Stulz UltraWater Series User manual

STULZ the natural choice
STULZ UltraWater®
3 Stufen-Umkehrosmosesystem
Version 05-2012
Technical Manual Humidi cation
Technical Manual
Humidi cation
STULZ UltraWater
3-stage reverse osmosis systems
Version 01-2015
1000645 / EN
Translation of the original User Guide
– Read carefully before use-
– Keep in a safe place for future reference-

Dear Customer,
Many thanks for choosing to buy a STULZ product. STULZ has been a purveyor of
sophisticated technical solutions for comfort and precision air conditioning applications
since 1947.
Hotline
If you have any questions or problems regarding our products, please get in touch via
our hotline on +49 40 5585 252 or at [email protected].
Technical Support
For technical problems, please contact our Technical Support on
+49 40 298 10 4444.
Current updates to technical documentation
You can nd the latest documents and brochures at:
www.stulz.de/e-stulz
Manufacturer's address
STULZ GmbH
Air Conditioning and Humidifying Systems Division
Holsteiner Chaussee 283
D-22457 Hamburg
Germany

STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
3
-
Contents
1. INFORMATION ON THIS GUIDE ......................................................5
1.1. Using the guide ...............................................................5
1.2. Abbreviations ................................................................5
1.3. Nomenclature ................................................................6
1.4. Liability claims for defects .......................................................6
1.5. Exclusion of liability ............................................................6
1.6. Copyright notice ..............................................................6
1.7. Product names and trademarks ..................................................6
1.8. Technical Support .............................................................6
1.9. Hotline ......................................................................6
2. SAFETY INSTRUCTIONS ...........................................................7
2.1. Preliminary comments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.2. Proper use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.3. Unauthorized operating practices .................................................7
2.4. Personnel qualication .........................................................8
2.5. Danger if safety instructions are not complied with ....................................8
2.6. Safe working .................................................................8
2.7. Safety instructions for the plant owner / operator ......................................8
2.8. Safety instructions for maintenance, inspection and installation work .....................9
2.9. Unauthorized modication and spare parts production .................................9
2.10. Preventive measures against water damage ........................................9
2.11. Spare parts ..................................................................9
3. TRANSPORT / STORAGE ..........................................................12
4. MECHANICAL REQUIREMENTS .....................................................12
5. APPLICATION LIMITS .............................................................12
6. ABOUT THIS DEVICE .............................................................13
6.1. The principle of the reverse osmosis system .......................................14
6.2. Product package .............................................................15
6.3. Rating plate .................................................................16
6.4. Technical data ...............................................................17
6.5. Application limits .............................................................17
6.6. Filter service life .............................................................18
6.7. Factory settings ..............................................................18
6.8. Device construction ...........................................................19
6.8.1. UltraWater 120 .......................................................19
6.8.2. UltraWater 400 .......................................................20
7. INSTALLATION ...................................................................21
7.1. Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
7.2. Connection diagram ..........................................................22
7.2.1. Connecting the reverse osmosis water (D) .................................24
7.2.2. Connecting the waste water (B) ..........................................25
7.2.3. Connecting to the pressure tank (C) ......................................26
7.2.4. Connecting the water supply (A) .........................................27
7.3. Installing the membrane .......................................................28
7.4. Tightening the lter housing ....................................................29
7.5. Electrical connection ..........................................................30
7.6. Wall-mounted installation ......................................................31

STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
4
-
8. START-UP .......................................................................32
9. OPERATION .....................................................................34
10. SHUTTING DOWN THE SYSTEM ....................................................35
11. DISPOSAL ......................................................................35
12. MAINTENANCE ..................................................................36
12.1. Replacing the lters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
12.2. Replacing the membranes .....................................................38
12.3. Replacing the ow restrictor ....................................................39
12.4. Inspecting the pressure tank ....................................................39
12.5. Checking the pure water quality and throughput ....................................40
13. TROUBLESHOOTING .............................................................41
14. SPARE PARTS LISTS ..............................................................43
14.1. Spare parts list for SUW 120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
14.2. Assembly drawing of SUW 120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
14.3. Spare parts list for SUW 400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
14.4. Assembly drawing of SUW 400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
15. CE-CERTIFICATION ...............................................................47
16. MAINTENANCE PLAN .............................................................49

STULZ UltraWater 3-stage reverse osmosis system SUW Information on this guide
© STULZ GmbH, Hamburg
-
5
-
1. INFORMATION ON THIS GUIDE
This guide is part of the product package. It must be made accessible to all persons performing assembly,
installation, start-up and maintenance work on the product.
1.1. Using the guide
This guide contains basic instructions to be followed during erection, operation and maintenance. The guide
is intended for all persons performing assembly, installation, start-up and maintenance work on the product.
It must always be kept in the same place as the product.
Make sure that people responsible for operating the product and all persons working on the product have
fully read and understood this guide. Please contact the Service hotline if you have any queries.
As well as the general safety instructions contained in this section, please also pay attention to the special
safety notes in the other sections. Furthermore, all local statutory safety measures must be observed.
1.2. Abbreviations
Table 1: Abbreviations
Abbreviation Name Explanation
A Ampere SI unit: electrical current
DC Direct current ─
GND Ground Ground wire or signal ground
min Minute SI unit
NNeutral wire ─
NC Normally closed Relay contact
NO Normally open Relay contact
sSecond SI base unit
VVolt SI unit: electrical voltage
°C Celsius Unit of temperature
μS/cm Micro-Siemens per centimeter Unit for the conductivity of water
°dH German degrees of hardness Unit of water hardness
SDI Silt Density Index ─
TrinkwV Trinkwasserverordnung German Drinking Water Regulations
PE Polyethylene Type of plastic
WxHxD Width x height x depth Unit of measurement
DixH Diameter x height Unit of measurement
l/h Liters per hour Flow rate
l/d Liters per day Flow rate
TFC Thin lm composite Type of membrane
Item Item number Item in a drawing
STU Start-up ─

Information on this guide STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
6
-
1.3. Nomenclature
Table 2: Nomenclature
Full name Name in this document
STULZ UltraWater SUW
STULZ UltraWater 120 basic SUW 120
STULZ UltraWater 400 basic SUW 400
1.4. Liability claims for defects
Following the instructions in the Technical Manual is a prerequisite for trouble-free operation of the STULZ
UltraWater and for eventual claims for defects.
Read the Technical Manual before working with the product.
1.5. Exclusion of liability
Compliance with the installation and user guide is a prerequisite for safe operation of the product, and for
the achievement of the stated product characteristics and performance features. STULZ shall not be liable
for any damage to persons or property or any nancial loss resulting from non-compliance with the Technical
Manual. In such cases, all liability for material defects is excluded.
1.6. Copyright notice
© 2014. STULZ GmbH. All rights reserved.
All reproduction, editing, distribution and other form of use of this Manual, in whole or is part, is prohibited.
1.7. Product names and trademarks
STULZ UltraWater is a registered trademark of STULZ GmbH. The product names contained in this Technical
Manual are brand names or registered trademarks of the products bearing these names.
1.8. Technical Support
Phone Technical Support on:
Tel.: +49 40 298 10 44 44
1.9. Hotline
Phone the hotline on:
Tel.: +49 40 5585 252
e-mail: [email protected]

STULZ UltraWater 3-stage reverse osmosis system SUW Safety instructions
© STULZ GmbH, Hamburg
-
7
-
2. SAFETY INSTRUCTIONS
Please note the following basic safety instructions. The safety instructions are intended to prevent personal
injury and damage to property. The system operator must ensure that the basic safety instructions are noted
and adhered to. Make sure that the system operator and all persons who work on the system on their own
responsibility have fully read and understood the documentation. If anything is unclear or you require ad-
ditional information, please ring STULZ Technical Support.
• Non-compliance with the safety instructions can result in danger to personnel, to the environment and to
the system. Failure to comply with the safety instructions will result in the loss of any claims for damages.
• Pay attention to the safety instructions set out in this technical documentation, the applicable national
health and safety regulations and company work, operating and safety instructions.
• Safe operation of the system is only ensured if it is used in accordance with its intended use. The limit
values set out in the technical data must never be exceeded.
2.1. Preliminary comments
The basic safety instructions below apply to the STULZ UltraWater. Pay attention to the additional warning
notes in the individual sections of this technical document.
2.2. Proper use
STULZ reverse osmosis systems are approved solely for the preparation of particle-free water. Depending
on the type of system, the untreated water may have a low salt content (tap water and surface water has
up to approx. 1000 mg/l). If STULZ systems are used for water of a different quality, it is essential that you
rst contact STULZ. Generally, drinking water that conforms to the German Drinking Water Regulations is
suitable for use in reverse osmosis systems. In some cases (e.g. if the Silt Density Index is higher than 3),
suitable pretreatment (softening, hardness stabilization) must be performed beforehand.
The STULZ UltraWater is intended solely for indoor use, and may only be used with compatible products.
Any other use besides or beyond this shall be regarded as improper use. STULZ cannot be held liable for
damages resulting from the above. The plant operator is the sole bearer of the risk.
The STULZ UltraWater may only be used in accordance with the instructions in the technical documentation
from STULZ.
2.3. Unauthorized operating practices
Safe operation of the supplied system is only ensured if it is used correctly in accordance with the “Proper
use” section of the Technical Manual. The limit values set out in the technical data and test record must never
be exceeded under any circumstances.
The STULZ UltraWater is designed for technical use, not for the treatment of drinking water!

Safety instructions STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
8
-
2.4. Personnel qualication
All electrotechnical work must be performed exclusively by authorized and trained specialist personnel.
Specialist personnel within the context of this documentation are persons who are familiar with the electrical
installation, start-up, maintenance and repair of the system, and are in possession of the following qualica-
tions:
• Successful, certied completion of training in electrical engineering
• Familiarity with the technical documentation.
All work in relation to operation and use must be performed exclusively by authorized and trained specialist
personnel. Specialist personnel within the context of this documentation are persons who are familiar with
the operation and use of the system, and are in possession of the following qualications:
• Successful, certied completion of training in electrical engineering
• Familiarity with the technical documentation.
All work in relation to transport and storage must be performed exclusively by persons who have received
appropriate instruction.
The plant operator must ensure that all maintenance, inspection and installation work is carried out by
authorized and qualied specialist personnel who have been briefed by thoroughly studying the technical
documentation.
2.5. Danger if safety instructions are not complied with
Non-compliance with these safety instructions can result in danger to persons, to the environment and to
the system. Failure to comply with the safety instructions may result in the loss of any claims for damages.
Non-compliance may involve the following risks, for example:
- Failure of important system functions
- Failure of prescribed maintenance and repair methods
- Risk to persons due to electrical, chemical and mechanical phenomena.
2.6. Safe working
The safety instructions set out in this Technical Manual, the applicable national health and safety regulations
and any company work, operating and safety instructions must be observed.
2.7. Safety instructions for the plant owner / operator
If protection against accidental contact with moving parts is installed, it must not be removed while the sys-
tem is in operation. Dangers arising from electrical energy must be excluded (details on this can be found in
the specications of the VDE, for example, or obtained from local energy supply companies).

STULZ UltraWater 3-stage reverse osmosis system SUW Safety instructions
© STULZ GmbH, Hamburg
-
9
-
2.8. Safety instructions for maintenance, inspection and installation work
The plant operator must ensure that all maintenance, inspection and installation work is carried out by
authorized and qualied specialist personnel who have been briefed by thoroughly studying the installation
and user guide.
The system must be stationary and switched off before any work is carried out. It is essential that the
procedure for shutting down the system, described in the installation and user guide, is complied with. All
safety and protective equipment must be reinstalled or re-enabled immediately upon completion of the
work.
Please note the points in the "Start-up" section before starting up the system.
2.9. Unauthorized modication and spare parts production
The system may only be converted or modied following consultation with the manufacturer. Genuine
spare parts and accessories authorized by the manufacturer are a guarantee of safety. Use of different
parts may void any liability for claims arising from possible consequences.
2.10. Preventive measures against water damage
All water-based technical systems can cause water damage if they suffer a fault. Before installation, exam-
ine to what extent other plants or buildings must be protected against water damage. A central oor drain
or leakage warning system can prevent more serious damage.
2.11. Spare parts
• We recommend the use of genuine spare parts. Genuine spare parts and spare parts/accessories ap-
proved by STULZ GmbH are a guarantee of safety.
• The spare parts list can be found in the following section: Spare parts. To order spare parts, call the
hotline or your specialist retailer.

Safety instructions STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
10
-
Please read this user guide carefully and observe the instructions before installing and operating
your track humidifying system.
General
This user guide contains basic instructions to be followed during installation, operation and maintenance.
It must therefore be read by installation staff and the responsible specialist personnel/plant operator before
installation and initial start-up. It must always be kept in the same place as the system. As well as the gene-
ral instructions contained in this “Safety instructions” section, please also pay attention to the special safety
instructions included in the other sections.
Personnel qualication and training
The personnel in charge of operation, maintenance, inspection and installation must be properly qualied
for this work.
Risks of non-compliance with the safety instructions
Non-compliance with these safety instructions can result in danger to personnel, to the environment and to
the system. Failure to comply with the safety instructions may result in the loss of any claims for damages.
Safe working
The safety instructions set out in this user guide, the applicable national health and safety regulations and
company work, operating and safety instructions must be observed.
Safety instructions for maintenance, inspection and installation work
The plant operator must ensure that all maintenance, inspection and installation work is carried out by autho-
rised and qualied specialist personnel who have been thoroughly briefed by studying the user guide.
The system must be stationary and switched off before any work is carried out. It is essential that the proce-
dure for shutting down the system, described in the user guide, is complied with.
The system must be disconnected from the power for any maintenance work and a warning sign afxed to
prevent it from being inadvertently restarted. The system must be checked to ensure it is no longer carrying
voltage.
Unauthorised modication and production of spare parts
The system may only be converted or modied following consultation with STULZ. Original spare parts and
parts/accessories approved by STULZ are a guarantee of safety. Use of different parts may void any liability
for claims arising from any possible consequences.
Unauthorised operating practices
Safe operation of the system is only ensured if it is used in accordance with regulations and instructions. The
limit values set out in the technical data must never be exceeded.
This symbol indicates special measures or dangers that must be noted.
Customer service
Customer service ensures optimum operating reliability through preventive service and maintenance work
throughout the life of your system.
You can nd out about your nearest customer service agent from the manufacturer of your system at any
time.

STULZ UltraWater 3-stage reverse osmosis system SUW Safety instructions
© STULZ GmbH, Hamburg
-
11
-
We recommend you to read this “SAFETY PRECAUTIONS” carefully before the installation
work in order to gain full advantage of the functions of the unit and to avoid malfunction
due to mishandling.
The precautions described below are divided into and . The matters with possibilities
leading to serious consequences such as death or serious personal injury due to errone-
ous handling are listed in the and the matters with possibilities leading to personal injury
or damage of the unit due to erroneous handling including probability leading to serious
consequences in some cases are listed in . These are very important precautions for safe-
ty. Be sure to observe all of them without fail.
Be sure to conrm no anomaly on the equipment by commissioning after completed in-
stallation and explain the operating methods as well as the maintenance methods of this
equipment to the user according to the owner’s manual.
Keep the installation manual together with owner’s manual at a place where any user can
read at any time. Moreover if necessary, ask to hand them to a new user.
WARNING:
Installation must be carried out by the qualied installer.
If you install the system by yourself, it may cause serious trouble such as water leaks, electric shocks, re
and personal injury, as a result of a system malfunction.
Install the system in full accordance with the instruction manual.
Incorrect installation may cause bursts, personal injury, water leaks, electric shocks and re.
Install the unit in a location with good support.
Unsuitable installation locations can cause the unit to fall and cause material damage and personal injury.
The electrical installation must be carried out by the qualied electrician in accordance with “the
norm for electrical work” and “national wiring regulation”, and the system must be connected to
the dedicated circuit.
Power supply with insufcient capacity and incorrect function done by improper work can cause electric
shocks and re.
Be sure to use the cables conformed to safety standard and cable ampacity for power distribution
work.
Unconformable cables can cause electric leak, anomalous heat production or re.
Do not perform any repairs or modications by yourself. Consult the dealer if the unit requires
repair.
If you repair or modify the unit, it can cause water leaks, electric shocks or re.
Be sure to switch off the power supply in the event of installation, inspection or servicing.
If the power supply is not shut off, there is a risk of electric shocks, unit failure or personal injury due to the
unexpected start of fan.
Be sure to shut off the power before starting electrical work.
Failure to shut off the power can cause electric shocks, unit failure or incorrect function of equipment.
CAUTION:
Carry out the electrical work for ground lead with care.
Do not connect the ground lead to the gas line, water line, lightning conductor or telephone line’s
ground lead. Incorrect grounding can cause unit faults such as electric shocks due to short-circuiting.
Use the circuit breaker with sufcient breaking capacity.
If the breaker does not have sufcient breaking capacity, it can cause the unit malfunction and re.
Secure a space for installation, inspection and maintenance specied in the manual.
Insufcient space can result in accident such as personal injury due to falling from the installation place.

Transport / storage STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
12
-
3. TRANSPORT / STORAGE
- Before transport, fully drain the system and seal with plugs to prevent water from escaping.
- Pack the system in a sufciently large and cushioned cardboard box
(preferably the original box) for transport, to prevent damage.
- It is essential to avoid the formation of ice inside the system.
- The system may only be stored in a temperature range of +4...+45°C.
- Membranes must be packed in a watertight bag.
4. MECHANICAL REQUIREMENTS
Secure both the system installation board and the pressure tank so they cannot fall over. The installation
board can be fastened to sturdy walls (concrete, masonry, wood) using the supplied screws and dowels.
For other materials, use suitable fastening equipment. The pressure tank can be positioned upright. Pre-
vent hoses from falling or being caught by choosing suitable fastening equipment.
5. APPLICATION LIMITS
Reverse osmosis membranes are sensitive to frost. Therefore, never allow the temperature to drop below
freezing. The system, lled pressure tank and spare membranes may only be stored in a temperature
range of +4...+45°C.

STULZ UltraWater 3-stage reverse osmosis system SUW About this device
© STULZ GmbH, Hamburg
-
13
-
Two models with different permeation rates are available:
● STULZ UltraWater SUW 120 basic (item no. 1200256)
● STULZ UltraWater SUW 400 basic (item no. 1200257)
Technical features:
● Pressure tank with a total volume of 11 liters
● Completely preassembled for easy, low-cost installation
● Includes all lters
● All connectors and threaded couplings needed for connection to the drinking water mains
● 5-meter connecting hoses, some color-coded, for drinking water, waste water, permeate water and
pressure tank line
● Pressure pump for improved membrane efciency
● Prelter for maximum membrane service life
● Intake pressure switch
● Tank pressure switch
6. ABOUT THIS DEVICE
The STULZ UltraWater is intended for the treatment of drinking water for use in ultrasonic humidiers.
Adiabatic humidifying systems produce cold mist and must be supplied with demineralized drinking water,
in order to ensure that the vibrating elements continue to function throughout the life of the system, and
to prevent any buildup of limescale in the system or in the humidied room. This can be achieved very
simply in practice by positioning the STULZ UltraWater reverse osmosis system upstream. The heart of
the STULZ UltraWater reverse osmosis system is a high-performance membrane, which removes chalk,
sediment and other undesirable substances from drinking water. Special features of this system are an
integrated pressure pump and two combination lter stages, which ensure low-cost operation and a long
service life.
During the production of demineralized drinking water, the STULZ UltraWater reverse osmosis system
removes
● 95% of all dissolved solids (minerals)
● 99% of all bacteria and viruses, and a high proportion of organic substances
● 99% of chloride
from the water.
The STULZ UltraWater is designed to demineralize drinking water, not produce drinking
water!
Depending on the untreated water, this water treatment system removes at least 95% of all salt
and minerals from the water. If this system is used in applications with little or no outside air supply
(e.g. equipment rooms) in combination with STULZ UltraSonic humidifying systems, it is essential
to prevent salt/minerals from being brought into the room via the air humidifying system and depos-
iting themselves on surfaces. For this purpose we urgently recommend the downstream use of a
deionization system (e.g. STULZ ion exchanger SD2800 – K85802).
Note:

Transport / storage STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
14
-
If two solutions with different ion concentrations – aqueous solutions with different salt content – are sepa-
rated by a semi-permeable membrane, the solutions attempt to equalise the concentration. This attempt
results in ions from the aqueous solution, with the higher concentration trying to “migrate” to the side of the
semi-permeable membrane the lower concentration solution.
This concentration equalisation cannot occur in this way, as the membrane is impermeable for the ions.
Thus, the water molecules, which can penetrate the membrane, ow from the side with the lower concen-
trate to the side with the higher concentration to achieve the equalisation. This process continues until
the concentration equalisation of the ions on both sides has been achieved or so-called osmotic pressure
has become established on the high concentration side. This osmotic pressure is less than 2 bar in drink-
ing water and increases as the different in concentration rises. This process is known as osmosis and, in
nature, is responsible for regulating the water balance in cells.
The bursting of cherries is described below as a clear example of osmosis.
The starting point is a ripe cherry, whose skin is wet with water after a rain shower.
The rain water on the skin of the cherry represents a liquid with lower concentration of dissolved particles.
The cherry juice inside the cherries represents a liquid with high concentration due to the dissolved sugar.
The cherry juice attempts to equalise the concentration with the rain water and wants to diffuse towards
this water. However, this is prevented by the semi-permeable membrane, which retains the sugar mol-
ecules because of their size.
This results in a process in which the water molecules ow from outside into the inside of the cherry and
the pressure in the cherry increases until it can no longer expand and nally bursts.
As the name suggests, reverse osmosis is the converse of the osmosis process.
Tap water represents the side with high ion concentration and is forced towards the pure water with the low
concentration by application of an external pressure.
This externally applied pressure must be higher than the osmotic pressure. This is the only way in which
the water molecules can migrate against their natural osmotic direction into the area with lower concentra-
tion and the substances dissolved in the tap water cannot pass through the semi-permeable membrane
because of their size. Therefore, almost exclusively water molecules remain on the pure water side. The
substances remaining on the membrane must be continuously discharged to prevent clogging of the mem-
brane.
-
5
-
© STULZ GmbH, Hamburg
-
5
-
Reverse osmosis technology
If two solutions with dierent ion concentrations – aqueous solutions with dierent salt content – are separate
by a semi-permeable membrane, the solutions attempt to equalise the concentration. This attempt results in
ions from the aqueous solution with the higher concentration trying to “migrate” to the side of the semi-perme -
able membrane with the lower concentration solution.
This concentration equalisation cannot occur in this way, as the membrane is impermeable for the ions.Thus,
the water molecules, which can penetrate the membrane, flow from the side with the lower concentrate to the
side with the higher concentration to achieve the equalisation. This process continues until the concentration
equalisation of the ions on both sides has been achieved or so-called osmotic pressure has become estab -
lished on the high concentration side.This osmotic pressure is less than 2 bar in drinking water and increases
as the dierent in concentration rises. This process is known as osmosis and, in nature, is responsible for
regulating the water balance in cells.
The bursting of cherries is described below as a clear example of osmosis.
The starting point is a ripe cherry, whose skin is wet with water after a rain shower.
The rain water on the skin of the cherry represents a liquid with lower concentration of dissolved particles.The
cherry juice inside the cherries represents a liquid with high concentration due to the dissolved sugar.
The cherry juice attempts to equalise the concentration with the rain water and wants to diuse towards this
water. However, this is prevented by the semi-permeable membrane, which retains the sugar molecules be -
cause of their size.
This results in a process in which the water molecules flow from outside into the inside of the cherry and the
pressure in the cherry increases until it can no longer expand and finally bursts.
As the name suggests, reverse osmosis is the converse of the osmosis process.
Tap water represents the side with high ion concentration and is forced towards the pure water with the low
concentration by application of an external pressure.
This externally applied pressure must be higher than the osmotic pressure. This is the only way in which the
water molecules can migrate against their natural osmotic direction into the area with lower concentration and
the substances dissolved in the tap water cannot pass through the semi-permeable membrane because of
their size. Therefore, almost exclusively water molecules remain on the pure water side. The substances re -
maining on the membrane must be continuously discharged to prevent clogging of the membrane.
Osmosis principle Reverse osmosis principle
High concentration Low concentration
High concentration
Low concentration
Direction of flow
External pressure
Direction of flow
Membrane
Membrane
6.1. The principle of the reverse osmosis system

STULZ UltraWater 3-stage reverse osmosis system SUW Transport / storage
© STULZ GmbH, Hamburg
-
15
-
-
8
-
© STULZ GmbH, Hamburg
-
8
-
1.3 Lieferumfang
Wasserhahn 12 Liter Wasserspeicher Gehäuseschüssel
Ventil
Zuleitung
Drainageanschluss /
Abflussventil Brauchwasser
Wasseranschlussadapter
Kugelventil
Wasserspeicher
UV-Röhre
Verbindungsschlauch
Membrane
SUW 120: 2 x item 025
SUW 400: 2 x item 025
11-liter pressure tank
1 x item 034
Housing key
SUW 120: 1 x item 036, 1 x item 037
SUW 400: 1 x item 036, 1 x item 037
Corner valve for
pressure tank
1 x item 35
Connecting hose 6mm
SUW 120, 400
black 1 x item 38, red 1 x item 40
blue 1 x item 41, yellow 1 x item 39
Note:
Note:
Choose the fastening materials in accordance with the local conditions.
The item numbers stated here are based on the spare parts lists in section 15 of this manual.
6.2. Product package
STULZ UltraWater reverse osmosis systems are delivered fully preassembled. The system must be tight-
ened and supplied with water and electricity. In addition, it must be connected to the pressure tank. Please
check that your delivered product is correct and complete.
Untreated water connection
1 x item 001
1 x item 008
1 x item 009
Complete 1 x item 042
STULZ UltraWater 120
reverse osmosis system
STULZ UltraWater 400
reverse osmosis system

Transport / storage STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
16
-
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.: +4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.:+4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.: +4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.:+4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.: +4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.:+4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.: +4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.:+4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.: +4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.:+4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.: +4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3 kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.:+4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.: +4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
Typ: UltraWater
Modell:SUW 120 basic
Artikel-Nr.: 1220798
Serien-Nr.:
Herstellungsjahr:/
Spannungsversorgung: 230V/50Hz/N
Nennleistung: 22 VA
Schutzklasse:II
Nennstrom: 0,1 A
Max. Betriebsdruck: 4,0 bar
Schutzart: IP 54
Betriebstemp.:+4 ... +30°C
Max. Druck Wassertank: 3,0 bar
Leergewicht: 9,3kg
Permeatleistung: 12,0 l/h *
Verh. Abwasser / Reinwasser: 1 : 1 *
*bei 500 mg/l Salzgehalt, 4,0 bar, +15 °C,
ohne Gegendruck
STULZ GmbH
Holsteiner Chaussee 283
D-22457 Hamburg
www.stulz.de
Made in Germany
HINWEISE
- Trinkwasser gemäß TrinkwV als Speise-
wasser verwenden.
- Aufbereitetes Reinwasser hat vor Ort
unterschiedl. Leitfähigkeit. Falls erforder-
lich, bauseitig Leitfähigkeit reduzieren.
00
00
00
00
00
00
00
00
00
00
00
00
00
00
2014
2014
2014
2014
2014
2014
2014
2014
2014
2014
2014
2014
2014
2014
6.3. Rating plate
The rating plate contains the most important data for identi cation of the STULZ UltraWater, and concern-
ing the application limits. The rating plate is af xed to the base plate of the UltraWater.
The data on the rating plate are required for the following:
• Safe use of the UltraWater
• When phoning the STULZ hotline with questions
The rating plate must be permanently af xed to the UltraWater.
Manufacturer's
address
Example rating plate
Model
XXXXXX
Serial number CE marking WEEE identi cation
Designation Explanation
CE marking The UltraWater conforms to the requirements of the applicable EU Directives.
WEEE identi cation Do not dispose of the UltraWater with household garbage. Please follow the
applicable disposal regulations for electrical waste.

STULZ UltraWater 3-stage reverse osmosis system SUW Transport / storage
© STULZ GmbH, Hamburg
-
17
-
6.4. Technical data
Model SUW 120 basic SUW 400 basic
Permeation rate3) 12 l/h1) 288 l/d 40 l/h1) 960 l/d
Retention rate 95% 1) 95% 1)
Waste water/pure water ratio 1:1 1) 1:1 1)
Operating temperature 4…30°C 4…30°C
Ambient temperature 5…35°C 5…35°C
Intake pressure 1 - 5 bar 1 - 5 bar
Operating pressure Max. 4 bar Max. 4 bar
Water connections 6 mm 6 mm
Electrical connection 230 V, 50Hz 230 V, 50Hz
Nominal current 0.1 A 0.5 A
Protection class II II
Protection rating IP54 IP54
Pressure tank volume (total) 11 l 11 l
Minimum lter service life (depending on untreated water)2) Approx. 6 - 12 months Approx. 3 - 6 months
Max. operating pressure of pressure tank 3 bar 3 bar
Minimum membrane service life (depending on untreated water) Approx. 2 years Approx. 2 years
Device dimensions (WxHxD) (580 x 410 x 150) mm (580 x 410 x 150) mm
Pressure tank dimensions (DixH) (240 x 360) mm (240 x 360) mm
Empty weight of device 9.3 kg 9.9 kg
Empty weight of pressure tank 2.4 kg 2.4 kg
1) With salt content 500 mg/l, 4 bar, water temperature +15°C, no back pressure. At a lower water temperature, the permeation rate declines.
2) With concentrations > 0.1 mg/l of free chlorine in the drinking water, the service life of the pre lter must be halved.
3) The system produces up to 40% less pure water that the nominal gure in winter, but up to 60% more in the summer.
6.5. Application limits
Maximum untreated water temperature +35°C
Maximum untreated water conductivity 400 μS/cm
Maximum untreated water hardness 15°dH
Maximum Silt Density Index SDI SDI <3
Iron concentration < 0.1 mg/l
Manganese concentration < 0.05 mg/l
Microbiological requirement acc. to TrinkwV
Drinking water as per local Drinking Water Regulations!

Transport / storage STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
18
-
3
Bedrijfscondities
Maximale watertemperatuur: 45°C
Maximale geleidbaarheid: 2.000 µS/cm
Maximale hardheid: 30 °dH
Maximale SDI (Silt Density Index): SDI 5
IJzer- en mangaanconcentratie: onder 0,1 mg/l
Hard drinkwater en bronwater kan de standtijd van de filters en de membranen,
evenals de kwaliteit van het gedemineraliseerde water, negatief beïnvloeden.
Eventueel kan het gebruik van een waterontharder zinvol zijn. Tot de bedrijfscondi-
ties van de installatie behoren bacteriënconcentraties conform de drinkwaterverorde-
ning en mag er zich geen strontium en barium in het leidingwater bevinden.
Technische uitrusting
• 12-Liter-waterreservoir voor gedemineraliseerd water
• Compleet vooraf gemonteerd voor een eenvoudige en
kostenbesparende installatie
• Inclusief alle filters, UV-lamp en meetapparatuur voor de
geleidbaarheid
• Alle voor de aansluiting aan het leidingwaternet benodigde
stekkers en koppelingen
• 2-Meter aansluitslangen, kleur gecodeerd, voor leiding-
water, afvalwater, permeaat en waterreservoirleiding
• Regelaar voor de permanente meting van de geleidbaar-
heid en automatisch spoelen van de membranen
• Bedrijfsurenteller
• Hogedrukpomp voor een hogere efficiëntie van het
membraan
• UV-lamp in roestvast stalen behuizing voor de desinfectie
van het gedemineraliseerde water
• Drie voorfilters voor een maximale standtijd van de
membraan
• Filterbehuizing met dubbele O-ring afdichting
• Automatische afsluiter en terugslagklep van roestvast staal
• Vuilafscheider
6-fasen omgekeerde osmosesysteem
Fase 1:
5-µm-sedimentfilter verwijdert stof, roest en verdere deeltjes
(min. 6 maanden standtijd)
Fase 2:
Actief koolfilter verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën
(min. 6 maanden standtijd)
Fase 3:
Koolstofblok verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën,
om o. a. het membraan te beschermen (min. 6 maanden standtijd)
Fase 4:
TFC-membraan verwijdert bestanddelen als lood, koper, barium, chroom, kwikzilver, natrium, cadmium,
fluoride, nitrieten, nitraten en selenium (min. 2 jaar standtijd)
Fase 5:
Koolfilter verwijdert overgebleven residuen en geuren
(min. 1 jaar standtijd)
Fase 6:
UV-licht voor de desinfectie resp. het doden van vrije virussen en bacteriën in het water met UVC-stralen
(min. 1 jaar standtijd)
3
Bedrijfscondities
Maximale watertemperatuur: 45°C
Maximale geleidbaarheid: 2.000 µS/cm
Maximale hardheid: 30 °dH
Maximale SDI (Silt Density Index): SDI 5
IJzer- en mangaanconcentratie: onder 0,1 mg/l
Hard drinkwater en bronwater kan de standtijd van de filters en de membranen,
evenals de kwaliteit van het gedemineraliseerde water, negatief beïnvloeden.
Eventueel kan het gebruik van een waterontharder zinvol zijn. Tot de bedrijfscondi-
ties van de installatie behoren bacteriënconcentraties conform de drinkwaterverorde-
ning en mag er zich geen strontium en barium in het leidingwater bevinden.
Technische uitrusting
• 12-Liter-waterreservoir voor gedemineraliseerd water
• Compleet vooraf gemonteerd voor een eenvoudige en
kostenbesparende installatie
• Inclusief alle filters, UV-lamp en meetapparatuur voor de
geleidbaarheid
• Alle voor de aansluiting aan het leidingwaternet benodigde
stekkers en koppelingen
• 2-Meter aansluitslangen, kleur gecodeerd, voor leiding-
water, afvalwater, permeaat en waterreservoirleiding
• Regelaar voor de permanente meting van de geleidbaar-
heid en automatisch spoelen van de membranen
• Bedrijfsurenteller
• Hogedrukpomp voor een hogere efficiëntie van het
membraan
• UV-lamp in roestvast stalen behuizing voor de desinfectie
van het gedemineraliseerde water
• Drie voorfilters voor een maximale standtijd van de
membraan
• Filterbehuizing met dubbele O-ring afdichting
• Automatische afsluiter en terugslagklep van roestvast staal
• Vuilafscheider
6-fasen omgekeerde osmosesysteem
Fase 1:
5-µm-sedimentfilter verwijdert stof, roest en verdere deeltjes
(min. 6 maanden standtijd)
Fase 2:
Actief koolfilter verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën
(min. 6 maanden standtijd)
Fase 3:
Koolstofblok verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën,
om o. a. het membraan te beschermen (min. 6 maanden standtijd)
Fase 4:
TFC-membraan verwijdert bestanddelen als lood, koper, barium, chroom, kwikzilver, natrium, cadmium,
fluoride, nitrieten, nitraten en selenium (min. 2 jaar standtijd)
Fase 5:
Koolfilter verwijdert overgebleven residuen en geuren
(min. 1 jaar standtijd)
Fase 6:
UV-licht voor de desinfectie resp. het doden van vrije virussen en bacteriën in het water met UVC-stralen
(min. 1 jaar standtijd)
3
Bedrijfscondities
Maximale watertemperatuur: 45°C
Maximale geleidbaarheid: 2.000 µS/cm
Maximale hardheid: 30 °dH
Maximale SDI (Silt Density Index): SDI 5
IJzer- en mangaanconcentratie: onder 0,1 mg/l
Hard drinkwater en bronwater kan de standtijd van de filters en de membranen,
evenals de kwaliteit van het gedemineraliseerde water, negatief beïnvloeden.
Eventueel kan het gebruik van een waterontharder zinvol zijn. Tot de bedrijfscondi-
ties van de installatie behoren bacteriënconcentraties conform de drinkwaterverorde-
ning en mag er zich geen strontium en barium in het leidingwater bevinden.
Technische uitrusting
• 12-Liter-waterreservoir voor gedemineraliseerd water
• Compleet vooraf gemonteerd voor een eenvoudige en
kostenbesparende installatie
• Inclusief alle filters, UV-lamp en meetapparatuur voor de
geleidbaarheid
• Alle voor de aansluiting aan het leidingwaternet benodigde
stekkers en koppelingen
• 2-Meter aansluitslangen, kleur gecodeerd, voor leiding-
water, afvalwater, permeaat en waterreservoirleiding
• Regelaar voor de permanente meting van de geleidbaar-
heid en automatisch spoelen van de membranen
• Bedrijfsurenteller
• Hogedrukpomp voor een hogere efficiëntie van het
membraan
• UV-lamp in roestvast stalen behuizing voor de desinfectie
van het gedemineraliseerde water
• Drie voorfilters voor een maximale standtijd van de
membraan
• Filterbehuizing met dubbele O-ring afdichting
• Automatische afsluiter en terugslagklep van roestvast staal
• Vuilafscheider
6-fasen omgekeerde osmosesysteem
Fase 1:
5-µm-sedimentfilter verwijdert stof, roest en verdere deeltjes
(min. 6 maanden standtijd)
Fase 2:
Actief koolfilter verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën
(min. 6 maanden standtijd)
Fase 3:
Koolstofblok verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën,
om o. a. het membraan te beschermen (min. 6 maanden standtijd)
Fase 4:
TFC-membraan verwijdert bestanddelen als lood, koper, barium, chroom, kwikzilver, natrium, cadmium,
fluoride, nitrieten, nitraten en selenium (min. 2 jaar standtijd)
Fase 5:
Koolfilter verwijdert overgebleven residuen en geuren
(min. 1 jaar standtijd)
Fase 6:
UV-licht voor de desinfectie resp. het doden van vrije virussen en bacteriën in het water met UVC-stralen
(min. 1 jaar standtijd)
6.6. Filter service life
Filter Description Service life1) 2)
SUW 120 SUW 400
Stage 1 Combination lter
(asymmetrical composite material) 6 months 3 months
Removes gaseous substances, e.g. chlorine and particles > 5µm.
Stage 2 TFC membrane (thin lm composite) 2 years 2 years
Removes hardness elements and other minerals, such as lead,
copper, chromium, mercury, sodium, cadmium, uoride, nitrites,
nitrates, selenium and organic substances with a high and
medium molecular weight, such as pesticide and drug residues.
Stage 3 Combination lter
(asymmetrical composite material) 12 months 12 months
Removes gaseous substances, e.g. chlorine, particles and odors.
1) At rates of up to 150 l/h. If the untreated water contains chlorine (concentration >0.1 mg/l), this reduces the lter service life by up to 50%!
2) The lter service life may be shorter or even longer in isolated cases, depending on the local conditions.
Regular visual inspections must be performed.
Note:
We recommend performing test measurements to determine conductivity over a longer period,
so that the cycle times can be ascertained for your particular application. For this purpose, we
recommend installing a measuring branch pipe in the device outlet.
3
Bedrijfscondities
Maximale watertemperatuur: 45°C
Maximale geleidbaarheid: 2.000 µS/cm
Maximale hardheid: 30 °dH
Maximale SDI (Silt Density Index): SDI 5
IJzer- en mangaanconcentratie: onder 0,1 mg/l
Hard drinkwater en bronwater kan de standtijd van de filters en de membranen,
evenals de kwaliteit van het gedemineraliseerde water, negatief beïnvloeden.
Eventueel kan het gebruik van een waterontharder zinvol zijn. Tot de bedrijfscondi-
ties van de installatie behoren bacteriënconcentraties conform de drinkwaterverorde-
ning en mag er zich geen strontium en barium in het leidingwater bevinden.
Technische uitrusting
• 12-Liter-waterreservoir voor gedemineraliseerd water
• Compleet vooraf gemonteerd voor een eenvoudige en
kostenbesparende installatie
• Inclusief alle filters, UV-lamp en meetapparatuur voor de
geleidbaarheid
• Alle voor de aansluiting aan het leidingwaternet benodigde
stekkers en koppelingen
• 2-Meter aansluitslangen, kleur gecodeerd, voor leiding-
water, afvalwater, permeaat en waterreservoirleiding
• Regelaar voor de permanente meting van de geleidbaar-
heid en automatisch spoelen van de membranen
• Bedrijfsurenteller
• Hogedrukpomp voor een hogere efficiëntie van het
membraan
• UV-lamp in roestvast stalen behuizing voor de desinfectie
van het gedemineraliseerde water
• Drie voorfilters voor een maximale standtijd van de
membraan
• Filterbehuizing met dubbele O-ring afdichting
• Automatische afsluiter en terugslagklep van roestvast staal
• Vuilafscheider
6-fasen omgekeerde osmosesysteem
Fase 1:
5-µm-sedimentfilter verwijdert stof, roest en verdere deeltjes
(min. 6 maanden standtijd)
Fase 2:
Actief koolfilter verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën
(min. 6 maanden standtijd)
Fase 3:
Koolstofblok verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën,
om o. a. het membraan te beschermen (min. 6 maanden standtijd)
Fase 4:
TFC-membraan verwijdert bestanddelen als lood, koper, barium, chroom, kwikzilver, natrium, cadmium,
fluoride, nitrieten, nitraten en selenium (min. 2 jaar standtijd)
Fase 5:
Koolfilter verwijdert overgebleven residuen en geuren
(min. 1 jaar standtijd)
Fase 6:
UV-licht voor de desinfectie resp. het doden van vrije virussen en bacteriën in het water met UVC-stralen
(min. 1 jaar standtijd)
6.7. Factory settings
The reverse osmosis system is delivered with the following factory settings:
Item Part Function Factory setting Adjustable
4. Intake pressure switch NO 0.5 … 1.0 bar (hysteresis) No
5. Inlet solenoid valve NC --- Yes
11. Tank pressure switch NC 2.0 … 3.0 bar (hysteresis) No
16. Pressure setting valve Buttery
valve
SUW120: approx. 15 l/h at 4 bar
SUW400: approx. 30 l/h at 4 bar
Yes
2-3 bar
Gehäuse entgraten,
O-Ring mitVaseline
LOW
5
4
11
16
3
Bedrijfscondities
Maximale watertemperatuur: 45°C
Maximale geleidbaarheid: 2.000 µS/cm
Maximale hardheid: 30 °dH
Maximale SDI (Silt Density Index): SDI 5
IJzer- en mangaanconcentratie: onder 0,1 mg/l
Hard drinkwater en bronwater kan de standtijd van de filters en de membranen,
evenals de kwaliteit van het gedemineraliseerde water, negatief beïnvloeden.
Eventueel kan het gebruik van een waterontharder zinvol zijn. Tot de bedrijfscondi-
ties van de installatie behoren bacteriënconcentraties conform de drinkwaterverorde-
ning en mag er zich geen strontium en barium in het leidingwater bevinden.
Technische uitrusting
• 12-Liter-waterreservoir voor gedemineraliseerd water
• Compleet vooraf gemonteerd voor een eenvoudige en
kostenbesparende installatie
• Inclusief alle filters, UV-lamp en meetapparatuur voor de
geleidbaarheid
• Alle voor de aansluiting aan het leidingwaternet benodigde
stekkers en koppelingen
• 2-Meter aansluitslangen, kleur gecodeerd, voor leiding-
water, afvalwater, permeaat en waterreservoirleiding
• Regelaar voor de permanente meting van de geleidbaar-
heid en automatisch spoelen van de membranen
• Bedrijfsurenteller
• Hogedrukpomp voor een hogere efficiëntie van het
membraan
• UV-lamp in roestvast stalen behuizing voor de desinfectie
van het gedemineraliseerde water
• Drie voorfilters voor een maximale standtijd van de
membraan
• Filterbehuizing met dubbele O-ring afdichting
• Automatische afsluiter en terugslagklep van roestvast staal
• Vuilafscheider
6-fasen omgekeerde osmosesysteem
Fase 1:
5-µm-sedimentfilter verwijdert stof, roest en verdere deeltjes
(min. 6 maanden standtijd)
Fase 2:
Actief koolfilter verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën
(min. 6 maanden standtijd)
Fase 3:
Koolstofblok verwijdert chloor, geuren, organische vreemde stoffen, pesticiden en chemicaliën,
om o. a. het membraan te beschermen (min. 6 maanden standtijd)
Fase 4:
TFC-membraan verwijdert bestanddelen als lood, koper, barium, chroom, kwikzilver, natrium, cadmium,
fluoride, nitrieten, nitraten en selenium (min. 2 jaar standtijd)
Fase 5:
Koolfilter verwijdert overgebleven residuen en geuren
(min. 1 jaar standtijd)
Fase 6:
UV-licht voor de desinfectie resp. het doden van vrije virussen en bacteriën in het water met UVC-stralen
(min. 1 jaar standtijd)
SUW 120 SUW 400
2-3 bar
Gehäuse entgraten,
O-Ring mitVaseline
LOW
5
4
11
16

STULZ UltraWater 3-stage reverse osmosis system SUW Transport / storage
© STULZ GmbH, Hamburg
-
19
-
6.8. Device construction
6.8.1. UltraWater 120
2-3 bar
A
Gehäuse entgraten,
O-Ring mit Vaseline
LOW
B
C
D
(3)
13
2
5
4
11 (3)
10
14
8
12
(9)
6
7
16
1
15
1. Untreated water connection
2. Prelter with
3. combination lter insert
4. Intake pressure switch
5. Inlet solenoid valve
6. Booster pump with
7. Transformer
8. Reverse osmosis module housing with
9. reverse osmosis membrane
10. Non-return valve
11. Tank pressure switch
12. Corner valve for
13. pressure tank
14. Afterlter with combination lter insert
15. Flow restrictor
16. Pressure setting valve (for plant maintenance only).
The system comprises an installation board with the actual reverse osmosis systems, and a pressure tank
for storing the pure water:
Terminal assignments:
A. Drinking water mains supply
B. Concentrate for sewage system
C. Connection to pressure tank
D. Pure water connection to consumer.

Transport / storage STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
20
-
2-3 bar
A
Gehäuse entgraten,
O-Ring mitVaseline
LOW
B
C
D
(3)
13
2
5
4
11 (3)
10
14
8
12
(9)
6
7
16
1
15
1. Untreated water connection
2. Prelter with
3. combination lter insert
4. Intake pressure switch
5. Inlet solenoid valve
6. Booster pump with
7. Transformer
8. Reverse osmosis module housing with
9. reverse osmosis membrane
10. Non-return valve
11. Tank pressure switch
12. Corner valve for
13. pressure tank
14. Afterlter with combination lter insert
15. Flow restrictor
16. Pressure setting valve (for plant maintenance only).
The system comprises an installation board with the actual reverse osmosis systems, and a pressure tank
for storing the pure water:
Terminal assignments:
A. Drinking water mains supply
B. Concentrate for sewage system
C. Connection to pressure tank
D. Pure water connection to consumer.
6.8.2. UltraWater 400
This manual suits for next models
2
Table of contents
Popular Water Filtration System manuals by other brands

Olympus
Olympus MAJ-2307 instructions

Koganei
Koganei iB-Cyclone iBSeries Handling Instructions and Precautions

Schaffner
Schaffner FN 3025 Installation guidelines

AquaMaster
AquaMaster AMS700 Owner's manual and installation guide

Westfalia
Westfalia 15 36 27 instruction manual

Oase
Oase AquaMax Eco Expert 21000 operating instructions