Sun Microsystems SUN-IE100 Series User manual

English
User’s Manual
SUN-IE100 Series
Industrial fiber optic transceiver
All the trademarks mentioned in this manual are registered property of Sun Telecom.
The right to interpret this manual is reserved by Sun Telecom.

Content
1. Description........................................................................................................ 1
2. Features ............................................................................................................... 2
3. Technical parameters.......................................................................................... 2
4. Power Supply....................................................................................................... 4
5. Connection method.............................................................................................. 4
6. Detailed List.......................................................................................................... 6
7. Device test method.............................................................................................. 7
8. Fault judgment ..................................................................................................... 7

F i be r O p t i c S o l u t i o n s P r o v i de r 1/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
1. Description
This series of switch products, is my company specifically for electric power,
transportation, petroleum and petrochemical, factory automation, justice
system, outdoor applications such as monitoring, outdoor equipment box
environment a industrial-grade fiber optic transceiver product development;
The product provides a 100Base SC fiber optic interface, single mode single
fiber/single-mode fiber, SC/LC connector, single-mode standard 20 km
optical fiber transmission distance, could also provide single-mode 40 km /
60 km / 80 km and 80 km or multimode optical fiber transmission distance of
2 km optional; At the same time provide a 10/100 Base-T(X) RJ45 port,
support 10 MBPS and 100 MBPS, full duplex/half duplex and MDI/MDIX
adaptive polarity; This product adopts high performance network exchange
chip, all port supports non-blocking, full speed packet forwarding, ensure the
optical transceiver packet forwarding any additional delay.
This product adopts metal shell, beautiful and sturdy, achieve IP30
protection grade, working temperature and -40 °C ~ 85 °C; And the product
of the average trouble-free working time to over 400, 000 hours;
Non network switches, the products meet the CCC, CE/FCC, EN 61000,
such as standard target of the performance of high stability, high reliability is
the ideal choice for industrial application.

F i be r O p t i c S o l u t i o n s P r o v i de r 2/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
2. Features
The Mini type industrial fiber optic transceivers
1 100 Base-Fx SC optical port, 1 10/100 Base T(X) electricity
Follow the IEEE 802.3 standard
10/100 MBPS, full duplex/half duplex, MDI/MIDX adaptive polarity
Support the broadcast storm inhibition function
Ac/dc power supply adaptive
Power supply voltage 12V~24V DC
6KV lightning protection power supply interface
Aluminum frame, IP30 protection grade
The average trouble-free working time > 400000 hours
3. Technical parameters
Interface
Combo Interfaces
10/100Base-T(X)adaptive RJ45
Ethernet interface
Fiber Interfaces
1000Base-FX,Singlemode
Environment
MTBF
>400,000 hours
Operating Temp.
-40℃~85℃
Storage Temp.
-50℃~100℃
Relative Humidity
5~95%(non-condensing)
Switch Parameters
Packet Buffer
0.5M
MAC Table
1K
Processing Type
The full speed forward

F i be r O p t i c S o l u t i o n s P r o v i de r 3/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Transmission Distance
Electricity
Reach to 100m(CAT5 or CAT5e)
Optical Fiber
Singlemode 20KM
Mechanical structure
Chassis
Aluminum chassis
Protection grade
IP30
Weight
380g
Installation
Independent installation
Size
83 x 50.2 x 25.8mm
ELECTRICAL
Input Power
12V DC
Power Consumption
3W @ 12V DC
Overload Circuitry
Support
Installation
Independent installation
Power Terminal
5.08 mm distance between terminals
Optical Parameters
Wavelength
Double fiber1310nm/1310nm /
single fiber1310nm/1550nm
Fiber Type (um)
Singlemode9/125 /Multimode
62.5/125 or Multimode 50/125

F i be r O p t i c S o l u t i o n s P r o v i de r 4/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
4. Power Supply
Use 5.08 mm spacing between the power input terminals to connect the
power cord.
5. Connection method
Electrical wiring instructions
Ethernet port and terminal equipment and network equipment can use direct
or cross line connecting terminal are RJ45 interface
Gigabit RJ45 interface and serial number as shown on the right
87654321
MB RJ45 interface pin definition as shown in the figure below
MDI/MDI-X Port Pinouts
Pin
MDI-X signal
MDI signal
1
Receive data+(RD+)
Output data+(TD+)
2
Receive data-(RD-)
Output data-(TD-)
3
Output data+(TD+)
Receive data+(RD+)
6
Output data-(TD-)
Receive data-(RD-)
4、5、7、8
unused
instructions
"+" "-" represents the level of polarity

F i be r O p t i c S o l u t i o n s P r o v i de r 5/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Opital Fiber
Tx
Rx
T
R T
R
SC -SC线缆
T
R T
R
线序
notice
!
This equipment use laser signal on optical cable transmission,
accord with the requirement of grade 1 laser product normal operation is
harmless to the eyes. When equipment is working, do not look directly into
light port and fiber end face.
RJ45 ports Status LEDs
Each RJ45 port has two lights, yellow lights for port rate indicators, a
green light for port connection status indicator
Speed (Yellow)
on
1000M working
status
off
10M working status or
no connection
Link/ACT(Green)
on
Link-up
blink
Working
off
Link-down
Fiber Status LEDs
Link
on
Link-up
blink
Working
Power
on
Normal power supply
off
No power supply

F i be r O p t i c S o l u t i o n s P r o v i de r 6/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
Panel shows
6. Detailed List
Accessories
Quantity
Description
Switch
1
Industrial-grade transceiver
Product information
1
Manual, certificate of approval
Power
1
12V 1A DC

F i be r O p t i c S o l u t i o n s P r o v i de r 7/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
7. Device test method
Two computers, each with a 10/100M adaptive, half/full-duplex Ethernet
card, buy this series of products by the customer (single/mould, 10/100M), if
it is double fiber with two root and light port corresponding fiber optic jumper
wire connection, if it is the use of a single fiber is that with light port
corresponding fiber optic jumper wire connection, direct or cross twisted-pair
cable. Set the network card installed on the computer, a fixed IP address,
special power supply connected to the purchased equipment, use
twisted-pair cable to connect computers and transceiver. With fiber optic
jumper wire connects the two buying equipment, such as buying products for
single mode, jump line and the application of single mode. With fiber optic
jumper wire connection, the RX side, the other end to TX, so cross
connection; Using a computer to do the following operations "start - run -
ping the IP address of another computer". Received another computer
communication the information returned to normal, not yet received
complete communication is not normal.
8. Fault judgment
1. The POWER light not on:
The power part of the fault, can test the power of the output voltage is
normal.
2. The LINK: wouldn't light may develop any of the following:
(a) check whether optical fiber links open circuit;
(b) check whether optical fiber line loss is too big, range of equipment
receiving;

F i be r O p t i c S o l u t i o n s P r o v i de r 8/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
(c) check whether the optical fiber interface is connected correctly, TX and
RX connection on the far side, at the bottom of far side at the bottom of the
TX and RX connection;
(d) check optical fiber connector insertion device interface, if jump line type
and device interface matching, whether the device type and fiber optic
matching, matching equipment whether transmission distance and the
actual distance.
3. Electricity port LINK the light not bright, may develop any of the following:
(a) check whether cable short circuit or open circuit;
(b) check wiring type matches; Divided into twisted-pair and parallel lines;
(c) check whether the equipment transmission rate is matching.
4. Network packet loss serious: may develop any of the following:
(a) the purchase equipment of electric port and network device interface, or
duplex mismatch of the device interface;
(b) twisted pair with RJ-45 head has a problem, check;
(c) fiber optic connection issue, whether the jumper wire alignment device
interface, tail fiber and jumper wire and coupler types match, etc.;
(d) check the power converter is working correctly.

F i be r O p t i c S o l u t i o n s P r o v i de r 9/9
www.suntelecom.cn • +86-21-60138638 • ics@suntelecom.cn
An important message from Sun Telecom
We guarantee that any information you supply will remain confidential.
By returning this card, you will automatically be notified about updates,
modifications, and recalibration.

Warranty Registration Card
Serial Number:
Model Number:
Date of Purchase:
Company Name:
CompanyAddress:
TEL: FAX:
E-mail:
Note: Please fax this note within one month from the date of receiving
units.
YOUR OPINION:
Do you have any comments on the quality of this product or the service from
us?
SHANGHAI SUN TELECOMMUNICATION CO., LTD.
Building No.145 Lane 666, Xianing Rd.
Jinshan Industrial Zone, Jinshan District
ShangHai, China 201506
Tel: +86 21 60138638 Fax: +86 21 60138635-401
E-mail: ics@suntelecom.cn
http://www.suntelecom.cn
Table of contents
Popular Transceiver manuals by other brands

Comtech EF Data
Comtech EF Data MBT-4000 Installation and operation manual

Standart Horizon
Standart Horizon HX40 owner's manual

ASCOM
ASCOM TD 92417GB user manual

Bellman & Symfon
Bellman & Symfon BE1433 Medical device information

National Instruments
National Instruments PXIe-5842 Getting started

RTS
RTS KrimpVark user manual