Stoane Lighting Mole X User manual

Mole X
Installation and Maintenance
Instructions
IMPORTANT: All wiring connections must be made before switching on mains power.
European Conformity
Please retain these instructions for future reference
This product should not be disposed of in your general waste
Suitable for Exterior Use
IP66 Dust tight and protected against powerful jets of water.
Class III - Extra Low Voltage
Xicato LED Module
1
410 381 1497 inter-lux.com [email protected]
Inter-lux reserves the right to make technical changes without notice.
STOANE LIGHTING
Electrical Supply
Installation must be carried out by a qualified electrician in
accordance with BS 7671:2008 Wiring Regulations.
230/240V AC 50/60Hz mains supply to a suitable SELV
LED Driver.
Site conditions: LED equipment is more susceptible to
static damage and overvoltage than previous technology.
Before handling or connecting to the mains supply ensure
that all MSL products are protected from static discharge
and that the mains supply is to regulation. (230V +10
-6%)
This fitting is supplied with a Xicato LED module. Refer
to the fitting label for the module version and wattage.
More information on the module can be found at
www.xicato.com/support
Mains cables must be double insulated, strain relieved
and separated from E.L.V output cables.
This unit requires a constant current driver. 700mA Max.
Observe polarity:
Positive (+) is marked as RED.
Incorrect supply or reverse polarity can cause irreparable
damage.
All connections must be made before switching on mains.
If the supply is energised prior to making the connections
to the fitting then the resulting surge will damage the LED.
All lighting equipment is delicate and easily damaged
through misuse or inappropriate installation (mechanical
or electrical). Repairs and replacements may cause
delays and will be chargeable. Contact MSL for support if
required. For full warranty terms & conditions please visit
our website.
Dimming control circuit source must be of SELV insulation
class.
Ensure supply driver and connectors are housed indoors
OR in a suitably IP rated enclosure.
Installation
Check that the mounting surface is suitable for the
installation of this fitting.
An 86mm diameter hole is required for mounting.
Step 1 Make mains connections to SELV LED driver
and extra low voltage connections to the
fitting.
Step 2 Insert the fitting into the cutout and secure in
place with silicone or similar.
After opening the sealed portion of the luminaire for
any reason, MSL recommends running the fitting for
15 minutes with the lid open to expel moisture before
closing it up. This will prevent condensation on the
lens and protect the fitting from corrosion.
WARNING: Do not look at exposed LED lamps in
operation. Eye injury can result.
Cleaning:
Fully isolate the fitting and allow to cool.
Clean the fitting with a damp lint free cloth and a mild
solution of soap and water. The fitting must be
completely dry before reconnecting power.
Incompatible or abrasive chemicals can damage the
fitting, contact MSL for advice if required.
2
410 381 1497 inter-lux.com [email protected]
Inter-lux reserves the right to make technical changes without notice.
STOANE LIGHTING
86mm dia hole
12
To driver
Silicone
Install in well drained ground.
Surface gradient must run away from the fitting.
Connector
3
410 381 1497 inter-lux.com [email protected]
Inter-lux reserves the right to make technical changes without notice.
STOANE LIGHTING

Other Stoane Lighting Light Fixture manuals

Stoane Lighting Mole User manual

Stoane Lighting

Stoane Lighting Mole User manual

Stoane Lighting Iris Type S User manual

Stoane Lighting

Stoane Lighting Iris Type S User manual

Stoane Lighting Module M User manual

Stoane Lighting

Stoane Lighting Module M User manual

Popular Light Fixture manuals by other brands

Larson Electronics HALP-48-2L-LED-DNMS instruction manual

Larson Electronics

Larson Electronics HALP-48-2L-LED-DNMS instruction manual

Lumascape LS5030 installation instructions

Lumascape

Lumascape LS5030 installation instructions

Westfalia 90 05 36 Original instructions

Westfalia

Westfalia 90 05 36 Original instructions

Chauvet Professional ROGUEOUTCAST2BEAM Quick reference guide

Chauvet Professional

Chauvet Professional ROGUEOUTCAST2BEAM Quick reference guide

Philips CDB2SPF228 specification

Philips

Philips CDB2SPF228 specification

SDJ SG LEDKITHP3 user manual

SDJ

SDJ SG LEDKITHP3 user manual

Flash butrym FL-300 user manual

Flash butrym

Flash butrym FL-300 user manual

Philips Lytespan 22MW4 specification

Philips

Philips Lytespan 22MW4 specification

Seiwa LZLA Series instruction manual

Seiwa

Seiwa LZLA Series instruction manual

PR Lighting LS 150 Water user manual

PR Lighting

PR Lighting LS 150 Water user manual

Wibre 4.0197 Series installation manual

Wibre

Wibre 4.0197 Series installation manual

Philips Lytespan 24MHT4RNF specification

Philips

Philips Lytespan 24MHT4RNF specification

Beamz MHL-1410Wispot14x 10W Quad DMX 2.4Ghz manual

Beamz

Beamz MHL-1410Wispot14x 10W Quad DMX 2.4Ghz manual

Lightolier Calculite C4MRD CCDW specification

Lightolier

Lightolier Calculite C4MRD CCDW specification

Lightolier Luminosities 40886 specification

Lightolier

Lightolier Luminosities 40886 specification

EuroLite LED TL-3 TCL 3x3W Trusslight user manual

EuroLite

EuroLite LED TL-3 TCL 3x3W Trusslight user manual

Cooper Lighting MPWA Specifications

Cooper Lighting

Cooper Lighting MPWA Specifications

Philips HF3470/01 user manual

Philips

Philips HF3470/01 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.