][][][]
or
C200H-[][][][]
Use CS or C200H Special I/O Units.
Replacement in this method involves change of the terminal block wirings and internal specifications.
To improve the system performance and maintainability, it is recommended that you renewal the
system with Special I/O Unit for CS-series.
4