Sunwave SBT - 30S User manual

DIGITAL ACTIVE INFRARED SENSOR
SBT - 40S
SBT - 60S
SBT - 80S
SBT-100S
SBT - 30S
38mm
φ~50mm
φ
INSTRUCTION MANUAL
SUGGESTIONS FOR INSTALLATION 1
2
1
PARTS DESCRIPTION
Connection
Terminal
① LED
Vertical
Adjustment
Screw
③ Obscuration Time
Adjustment
(Only for Receiver)
② Monitor Jack
(Only for Receiver)
Tamper
Viewfinder
Horizontal Angle
Adjustment Dial
Cover Lock
Screw
LENS
MAIN BODY
COVER
Wire Hole
RECEIVER
GOOD LEVEL ALAR M
TRANSMITTER
POWE R
SUGGESTIONS FOR INSTALLATION 2
3
0.7
~
1.0m
14mm 33mm
33mm
Spread of
Beam
Model
SBT-30S
SBT-100S
SBT-80S
30m
80m
100m 3.0m
2.4m
0.9m
SBT-60S
60m 1.8m
SBT-40S
40m 1.2m
Protection
Distance
Note that here the protection distances
refers to the sheet below.
Protection Distance
Spread of Beam
Height of installation and
protection distance
4INSTALLATION
1. Loosen screw holding cover and
remove the cover.
3. Break knock-out and pull wire
through.
4. Attach the unit to the wall. 5. Connect wires to the terminal.
Wiring distance
WALL MOUNT
TERMINAL CONFIGURATION
1234567
POWER ALARM
RECEIVER
TAMPER
1234567
TRANSMITTER
POWER FREE TAMPER
knock-out
SBT-30S SBT-40S SBT-60S SBT-80/100S
24V 12V 24V 12V 24V 12V 24V
2400m
4400m
7000m
10000m
280m
1120m
780m
500m
2φ
2φ
2φ
2φ
12V
0.3mm ( 0.6)
f
0.5mm ( 0.8)
f
0.75mm ( 1.0)
f
1.25mm ( 1.2)
f
2300m
4200m
6700m
9570m1074m
747m
477m
2100m
3800m
6100m
8700m
250m
980m
680m
430m
270m 1600m
3000m
4900m
7000m
190m
784m
546m
350m
Model
Voltage
Wire
diameter
Each bracket to be reversely attached.
1. Pull the wire through the
wire hole of the pole.
2. Attach the bracket to the pole with the pole holder.
Bracket Pole holder Pole cover
POLE MOUNT
Pole mount back-to-back
Attach the mounting pattern
guide holes.
2.
Make the optimum optical adjustment
6.
① LED
●GOOD ( Green ) ●POWER ( Green )
On when optically aligned
●LEVEL ( Red )
●ALARM
Intensity varies with signal
Alarm indication lamp
Off when optically not aligned
② Monitor jack: Should be used for making the optimum optical axis adjustment
③ Obscuration time adjustment: To be used for setting the obscuration time
( Refer to ' how to use the monitor jack' )
( Refer to ' adjustment of obscuration time ' )
Ensure the sensors line of sight is
free from any false alarm sources
such as bushes, trees, etc. ( Pay
attention to these as they may
change seasonally.)
Ensure the sensors are
firm fixing.
mounted on a stable and
Ensure strong sunlight or car
recommended.)
headlights do not shine directly
from the optical axis is not
on to the receiver. (Within ±2°
Direction of installation
Horizontally 180°
Vertically 20°
Because angle of reflection mirror is adjustable
±
unit can be installed in various directions.
in 90°horizontally and 10°vertically, the
±
paper to the wall, mark the
installation holes, and make
operation before replacing covers.
as per section 5 and confirm system
Transmitter
Receiver
Transmitter
Receiver
Receiver
Transmitter
In case of jump phenomenon, as shown ×
of transmitter and receiver to the following
section in the above, change the disposition
manner shown section.◎
Receiver
Transmitter

10cm
2. Look through the viewfinder as shown below.
Viewfinder
NOTE: After completion of optical adjustment, ensure
Monitor Jack
1. Insert the meter pins into the monitor jack.
(Pay attention to the polarity because of DC voltage)
Vertical adjustment
to raise
(loosen)
to lower
(tighten)
15
4
3
2
ADJUSTMENT OF OBSCURATION
Obscuration time control
CONFIRMATION OF OPERATION
After completion of the installation, confirm correct operation by suitable walk test. Refer to the following LED
indications during the walk test. Confirm tamper operation prior to replacing covers. Confirm system operation
with covers replaced.
Transmitter
Receiver
Conditions
Transmitting
Watching
Alarm
Indication
Green LED is on
Alarm indicator is off
Alarm indicator is on
NOTE: Conduct a Walk Test at least once a year
OUTLINE DIMENSION
9
TROUBLE SHOOTING GUIDE SPECIFICATION
Model SBT-30S SBT-40S SBT-60S SBT-80S SBT-100S
Protection range(outdoor)
Distance allowance
5-30m 30-40m 40-60m 60-80m 80-100m
350m 450m 650m 900m 1100m
Infrared beam
Detection system
Light source
Response time
Alarm output
Power required
Power consumption
Temperature range
Tamper output
Optical axis horizontal adjust
Optical axis vertical adjust
Collimator
Measure for moisture/frost
Other additional function
Place for installation
Weight
2 beams
2 beams simultaneous cut-off detection
Infrared LED
50-700 msec
Relay contact, form 'C' contact rating 30V AC, DC 0.5A Max.
DC 10.5-28V
40mA max
DC12-28V
45mA max
DC12-28V
55mA max
DC12-28V
65mA max
DC12-28V
65mA max
DC12-28V
-25℃~+55℃
Normally closed voltage free contacts 30V DC, 0.5 A Max.
±90°
±10°
Finder ( peep window )
Slit type cover, heater option
Sensitivity monitoring output terminal. Ok monitoring
Indoor or Outdoor
600g ( Transmitter and Receiver )
82
60
146
171
2- 4.0mm
2- 5.0mm
38~50mm
Pole 77
Caution: Obscuration time settings exceeding 70msec (exceeding a setting of 1) do
Set the obscuration time of the receiver by adjusting the obscuration time control
conditions where there are a lot of birds or wind blown material.
5 ADJUSTMENT OF OPTICAL AXIS
It is important to ensure correct optical alignment between the
transmitter and receiver for proper operation.
HOW TO USE THE MONITOR JACK
The best adjustment of optical axis can be done by reading the
output voltage of the monitor jack.
7
10
W.97.0067
6
8
Turn on the power supply after uninstallation.
1. Adjust the angle of the lens via the Horizontal angle
3.
Possible cause A Remedy
Indication lamp of Transmitter
does not light. Improper voltage of power supply Check power supply and wiring
Power supply indication Lamp
of Receiver does not light. Improper voltage of power supply Check power supply and wiring
Alarm indication lamp does not
light even when the beams are
intercepted.
②
Remove the reflecting object or
Check two beams to intercept
at the same time.
Adjust obscuration time setting
to be shorter.
Although alarm LED lights
①
Melted bridge on the signal
Check the wiring.
It needs to be repaired.
Alarm LED on the Receiver
does not turn off.
Inadequate optical axis.
Shading objects between the
of the Transmitter and/or Receiver.
Readjust the optical axis.
Remove the shading objects.
Clean optics with soft cloth.
Bad wiring connection.
Change of supply voltage.
Shading objects moving by wind
Unstable installation of the sensor
unit.
Incomplete optical axis adjustment.
Birds and other large flying objects
intercept the beam.
Check the wiring connection.
Check the voltage (for stabilized
supply voltage.)
Remove the shading objects or
Fix steadily.
Readjust the optical axis.
Readjust the obscuration time
to be longer or reposition.
①Infrared beam from Transmitter is
sent into the Receiver.
Shorter obscuration t ime t han that
③
Q Symptom
Intermittent alarm.
Place the viewfinder on either right or left
hand side of the lens whichever makes
easier viewing. the sensor can be seen in the center of the Viewfinder.
adjustment and the Vertical adjustment screw so that
and Receiver. Confirm after adjustment that the green
This adjustment is carried out on both the Transmitter
GOOD LED is on, otherwise alignment should be
readjusted. The red LEVEL LED lamp will be brighter
dependent on higher signal levels.
that both filters on the receiver are replaced
to their original position behind the mirrors.
NOTE: If the sensors are too close together then the signal level saturates and
2. a) Adjust the horizontal adjustment until the output is at a maximum.
b) Adjust the vertical adjustment screw to obtain best signal.
(Do not interrupt beam by hands during the adjustment)
3. The following minimum voltages should be obtained to ensure best performance.
2.3V for all of the SBT-XXS series. If this is not obtained then the transmitter and
receiver should be re-aligned.
the IR beam may be shut-down. This is normal and will only be achieved
during bench testing. Signal levels are restored under normal operation
distances.
Scale 1
fast running at full
Scale 2 Scale 3 Scale 4
walking with quick normal walking
slow action
speed(6.9m/s) steps(1.2m/s) (0.7m/s)
(0.3~0.5m/s)
to the required setting according to the sketch beside. The obscuration time should
be set lower to detect faster moving targets, however care should be taken to note
the environmental conditions as the obscuration time should be set higher to ignore
not comply with the requirements in UL639, Instrusion Detection Units.
intercepted, alarm does
when the beams are
not ring.
reflected on another object and
Two beams are not intercepted at
set on the obscuration control.
the same time.
Broken wires or short on the
(Wrong current on the signal wires)
connection
②
signal wires.
Transmitter and the Receiver.
Dirty cover or dirty reflection mirror
②
③
between the Transitter and the
Receiver.
①
②
③
④
⑤
⑥
①
②
①
①
③
②
②
③
①
②
③
④
⑤
⑥
①
change the place for installation
and the optical axis direction.
change the place for installation.
SHENZHEN SUNWAVE ELECTRONICS CO., LTD.
http://www.sunwave.cc
CHINA
TEL: +86-755-8998-3101 FAX: +86-755-8998-3102
No.21 Plant, Da Wei Industrial Zone, Huang Ge
Heng Gang Town, Shenzhen
Keng,
This manual suits for next models
4
Table of contents
Popular Security System manuals by other brands

Digital Monitoring Products
Digital Monitoring Products COMMAND PROCESSOR XR500N operating instructions

Autronica
Autronica AutroSafe Maritime Gas Detection Operating instructions and system description

mcmurdo
mcmurdo Fastfind Personar EPIRB owner's manual

Uniden
Uniden G37 Series owner's manual

Cooper Wheelock
Cooper Wheelock RSSPA-24MCC-NW specification

dallmeier
dallmeier PANOMERA S4 Commissioning