Hardware Configuration
Guide
Part No. 805-4981-13
December 1999, Revision A
Sun Microsystems, Inc.

Please
Recycle
Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road • Palo Alto, CA 94303-4900 USA. All rights reserved.
This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation.
No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors,
if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers.
Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in
theU.S.andothercountries,exclusivelylicensedthroughX/OpenCompany, Ltd.ForNetscapeCommunicator™,thefollowingnotice applies:
Copyright 1995 Netscape Communications Corporation. All rights reserved.
Sun, Sun Microsystems, the Sun logo, AnswerBook, docs.sun.com, Solaris, StorEdge, Ultra, Ultra Enterprise, and RSM are trademarks,
registered trademarks, or service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license
and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks
are based upon an architecture developed by Sun Microsystems, Inc.
The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges
the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun
holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN
LOOK GUIs and otherwise comply with Sun’s written license agreements.
RESTRICTEDRIGHTS: Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227-14(g)(2)(6/87) and
FAR 52.227-19(6/87), or DFAR 252.227-7015(b)(6/95) and DFAR 227.7202-3(a).
DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-
INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road • Palo Alto, CA 94303-4900 Etats-Unis. Tous droits réservés.
Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la
décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans
l’autorisation préalable et écrite de Sun et de ses bailleurs de licence, s’il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie
relative aux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun.
Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque
déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd. La notice suivante est applicable à
Netscape Communicator™ : Copyright 1995 Netscape Communications Corporation. All rights reserved.
Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, Solaris, StorEdge, Ultra, Ultra Enterprise, et RSM sont des marques de
fabrique ou des marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays. Toutes les marques
SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et
dans d’autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc.
L’interface d’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun
reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d’utilisation visuelle ou graphique
pour l’industrie de l’informatique. Sun détient une licence non exclusive de Xerox sur l’interface d’utilisation graphique Xerox, cette licence
couvrant également les licenciés de Sun qui mettent en place l’interface d’utilisation graphique OPEN LOOK et qui en outre se conforment aux
licences écrites de Sun.
CETTE PUBLICATION EST FOURNIE "EN L’ETAT" ET AUCUNE GARANTIE, EXPRESSE OU IMPLICITE, N’EST ACCORDEE, Y COMPRIS
DES GARANTIES CONCERNANT LA VALEUR MARCHANDE, L’APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION
PARTICULIERE, OU LE FAIT QU’ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS. CE DENI DE GARANTIE NE
S’APPLIQUERAIT PAS, DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU.

Contents iii
Contents
Preface vii
1. SCSI Host Connections 1-1
1.1 Configuration Guidelines 1-2
1.2 Supported SCSI Host Configurations 1-3
1.2.1 Single Host Connected to One Controller Module 1-3
1.2.2 Two Controller Modules Daisy-Chained to
One Host 1-4
1.2.3 Independent Controller Module Connected to Two Hosts 1-5
1.2.4 Multi-Host 1-6
1.3 Ultra 2 Host System Power Connection Requirement 1-7
2. FC-AL Host Connections 2-1
2.1 Configuration Guidelines 2-2
2.2 Supported FC-AL Host Configurations 2-3
2.2.1 Single Host Connected to One Controller Module 2-4
2.2.2 Independent Controller Module Connected to Two Hosts 2-5
2.2.3 Single Host Connected to One Controller Module
Using Hubs 2-6
2.2.4 Single Host Connected to Two Controller Modules
Using Hubs 2-7

iv Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
2.2.5 Single Host Connected to Four Controller Modules in a Loop
Using Hubs 2-9
2.2.6 Multi-Host 2-11
2.3 Setting the Loop ID 2-13
3. Sun StorEdge A3500/A3500FC Configurations 3-1
3.1 StorEdge D1000 Disk Array Settings 3-2
3.1.1 1x2 Configuration 3-3
3.1.1.1 Option Switch 3-3
3.1.1.2 Module ID Switch 3-4
3.1.1.3 SCSI Jumper Cables and Terminators 3-4
3.1.2 1x5 Configuration 3-5
3.1.2.1 Option Switch 3-5
3.1.2.2 Module ID Switch 3-6
3.1.2.3 SCSI Jumper Cables and Terminators 3-6
3.1.3 2x7 Configuration 3-7
3.1.3.1 Option Switch 3-7
3.1.3.2 Module ID Switch 3-8
3.1.3.3 SCSI Jumper Cables and Terminators 3-8
3.1.4 3x15 Configuration 3-9
3.1.4.1 Option Switch 3-9
3.1.4.2 Module ID Switch 3-9
3.1.4.3 SCSI Jumper Cables and Terminators 3-10
3.2 1x2 Cables and Connections 3-11
3.2.1 Driveside SCSI Connections 3-11
3.2.2 Power Connections 3-13
3.3 1x5 Cables and Connections 3-14
3.3.1 Driveside SCSI Connections 3-14
3.3.2 Power Connections 3-16

Contents v
3.4 2x7 Cables and Connections 3-17
3.4.1 SCSI Cable Lengths 3-17
3.4.2 Power Connections 3-19
3.5 3x15 Cables and Connections 3-20
3.5.1 SCSI Cable Lengths 3-20
3.5.2 Connections Between Power Sequencers 3-25
3.5.3 Connections to AC Power Sources 3-25
3.5.4 Power Connections for Expansion Cabinets 3-26
A. Sun StorEdge A3500 and A3500FCSpecifications A-1
A.1 Initial Cold Start Surge Current Specifications A-1

vi Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999

vii
Preface
The Sun StorEdge A3500/A3500FC Hardware Configuration Guide provides
configuration instructions for the Sun StorEdge™ A3500/A3500FC systems. These
instructions are designed for an experienced system administrator.
How This Book Is Organized
Chapter 1 describes configurations for one or two small computer system interface
(SCSI) StorEdge A3500 controller modules connected to one or more hosts. It also
contains information about connecting power to a Sun Ultra™ host system.
Chapter 2 describes configurations for one or two Fibre Channel-Arbitrated Loop
(FC-AL) StorEdge A3500FC controller modules connected to one or more hosts.
Chapter 3 explains how to set up the configurations supported by Sun. It also
includes information about StorEdge D1000 disk array settings and cables and
connections for each configuration.
Appendix A contains specifications for the StorEdge A3500/A3500FC systems.
Using UNIX Commands
This document does not contain information on basic UNIX®commands and
procedures such as shutting down the system, booting the system, and configuring
devices.

viii Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
See one or more of the following for this information:
■Solaris Handbook for Sun Peripherals
■AnswerBook™ online documentation for the Solaris™ software environment
■Other software documentation that you received with your system
Typographic Conventions
Shell Prompts
TABLE P-1 Typographic Conventions
Typeface or
Symbol Meaning Examples
AaBbCc123 The names of commands, files,
and directories; on-screen
computer output.
Edit your .login file.
Use ls -a to list all files.
% You have mail.
AaBbCc123 What you type, when
contrasted with on-screen
computer output.
%su
Password:
AaBbCc123 Book titles, new words or
terms, words to be emphasized.
Command-line variable;
replace with a real name or
value.
Read Chapter 6 in the User’s Guide.
These are called class options.
You must be root to do this.
To delete a file, type rm filename.
TABLE P-2 Shell Prompts
Shell Prompt
C shell machine_name%
C shell superuser machine_name#
Bourne shell and Korn shell $
Bourne shell and Korn shell superuser #

ix
Related Documentation
TABLE P-3 Related Documentation
Title Part Number
Sun StorEdge A3500/A3500FC Controller Module Guide 805-4980
Sun StorEdge A3500/A3500FC Task Map 805-4982
Sun StorEdge Expansion Cabinet Installation and Service Manual 805-3067
Sun StorEdge RAID Manager Controller Replacement Guide 805-7854
Sun StorEdge A3500FC Controller Upgrade Guide 806-0479
Sun StorEdge RAID Manager 6.22 Release Notes 805-7758
Sun StorEdge RAID Manager 6.22 Installation and Support Guide for Solaris 805-7756
Sun StorEdge RAID Manager 6.22 User’s Guide 806-0478
Sun StorEdge RAID Manager 6.1.1 Update 2 Release Notes 805-3656
Sun StorEdge RAID Manager 6.1.1 Installation and Support Guide for Solaris 805-4058
Sun StorEdge RAID Manager 6.1.1 User’s Guide 805-4057
Sun StorEdge RAID Manager 6.2.21 Release Notes for Microsoft Windows NT 805-6890
Sun StorEdge RAID Manager 6.2 Installation and Support Guide for Microsoft
Windows NT 805-6888
Sun StorEdge RAID Manager 6.2 User’s Guide 805-6887

xSun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
Sun Documentation on the Web
The docs.sun.comsm web site enables you to access Sun technical documentation
on the Web. You can browse the docs.sun.com archive or search for a specific book
title or subject at:
http://docs.sun.com
Sun Welcomes Your Comments
We are interested in improving our documentation and welcome your comments
and suggestions. You can email your comments to us at:
Please include the part number of your document in the subject line of your email.

1-1
CHAPTER 1
SCSI Host Connections
This chapter describes configurations for one or two small computer system
interface (SCSI) Sun StorEdge A3500 controller modules connected to one or more
hosts. It also contains information about connecting power to a Sun Ultra™ host
system.
The topics covered in this chapter are:
■Configuration Guidelines—page 1-2
■Supported SCSI Host Configurations—page 1-3
■Single Host Connected to One Controller Module—page 1-3
■Two Controller Modules Daisy-Chained to One Host—page 1-4
■Independent Controller Module Connected to Two Hosts—page 1-5
■Multi-Host—page 1-6
■Ultra 2 Host System Power Connection Requirement—page 1-7
Note – The RAID Manager 6.22 software does not support Ultra 2 host systems.

1-2 Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
1.1 Configuration Guidelines
Use the following guidelines to install and cable or reconfigure your StorEdge A3500
system.
■The part number for the 12 meter SCSI host cable is 530-1886-xx.
■Do not exceed a SCSI bus length of 25 meters (82 feet).
■Make sure that the last StorEdge A3500 controller module in any daisy chain has
a total of two terminators—one in each SCSI OUT port.
■If you are adding a controller module to an already existing configuration, halt all
activity on the SCSI bus before removing any SCSI cables.
■Once you finish cabling the devices and powering on, reboot the system by
typing boot -r at the ok prompt before beginning any SCSI bus activity.
■Perform a system check to make sure that SCSI connections are secure. Look for
fault LEDs on the hardware or error messages in the RAID Manager GUI.
Note – Refer to your server and rack documentation for instructions on grounding
the StorEdge A3500 expansion cabinet.

Chapter 1 SCSI Host Connections 1-3
1.2 Supported SCSI Host Configurations
The illustrations in this section show the SCSI cable connections for the
configurations that are supported by Sun.
■Single Host Connected to One Controller Module
■Two Controller Modules Daisy-Chained to One Host
■Independent Controller Module Connected to Two Hosts
■Multi-Host
1.2.1 Single Host Connected to One Controller Module
FIGURE 1-1 shows one host connected with SCSI cables to one StorEdge A3500
controller module.
FIGURE 1-1 One Host Connected to One Controller Module
Differential SCSI terminators
Host
StorEdge A3500 Controller Module

1-4 Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
1.2.2 Two Controller Modules Daisy-Chained to
One Host
FIGURE 1-2 shows two StorEdge A3500 controller modules daisy-chained with SCSI
cables to one host. You can daisy-chain controller modules in the same or separate
cabinets.
FIGURE 1-2 Two Controller Modules Daisy-Chained to One Host
Note – The SCSI cables between the two controller modules are crossed to prevent
the SCSI IDs for the controllers from conflicting.
Differential SCSI terminators
SCSI cables
Host
StorEdge A3500 Controller Modules

Chapter 1 SCSI Host Connections 1-5
1.2.3 Independent Controller Module Connected to
Two Hosts
FIGURE 1-3 shows one StorEdge A3500 controller module connected with SCSI cables
to two hosts.
FIGURE 1-3 Independent Controller Module Connected to Two Hosts
Differential SCSI terminators
Hosts
StorEdge A3500 Controller Module
SCSI cables

1-6 Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
1.2.4 Multi-Host
FIGURE 1-4 shows a two-node multi-host configuration: one StorEdge A3500
controller module connected with SCSI cables to two hosts.
FIGURE 1-4 Two-Node Multi-Host Configuration
Note – The configuration shown in FIGURE 1-4 requires cluster software for
management.
For more information regarding the two-node multi-host configuration, such as
instructions for setting host SCSI IDs, refer to the Sun™ Cluster documentation that
is shipped with the host system.
For information about StorEdge A3500/A3500FC support for multi-host
configurations, refer to “Frequently Asked Questions” (FAQ) in the Sun StorEdge
RAID Manager 6.1.1 Release Notes (805-3656-xx) and in the Sun StorEdge RAID
Manager 6.22 Release Notes (805-7758-xx) and to the Sun StorEdge RAID Manager
User’s Guide.
Hosts
StorEdge A3500 Controller Module
SCSI cables
SCSI cables
Differential SCSI
terminators

Chapter 1 SCSI Host Connections 1-7
1.3 Ultra 2 Host System Power Connection
Requirement
You can connect a controller module to an Ultra 2 host system; however, you must
connect the power cord of the Ultra 2 host to one of the AC power sequencers in the
expansion cabinet that contains the controller module.
Note – The RAID Manager 6.22 software does not support Ultra 2 host systems.
You need to order one of the following power cords depending on the type of power
sequencer in the expansion cabinet (FIGURE 1-5):
■Ultra Enterprise™ expansion cabinet and StorEdge expansion cabinet—
part number 530-2197
■1422 mm/56-inch Data Center expansion cabinet—part number 180-1189 (United
States) or 180-1190 NEMA (European)
Caution – Failure to connect the power cord correctly as described here may cause
excessive ground current that could damage the system.

1-8 Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
FIGURE 1-5 AC Power Sequencers—Ultra 2 Power Connector
To connect the power cord:
1. Gain access to the AC power sequencers.
See the documentation that came with the expansion cabinet.
2. Route the power cable from the Ultra 2 host under the expansion cabinet frame on
the same side as the power sequencer.
3. Connect the power cord from the Ultra 2 host into the top power connector of
either power sequencer (FIGURE 1-5).
The power connectors are located on the other side of the power sequencer from the
main switch.
4. Reassemble the expansion cabinet.
See the documentation that you received with the expansion cabinet.
Connect Ultra 2
power cord here
Ultra Enterprise
expansion cabinet
and StorEdge
expansion cabinet
power sequencer
1422 mm/56-inch
data center
expansioncabinet
power sequencer

2-1
CHAPTER 2
FC-AL Host Connections
This chapter describes configurations for one or two Fibre Channel-Arbitrated Loop
(FC-AL) Sun StorEdge A3500FC controller modules connected to one or more hosts.
The following topics are covered in this chapter:
■Configuration Guidelines—page 2-2
■Supported FC-AL Host Configurations—page 2-3
■Single Host Connected to One Controller Module—page 2-4
■Independent Controller Module Connected to Two Hosts—page 2-5
■Single Host Connected to One Controller Module Using Hubs—page 2-6
■Single Host Connected to Two Controller Modules Using Hubs—page 2-7
■Single Host Connected to Four Controller Modules in a Loop Using Hubs—
page 2-9
■Multi-Host—page 2-11
■Setting the Loop ID—page 2-13

2-2 Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
2.1 Configuration Guidelines
Use the following guidelines to install and cable or reconfigure your StorEdge
A3500FC system.
Caution – The onboard SOC+ on the I/O board is not qualified yet to work with
the StorEdge A3500FC controller module.
Caution – At this time, only single port connection is qualified on the dual-ported
host bus adapter card.
■The part number for the 15 meter FC-AL host cable is 595-3379-xx; the Marketing
part number is X978A.
■Do not exceed a fiber-optic cable length of 500 meters (1640.5 feet).
■Install 16-bit, differential terminators to both HOST IN connectors on the back of
the controller module (FIGURE 2-1).
FIGURE 2-1 Differential SCSI Terminators on Rear of Controller Module
Differential SCSI terminators—HOST IN
This manual suits for next models
1
Table of contents
Other Sun Microsystems Disk Array System manuals

Sun Microsystems
Sun Microsystems StorEdge 3000 Series Instructions for use

Sun Microsystems
Sun Microsystems Sun StorEdge A3500 User manual

Sun Microsystems
Sun Microsystems StorEdge 3320 Instructions for use

Sun Microsystems
Sun Microsystems StorageTek 6140 User manual

Sun Microsystems
Sun Microsystems StorEdge S1 Array User manual

Sun Microsystems
Sun Microsystems STOREDGE A5000 Service manual

Sun Microsystems
Sun Microsystems StorEdge MultiPack-FC Setup guide