SRS Labs ADR24-DIGI-AHD User manual

( 1 / 18)
Instruction Manual
Models:
version 3.1 since 7 June 2019
ATTENTION!
This instruction manual contains important information about the installation and the use of
the equipment. Please read and follow these instructions carefully.
Always ensure that the power to the equipment is disconnected before opening the
equipment or commencing any maintenance wor .
ADR-DIGI-AHD_manual_M327.doc
Advanced igital Remote
for Hoist Controller
A R24- IGI-AH
A R36- IGI-AH
A R48- IGI-AH

( 2 / 18)
Safety information
IMPORTANT INSTRUCTIONS
All safety and operating instructions should be read before the equipment is installed or operated.
IMPORTANT SAFETY INFORMATION
The following general safety precautions have to be observed during all phases of operation, service,
and the repair of this equipment. Failure to comply with these precautions or with specific warnings
in this manual violates safety standards of design, manufacture, and the intended use of this
equipment.
Do not operate in an explosive atmosphere!
Do not operate this equipment in the presence of flammable gases or fumes. Operation of any
electrical instrument in such an environment constitutes a definite safety hazard.
ater, moisture, heat and humidity
Do not operate this equipment near water or in areas with wet floors or in high humidity atmosphere,
where condensation forms on the equipment. It should never be placed near or over a heat register
or other source of heated air and it should not be installed or operated without proper ventilation.

( 3 / 18)
Operation
The ADR-DIGI-AHD is manufactured from as 24/36/48 channels and it suits as directional remote for
digital controllers. The ADR-DIGI-AHD Motors/Hoists connected to the GMDseries and AHDseries
controller can be activated individually or simultaneously using the GO button located on the ADR-
DIGI-AHD cable. Unit is also equipped with LCD display and encoder wheel with buttons to simplify
setup and operation of system.
How to start
Connect a 5-pin NC5MXX plug to the remote input of the ADR-DIGI-AHD unit.
Chec if the emergency STOP button on both AHD devices is released. If not, this state will
be indicated by the STATUS LED blin ing in red color. Chec STOP buttons on all connected
controllers. Rotate them cloc wise to release and RESET units
Move the lever on ADR-DIGI-AHD corresponding to each motor to the desired position.
According to the position of lever, hoists act as follows:
o UP - Lever in upper position
o STAY – Lever in middle position
o DOWN - Lever in lower position
Pushing the GO button will activate the motors and move them simultaneously.
Releasing the GO button will stop the movement of the motors simultaneously.
When the device is not in use, it is highly recommended to push E-STOP mushroom or TURN
off units via ey on front panel of AHD controller
To Move a Single Motor:
Set the UP/DOWN toggle switch for desired motor to the desired direction. The associated
LED will illuminate green for UP and red for DOWN direction.
Hold the GO button until the motor(s) is/are moved to the desired height, then release.
To Move Several Motors:
Set the UP/DOWN toggle switches for each motor to the desired direction. The associated
LEDs will illuminate green for UP and red for DOWN direction.
Hold the GO button until the motors are moved to the desired height, then release.

( 4 / 18)
ADR-DIGI-AHD series remote
CMC-DIG-AHDseries remote allows controlling of the AHDseries and GMDseries via digital 5-pin cable
connector. During standard operation, the full 5core cable must be equipped with Neutri 5-pin
connectors. Maximum cable length is 1000m. The data connection is performed via RS485
communication line.
ADR24--DIGI-AHD wit wall-mount ears

( 5 / 18)
E-STOP:
This switch protects the operation of the base unit from undesired operation and its press turns the
Controller to an inactive state. E-STOP is a red color button. Once the E-STOP button has been
pressed, system is loc ed in an inactive position and the button must be rotated cloc wise to be
released to continue operation.
GO:
This green button turns the selected channels of Hoist Control system ON when it is active. Once
the GO button has been depressed, the energizing of the hoists is turned off. GO button is blin ing
when status of system is activated and you’re able to move hoist
DIRECTION SWITCHES:
They allow changing the direction of movement for each motor/hoist separately or in groups. The
LED located close to the switch indicates the direction of movement.
DIRECTION SWITCH LED
Green UP
Red DOWN
No light stays in position
STATUS LED
GREEN Device ready for action
RED Indicates that the GO button is active
ORANGE Indicates the activity of direction switch, LED blin s in movement
E-STOP LED
GREEN E-STOP system OK
ORANGE Indicates that the system needs to be reset
RED E-STOP is active somewhere in the system
RED blin ing E-STOP button is pressed on the device

( 6 / 18)
Device menu functions
ENCODER w eel:
This green button turns the selected channels of Hoist Control system ON when it is active. Once
the GO button has been depressed, the energizing of the hoists is turned off. GO button is blin ing
when status of system is activated and you’re able to move hoist
DISPLAY:
TFT display which shown information about remote and also the lin ed controllers
E-STOP:
This switch protects the operation of the base unit from undesired operation and its press turns the
Controller to an inactive state. E-STOP is a red color button. Once the E-STOP button has been
pressed, system is loc ed in an inactive position and the button must be rotated cloc wise to be
released to continue operation.

( 7 / 18)
DISPLAY INDICATION
Remote ID Number of linked and active controllers
ID of controller
AR: Automatic RESET enabled
MR: Manual RESET enabled
P: Pause
G; GO
Arrow down – c annel will go down
Arrow up – c annel will go up
A:1-12 Address of controller
Device oeration
After connection to t e link t e device get discovery of connected controllers. T e controller and
remote will get paired and remote will become t e master of operation. For confirmation of t is
operation you need to press E-STOP and release E-STOP.
When device on link is unable to RESET this screen is displayed. SAFETY means that controller ins
unable to reset. Please check GR UP stop status.

( 8 / 18)
After this operation device will get reset and ready for operation. Is indicated by the green STATUS
LED and also GREEN E-STOP LED.
For access to the ADR-REM TE menu please rotate encoder to the T P ID and hold center button for
cca 3s until display of MENU is shown. During this operation G command is disabled.

( 9 / 18)
Main menu window. You can create LL /locked link of devices/, setup the display parameters and
show the AB UT the remote screen.
For creation of L CKED LINK please anter menu L CKED link. Then all controllers that been
discoverable on lnk will be added to L CKED LINK. This means that conttoller setup will work only
when all controllers are NLINE so if you loose one of controller for power down issue, other
controllers operation will be blocked as well.

( 10 / 18)
Locked link save operation: Press middle button to save the L CKED LINK
CLEAR of L CKED LINK, please enter menu and hold middle button to clear locked link. After this
operation controller will not watch each other on
link

( 11 / 18)
Locked link is shown on main screen with 4/4LL which means tat 4controllers from 4 controllers is
online and locked link has been activated:
L CKED link ERR R: This screen shown that one controller is lost from LINK. Resove by re-connecting
the device again or remove locked link.

( 12 / 18)
DISPLAY MENU: Y u can setup backlight setup and time before screen saver will occour. The setup
will protect display as tft is sensible for long time operation. Use carefully.
AB UT MENU: the about informaiton is displayed

( 13 / 18)
C NTR LLER EDIT menu: Use encoder to go to the desired controller. Hold middle button for desired
time and you will enter menu of controller.
Controller menu: IN controller menu you can setup
1. IDENTIFY = will send identify command to controller to easy visual check of what kind of
controller you’re trying to setup
2. ADDRESS = is start address of operation. If you want to controll 24 channels consisting of
2x12 way unit you need to setup the 1st controller to adress=1 and 2nd to address=2. If you
have 3x 8way you need to use adresses 1, 9, 17
3. RESET = this says if controller has AUT MATIC or MANUAL RESET. When there is automatic
reset enabled the controller will check itself and reset after cca 2 seconds. N press of RESET
button is needed. When RESET = MANU means that each e-stop need to be resolved by
pressing RESET button of controller front pannel.

( 14 / 18)
Wen you send indetify the CMD SEND command is shown:
ADDRESS SETUP screen:

( 15 / 18)
RESET SETUP screen:
DEVICE MENU:

( 16 / 18)
Remote connector
Neutri NC5-FDL
Pin Function note
1
Data CMN
Data Common
2 Data - Data Minus
3 Data+ Data Plus
4 DC1
Power supply for CMC
DC12-36V
5 DC2
Power supply for CMC
DC12-36V
Housing + Dimensions
3mm lightweight aluminum box
Warranty
ADR-DIGI-AHD series hoist controller is covered by a 2-year manufacturer’s warranty. For extended
warranty conditions, please contact the manufacturer at sales@srs-group.com.
Warranty covers the original factory installed components of the controller and their correct
functioning.
Warranty voids if any part or replacement components is installed or modified without authorization
from the manufacturer and/or the internal circuit is tampered or modified and/or the controller is
operated outside normal use conditions and if the electrical power supply is not conform or there is
connection error or mechanical damage of controller, including overload and improper use.
We, as a manufacturer, always help you to repair your unit.

( 17 / 18)

( 18 / 18)
Copyright 2017 SRS Group, s.r.o. | Specifications subject to change without notice.
Document: ADR-DIGI-AHD_manual_M327.doc | Version 3.1 | Actual as of: 7 June 2019
SRS Group s.r.o.
Rybnicna 36/D | 831 07 Bratislava | Slova ia
Phone: +421 2 44 681 417 | Fax: +421 2 4468 1419
Email: sales@srs-group.com | www.srs-group.com
This manual suits for next models
2
Table of contents
Other SRS Labs Controllers manuals
Popular Controllers manuals by other brands

Mitsubishi Electric
Mitsubishi Electric PAC-IF033B-E Operation manual

Mitsubishi
Mitsubishi MELSEC iQ-R series user manual

PS Automation
PS Automation PSL201 Short operating instructions

Panasonic
Panasonic AFP7CPS Series user manual

Trane
Trane Tracer TD7 user guide

Bosch
Bosch DSA-N2E8XG-12AT Quick installation guide

Mitsubishi Electric
Mitsubishi Electric MELSERVO-JET MR-JET-G-N1 Series user manual

Emerson
Emerson E2 manual

Adaptec
Adaptec ACB-2002A user guide

HomeMatic
HomeMatic HmIP-FAL24-C6 Installation instructions and operating manual

Conrad
Conrad 1460794 user manual

Contro l4
Contro l4 HC-300 Technical specifications