Stairville EarthQuake DMX512 User manual

EARTHQUAKE
User Guide
Please read these instructions carefully before use

INDEX
A. GENERAL INSTRUCTIONS
B. MAIN FEATURES
C. LAMP
D. HOW TO CONTROL THE UNIT
-----(1) By universal DMX controller
-----(2) Pre rogrammed function
-----(3) By easy controller
E. FIXTURE CLEANING
2

A. GENERAL INSTRUCTIONS
Please read the enclosed instructions carefully as they include im ortant oints
about safety for the installation, usage and maintenance of the unit.
Please kee this booklet with the unit for future consultation. If you sell the unit
to another user, be sure that the new user also receives this instruction booklet thus
giving them the necessary information about the use and general warnings
regarding the unit.
Before the initial start-u , lease un ack and carefully check all com onents in
case any damage may have occurred during trans ortation.
Locate in a suitable s ot for your device where there is good ventilation. Also,
make sure that no ventilating fans or slots are blocked.
Protect our environment! Please dis ose of the acking boxes ro erly.
The electrical work that is necessary for installation must be done by qualified
ersonnel
Always remember to un lug the unit from the main ower before any service is
done. Do not o en the unit. There are no serviceable arts inside.
It is very im ortant to ground the yellow/green conductor to earth in order to
meet regulations for safety.
Check the surrounding area and make sure there are no flammable liquids,
water or metal objects that could enter the fixture. If a foreign object enters the unit,
immediately disconnect the main ower. Also, lace the fixture in a well-ventilated
room at about 15 cm from the walls.
Do not touch any wires during o eration, as high voltage is hazardous.
In the event of serious o erating roblems, sto using the unit immediately.
Never try to re air the unit yourself. Re airs carried out by unqualified ersonnel
can lead to damage or malfunction. Please contact the nearest authorized
Technical Assistance Center. Always use genuine s are arts.
3

B. MAIN FEATURES MAIN FEATURES
• Voltage:AC 120V 60Hz or 230/240/250V 50/60Hz
• Bulb: ELC 24V 250W
• The unit is a DMX512 scanner. It features full DMX512 control, 14 gobos lus
o en and 14 colors lus white, accurate focusable o tics system and ste er
motor with blackout feature. Fan cooling.
• It can be o erated by DMX512 control or can be used as an individual unit
without a control.
• It can be linked together in master/slave combination, as many as required in 4
channels and run by built-in re rogrammed chase sequences automatically or
by sound activation through an internal micro hone to create an intelligent
effect.
• Please use a 3 in XLR cable/ lug when connecting them together.
• It features different re rogrammed chase atterns.
• Dimensions:338mm x 320mm x 216 mm
• Weight:9 kg / 19.8 lbs
C. LAMP
ELC 24 250W
• Always switch off the mains su ly and never handle the lam or luminaire when
it is hot.
• Do not touch the bulb with bare hands. If this does ha en, clean the lam with
denatured alcohol and wi e with a lint free cloth before installing.
4

D. HOW TO CONTROL THE UNIT
( 1 ) By universal DMX controller
The DMX512 is widely used in intelligent lighting control, with a maximum of 512
channels.
A DMX512 system requires a controller, lighting equi ment and cable. These are
connected together in a “daisy chain” with the terminator at the end. The cable
cannot be branched or s lit to a “Y” cable.
The terminator requires a 90-120 Ohm 1/4 Watt resistor soldered between two
signal cables.
The DMX512 uses a very high-s eed signal. Inadequate or damaged cables,
bad solder joints or corroded connectors can easily distort the signal and shut
down the system. A reliable DMX512 system starts with good quality cables.
Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511. The end of the DMX512
system should be terminated reducing signal errors.
3 in XLR connectors are more o ular than 5 in XLR.
3 in XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 in XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5

( 2 ) Preprogram functions
The unit can be linked together as master/slave in daisy chain in linkage as many
units as required and run by built in re rogrammed chase sequences triggered
by music.
Not need to set the dipswitches in master/slave mode.
* 2-light show
Di switch 10 “off” means the unit works normally and “on” means inversion. In
order to creating a great light show, you can set di switch 10 “on” on any unit that
is linking to the master unit to get contrast movement to each other, even if you
have two units only. Di switch 10 on the first unit is no use in the DMX linking, as it
is the master unit that o erates the light show.
( 3 ) By easy controller
The easy remote control is used only in master/slave mode. By connecting to the 1/4”
micro hone jack of the first unit, you will find that the remote control on the first unit will
control all the other units for Stand by, Strobe/Next and Fast/Slow function.
1. STAND BY - To blackout all the units.
2. FUNCTION - STROBE/NEXT
- Under FAST ( LED off )mode, the units will strobe in three
different ways:
a) Strobe in different gobos and colors.
b) Synchronous strobe in white color.
c) Two-light strobe in white color.
- Under SLOW ( LED on ) mode, ress FUNCTION button to
choose desired color and gobo. It will change ten colors and then
change one gobo.
3. MODE - FAST/SLOW
When the LED is off, it is in FAST mode. The unit’s movement- Pan/Tilt & Gobo/Color is
sound activated. If the LED on, it is in SLOW mode, Pan/Tilt is sound activated but
Gobo/Color wheel are static, controlled by Next button.
6

DMX512 CONFIGURATION
Channel 1 Channel 2 Channel 3 Channel 4
Shutter Gobos/Colors Rotation Zoom
255 Fastest s eed
Gobo Shaking
136 Slowest s eed
135 Fastest s eed
Strobe
016 Slowest s eed
000-015 Sto
255 Fastest s eed
Rainbow Effect
128 Slowest s eed
120-127 Gobo 14 / Yellow
112-119 Gobo 13 / Red
104-111 Gobo 12 / Four-color
096-103 Gobo 11 / Green
088-095 Gobo 10 / Magenta
080-087 Gobo 9 / Red
072-079 Gobo 8 / Cyan
064-071 Gobo 7 / Red
056-063 Gobo 6 / Green + Pink
048-055 Gobo 5 / Magenta
040-047 Gobo 4 / Amber
032-039 Gobo 3 / Blue
024-031 Gobo 2 / Orange
016-023 Gobo 1 / Blue
008-015 O en
000-007 Blackout
246-255 Sto
245
135
121-134 Sto
120
010
000-009 Sto
255 Fastest s eed
Zoom in/out
(continue)
160 Slowest s eed
159 Zoom out max.
000 Zoom in min.
• Start the address
How to address your DMX512 system:
1. Select the channels of DMX controller
2. Di switches
Di #1 #2 #3 #4 #5 #6 #7 #8 #9
Value 1 2 4 8 16 32 64 128 256
• Exam les:
Channel 01:di / on : #1(=1)
Channel 05:di / on : #1, #3(1+4=5)
Channel 09:di / on : #1, #4(1+8=9)
Channel 13:di / on : #1, #3, #4(1+4+8=13)
7

E. FIXTURE CLEANING FIXTURE CLEANING
The cleaning of internal and external o tical lenses and/or mirrors must be carried
out eriodically to o timize light out ut. Cleaning frequency de ends on the
environment in which the fixture o erates: dam , smoky or articularly dirty
surroundings can cause greater accumulation of dirt on the unit’s o tics.
•Clean with a soft cloth using normal glass cleaning roducts.
•Always dry the arts carefully.
•Clean the external o tics at least once every 20 days. Clean the internal
o tics at least every 30/60 days.
8
EC Declaration of Conformity
We declare that our roducts (lighting equi ments) com ly with the following
s ecification and bears CE mark in accordance with the rovision of the
Electromagnetic Com atibility (EMC) Directive 89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
Harmonized Standard
EN60598-1: 2000+ALL:2000+A12:2002
Safety of household and similar electrical a liances
Part 1 : General requirements

Technical Specifications
Power AC 120V 60Hz AC 230-250V 50/60Hz
Fuse 20mm Glass T6.3A Fast Blow 20mm Glass T5A Fast Blow
Lam s ELC 24V 250W
Dimension 338mm x 320mm x 216 mm
Weight 9 kg / 19.8 lbs
9

10
Table of contents
Other Stairville Scanner manuals
Popular Scanner manuals by other brands

Socket
Socket Cordless Ring Scanner Series 9 quick start guide

Datalogic
Datalogic Matrix 120 Product reference guide

LMI Technologies
LMI Technologies HDI 100 Series quick start guide

SICK
SICK TIM310-1030000S01 technical information

Visioneer
Visioneer STROBE 500 - FOR WINDOWS user guide

Metrologic
Metrologic MS6720 Setting up