05 06
3.4. Remote switch
3. Parameter Setting
3.1 [A] Protector Mode
3.2 [U] System voltage
3.3 [P] Protection level
Display Setting range Meaning
AC (default) Charge protector
LDischarge protector
Display Setting range Meaning
U
0. Automatic identification
1. 12V
2. 24V
3. 36V
4. (default) 48V
Display Setting range Over-voltage
protection
Over-voltage
protection
recovery
Over-discharge
voltage Over-discharge
restoring voltage Remarks
P
0 15,0V 14.0V 10,7V 12,2V
Customized
1(default) 15,0V 14.0V 10,7V 12,2V
Fixed
value
2 15,5V 13.8V 10,9V 12,4V
3 16,0V 13.6V 11,1V 12,6V
4 16,5V 13.4V 11,3V 12,8V
5 17,0V 13.2V 11,5V 13,0V
Protection/
recovery delay Immediate
response 2s 2s
Configurable
when customized
2s 2s
The parameters shown in the table are for the condition of 25°C/12V, and it should be multiplied
by 2/3/4 for the battery systems with voltages of 24V/36V/48V.
[Charge protector]: Only over-voltage protection value is used up to.
[Discharge protector]: Both over-voltage protection value and over-discharge protection value
are used up to.
[Customized mode]: After the number set to "0", the protection value and over-discharge delay
time can be customized through communication.
[1-5]: Delays are fixed to 2 seconds for overvoltage recovery, over-discharge, and over-
discharge recovery.
Connect: charging or discharging
Disconnect: stop charging and discharging
3.5 Restore to factory settings
Hold down the button for at least 20 seconds until the 7-segment display shows "8.",
then release the button to restore to factory settings.
Restore default items Restore default Default Function
Protector type CCharge protector
System voltage 4. 48V
Protection level 1Refer to" 3.3 "
Operating Statistics Data clearing --
3.6 System indications
Display Meaning
Slow blinking (over-discharge: stop charging and
discharging)
Fast blinking(over voltage: stop charging and discharging)
Fast blinking (over-temperature: stop charging and
discharging)
(The over-temperature of the system is 70°C, The system
will recover when the temperature is below 65°C.)
Slow blinking (Remote switch is disconnect: stop
charging or discharging)
The light turn on for 1s when the system is powered on
and the first communication is connected.
Constant blinking (the protector is working)
4. Button Functions
Button Function
Short press Parameter switching / Mode selection / Setting data increment;
Hold down Hold down: Enter/Exit parameter setting