ATTENTION!
This instruction manual contains important information about the installation and the use of
the equipment. Please read and follow these instructions carefully.
Always ensure that the power to the equipment is disconnected before opening the
equipment or commencing any maintenance wor .
WPSU_en_manual_M198
Scroller po er supply
ith optional Wireless DMX
WPSU-600/480/240
DDL4

( 2 / 12)
IMPORTANT SAFETY INFORMATION
The following general safety precautions must be observed during all phases of
operation, service, and repair of this equipment. Failure to comply with these
precautions or with specific warnings in this manual violates safety standards
of design, manufacture, and intended use of this equipment.
Do not operate in an explosive atmosphere!
Do not operate this equipment in the presence of flammable gases or fumes.
Operation of any electrical instrument in such an environment constitutes
a definite safety hazard. Device should never be placed near or over heat
register or any other source of heated air and it should not be installed or
operated without proper ventilation.
Mains AC 90-265V connection
AC power is connected to the scroller via Neutri PowerCon blue connector.
Standard supply is UNISCHUKO lead with Neutri PowerCon. Always respect
mar up of L and N on connector for correct wiring of Line and Neutral.
DMX connection
DMX connectors are located on left front side of the Scroller power supply.
There are both 3-pin and 5-pin Neutri fitted in. Last WPSU in line should be
terminated by the termination resistor of 120ohm operated by switch close to
the DMX IN/OUT.
There is DATA LED indication for DMX data presence on the device. When
operating device is in Wireless DMX mode, the loss of radio signal will cause the
device switch automatically to the cable mode; the cable can be used as a
bac up of Wireless DMX line. Received Wireless DMX signal is not present on
the DMX IN/OUT connectors at all times.
Pin 1 Data Common
Pin 2 Data -
Pin 3 Data +

( 3 / 12)
F ont panel:
WPSU600:
WPSU480:
WPSU240:
On the front panel, there is a red POWER indication LED for the power supply
state. There is also a DATA LED for DATA indication. DATA LED is ON, when the
DMX signal is connected to the device or it is received by the Wireless DMX.
Wireless DMX is operated separately from the W-DMX module. Top button is the
MODE button and is used for ON/OFF operation of the wireless part.
Bottom W-DMX button is used for operation as Lin /Unlin from the Wireless DMX
transmitter.

( 4 / 12)
Rea panel:
The MAINS fuse and MAINS connector /Neutri PowerCon/ are located on the rear
side of WPSU. On both long sides of device, there are 4 holes for M6 Eyebolt and 2
holes M10 for C-CLAMP attachment.

( 5 / 12)
Device in use:
By default, Power LED indicates whether the device is on main power. If the
Power LED does not come up, please chec mains power input or fuse. Always
use fuses of the same rating as the one received from manufacturer or one of
rating written on bac side.
When the DMX cable is connected to the device, LED mar ed DATA goes ON;
this indicates that WPSU is receiving the DMX signal. DATA LED indicates the
ON state of Termination during the Power On sequence. To avoid
misunderstanding between DATA and Termination indication, do not terminate
the device without DMX data. Once the DMX signal is received, the terminal
indication will be overridden by DMX DATA.
The speed of light on these LEDs also indicates the refresh rate of DMX signal.
DATA LED fast blin ing stands for high refresh rate, while slow blin ing means
slow refresh rate.
Sc olle connection:
Use only approved scroller cable. Approved cable should have two conductors of
14 AWG wire for power and two shielded and twisted conductors of 22 AWG wire
for data.
The following pinout for the 4-pin connector must be followed:
PIN1: DC_GND
PIN2: DATA-
PIN3: DATA+
PIN4: DC+24V
Optionally, unit can be equipped with DC12V/24V/36V/48V PSU
Additional scrollers can be daisy-chained together from the OUT plug. Connect the
last scroller to the return line of WPSU for termination and power supply.
Compatible equipment watt consumption:
Rosco I-Cue 17 watts
Rosco DMX Indexing Rotator 6 watts
AC Lighting/Apollo Chroma Q Broadway 22 watts
AC Lighting/Apollo Chroma Q M1, 2, 5, 8 36 watts
Apollo Roto-Q 12 watts
City Theatrical DMX Iris 8.5 watts
DHA Gobo Carousel 18 watts
DHA Twin DMX 12 watts
Rainbow 6", 8", 12" Pro Colour Scroller 14 watts
Rainbow 15" Pro Colour Scroller 29 watts
Gam Indexable Twin Spin 14.4 watts
Gam SX-4, 6 Gobo Tray 10.8 watts

( 6 / 12)
DMX only ope ation
For the DMX operation, turn off the W-
DMX module by holding the MODE button
until both W-DMX and MODE buttons turn
RED.
Now connect the DMX cable to DMX-IN
connector and use WPSU as standard
DMX Scroller power supply.
DMX+ Wi eless DMX ope ation
For W-DMX operation, turn ON the W-DMX
module by holding the MODE button until
the MODE button are lights GREEN. The
W-DMX function button will indicate the
W-DMX functionality as is shown in figure
at the bottom of this page.
W-DMX button has only one function; to
log OFF from lin ed transmitter. To log
off, hold for more than 5s.
There is an automatic bac up of W-DMX line by the cable connection. If the W-
DMX is lin ed to transmitter and signal quality is bad, W-DMX active LED goes
OFF and the splitter will retransmit signal from IN/TRHU port. In normal state,
when W-DMX signal quality is good, the W-DMX active LED is ON.
W-DMX LED/ button signalization:

( 7 / 12)
W-DMX functions
1. W-DMX is turned OFF. WPSU is used
as a DMX splitter. To turn the W-DMX
ON, hold the MODE button for three
seconds. MODE button will light
GREEN.
2. W-DMX is ready to be lin ed, WPSU
wor s as s receiver of W-DMX signal
without lin ing to the transmitter.
Please hold the button on Transmitter
to start lin ing to W-DMX transmitter.
3. W-DMX lin ed + DMX is missing on
Transmitter the W-DMX LED is
signalizing this by blin ing in
RED/GREEN state. Bar-graph is now in
an active state.
To lin out from Transmitter, hold the
W-DMX button for 10s; after that,
module will be in state 2.
4. W-DMX is lin ed to Transmitter and
receiving DMX signal. Both indicators
are GREEN. Bar-graph is wor ing and
showing W-DMX signal strength.

( 8 / 12)
Technical data
Mains powe input:
AC 90-265V / 50-60Hz, UniSchu o/PowerCon 3x0.75mm2, 1.5m long
WPSU-240: 5A, WPSU-480: 8A, WPSU-600: 10A
DMX Input / Output:
1x USITT DMX512 /RS485/ isolated up to 1000V
Wireless DMX card made by www.lumenradio.com or www.wirelessdmx.com
Sc olle Output:
2,4,6 x USITT DMX512 /RS485 amplified
DC24V power output* /DC48V version or others are on request/
Mounting points:
In total, there are 4x M6 and 2xM10 for C-clamp and safety eye connection.
Lightweight Aluminum with black/white powde coating:
WPSU-240/480: 315x110x350mm 3.2/4 g
WPSU-600: 383x110x350mm 5.3 g
Tempe atu e of use:
-20 °C to +40 °C
Wa anty:
Two-year /24-month/ warranty
DECLARATION OF CONFORMITY
Acco ding to guidelines 89/336 EEC and 92/31 EEC:
Name of p oduce : SRS Light Design s.r.o.
Add ess of p oduce : Rybnicna 36/D, 83107 Bratislava, Slova Republic
Declares that the product
Name of p oduct: WPSU, Scroller power supply
Type: WPSU-240, WPS-480, WPSU-600, PSU-240, PSU-480, PSU-600
Corresponds to the following product specifications and R&TTE Directive of the
European Union:
Safety: EN60065, resp. EN 60950
EMC: EN55103-1, resp. EN55103-2
Radio: EN 301 489-1; 301 489-17; EN 300-328-1; EN 300-328-2

( 9 / 12)

( 10 / 12)

( 11 / 12)

( 12 / 12)
Copyright 2018 SRS Group s.r.o. | Specifications subject to change without notice.
Document: WPSU_en_manual_M198 | Version 1.0 | Actual as of: 22 October 2018
SRS G oup s. .o.
Rybnicna 36/D | 831 07 Bratislava | Slova ia
Phone: +421 2 44 681 417 | Fax: +421 2 4468 1419
Email: sales@srs-group.com | www.srs-group.com
This manual suits for next models
2
Table of contents
Popular Power Supply manuals by other brands

Videx
Videx 520MR Installation instruction

Poppstar
Poppstar 1008821 Instructions for use

TDK-Lambda
TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda
TDK-Lambda 500A instruction manual

Calira
Calira EVS 17/07-DS/IU operating instructions

Monacor
Monacor PS-12CCD instruction manual