Sun Microsystems StorEdge S1 Array User manual

Sun StorEdgeS1 Array
Just the Facts
(SunWIN token# 314474)

Copyrights
© 1999, 2000, 2001 Sun Microsystems, Inc. All Rights Reserved.
Sun, Sun Microsystems, the Sun logo, Sun StorEdge, Solaris, Sun Cluster, Sun Enterprise, Sun Fire,
SunSpectrum, SunSwift, and Netra are trademarks or registered trademarks of Sun Microsystems, Inc. in
the United States and other countries.
Sun StorEdge S1 Array
Just the Facts 314474.int.sdw 9/27/01

Table of Contents
Sun StorEdge™ S1 Array Positioning.................................................................................................1
Introduction........................................................................................................................................1
Product Family Placement.................................................................................................................1
Storage/Serviceability Features..........................................................................................................1
Key Messages...................................................................................................................................2
New Features....................................................................................................................................2
Availability..........................................................................................................................................2
Target Users......................................................................................................................................3
Target Markets...................................................................................................................................3
Selling Highlights ................................................................................................................................4
Market Value Proposition...................................................................................................................4
Applications.......................................................................................................................................4
Compatibility......................................................................................................................................4
Enabling Technology ..........................................................................................................................5
Technology Overview.........................................................................................................................5
Clustering..........................................................................................................................................5
Carrier−Grade Features.....................................................................................................................5
Form Factor.......................................................................................................................................5
Daisy Chaining...................................................................................................................................5
Data Storage Capabilities...................................................................................................................6
System Architecture.............................................................................................................................7
Overview...........................................................................................................................................7
Sun StorEdge S1 Array Features and Benefits...................................................................................7
System Architecture...........................................................................................................................9
Disk Tray Key Facts...........................................................................................................................9
Storage Subsytem Manager...............................................................................................................9
Enclosure Service............................................................................................................................10
Front Panel Indicators .....................................................................................................................10
Rear Panel Indicators and Switches.................................................................................................11
Sun StorEdge S1 Array DC Version.................................................................................................12
Reliability, Availability, and Serviceability (RAS)..............................................................................13
Reliability.........................................................................................................................................13
Availability........................................................................................................................................13
Serviceability....................................................................................................................................13
Installation Data..................................................................................................................................14
Electrical Requirements....................................................................................................................14
Chassis Dimension and Weight........................................................................................................15
Environment.....................................................................................................................................15
Regulations......................................................................................................................................16
Requirements and Configuration.......................................................................................................17
System Requirements......................................................................................................................17
System Configuration.......................................................................................................................17
Sun StorEdge S1 Array Basic Configuration.....................................................................................18
Licensing/Usage...............................................................................................................................19
Interconnect.....................................................................................................................................19
System Management..........................................................................................................................20
Standards/Conformance...................................................................................................................20
Sun StorEdge S1 Array
Just the Facts 314474.int.sdw 9/27/01

Software..........................................................................................................................................20
Other Late Breaking News...............................................................................................................20
Internationalization...........................................................................................................................20
Ordering Information..........................................................................................................................21
Base Models....................................................................................................................................21
Other Base Models..........................................................................................................................21
Options............................................................................................................................................21
Upgrades.............................................................................................................................................23
Upgrade Paths.................................................................................................................................23
Service and Support...........................................................................................................................24
Warranty..........................................................................................................................................24
Education.........................................................................................................................................24
Glossary..............................................................................................................................................25
Materials Abstract...............................................................................................................................27
Internal Information............................................................................................................................28
Competitive Information...................................................................................................................28
Sun StorEdge S1 Array
Just the Facts 314474.int.sdw 9/27/01

Sun StorEdge™ S1 Array Positioning
Introduction
The Sun StorEdge™ S1 array is a rackable, thin storage product that is 1 rack unit (1 U) high, with
multiple rackmounting options. The Sun StorEdge S1 array can house up to three 18 GB or three 36 GB
SCSI disk drives. This product is designed to be an affordable, versatile, rackmountable, incremental
storage solution for a wide variety of markets.
Its 1U form factor enables companies to maximize rack density, thereby minimizing the use of valuable
vertical space. Products which occupy less space are essentially less expensive to maintain and operate.
Potential applications for the Sun StorEdge S1 array include hot−swap disks for rackmount servers, hot−
swap boot disks, hot−swap mirroring of systems and data disks for rackmount servers, and incremental
storage.
Telcordia NEBS Level 3 certified, the unit ships with a number of NEBS features that certify the fire
proof and fire resistant enclosure to withstand Zone 4 earthquakes, operate within compliant levels of
EMI and ESD, and to operate in environments with non−ambient temperature, high humidity, and
airborne contaminants. These features not only meets the demands of telecoms, service providers, and
military entities, but also provides unparalleled peace of mind at no extra cost to other customers who
may not experience such environmental extremes.
To support deployment in today’s typical data center, various rackmount support options are standard. A
choice of AC or –48V/–60V DC power is also available.
Product Family Placement
The Sun StorEdge S1 array—part of the StorEdge family of storage solutions—is the next generation of the
Netra™ st D130 storage array. The Sun StorEdge S1 array is a low−profile, rackmounted, low−cost thin
storage that provides incremental storage for Netra and other Sun servers.
Storage/Serviceability Features
Up to three hot−swap 18 or 36 GB disks
High performance 10K rpm disks
Ultra3 SCSI LVD, Ultra2 SCSI LVD, or Ultra SCSI SE connect to host
Dual SCSI connectors
Status LEDs on front and back of unit, activity LEDs for each disk
Simplified field replaceable units (FRUs)
Auto termination
Up to four enclosures per SCSI chain
Dual host support on SunCluster software
Labeling area for customer identification
Sun StorEdge S1 Array 1
Just the Facts 9/27/01

Key Messages
The Sun StorEdge S1 array delivers a high−performance, versatile, scalable, rack−optimized, and cost−
effective solution for customers seeking to complement their existing Sun servers with incremental
storage.
Hot−swappable, incremental storage for Netra and Sun Enterprise™ servers and cluster applications
1 rack unit high, 18−inch depth, rackmount−ready enclosure
Up to three hot−swappable, 18 GB or 36 GB, 10K rpm high performance disk drives (JBOD)
Ultra3 SCSI LVD, Ultra2 SCSI LVD, or Ultra SCSI SE direct connect to standard port on Sun servers
Scalable up to four daisy−chained enclosures
12 meters of cabling length
Up to 160 Mbytes/sec transfer rate
Status LEDs for FRUs
Remote monitoring software for Sun server hosts
NEBS Level 3 ruggedized
Choice of AC or –48 V DC power
Dual cooling fans
Isolated ground chassis (DC Power)
Rack options for 19−inch, 23−inch, 24−inch and 600−mm standard enterprise and telecom racks
Carrier−grade serviceability features
Quick deployment, easy maintenance, high MTBF
New Features
The Sun StorEdge S1 array features higher performance, more rack−planning flexibility, and greater
scalability than its predecessor, the Netra st D130 storage array.
Feature Sun StorEdge S1 Array Netra st D130 Storage Array
Host Interface Ultra3 SCSI LVD Ultra SCSI SE
Transfer Rate Up to 160 Mbytes/sec Up to 40 Mbytes/sec
Maximum Cabling Length 12 meters 3 meters
Scalability Up to 4 units or 12 drives Up to 2 units or 6 drives
Availability
18 GB and 36 GB disk drives are now available in both AC− and DC−powered versions
Sun StorEdge S1 Array 2
Just the Facts 9/27/01

Target Users
The Sun StorEdge S1 array is designed to be used by system administrators, system architects, and
telecom system designers. The Sun StorEdge S1 array can be mounted in various rack configurations,
takes up a minimum amount of space, and provides incremental storage at a competitive price.
Target Markets
Below are the industries and key features to highlight that are appropriate for the Sun StorEdge S1 array.
Industry/Customer Key Features to Highlight
•Service Provider
•Data center •1 U form factor
•Rackmountable
•Up to three hot−swappable disks
•High performance 10K rpm disks
•Dual SCSI connectors, up to four enclosures per SCSI chain
•Status LEDs on front and back of unit, activity LEDs for each disk
drive
•Simplified field replaceable units (FRUs)
•Dual host support on Sun Cluster
•Labeling area for customer identification
•Designed to provide continued operation in high humidity, 0–50°C,
earthquake Zone 4
•Choice of AC or DC power
•Telecom
•OEM/Network Equipment
Builders
•Central Office
•1 U form factor
•Telcordia NEBS Level 3 certified
•Choice of AC or DC power
•Rackmountable
•Dual cooling fans
•Up to three hot−swappable disk drives
•Isolated ground chassis (DC version)
•Enterprise
•Financials
•Education
•Manufacturing
•Health Care
•1 U form factor
•Rackmountable
•Up to three hot−swappable disks
•High performance 10K rpm disks
•High performance 10K rpm disks
•Dual SCSI connectors, up to four enclosures per SCSI chain
•Government/Military •1 U form factor
•Designed to provide continued operation in high humidity, 0–50°C,
earthquake Zone 4
•Status LEDs on front and back of unit, activity LEDs for each disk
drive
•Simplified field replaceable units (FRUs)
•Choice of AC or DC power
Sun StorEdge S1 Array 3
Just the Facts 9/27/01

Selling Highlights
Market Value Proposition
The Sun StorEdge S1 array provides the following solutions for customers in a wide range of markets:
Ruggedized, rack−optimized thin storage in space−constrained environments
Incremental storage for Netra and workgroup servers
High performance, fast accessibility to data
Hot−swappable, redundant boot disks for Netra, workgroup, and Enterprise servers
High availability applications (mirroring, clustering)
Cost−effective alternative
Applications
The Sun StorEdge S1 array is targeted at the following applications:
Low−cost incremental storage
Boot device for Sun Enterprise servers
Cluster applications with the Netra T1 server and Sun StorEdge S1 array
Hot−swappable, redundant system disks for Netra and other Sun servers
Ruggedized storage for service providers and telecom
Mirroring—by using up to four Sun StorEdge S1 array units and mirroring software on the host, build
redundant system and data disks with no single point of failure
Web hosting server storage applications
Web caching server storage applications
Compatibility
The Sun StorEdge S1 array is compatible with the following platforms:
Netra t 1400/1405 server(s)
Netra t 1120/1125 server(s)
Netra t1/T1 server(s)
Netra ct 400/800 server(s)
Sun Enterprise 220R server
Sun Fire™ 280R server
Sun Enterprise 420R server
Sun Enterprise 3500 – 6500 server(s) (target Q3FY02)
Sun Enterprise 10000 server (target Q3FY02)
Sun Fire 15K server
Sun Fire 3800 – 6800 server(s) (target Q3FY02)
Sun StorEdge S1 Array 4
Just the Facts 9/27/01

Enabling Technology
Technology Overview
The Sun StorEdge S1 array provides up to 109 GB of storage (436 GB when daisy chained)
incrementally, allowing users to add the amount of storage needed when it is needed. The hot−
swappable, high performance disk drives can be connected directly to the Ultra SCSI port standard on
Sun servers or to Ultra3 SCSI, Ultra2 SCSI, or Ultra SCSI SE host adapters.
Clustering
Clustering configurations with Netra T1, and Netra t 1400/1405 servers provides a high performance,
high availability, low profile system at a competitive price with no single point of failure.
Carrier−Grade Features
NEBS certification and ETSI compliance
AC or DC power
Dual cooling fans
Status LEDs in front and back
Telcordia NEBS Level 3 certified
Ruggedized to operate in earthquake Zone 4 locations
Continuous operation in 50°C for up to 96 hours
Stringent EMI emission control
Flame resistant, fire proof, metal enclosure
Self−contained system design minimizes operational interference to other systems in the same rack
Isolated ground option for DC power
Form Factor
Rackable thin storage, 1 U (1.73" high)
Depth (18.6") of the Sun StorEdge S1 array enables it to fit easily into industry−standard racks without
hanging out of the back, allowing easy access to rear cables
Daisy Chaining
Dual connectors enable daisy chaining of up to four enclosures, supporting up to 436 GB per SCSI
chain or dual hosting in applications such as Sun Cluster
Switch on back of chassis to select SCSI IDs 2, 3, 4 or 10, 11, 12
Refer to the section “Sun StorEdge S1 Array Daisy Chain Configuration" on page 18 for more details
about daisy chaining.
Sun StorEdge S1 Array 5
Just the Facts 9/27/01

Data Storage Capabilities
Up to three hot−swappable, 18 GB or 36 GB, 10K rpm disk drives
Ultra3 SCSI LVD, Ultra2 SCSI LVD, or Ultra SCSI SE connection to standard SCSI port on Sun
servers and to host adapters
Dual SCSI connectors
Auto termination
Connect up to four enclosures per SCSI chain
Two−position switch allows quick selection of SCSI IDs 2, 3, 4 or 10, 11, 12
Supports standard SCA hot−swappable disk drive with spud brackets
Sun StorEdge S1 Array 6
Just the Facts 9/27/01

System Architecture
Overview
The Sun StorEdge S1 array is a rackable thin storage with a 1 U form factor. Its versatility, rack−
optimized and carrier−grade features make it ideally suited for a wide range of customers, from the
telecom and service provider markets to enterprise customers in the financials, education, manufacturing,
and health care arenas. The internal architecture of the Sun StorEdge S1 array is relatively simple,
supporting up to 109 GB of storage, with greater capacities to come as disk capacities grow.
Figure 1. The Sun StorEdge S1 Array
Sun StorEdge S1 Array Features and Benefits
Feature Function Benefit
•1 U form factor •Efficient use of valuable vertical
rack space •Helps reduce total cost of
ownership
•Helps reduce overall operating
and maintenance costs
•Multiple rackmount options,
ships with rails •Easily fits into customer 19",
23", 24", and 600 mm racks •Helps reduce total cost of
ownership
•High performance Ultra3 SCSI
18/36 GB 10K rpm drives •Excellent performance,
interchangeability with other
Sun products (except the Netra
ft 1800 server)
•Helps increase availability and
reliability
•Faster time to market
•Front accessible, hot−swappable
drives •Allows minor configuration
changes without service
interruption
•Helps increase availability
•Helps reduce overall operating
and maintenance costs
Sun StorEdge S1 Array 7
Just the Facts 9/27/01

Feature Function Benefit
•Storage Subsystem Manager
(SSM 2.0) and LED fault lights
front and rear, activity LED for
each drive
•Enables simple status
monitoring of each drive bay,
recognition of faulty unit from
front and rear, thereby
increasing ease of serviceability
•Helps increase availability
•Helps reduce overall operating
and maintenance costs
•Dual SCSI connectors •Enables clustering
configurations, daisy chaining of
up to four enclosures
•Helps increase availability
•Dual cooling fans •Two cooling fans with high
MTBF ratings help reduce the
risk of device faults
•Helps reduce overall operating
and maintenance costs
•Helps maintain data integrity
•Telcordia NEBS Level 3
certification •Certified to withstand Zone 4
earthquakes; operates in non−
ambient climates and within
stringent EMI and ESD levels;
fire proof and fire resistant
enclosure
•Helps increase availability and
reliability
•Helps maintain data integrity
•AC or –48 V DC power options •Works with customer’s power
system enabling easy installation
and operation
•Helps reduce overall operating
and maintenance costs
•Simplified field replaceable units
(FRUs) •Only two FRUs—enclosure and
disks—for easy servicing •Helps reduce overall operating
and maintenance costs
•Competitive pricing •Enables storage expansion in
affordable increments •Helps reduce total cost of
ownership
•Recessed labeling area in front
bezel •Enables customer to easily label
and identify units •Helps reduce overall operating
and maintenance costs
•Auto termination •No termination plugs needed •Helps reduce overall operating
and maintenance costs
Sun StorEdge S1 Array 8
Just the Facts 9/27/01

System Architecture
AC or DC power supply
Dual cooling fans
Dual SCSI connectors with Ultra3 SCSI LVD, Ultra2 SCSI LVD, or Ultra SCSI single−ended
interface to host
Figure 2. Sun StorEdge S1 Array Enclosure
Disk Tray Key Facts
Each Sun StorEdge S1 array disk tray holds a maximum of three, low profile, 3.5−inch, hot−pluggable
disk modules.
All drives are mounted in a spud bracket for easy installation and removal from the tray.
High performance, 10K rpm, 18 or 36 GB drives.
The drives use SCA−2 connectors in which the ground leads make first contact for hot−pluggable
support. This enables electrical hot plugging. The cable−free drives plug directly into the backplanes to
provide higher reliability.
Storage Subsytem Manager
The Sun StorEdge S1 array comes with Storage Subsystem Manager 2.0, allowing customers to monitor
the Sun StorEdge S1 array from any system in the network running the Solaris™ Operating Environment
for temperature, status, or disk drive information.
Sun StorEdge S1 Array 9
Just the Facts 9/27/01

Enclosure Service
Enclosure services provide and/or accept configuration and maintenance information. Information about
the Sun StorEdge S1 array is obtained through physical inspection of the unit or through software
(downloadable from the Web; refer to http://webhome.ebay/networkstorage/products for details.)
The following components generate or receive enclosure status or control information:
Power supply (local only)
Cooling fans (local only)
Disk drives
Front Panel Indicators
Figure 3. Front Panel System Power/Fault Indicators
Figure 4. Front Panel Disk Drive LEDs
Sun StorEdge S1 Array 10
Just the Facts 9/27/01

Rear Panel Indicators and Switches
Figure 5. Rear View
Figure 6. SCSI ID Switch
Figure 7. Rear Panel LEDs
Sun StorEdge S1 Array 11
Just the Facts 9/27/01

Sun StorEdge S1 Array DC Version
Figure 8 shows the back of the DC version of the Sun StorEdge S1 array chassis. Note that there are two
DC connectors. DC connectors are available as an X−option and come in sets of 10. Two connectors are
typically needed per Sun StorEdge S1 array. These connectors can be used for other DC−powered
products in the Netra product family of servers, storage, and peripherals.
Figure 8. Rear of DC Unit
Figure 9 shows a DC connector and the placement of the input power cables. For more information about
setting up the DC connectors, refer to the DC Connector Product Notes.
Note: Customers need to ensure that there is sufficient power to run the added servers, storage, and
peripherals.
Figure 9. DC input power cables
Sun StorEdge S1 Array 12
Just the Facts 9/27/01

Reliability, Availability, and Serviceability (RAS)
Reliability
NEBS Level 3 ruggedness: metal enclosure, can withstand Zone 4 earthquakes and non−ambient
temperatures and operate within stringent EMI and ESD levels
Extremely reliable fans and power supply with high MTBF ratings
Availability
Can be used for high availability mirroring applications
Can be used for high availability clustering applications
Serviceability
Status LEDs in the front and back of the Sun StorEdge S1 array indicate power and enclosure
operating status
Front−accessible, hot−swappable disk drives
Activity LEDs for each disk drive
Uses standard SCSI driver available on Sun host adapters
Server software provides drive statistics and adds functionality, for example, enables remote users to
determine whether individual drives are working
Two field replaceable units (FRUs)—enclosure and drives
Recessed labeling area on the front of the Sun StorEdge S1 array bezel prevents label from
accidentally coming off and allows customers to identify various units
Sun StorEdge S1 Array 13
Just the Facts 9/27/01

Installation Data
Electrical Requirements
AC Source Site Requirements
Electrical Element Requirement
Voltage 100 V AC to 240 V AC (nominal)
Frequency 47–63 Hz
Max. operating current 4.0 amps
Max. surge current •20 amps peak on a cold start (after AC has been off
for more than 200 ms)
•100 amps peak on a warm start (after AC has been
off for less than 200 ms)
Overcurrent protection devices must be provided as part of each host equipment rack.
Circuit breakers are located between the AC source and the Sun StorEdge S1 array enclosure.
Circuit breakers must not trip when presented with inrush current of 100 amps lasting 5 ms.
The power can be disconnected for servicing in any of the following ways:
Disconnect the connector from the power module at the rear of the enclosure.
Turn off the circuit breakers in the rack where the enclosure is mounted.
Disconnect the main plug from the AC source.
DC Source Site Requirements
Electrical Element Requirement
Voltage –48 V DC to –60V DC
Max. operating current 4.0 amps
Max. input surge current •20 amps peak on a cold start (after AC has been off
for more than 200 ms)
•100 amps peak on a warm start (after AC has been
off for less than 200 ms)
Note: The DC power supply range is –40 V DC to –75 V DC, 5 amps max. operating current.
Electrically isolated from any AC source.
Reliably connected to the earth (the battery room positive bus is connected to ground).
Capable of providing up to 200 watts of power per feed pair.
Overcurrent protection devices must be provided as part of each equipment rack.
Circuit breakers must be located between the DC power source and the Sun StorEdge S1 array
enclosure. Two 10−amp, double−pole, fast trip, DC−rated circuit breakers must be used for each
power supply.
Sun StorEdge S1 Array 14
Just the Facts 9/27/01

Chassis Dimension and Weight
U.S. Metric
Height 1.73 in (1 rack unit—1U) 4.4 cm
Width 17.16 in. 43.6 cm
Depth (with front bezel) 18.6 in. 47.2 cm
Weight (without drives) 13 lbs 5.9 kg
Weight (fully loaded) 19.4 lbs 8.8 kg
Shipping Weight (product and
packing) 20 lbs 9.5 kg
Environment
The Sun StorEdge S1 array is designed to meet the following requirements:
Environmental Specifications
Climate Control Location Minimum to Maximum Range
Temperature (dry bulb) Operating 5°C to 40°C (41°F to 104°F)
Storage –25°C to 65°C (–13°F to 149°F)
Transit –25°C to 65°C (–13°F to 149°F)
Short term (96 consecutive hrs) Operating –5°C to 55°C (23°F to 131°F)
Non−operating –40°C to 70°C (–40°F to 158°F)
Temperature derating (max) Operating 3.3°C per 1000m (1.7°F per 1000 ft)
above sea level
Relative humidity (non−
condensing) Operating 5% to 85%
Short term (96 consecutive hrs) Storage 5% to 95%
Transit 5% to 95%
Operating 5% to 90%
Non−operating 5% to 95%
Altitude (based on drives) Operating 0m to 3,000m (0 ft to 10,000 ft)
above sea level
Storage 0m to 12,000m (0 ft to 40,000 ft)
above sea level
Transit 0m to 12,000m (0 ft to 40,000 ft)
above sea level
Heat dissipation (maximum) Operating 150 watts, 512 BTU per hour
Sound power Operating 6.0B, in accordance with ISO 9296
Idle 6.0B, in accordance with ISO 9296
Earthquake Location NEBS requirements for earthquake
Zone 4
Sun StorEdge S1 Array 15
Just the Facts 9/27/01

Regulations
The Sun StorEdge S1 array meets or exceeds the following requirements:
Safety UL 1950, CSA C22.2−No. 950, EN 60650
(73/23/EEC), IEC 950
Emissions CFR Title 47, FCC Part 15, EN 55022 (89/336/EEC)
Immunity EMC Directive (89/336/EEC), EN50082−1
Telecom environment Telcordia: GR−63−CORE, NEBS GR−1089−CORE,
TR−NWT−000295
Compliance
•Telcordia
•Safety
•EMC
•SR–3580 NEBS Level 3 certified
•cULus Mark, TüVGS Mark, CE Mark
•CE Mark (93/68/EEC), FCC authorized Class A
Sun StorEdge S1 Array 16
Just the Facts 9/27/01
Other manuals for StorEdge S1 Array
1
Table of contents
Other Sun Microsystems Disk Array System manuals

Sun Microsystems
Sun Microsystems StorEdge 3320 Instructions for use

Sun Microsystems
Sun Microsystems StorageTek 6140 User manual

Sun Microsystems
Sun Microsystems StorEdge 3000 Series Instructions for use

Sun Microsystems
Sun Microsystems STOREDGE A5000 Service manual

Sun Microsystems
Sun Microsystems Sun StorEdge A3500FC User manual

Sun Microsystems
Sun Microsystems Sun StorEdge A3500 User manual

Sun Microsystems
Sun Microsystems StorEdge MultiPack-FC Setup guide