Setting adjustments
DETECTION RANGE:
the detection range refers to the greatest
distance from which an object can be sensed in order to activate the
system. Press the RANGE button and wait for a quick ashing of the
LED in the sensor eye. Then, press + to increase the detection range
and -to decrease it.
NOTE: once the detection range has been set using the remote control,
this range is memorized even in the event of a power cut.
SELF ADJUSTMENT MODE:
to activate, rst ensure that no objects
are in front of the sensor. Press the ADJ button and wait for a quick
ashing of the LED in the sensor eye. Move the hand that is holding the
remote control, away from the sensor area. The ideal sensor range for
each specic location will be set automatically. Once self-adjustment
has taken place, the solenoid valve will open and close for one second
as an indication that the ideal sensor range has been set, and
the product is ready for use.
TRIGGERING TIME:
it is recommended to change the triggering time
only for WC and urinal ushes. This prevents unintentional activations
which may occur when someone passes by the WC or urinal without
intending to use it. By adjusting the triggering time, the system will
only be activated after a minimum presence time has elapsed.
If necessary, the triggering time can be adjusted as follows:
press the IN button. Wait for the blue light to ash on the sensor.
Then press + to increase the safety time or –to decrease it
.
FLOW TIME
: this button applies to ush valves for toilets and urinals
with an infrared dual ush system. For these ush valves, the full ow
time can be adjusted using the double wave button. If required, adjust
the full ow time as follows: press the double wave button and wait for
a quick ashing of the LED in the sensor eye. Then, press +to increase
the ow time and - to decrease it.