Note:
flash 1 - 0.25s light / 3.75s off
flash 2 - 0.5s light / 0.5s off
flash 3 - 0.5s light / 1.5s off
Charging Battery Level Indicators Instructions
LED Indicators Instructions
2.2.2 LED Indicator Definition
RUN ALM
L8 L7 L6 L5 L4 L3 L2 L1
OFF OFF OFF OFF OFF OFF OFF OFF All OFF
Flash 1 OFF Indicates Standby
Normal Light OFF The highest capacity indicator LED
flashes(flash 2),others lighting
Full Charged Light OFF Light Light Light Light Light Light Turn to standby status when charger off
Protection OFF Light OFF OFF OFF OFF OFF OFF Stop charging
Normal Flash 3 OFF
UVP OFF OFF OFF OFF OFF OFF OFF OFF Stop charging
Protection OFF Light OFF OFF OFF OFF OFF OFF Stop discharge
OFF Light OFF OFF OFF OFF OFF OFF Stop charging and Discharge
Battery Leve l Indicator
Des criptionsStatus
Fault
Discharge
According to the battery level
Shut down
Standby According to the battery level
Charging
According to the battery level
L8 L7 L6 L5 L4 L3 L2 L1
017% OFF OFF OFF OFF OFF Flash 2
18 33% OFF OFF OFF OFF Flash 2 Light
34 50% OFF OFF OFF Flash 2 Light Light
51 66% OFF OFF Flash 2 Light Light Light
67 83% OFF Flash 2 Light Light Light Light
84 100% Flash 2 Light Light Light Light Light
Full Charge d Light Light Light Light Light Light
Charging
Light OFF
Battery Level
%
Status
Battery Level Indicator
PIN
Pin 1、Pin 8
Pin 2、Pin 7
Pin 3
Pin 4
Pin 5
Pin 6
Definition
RS485-B ( to PCS, reserved )
RS485-A ( to PCS, reserved )
NC
CANH ( to PCS )
CANL ( to PCS )
GND
2.2.4 RS232 Port
PIN
Pin 1、Pin 8
Pin 2、Pin 7
Pin 3、Pin 6
Pin 4、Pin 5
Definition
GND
RS232_TX
RS232_RX
NC
RS232 Communication Terminal (RJ45 port) follow RS232 protocol,
for manufacturer or professional engineer to debug or service.
2. Switch OFF
Press start button of Master PACK more than 3s and then release the button, the master
pack will shut down after all slave packs shut down(Sleep mode) .
For single SUN-BATT-15.97, switch OFF rocker switch (near positive/negative connector).
For multiple SUN-BATT-15.97 in parallel, switch OFF rocker switch ofall slave batteries
first.Then switch OFF rocker switch ofMASTER battery.
Discharging Battery Level Indicators Instructions
2.2.3 CAN / RS485 Port
L8 L7 L6 L5 L4 L3 L2 L1
0 17% OFF OFF OFF OFF OFF Light
18 33% OFF OFF OFF OFF Light Light
34 50% OFF OFF OFF Light Light Light
51 66% OFF OFF Light Light Light Light
67 83% OFF Light Light Light Light Light
84 100% Light Light Light Light Light Light
Status Discharge
Battery Level Indicator
Battery Level
%Flash 3 OFF
CAN / RS485 Communication Terminal (RJ45 port), connect to inverter,
follow CAN / RS485 protocol.
05 06