7
MODEL: SRHGC90 | PRODUCT CODE: 60140 | 04/2018
Controls
Your Canopy Rangehood features push button controls (Fig. 1) with three speed levels of extraction.
– Push the ‘Low’ button, an audible buzzer will sound once, and the rangehood will operate at low speed.
– Push the ‘Mid’ button, an audible buzzer will sound once, and the rangehood will operate at a medium
speed.
– Push the ‘High’ button, an audible buzzer will sound once, and the rangehood will operate at a high speed.
– Push the ‘Light’ button and the two lights will come on. To turn the lights off, simply push the ‘Light’ button
again.
– To switch the rangehood motor or light off, simply press the button a second time.
It’s important to carefully read the following installation instructions before beginning the installation of your
rangehood.
Installation Requirements
Typical installation tools required
You’ll most likely require the following tools/equipment (not supplied)
for the installation of your rangehood.
– Electrical drill – Tape Measure
– Screw-driver – Spirit Level
If ducting your rangehood, you’ll also most likely require:
– Jig saw – Ladder
– Duct-tape – Ducting
Important installation safety notes:
– Always switch the power off prior to beginning the installation.
– Stainless steel is very easily damaged during installation. Wherever
possible, protect the rangehood with the cardboard box or plastic wrap
during the installation.
– For safety reasons, this Rangehood must be earthed.
– A power point must be located within 1.5m of the power cord exit from
the rangehood, and it should be always accessible to allow isolation
from power during cleaning or maintenance.
– A 150mm round ducting adapter is supplied, however all other ducting
accessories are not.
– All ducting must comply with building codes and local requirements.
– If you are re-circulating the air, rather than ducting, please ensure that
the side outlet grilles are not obstructed in any way as this will affect
the efciency of the rangehood.
– Ensure that the rangehood is mounted in a level position, both
horizontally and vertically. This is essential to ensure the rangehood
operates correctly and prevents grease build up at one end.
pic6C
Low
Mid
High
Ligh t
Stop
pic6C
Low
Mid
High
Ligh t
Stop
pic6C
Low
Mid
High
Ligh t
Stop
WARNING!
All electrical work
associated with the
installation of this
rangehood must be carried
out by a licensed electrician.
This rangehood must be
correctly installed by a
suitably qualied person
in strict accordance with
all applicable rules and
regulations and following
the instructions in this
manual.
Do not try to install the
rangehood yourself; doing
so will expose you to danger
and void the warranty.
Improper installation,
adjustment, alteration or
service can cause injury
or damage. We decline
any responsibility for injury
or damage, to persons
or property, as a result of
improper installation.
Fig. 1