THE ENVIRO LOO
Model: Commercial C-60
Installation INSTRUCTIONS
© SWSLoo, Inc 2020
Please call us if you have any
questions. It is very important
that the Eloos are assembled
correctly.
We are always happy to help.
Thank you for your business.
Toll Free: 866-797-3566
Or: 512-285-9494
Page 2of 10
© SWSLoo, Inc 2020
Parts and Pieces Inside Your Shipment
If your unit has been shipped unassembled, please see assembly
instructions prior to installation instructions. However, if you’ve already
assembled the unit, or it was shipped assembled, please follow the
directions to insert the Inlet Vents and Inlet Vent Pipes prior to actual
installation.
Page 3of 10
© SWSLoo, Inc 2020
Inlet Vent Installation
1.) The inlet vents come separated, as pipes –usually in exhaust stack, and
the vent pieces –usually in the drying bag. They have been marked for
your convenience.
You will need to place the Inlet Vent Pipes inside the unit. The bottom of
the pipes will pass through the drying tray through the designated slots.
Insert the Inlet Vents into the opening of the unit, from the outside, then
reaching through the manhole/access to unit, bring the inlet vent pipe
upwards, attaching the white fitting over the back of the inlet vent.
Page 4of 10
© SWSLoo, Inc 2020
ELoo Installation Instructions
Once your ELoo has the Inlet Vents inserted, permanently secure them
using PVC pipe glue or a #8 Self-tapping screw. **Make sure fittings are
fully seated.**
A.) Underground Installation –Single C60
**See Urinal Instructions if you are adding a Urinal to your Installation.**
Page 5of 10
© SWSLoo, Inc 2020
***The unit MUST to be anchored to avoid floatation.*** Attach anchors
level and evenly on either side of the bottom of the unit. (Position rear
anchor cable between unit and inverted bolts.) When backfilling, ensure
anchors remain in position.
Page 6of 10
© SWSLoo, Inc 2020
B.) Underground Installation –Double (Two C60s)
Excavate a pit: 8.5’l X 8.5’w X24-30”h
Ensure accurate alignment of height to
final floor level.
Note: if the units are outside toilet
structures, we recommend a step-up of
8”to avoid storm water run-off.
** Remove any rocks from the bottom of the pit that may cause damage to the
unit.
Use approximately 2”of river sand or soft soil to level the bottom of the pit. If
installing the unit in Clay or high ground water area, concrete footings can be
poured into the bottom of the pit leaving exposed rebar or adding hooks for
securing tie downs for the anchor cables/ropes.
Page 7of 10
© SWSLoo, Inc 2020
** Complete backfill of pit as instructed in Single, C60 Installation
(above) ***
C.) Above ground Installation
Please call SWSLoo, Inc
866-797-3566
Or 512-285-9494
Additionally, you can email:
George@swsloo.com
** Set the two units so as
to measure 40 inches
center to center of the
toilet flanges.
This allows for a 4 inch
wall between the units
and provides 18 inches
from the side wall to
comply with ADA
requirements.
With two or more stalls with ELoos are to be unisex individual stalls, and will
each have a urinal:
1.) Bulkhead connectors have been installed into the unit for you on the
lower 󰝓󰝔󰝕wall below the toilet flange.
2.) The idea here is to connect the two bulkhead connectors with PVC
one or 1 ¼ inch pipe and stub out for urinals from each unit. This will
allow equalization of the liquid level in the event of excessive use.
Page 8of 10
© SWSLoo, Inc 2020
Building Slab For ELoo Surround
**Completed structure MUST have a vent to the outside**
Page 9of 10
© SWSLoo, Inc 2020
Installation of Remaining Components:
Toilet:
Exhaust Stacks:
Page 10 of 10
© SWSLoo, Inc 2020
Drying Bag and Rake:
Auxiliary Items available for purchase from SWSLoo, Inc (including an auxiliary
fan to assist with air flow and a urinal).

Popular Toilet manuals by other brands

XCQQ S8L instruction manual

XCQQ

XCQQ S8L instruction manual

Laufen CAPRINO PLUS H841065 installation instructions

Laufen

Laufen CAPRINO PLUS H841065 installation instructions

Gustavsberg NORDIC 3 installation instructions

Gustavsberg

Gustavsberg NORDIC 3 installation instructions

Etac Kaskad manual

Etac

Etac Kaskad manual

Separett Tiny 1270 user manual

Separett

Separett Tiny 1270 user manual

WimTec INSIDE Assembly and operating instructions

WimTec

WimTec INSIDE Assembly and operating instructions

contrac 4760BKV instructions

contrac

contrac 4760BKV instructions

GALA Innova Inspira manual

GALA

GALA Innova Inspira manual

TRONE GANZA II instruction manual

TRONE

TRONE GANZA II instruction manual

Lacava Navi N5051WC owner's manual

Lacava

Lacava Navi N5051WC owner's manual

Olympia FANTOM 69200 Installation and Maintenance

Olympia

Olympia FANTOM 69200 Installation and Maintenance

American Standard OLYMPUS O2 installation instructions

American Standard

American Standard OLYMPUS O2 installation instructions

Toto NEOREST 750H instruction manual

Toto

Toto NEOREST 750H instruction manual

Thetford C260 Cassette Toilet installation instructions

Thetford

Thetford C260 Cassette Toilet installation instructions

Invacare Aquatec Pure Bidet user manual

Invacare

Invacare Aquatec Pure Bidet user manual

Dometic CT 4110 installation manual

Dometic

Dometic CT 4110 installation manual

TRONE Aquatina III A3ETBCERN-12.WH installation manual

TRONE

TRONE Aquatina III A3ETBCERN-12.WH installation manual

Drive DeVilbiss Healthcare 12027RA instruction manual

Drive DeVilbiss Healthcare

Drive DeVilbiss Healthcare 12027RA instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.