Sunje SIG-30 User manual

3Nomenclatures of parts
▶ Ion Gun (SIG-30)
0302
1The matters of safety
Instruction Manual
SIG-30
Eng
It is recommended that only persons who have sufficient knowledge and experience such as system
designers and responsible persons deal with this product after carefully reading the product manual.
01
* If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
* Do not let the water touch the product. It may cause electric shock or fire due to malfunction.
* When you check or maintain the product, make it sure you turn off the power.
It may cause electric shock or fire due to malfunction.
* Do not use the product at the place where dangerous material such as inflammable or
ignitable material exists. This product is not the product of anti-explosive type.
* This device is made only for industrial uses. You need to ground the device beforehand.
Otherwise, there are in case of malfunction, electric shock, or fire damage.
* This device uses compressed air(CDA). Do not use the device if the CDA cannot be allowed to use.
In some cases, the product malfunction or danger of accident might happen.
* Do not contact the discharge needle or terminal with power applied.
There is a possibility of electric shock or malfunction.
* Handle the discharge needle with care as its tip is very sharp.
* Connect wires referring to the product manual. Wrong connection can cause failures.
* Do not use the product for the purpose outside of the range of the product use.
If the product is used for the purpose outside of the range of the use, it can result in the trouble
or the shortened service life. Or an unexpected problem may occur.
* Please put this product in the designated place when you leave work place.
* The ionizer generates ozone(below 0.05ppm). If you sense the smell of ozone when you use
more than two units, ventilate the air.
* Be sure to use regular air hose which endure high level of air pressures.
It can be possible to leak air when you don’t use standardized air hose.
2Check the package contents
▶ Product compositions
The package includes the following products composition.
4Installation and Use
Nozzle
It is the part that
Ionised air is emited.
H/V Abnormal Indicator Light
ALARM LED will be turned on
if high voltage abnormal condition. Operating Indicator Light
Lights up while pulling the trigger
and eliminating the static electricity.
Hook
To hang the product
when you do not use it.
Air Tube Inlet
Air Tube connecting.
(Out dia. Ø6 x Inner dia. Ø4)
Power Inlet
Used to power supply.
Light LED
To check if the dust and
particles are stained or remained.
Light LED Switch
Used to turn On/Off
the light LED.
Trigger
Pull the trigger to
operate the product.
Ion Gun
SIG-30
1ea
▶ How to install
*
Use only the included power supply adapter. Use of other adapters may results
in a fire, an electric shock and static electricity removal troubles.
*
Use an air hose of sufficient durability for high pressure performance.
Air hose of insufficient durability will rupture and leak air.
*
Install the SIG-30 in the below environments.
Adverse environments cause product deterioration and breakdown.
Humidity : 35 ~ 65%RH (No dewing) Temperature : 5 ~ 40˚C
*
Do not pull excessively on the tube. Abusive handling can damage the gun and
internally disconnect the power cable and air hose.
Adapter
SAD-IG-1-001
AC 100~240V, 50/60Hz
DC 24V, 0.75A
2.5m / 1ea
Power Cable
SPC-BL-2-001
AC 220V, 50/60Hz, 1.8m / 1ea
Power Cable
SPC-BL-1-001
AC 100V, 50/60Hz, 1.8m / 1ea
▶ Option
If you require extra functions with the basic accessories we provided, you need to purchase
optional items in below for further assistant.
Discharge Needle
SIE-NZ-1-001
Screw Driver
SDR-NZ-1-001
Never look into high
luminance LED through
your naked eye.
▶ How to use
*
Do not use the SIG-30 for anything other than static elimination or dust removal.
* If noticing anything strange, stop using the SIG-30 immediately.
*
Supply CDA(Clean Dry Air). Improper air quality can lead to SIG-30 deterioration
and work contamination.
*
After cleaning the electrode wire, attach the nozzle. If the SIG-30 is used without
the nozzle, the electrode wire may fly off under the air pressure.
*
Do not pull excessively on the tube. Abusive handling can damage the trigger
and internally disconnect the power cable and air hose.
*
Do not use the damaged hose or cable. Keep the hose and cable away from source of heat.
* Before leaving the workplace, return the product to the specified place.
a. Be sure if air tube correctly connected.
b. Plug the power adapter into a 100V - 240V AC electrical outlet.
c. Power Supply Connector is correctly connected with Ion Gun.
d. Regulate air pressure to 0.1 ~ 0.6MPa from the pressure regulator. (0.4MPa recommended)
e. Pull the trigger to blow ion air from the nozzle.
Blow air towards the statically charged work or dust covered work.
f. Release the Trigger when static elimination and dusting out have been completed.
g. Hang the gun in the specified place from the hook on the gun body.
a. Installation Site
ㅤSelect a location that is suitable for work and near to an air source and 100~240V AC supply.
b. Hose
ㅤ
Use an air hose(Out dia. Ø6[mm] x Inner dia. Ø4[mm]) of sufficient withstand pressure performance.
c. Air
ㅤ
Place your compressed air hose into the main body's Air inlet. Allowable air pressure is 0.1~0.6MPa.
ㅤRemove all impurities with a mist separator(0.3[μm]). Remove all moisture with an air dryer.
ㅤSupply air at a temperature of 0 ~ 40˚C.
ㅤ※ Using compressed air is mandatory for smooth elimination of electrostatic.
Please be sure to use the compressed air.
d. Power Adapter
ㅤUse the power adapter. Using with other specification adapter, it may lead to breakdown.
ㅤThe included adapter is specifically designed for using with the SIG-30.
ㅤDo not use the adapter for any other purposes.
e. Ground
ㅤGround the SIG-30 using the grounding wire.
f. Checks Before Use
ㅤBefore use, check the SIG-30, tube and power adapter for trouble.
ㅤMake sure there is no damage, loose screws, disconnected hosing, loose connectors, etc.

04 05 06
7Specification
※ The appearance and specification of the product may be changed without prior notice for the
improvement of the product.
5Maintenance
Maintenance is an essential item for maintaining its capacity. Please conduct a routine
maintenance according to the below description. The life time of a discharge needle
can be a difference depending on using circumstance. SIG-30 needs a routine maintenance
and cleaning in case of bad circumstance.(high humidity or dust)
Therefore, the discharge needle is recommended to be cleaned regularly.
*
Do not perform any maintenance on the SIG-30 except for the discharge needle.
*
Before cleaning the discharge needle, shut off power and unplug the adapter
from its electrical outlet.
Shut off air supply at the source and disconnect the air hose.
*
Do not wipe the SIG-30 with detergent or solvent. Substances of the sort can
cause cracking and result in electric shock or breakdown.
* Do not wet the SIG-30.
Contact with moisture can result in electric shock or breakdown.
* Do not separate or remodel except for technical engineer.
It can be possible to get an electric shock or break down.
6Dimensions
▶ Ion Gun (SIG-30)
▶ Adapter
<Front> <Side>
<Open> <Close>
▶ Custody
Do not store the SIG-30 in the following places.
Adverse environments can cause product breakdown.
▶ Ion Gun case cleaning
Remove the dirt over the gun with soft and dried cloth.
Never apply with alcohol and/or thinner solvent and detergent.
▶ Discharge needle cleaning
Check and clean the discharge needle every month. The cycle can be extended depending on the environment.
a. Be sure to power off before cleaning the ionizer.
b. Turn a nozzle part counter clockwise to disconnect.
c. Soak the cotton swab with alcohol. (do not use acetone)
d. Put the swab on the discharge needle and wipe it turning the swab right and left.
(take precautions not to apply severe force to the discharge needle.)
e. Replace the damaged discharge needle.
f. After the cleaning, let the alcohol applied to the discharge needle surface evaporate
completely and then operate the SIG-30.
g. Please record the cleaning process as a reference in the file.
• Where exposed to marked vibrations or shocks.
• Where temperature and humidity are outside specified ranges.
• Where dewing occurs.
• Where temperature fluctuates sharply.
• Where there is the possibility of ignition or explosion of flammable solvents, dust, etc.
• Where there is heavy dust or smoke.
• Where possibly wet by water, oil, chemicals, etc.
• Where strong electric or magnetic fields are generated.
▶ The cycle of replacing the electricity removal discharge needle
Check during the discharge needle cleaning and take action.
a. Replace the broken or severely damaged discharge needle.
b.
The discharge needle is very sharp at the edge. Do not phsically(directly) touch the discharge needle.
c.
The general cycle of needle replacement is one year, however, it can vary depending on the
environment of use.
107.5
22.0
27.5
169.0
35.0
150.0
26.3 68.2
49.8
2.5M
Parameter Description / Value Remarks
Input Power
Power Consumption
Current Consumption
Ion-Generation Method
Air Purge Supply Pressure
Operation Circumstance
Ozone(O3) Concentration
Operation Distance
Ion Balance
Main Body Material
Hook Material
Electrode Material
Weight
Alarm Function
Accessory
Warranty
DC 24V
1.8W
75mA
High Frequency AC
0.1 ~ 0.6MPa (0.4MPa Recommendation)
5℃ ~ +40℃(41℉ ~ 104℉), 35% ~ 65% RH
≤0.05ppm
50~ mm
Within ±10V
ABS
Stainless Steel
Tungsten
198g
H/V Abnormal
AC Adapter
1 year
±5%
Lighting LED On
DC 24V
CDA(Clean Dry Air), N2
No dewing
50mm
Non-Hazardous locations
0.3MPa, 150mm
Copyright 2017. SUNJE Hi-Tek Co., Ltd. All Rights Reserved.
Sunje (SHANGHAI) Trading Co.,Ltd.
Room 312, Jiurun Business Building 3rd Floor,No. 298,
Yindu Road, Xuhui District, Shanghai, China 200000
T) +86-21-5433-9761 F) +86-21-5433-9762
Sunje Technology Co., Ltd.
2F, No.6, Lane.102, Sinhe Rd, Sinfong Township,
Hsinchu County, Taiwan 30472
T) +886-3-568-7891 F) +886-3-568-7950
Sunje Japan Co., Ltd.
3-11-16-321 Higashimikuni, Yodogawa-ku, Osaka, Japan
T) +81-6-4866-5202 F) +81-6-6399-9290
Head Office & Factory (Busan)
8 ,Cheonggwang-gil, Ilgwang-Myeon, Gijang-Gun,
Busan, Korea
T) +82-51-720-7500 F) +82-51-720-7501
Southern Sales Office (Chilgok)
35-2, Seojungni 3-gil, Seokjeok-eup, Chilgok-gun,
Gyeongsangbuk-do, Korea
T) +82-54-476-9033 F) +82-54-476-9034
Central Sales Office (Hwaseong)
3F, Ilshin B/D, 4, Namnyeoul 2-gil, Hwaseong-si,
Gyeonggi-do, Korea
T) +82-31-203-9034 F) +82-31-202-9034
Customer Center +82-70-7714-9033
Sales Contact +82-31-203-9034
www.sunstat.com
Table of contents