Sunx FD-F8Y User manual

Please refer to the instruction manual enclosed with the fiber sensor amplifier.
SPECIFICATIONS
1
Notes: 1)
2)
3)
4)
Unclear liquid may not be sensed stably.
1,000mm from the amplifier insertion end is the cutting range.
Liquid being detected should also be kept within the rated ambient
temperature range.
The ambient temperature and pressure under which these devices are used
are set separately.
For usage with both of these at or near the maximum permissible value,
please contact our office.
FX-CT2 (Fiber cutter): 1 pc.
FX-AT3 (Ǿ2.2mm fiber attachment for FX-301/302/303/311 series): 1pc.
Accessory
-49 to +490kPa
Ambient pressure
(Note 4)
Allowable
bending radius
Tube: R40mm or more (Do not bend 26mm length from the tip)
Fiber cable: R15mm or more
2m free-cut [Do not cut the tube (Note 2)]Fiber cable length
Tube: Fluorine resin, Fiber sheath: PolypropyleneMaterial
35 to 85% RH, Storage: 35 to 85% RHAmbient humidity
-40 to +125(No dew condensation or icing allowed), Storage: -40 to +125
Ambient temperature
(Note 3) (Note 4)
0.5mm or less (with water)Repeatability
Liquid (Note 1)
FX-301(P), FX-302(P), FX-303(P), FX-311(P), FX-D1(P), FX-A1(P), FX-M1(P)
red LED type of FX-7 series, long sensing range type of FX-10 series
FD-F8Y
Refelctive
Applicable fiber
amplifiers
Sensing object
Type
Item
Model No.
CAUTIONS
2
٨
٨
٨
٨
٨
٨
٨
٨
Take care that unclear liquid may not be sensed stably.
Take care that the tube may stretch by maximum 2% of the total length if it is used
at a high temperature.
Bending radius of the fiber cable must be R15mm or more (tube: R40mm or
more). However, do not bend 26mm length from the tip.
If the bending radius is smaller than the specified value, the sensing performance
may deteriorate.
Do not use the fiber at places having intense vibrations, as this can cause mal-
function.
Keep the fiber head surface intact. If it is scratched or spoiled, the detectability will
deteriorate.
Ensure that any strong extraneous light is not incident on the receiving face of the
fiber head.
Do not apply excessive tensile force to the fiber cable.
Take care that the sensor is not directly exposed to fluorescent light from a rapid-
starter lamp or a high frequency lighting device, as it may affect the sensing per-
formance.
SENSITIVITY SETTING
5
Do not move or bend the fiber cable after the sensitivity setting. Detection may
become unstable.
Thank you very much for using SUNX products. Please read this Instruction Manual
carefully and thoroughly for the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
INSTRUCTION MANUAL
FD-F8Y
Liquid Level Detection Fiber
MOUNTING
3
٨Use a commercially available fluorine resin joint, etc.,
to install FD-F8Y.
Fluorine resin joint
CUTTING FIBER CABLE
4
٨
٨
٨
The fiber cables should be cut off at the ends with the fiber cutter FX-CT2
(accessory) before insertion into the fiber amplifier.
For the usage of the fiber cutter (FX-CT2), refer to the instruction manual
enclosed with this product other than this instruction manual.
Do not scratch the fiber sheath while cutting the fluorine resin tube.
Protective tube Fiber cable
10
mm
Possible
cutting range
٨This is the method of setting the threshold value by teaching only the water absent
condition (not immersed condition).
<Limit teaching>
٨
٨
٨
Adjust the sensitivity, observing the op-
eration indicator (orange).
However, since the condition for lighting
up of the indicator depends on the com-
bination of the sensing condition and
selected operation for L/D-ON, verify it
from the table on the right.
The sensitivity adjuster is a 12-turn po-
tentiometer. The maximum sensitivity is
obtained by turning it fully clockwise.
The pointer shows the present sensitivity level.
When using the FX-311(P)
MODE
L-ON (ON when not immersed)
L-ON (ON when not immersed)
D-ON (ON when immersed)
D-ON (ON when immersed)
Operation
indicator
Immersed
Not
immersed
Sensing
condition
: Lights off
: Lights up,
Note:
The approx. 15% amount of shift is the initial value. The amount of shift can be
changed in the PRO mode from approx. 5 to 80% (5% step). Refer to
'SUNX fiber sensor homepage (http://www.fiber-sensor.com)' for the setting
method.
When using the FX-301(P) or the FX-302(P), FX-303(P)
٨This is the method of setting the threshold value by teaching two levels,
corresponding to the immersed and not immersed conditions. Normally, setting is
done by this method.
<2-level teaching>
Ԟ
ԝ
Ԝ
ԛ
Ԛ
ԙ
Ԙ
The incident light intensity appears in the digital dispaly and the setting is
complete.
The threshold value is displayed.
If the teaching is accepted, the read incident light intensity blinks in the digital
display and the threshold value is set at the mid-value between the incident
light intensities in the immersed and the not immersed conditions. After this,
the judgment on the stability of sensing is displayed.
In case stable sensing is possible: ' ' is displayed. Stability indicator
(green) blinks.
In case stable sensing is not possible: ' ' is displayed. Stability indicator
(green) is off.
MODE indicator / TEACH (yellow) blinks.
Press jog switch in the fiber not immersed con-
dition.
Press jog switch in the fiber immersed condition.
If the teaching is accepted, the read incident
light intensity blinks in the digital display.
Step Display Description
Press
Press
The fibers are mounted in the tank.
Press MODE key to light up MODE indicator /
TEACH (yellow).
Press
' ' blinks in the digital display.
Step Display Description
Turn to '-' side
Press
Ԙ
The fibers are mounted in the tank.
Press MODE key to light up MODE indicator /
TEACH (yellow).
Press
ԛ
Ԛ
MODE indicator / TEACH (yellow) blinks.
Turn jog switch to the '-' side.
ԙ
Press jog switch in the not immersed condition.
If the teaching is accepted, the read incident
light intensity blinks in the digital display.
ԟ
Ԟ
ԝ
Ԝ
After this, the judgment on whether the setting shift amount can be shifted or
not is displayed.
In case shifting is possible: ' ' is displayed.
In case shifting is not possible: ' ' is displayed.
If jog switch is turned to the '-' side, ' ' scrolls (twice)
the digital display from left to right, and the threshold level is
shifted to a value approx. 15% lower (higher sensitivity) than
that set at ԙ. (Note)
The incident light intensity appears in the digital dispaly and the setting is
complete.
The threshold value is displayed.
' ' blinks in the digital display.
15%
0
100%
High
Low
Turn to '-' side
ON
OFF
Threshold
value
Incident light intensity
with fiber not immersed
Threshold value

٨This is the method of setting the threshold value by teaching only the water absent
condition (not immersed condition).
<Limit teaching>
٨This product incorporates an 'assist function', which helps to easily search the
optimum sensitivity position by blinking of the pointer.
In order to make 'assist function' effective, switch the operation selection switch in the
order L-ON (not immersed ON) ψD-ON (immersed ON) ψL-ON (not immersed ON).
<Assist function>
Notes: 1)
2)
'Assist function' turns off automatically once the sensitivity adjustment has
been completed.
In case 'assist function' is not to be used, set the operation selection switch
to D-ON (immersed ON) and wait for 2 sec., or more, to make 'assist
function' ineffective.
When using the FX-A1(P)
٨
This is the method of setting the sensitivity by teaching two levels, corresponding to
the immersed and not immersed conditions. Normally, setting is done by this method.
<2-level teaching>
Notes: 1)
2)
3)
If the jog switch is pressed continuously 3 sec., or more, full auto-teaching is done. In
case of FD-F8Y, correct threshold value setting cannot be done in full auto-teaching.
If the mode selection switch is changed to 'RUN' when ' ' is being displayed
on the LCD display, the incident light intensity taught at Step Ԝis not recorded.
When the mode selection switch is changed from 'SET' to 'RUN' or from
'MODE' to 'RUN', the set threshold value or the contents of each mode set-
ting are stored in an EEPROM. However, since the EEPROM has a lifetime,
the threshold value setting cannot be done for more than 100,000 times.
Notes: 1)
2)
3)
4)
When 'assist function' is not used, the pointer does not blink.
When 'assist function' is not used, the middle point of and is regarded
as the optimum sensitivity point.
In order to protect the mechanism, the sensitivity adjuster idles when over
turned, which may result in a backlash of 1 to 2 divisions.
Depending upon the sensing conditions, stable sensing may be possible at a
position which is slightly shifted from the optimum sensitivity point.
When using the FX-D1(P)
Notes: 1)
2)
3)
If the jog switch is pressed continuously 3 sec., or more, full auto-teaching is
done. In case of FD-F8Y, correct threshold value setting cannot be done in
full auto-teaching.
If the mode selection switch is changed to 'RUN' when ' ' is being displayed
on the LCD display, the incident light intensity taught at Step Ԝis not recorded.
When the mode selection switch is changed from 'SET' to 'RUN' or from
'MODE' to 'RUN', the set threshold value or the contents of each mode setting
are stored in an EEPROM. However, since the EEPROM has a lifetime, the
threshold value setting cannot be done for more than 100,000 times.
٨
This is the method of setting the threshold value by teaching two levels, corresponding to
the immersed and not immersed conditions. Normally, setting is done by this method.
<2-level teaching>
The fibers are mounted in the tank.
Set the mode selection switch to either 'RUN' or
'MODE'.
Set to either sensing output 1 or sensing output 2 by
turning the jog switch to the '+' or the '-' side.
Set the mode selection switch to 'SET'. The present
threshold value is displayed.
Ԟ
ԟ
ԝ
Ԝ
ԛ
Ԛ
ԙ
Ԙ
The jog switch is pressed in the fiber not
immersed condition and released.
Press the jog switch in the fiber immersed
condition and release it within 3 sec. (Note 1)
Step Display Description
Press
Press
SET MODE
RUN
Set the mode selection switch to 'RUN'.
The threshold value does not change even if the jog
switch is operated.
Ԡ
SET MODE
RUN
SET MODE
RUN
1
2
Sensing
output 1
Sensing
output 2
1
2Tu r n
Incident light
intensity dispaly
If teaching is accepted, the read incident light intensity is displayed for 0.5 sec.
approx., and the threshold value is set to the middle value of the incident light
intensity levels in the fiber immersed and fiber not immersed conditions. After
that, the judgment on the stability of sensing is displayed for 2.5 sec. approx.
In case stable sensing is possible: ' ' is displayed.
In case stable sensing is not possible: ' ' is displayed.
After this, the threshold value is displayed.
Incident light
intensity dispaly
Incident light
intensity dispaly
or
If teaching is accepted, the read incident light intensity is displayed for 0.5
sec. approx. Subsequently, ' ' is displayed on the LCD display. (Note 2)
Operation
Ԝ
ԛ
Ԛ
ԙ
Ԙ
Select either L-ON (not immersed ON) or D-ON (immersed ON) according to your application.
Turn the sensitivity adjuster fully counter-
clockwise.
(Minimum sensitivity)
ڎ
Make sure that the opera-
tion selection switch is set
to L-ON (not immersed ON).
In case 'assist function' is to
be used, switch the operation
selection switch in the order
of L-ON ψD-ON ψL-ON.
Step Sensitivity
indicator
Sensing method
Fiber immersed
Fiber not immersed
0
MAX
0
MAX
ON
0
MAX
OFF
ON
Optimum point
0
MAX
In the fiber not immersed condition, slowly
turn the adjuster clockwise and find the point
where the sensor is switched ON.
The pointer blinks once at the point
. (Note 1)
In the fiber immersed condition, slowly turn
the adjuster further clockwise until the sensor
goes into the ON state again. Once it is
switched on, turn the adjuster counterclock-
wise a little and find the point where it is
switched OFF. The pointer blinks twice at the
point . (Note 1)
If the sensor does not go into the ON state,
MAX is the point .
Turn the adjuster towards the point from
the point slowly. The pointer starts blinking
when it approaches the optimum sensitivity
point and blinks faster at the optimum sensi-
tivity point for 3 sec. This point is the optimum
sensitivity point. (Note 2)
Notes: 1)
2)
3)
If the jog switch is pressed continuously 3 sec., or more, full auto-teaching is done.
In case of FD-F8Y, correct sensitivity setting cannot be done in full auto-teaching.
Also, if the mode selection switch is changed to 'RUN' while level indicators '4'
and '5' are blinking, the incident light intensity taught at Step Ԛis not recorded.
When the mode selection switch is set to 'SET' or 'MODE', the sensor is more
susceptible to extraneous light. Hence, when sensing a liquid, ensure to set the
mode selection switch to 'RUN'.
When the mode selection switch is changed from 'SET' to 'RUN' or from
'MODE' to 'RUN', the set sensitivity or the contents of each mode setting are
stored in an EEPROM. However, since the EEPROM has a lifetime, the sen-
sitivity setting cannot be done for more than 100,000 times.
The fibers are mounted in the tank.
ԙ
Ԙ
Step Level indicators Description
Set the mode selection switch to 'SET'. The
present sensitivity level is displayed.
SET MODE
RUN
ԝ
Ԛ
Ԝ
ԛ
SET MODE
RUN
Set the mode selection switch to 'RUN'. (Note 2)
The sensitivity level does not change even if
the jog switch is operated.
The jog switch is pressed in the fiber not
immersed condition
The stability indicator (green) lights up and the sensitivity level is set
at the middle value of the incident light intensity levels in the fiber im-
mersed and fiber not immersed conditions.
The sensitivity level is then displayed on
the level indicators.
Hundreds position: lights up continuously
Tens position: blinks
Units position: not shown
(e.g.) The level indicators in the figure on
the left show that the sensitivity level
is in the range 720 to 729.
Press the jog switch in the fiber immersed condition. The level
indicators '3' and '6' blink.
Release the jog switch within 3 sec. The
level indicators '4' and '5' blink and the
incident light intensity in the fiber immersed
condition is read. (Note 1)
Press
Press
Sensitivity
level
Fiber
immersed
Fiber not
immersed
High
Low
Incident light
intensity
Step Display Description
SET MODE
RUN
SET MODE
RUN
SET MODE
RUN
The fibers are mounted in the tank.
Set the mode selection switch to either 'RUN' or
'MODE'.
Set to either sensing output 1 or sensing output 2 by
turning the jog switch to the '+' or the '-' side.
Set the mode selection switch to 'SET'. The present
threshold value is displayed.
Ԟ
ԟ
ԝ
Ԝ
ԛ
Ԛ
ԙ
Ԙ
Press the jog switch in the fiber not immersed
condition and release it within 3 sec. (Note 1) Press
Set the mode selection switch to 'RUN'.
The threshold value does not change even if the jog
switch is operated.
Ԡ
1
2
Sensing
output 1
Sensing
output 2
1
2Tu r n
Incident light
intensity dispaly
' ' is displayed on the LCD display.
After this, the threshold value is displayed.
Incident light
intensity dispaly
If teaching is accepted, the read incident light intensity is displayed for 0.5
sec. approx. Subsequently, ' ' is displayed on the LCD display. (Note 2)
Turn the jog switch to the '+' side.
The threshold value is shifted to a value appox. 15% lower
(higher sensitivity) than that set at step Ԝ.
㪫㫌㫉㫅㩷㫋㫆㩷㩾㪂㩾㩷㫊㫀㪻㪼
15%
0
100%
High
Low
Turn to '-' side
ON
OFF
Threshold
value
Incident light intensity
with fiber not immersed
Threshold value

Note: The sensitivity setting can be carried out even if stable sensing is not possible.
٨
٨
In case output chatter is caused by a liquid drop on the fiber head:
FX-301(P), FX-302(P), FX-303(P), FX-D1(P), FX-A1(P):
Use the limit teaching, or the timer function.
Red LED type of FX-7 series:
Use the sensitivity shift function or the timer function (excluding FX-75).
FX-311(P), FX-M1(P), long sensing range type of FX-10 series:
Turn the sensitivity adjuster further clockwise to raise the sensitivity level, or use
the timer function.
In case the tank bottom, etc., gets sensed:
Readjust the sensitivity after setting at the actual depth at which detection is to be
done.
Troubleshooting
Ԟ
ԝ
ON when not
immersed
The fibers are mounted in the tank.
Ԛ
ԙ
Ԙ
Ԝ
ԛ
ON when
immersed
Sensing condition
Step Description
Set the mode selection switch to 'SET'.
Press the ON button.
When the sensor accepts the ON condition, the
stability indicator (green) blinks.
The stability indicator blinks twice if the difference between the
ON level and the OFF level is sufficient enougt to detect the
liquid level stably. (Note)
The stability indicator blinks continuously if the difference is so
small that stable detection of the liquid level is not possible. (Note)
Press the OFF button.
Set the mode selection switch to 'RUN'.
Then, the set sensitivity is registered. Even if the
buttons are pressed by mistake in 'RUN' mode,
the registered sensitivity stays unchanged.
RUN
SIF
SET
RUN
SIF
SET
٨This is the method of setting the sensitivity by teaching only the water absent
condition (not immersed condition).
<Limit teaching>
Notes: 1)
2)
3)
If the jog switch is pressed continuously 3 sec., or more, full auto-teaching is
done. In case of FD-F8Y, correct sensitivity setting cannot be done in full
auto-teaching.
Also, if the mode selection switch is changed to 'RUN' while level indicators
'4' and '5' are blinking, the incident light intensity taught at Step Ԛis not re-
corded.
When the mode selection switch is set to 'SET' or 'MODE', the sensor is
more susceptible to extraneous light. Hence, when sensing a liquid, ensure
to set the mode selection switch to 'RUN'.
When the mode selection switch is changed from 'SET' to 'RUN' or from
'MODE' to 'RUN', the set sensitivity or the contents of each mode setting are
stored in an EEPROM. However, since the EEPROM has a lifetime, the sen-
sitivity setting cannot be done for more than 100,000 times.
Step Level indicators Description
SET MODE
RUN
SET MODE
RUN
Turn the jog switch to the '+' side.
The sensitivity is increased by 15% appox. respect to
that set at step Ԛ.
The fibers are mounted in the tank.
Ԛ
ԙ
Ԙ
Set the mode selection switch to 'SET'. The
present sensitivity is displayed.
Ԝ
ԛ
Set the mode selection switch to 'RUN'. (Note 2)
The sensitivity level does not change even if
the jog switch is operated.
(e.g.) The level indicators in the figure on the left show that the
sensitivity level is in the range 720 to 729.
Press the jog switch in the fiber not immersed condition. The level in-
dicators '3' and '6' blink.
Release the jog switch within 3 sec. The lev-
el indicators '4' and '5' blink and the incident
light intensity in the fiber not immersed con-
dition is read. (Note 1)
Press
㪫㫌㫉㫅㩷㫋㫆㩷㩾㪂㩾㩷㫊㫀㪻㪼
When using the red LED type of FX-7 series
Notes: 1)
2)
In order to protect the mechanism, the sensitivity adjuster idles when over
turned, which may result in a backlash of 1 to 2 divisions.
Depending upon the sensing conditions, stable sensing may be possible at
a position which is slightly shifted from the optimum sensitivity point.
٨
٨
٨
Adjust the sensitivity, observing the op-
eration indicator (orange).
However, since the condition for light-
ing up of the indicator depends on the
combination of the sensing condition
and selected MODE for L/D-ON, verify
it from the table on the right.
The sensitivity adjuster is a 12-turn po-
tentiometer. The maximum sensitivity
is obtained by turning it fully clockwise.
The sensitivity level indicator shows the present sensitivity level.
When using the FX-M1(P)
MODE
L-ON (ON when not immersed)
L-ON (ON when not immersed)
D-ON (ON when immersed)
D-ON (ON when immersed)
Operation
indicator
Immersed
Not
immersed
Sensing
condition
: Lights off
: Lights up,
Turn the sensitivity adjuster fully counterclock-
wise.
(Minimum sensitivity)
ڎMake sure that the
operation selection
switch is set to L-ON
(not immersed ON).
MAX
ON
MAX
OFF
ON
MAX
Operation
Ԝ
ԛ
Ԛ
ԙ
Ԙ
Select the mode either L-ON (not immersed ON) or D-ON (immersed ON) according to your application.
Step
Sensitivity
level indicator
Sensing method
MAX
Optimum
point
In the fiber not immersed condition, slowly turn
the adjuster clockwise and find the point
where the sensor is switched ON.
In the fiber immersed condition, slowly turn the
adjuster further clockwise until the sensor goes
into the ON state again. Once it is switched on,
turn the adjuster counterclockwise a little and find
the point where it is switched OFF.
If the sensor does not go into the ON state,
MAX is the point .
Set the adjuster at the center of points and .
This is regarded as the optimum sensitivity point.
Fiber not immersed
Fiber immersed
Notes: 1)
2)
In order to protect the mechanism, the sensitivity adjuster idles when over
turned, which may result in a backlash of 1 to 2 divisions.
Depending upon the sensing conditions, stable sensing may be possible at
a position which is slightly shifted from the optimum sensitivity point.
٨
٨
٨
Adjust the sensitivity, observing the op-
eration indicator (orange).
However, since the condition for light-
ing up of the indicator depends on the
combination of the sensing condition
and selected MODE for L/D-ON, verify
it from the table on the right.
The sensitivity adjuster is a 8-turn po-
tentiometer. The maximum sensitivity
is obtained by turning it fully clockwise.
The sensitivity level indicator shows the present sensitivity level.
When using the long sensing range type of FX-10 series
MODE
L-ON (ON when not immersed)
L-ON (ON when not immersed)
D-ON (ON when immersed)
D-ON (ON when immersed)
Operation
indicator
Immersed
Not
immersed
Sensing
condition
: Lights off
: Lights up,
Select the mode either L-ON (not immersed ON) or D-ON (immersed ON) according to your application.
MAX
MAX
ON
OFF
ON
MAX
Turn the sensitivity adjuster fully counterclock-
wise.
(Minimum sensitivity)
ڎMake sure that the
operation selection
switch is set to L-ON
(not immersed ON).
Operation
Ԝ
ԛ
Ԛ
ԙ
Ԙ
Step
Sensitivity
level indicator
Sensing method
MAX
Optimum
point
In the fiber not immersed condition, slowly turn
the adjuster clockwise and find the point
where the sensor is switched ON.
In the fiber immersed condition, slowly turn the
adjuster further clockwise until the sensor goes
into the ON state again. Once it is switched on,
turn the adjuster counterclockwise a little and find
the point where it is switched OFF.
If the sensor does not go into the ON state,
MAX is the point .
Set the adjuster at the center of points and .
This is regarded as the optimum sensitivity point.
Fiber not immersed
Fiber immersed
PRINTED IN JAPAN
Head Office
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-(0)568-33-7211 FAX: +81-(0)568-33-2631
Overseas Sales Dept.
Phone: +81-(0)568-33-7861 FAX: +81-(0)568-33-8591
http://www.sunx.co.jp/
SUNX Limited
15%
0
OFF
ON
Turn to '+' side
Sensitivity leval
100%
High
Low
Sensitivity
level
Sensitivity level with
fiber not immersed
Other Sunx Measuring Instrument manuals