limiTeD warraNTy
SOLUTIONCAUSEINDICATORPROBLEM
Increase the range. Range is too short.. LED in the
sensor does not
flash once when
user’s hands
are within the
sensor’s range.
No water
is coming
out of the
faucet: Decrease the range. Range is too long.
. Unit is in “Security Mode”*
Eliminate the cause of
reflection.
. Sensor is picking up reflections from the
washbasin or another object.
Unscrew solenoid, pull out
the plunger and the spring
from the solenoid and clean
them. Use scale remover
material if needed. When
replacing the plunger, please
make sure that the spring is
in vertical position.
. Debris or scale in solenoid.. LED in the
sensor flashes
once when
user’s hands
are within the
sensor’s range.
Clean the orice or replace
the diaphragm.
. The central orice in the diaphragm is
plugged or the diaphragm is torn
Reduce the supply water
pressure.
. The water supply pressure is higher than
8 bar.
Shut o the water supply
and unscrew one of the
flexible pipes in order to
reduce the pressure that
blocks the product.
. The water supply pressure is under 8 bars
and yet the pressure in the faucet’s body is
higher. This situation could be caused by a
sudden increase in the water supply pressure
that the backcheck prevents from dropping,
even aer water supply pressure drops under
8 bars.
Clean the orice or replace
the diaphragm.
. Debris or scale in diaphragm. Sensor flashes
once when
user’s hands
are within the
sensor’s range.
Water flow
from spout
does not
stop: Connect the connectors
properly. Refer to page 11.
. Connectors between the electronic unit and
the Dual power input box are disconnected or
not connected properly
Clean or eliminate the cause
of interference.
. Sensor is dirty or covered.. LED in the
sensor does not
flash once when
user’s hands
are within the
sensor’s range.
Decrease the range or
eliminate the cause of
reflection.
. Sensor is picking up reflections from the
washbasin or another object.
Remove, clean, re-install the
lter or aerator
Filter or aerator is cloggedWater flow
diminished
TrouBleshooTiNg
* “Security Mode”: If the sensor is covered for more than 90 sec. the faucet will automatically shut o water
flow. To return to normal operation remove any blockage to re-establish operation.
Y. Stern Engineering Ltd. warrants that its electronic products will be free of defects in
material and workmanship during normal use for two years from the date the product is
purchased.
If a defect is found in normal use, Y. Stern Engineering Ltd. will, at its discretion, repair,
provide a replacement part or product, or make appropriate adjustments. Damage
caused by accident, misuse, or abuse is not covered by this warranty. Improper care
and cleaning will void the warranty. Proof of purchase (original sales receipt) must be
provided to Stern Engineering Ltd. with all warranty claims.
Stern Engineering Ltd is not responsible for labor charges, installation, or other
incidental or consequential costs other than those noted above. In no event shall the
liability of Stern Engineering Ltd. exceed the purchase price of the product.
If you believe that you have a warranty claim, contact your Stern Distributor, Dealer or
Plumbing Contractor. Please be sure to provide all pertinent information regarding your
claim, including a complete description of the problem, the product, model number,
the date the product was purchased, from whom the product was purchased and the
installation date. Also include your original invoice.
Y. STERN ENGINEERING AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES. This warranty excludes product damage
due to installation error, incorrect maintenance, wear and tear, battery, product
abuse, or product misuse, whether performed by a contractor, service company, or the
consumer. This warranty does not cover product damage caused by the following:
- Incorrect installation.
- inversions of supply pipes.
- Pressures or temperatures exceeding recommended limits.
- Improper manipulation, tampering, bad or lapsed maintenance.
- Foreign bodies, dirt or scale introduced by the water supply or soap tank.
- Use of the soap outside of viscosity specications.
- Alteration of the original soap/foam dispenser components (including pipes).