SUBURBAN
MANUFACTURING
COMPANY
Post
OfRce
Box
399
Dayton,
Tennessee37321
.
.U~SI~I.W
AIRXCEL,
Inc.
USER'S INFORMATIONMANUAL
For
Models
SH-35 SH-42
SH-35F SH-42F
This
book
contains instfuctions covering
the
operatlon
and
maintenanceofyour furnace.
Keep
with
unitat all times.
Should
you
requirefurther
information,
contact
yourdealer
or
nearest
SuburbanService Center.
WARNING! Installation of this appliance
must be made in accordance wlth the
written instructions provided in this
manual. No agent, representative or
employee of Suburban or other person
has the authority to change, modify or
waive any provision of the instructions
containedinthis manual.
WARNING! Improper installation,
adjustment, alteration, service or
maintenancecancausepropertydamage,
personalinjuryor lossof life. Refertothe
installation instructions andlor owners
manual providedwith this appliance.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity ofthis orany otherappliance.
WHAT TO DO
IF
YOU
SMELL GAS
Extinguishany openflame.
Evacuateallpersonsfromthevehicle.
Shut off the gas supply at the gas
containerorsource.
Do nottouch any electrical switch, or
useany phoneor radiointhevehicle.
Do not start the vehicle's engine or
electric generator.
Contact the nearest gas supplier or
qualifiedservicetechnicianfor repairs.
If
you cannot reach a gas supplier or
qualifiedservicetechnician,contactthe
nearestfiredepartment.
Donotturnonthegassupplyuntilthe
gas Ieak(s) has been repaired.
Installation and service must be
performed by a qualified installer,
serviceagency orthe gas
supplier.
[~ersonalinjury, propertydamage or lossof le.
I
I
WARNlNGlDonotInstallscreensovertheventforany
roam.
Sawens
willbecomerestrictedandcauseunsafefumrcsoperatlon. Accessorlet
I
MAINTENANCEAND CLEANING
CAUTION: Label all wires before disconnecting for servlcing. Proper
polaritymust
be
observed
so
the furnace motor will
run
wlththe proper
direction
of
rotation
to
Insurecorrect alr delhry
(See
WiringDiagram.)
CAUTION: Labelallwires
prior
todlsconnectlon when servlcingcontrols.
WlrlngemcancauseImproperanddangerousfurnaceoperatlon.
WARNING1
W
the urer of this a pllance falls
to
mlntain
n
In the
conditionInwhich
tt
was
shipped
hrn
thefactoryor
If
theapplianceIs
notused
solelyfor
Its
IntendedpurposeorIfappllanC01snotmalntalned
InaccordancewlththeInstructtonsInthis
It'm'IUl,
then
the
riskof afire
andlor
the
~raductlonof carbon monoxide exists whlch can cause
Always
verffy
properoperationoffurnace after servicing.
Listed
below
are severalsafeyrelateditemsthat
YOU
shouldfdkwduring
the
season
assure
can4inued
safe
Of
the
furnace.
1.
Inspectfurnace venting. Venting must
be
freeof obstructions, vddof soot
and properly
terminated
to
the
atmosphere. (Refer
to
installalionmanuel.)
You, as
the
ownerluser, should Inspect
the
furnace monthlyduring the
heatingseasonfor presenceof soot
on
vent Operating
the
furnace
underthis
conditioncould
lead
toserlwspropertydamage, personalInjuryor lossoflife.
If
soot
is
observedon
the
vent, Immediatelyshutfurnace down and contact a
qualifiedserviceagency.
are beingmarketedfor
RV
productswhich
w
donotrucommend.
For
your safety, only factory authorfxed park
are
to be
usad
on your
furnace.
I
2.
PeriodicallyInspect the vent for obstructions
or
presenca of
soot.
Soot is
formed
whenevercombustionisincomplete.Thisisyourvisualwarningthat the
fumaceisoperatinginan unsafe manner. Ifsoot
is
present. immediately shut
furnacedown and contactyourdealeror a qualifiedservlca person.
3.
Periodicallyobservethe mainbumerflame loassureitisburningwithahard
blueflame
with
welldefinedbumer
ports
(See
Figure
2).
Ifflameappearsyellow
or bumerhas a lazyflame. shut furnacedown.
It
ispossiblethat bumer needs
cleaning or replaced.
If
excessiverust and corrosionare present
cm
burner
surface,theburnermust
be
thoroughlycleanedor replaced.Theburnermaybe
cleaned usinga sledwire brush and blownclean usinghighcompressionair.
Contada qualifedservicepersonforassistance.