SuperiorFireplaces.us.com 126839-01D4
SAFETY Continued
2.Do not place propane/LP supply tank(s) inside
anystructure.Locatepropane/LPsupplytank(s)
outdoors (propane/LP units only).
3.To prevent performance problems, the use of a
propane/LP tank of less than 100 lbs. capacity
is not recommended (propane/LP units only).
4.If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions
• if you cannot reach your gas supplier, call the
fire department
5.This heater shall not be installed in a bedroom
or bathroom.
6.WARNING: Before installing in a solid
fuel-burning fireplace, the chimney flue
and firebox must be cleaned of soot, creo-
sote, ashes and loose paint by a qualified
chimney cleaner. Creosote will ignite if highly
heated. A dirty chimney flue may create and
distribute soot within the house. Inspect chim-
ney flue for damage. If damaged, repair flue
and firebox before operating appliance.
7.Do not burn solid-fuel in a fireplace in which a
vent-free appliance is installed.
8.If appliance has glass doors,neveroperatethis
appliance with glass doors closed. Any glass
doorsshallbefullyopenedwhentheappliance
is in operation. If you
operate appliance with
doors closed, heat buildup inside fireplace will
cause glass to burst. Make sure there are no
obstructions across openings of fireplace.
9.This log heater is designed to be smokeless. If
logs ever appear to smoke, turn off heater and
callaqualifiedserviceperson.NOTE:Duringinitial
operation, slight smoking could occur due to log
curingandheaterburningmanufacturingresidues.
Installation and repair should be done
by a qualified service person. The ap-
pliance should be inspected before use
and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint
from carpeting, bedding material, etc. It
isimperativethatcontrolcompartments,
burners,andcirculatingairpassageways
of the appliance be kept clean.
1. WARNING: This appliance is only for
use with the type of gas indicated on
the rating plate. This appliance is not
convertible for use with other gases.
10. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
Page 25.
11.Beforeusingfurniturepolish,wax,carpetcleaner
or similar products, turn appliance off. If heated,
the vapors from these products may create a
white powder residue within burner box or on
adjacent walls and furniture.
12. This appliance needs fresh, outside air ven-
tilation to run properly. This appliance has an
OxygenDepletionSensing(ODS)safetyshutoff
system. The ODS shuts down the appliance if
enough fresh air is not available. See Air for
Combustion and Ventilation, Page 6. If appli-
ance keeps shutting off, see Troubleshooting,
Page 26.
13. Do not run appliance
• whereflammableliquidsorvaporsareusedor
stored
• under dusty conditions
14. Donotusethis appliance to cookfoodorburn
paper or other objects.
15. Do not use this room heater if any part has
been under water. Immediately call a qualified
service technician to inspect the room heater
and to replace any part of the control system
and any gas control which has been under
water.
16. Do not operate appliance if any log is broken.
Do not operate appliance if a log is chipped
(dime-sized or larger).
17.
Turn appliance off and let cool before servic-
ing, installing or repairing. Only a qualified
service person should install, service or repair
appliance.
18. Operatingappliance aboveelevationsof4,500
feet may cause pilot outage.
19. To prevent performance problems, do not
use propane/LP fuel tank of less than 100 lb.
capacity (propane/LP units only).
20. Provideadequateclearancesaroundairopen-
ings.
21. Solid fuels shall not be burned in a fireplace
in which an unvented room heater is installed.
23. Follow the clearance requirements within
this manual to assure adequate clearances
for accessibility for purposes of servicing and
proper operation.
24. Installation and the provisions for combustion
andventilationairmustconformwiththeNational
Fuel Gas Code, ANSI Z223.1/NFPA 54.
25. When installing as a vented appliance in a
manufactured home or mobile home, the in-
stallationmustconformwiththeManufactured
HomeConstructionandSafetyStandard,Title
24 CFR, Part 3280, or when applicable, with
Manufacture Home Installations Standard,
ANSI/NCBCS A225.1/NFPZ 501A.