DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 9
5. For each camera to be connected to the system:
a. Press Camera button: for analog cameras set Input Mode
=Color/BN, for IP cameras select Enable and set Model and
IP Address (or perform an automatic search pressing the
button Detect), followed by the button Probe/Connect to
establish video connection.
b. To set up recording on motion detection press the button
Motion of each camera, define the detection area using the
drawing tools and set alarm thresholds.
6. To configure the cameras to record press the Phase settings button
and activate the base recording (column with red dot) or the alarm
recording (column with green bell) for each camera in the
“Recording Settings” section. To enable the operation of the
secondary monitor, select the corresponding check.
7. To enable the user management press “User Accounts”, enter user
name and password with supervisor rights (AC) defined on the
system. Factory defaults are User = SUPER and Password = SUPER.
Enable the option Access Control enabled. To reset the password
select the user’s row, press the Modify button and change the
password field.
8. To enable recording, exit the configuration screen and, in the main
screen, press the record button (red dot). While recording the
cameras will be indicated in pink (base recording) and in red color
(alarm/motion recording).