SYAC-TB DIGIEYE COMPACT Specification sheet

DIGIEYE COMPACT
Quick setup
V1.5 09-2016
IT

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 2
1. List of components
1 Digieye unit
1 AC 110-230V –
DC 12V 5A
Adapter
1 Power
supply
cable
Documentation
Warranty
2 CDROM:
CD1: Manuals
+ Software PC
CD2: Digieye
installation
1 video-mux
BNC cable (8
ch)
2 video-mux
BNC cable (16
ch)
Not included
with NVR.
1 terminal block
9-pin (I/O)
1 USB
mouse

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 3
2. System description
HDD
Hard disk status LED
LAN1
Primary network port RJ45
PWR
Power supply status
LAN2
Secondary network port RJ45
VGA
VGA video output
AUDIO
Mic/Line=inputs, Spk=output
HDMI
HDMI video output
VIDEO IN
Video inputs BNC (CVBS)
CVBS
CVBS video output (optional)
I/O
Alarm input / relay output
USB
USB 2.0 ports (1 front, 2 rear)
RES
Software reset button (only in
case of emergency)
USB 3.0
2 USB 3.0 ports (blue)
DC
Power connection 9-30Vdc
(60W)
USB

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 4
3. Positioning
Place the unit upright, on a stable and solid surface, making sure
that the 4 spacers supplied (A)are well placed in the base.
Check that the slots in the chassis are not obstructed. Leave the top
surface free and keep a free distance of at least 20 cm all around
the unit.
Do not place the unit near sources of heat or closet or other
electronic devices while operating.
For optimal operation, keep the room temperature below 35°C.
CAUTION
HIGH TEMPERATURE OF
METALLIC CASE
The unit is provided with a passive cooling system (fanless), which
transfers the heat on the metal walls of the chassis, which therefore
may be very hot (up to 60°C).
It is recommended to turn off the system and let it cool at least 15
minutes before handling.
20 cm
A
20 cm

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 5
4. Installation
1. Primary Monitor (MAIN) / Secondary (AUX)
DigiEye is able to control up to 2 video monitor outputs simultaneously.
Monitor
Function
Primary (main)
Configuration/Maintenance, Video Monitoring and
alarms
Aux (secondary)
Video display live/playback (multi-split)
The unit is provided with 1 digital HDMI video output, 1 VGA analog video output
and optionally 1 CVBS output. Optional video adapters are available to connect
different types of monitor interfaces using video adapters.
1
2
4
6
5
3
Primary Network (f.ex. Centralization)
Secondary Network (f.ex. IP Cameras)
1
2
3
4
5
6
7
8
9
Primary
Monitor
MAIN
Secondary
Monitor
AUX
conv.USB-RS485
(COM4)
USB storage
conv.USB-RS485
(COM3)
Keyboard / mouse USB

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 6
Refer to the below chart to configure the connections, depending on the
number of monitors to be connected to the DigiEye:
Configuration
Interface
Monitor 1
Monitor 2
A.
1 monitor (VGA)
VGA
Main/Aux (1)
---
B.
1 monitor (HDMI)
HDMI
Main
---
C.
1 monitor (CVBS)
CVBS
Aux (1)
D.
2 monitors (2)
(HDMI+VGA)
HDMI
Main
VGA
Aux
E.
2 monitor (2)
(HDMI+CVBS)
HDMI
Main
CVBS
Aux
(1) It’s possible to force Aux in the system reinitialization program
(2) The monitors must be connected and switched on BEFORE powering up
Digieye. If Digieye restarts and does not find the connected monitor (eg.
The monitor is turned off) this will not be detected by Digieye,
consequently disabling the Main / Aux output. You will need to restart
the Digieye system to detect the monitor.
DigiEye automatically detects the monitors connected to the system at boot and
sets the MAIN/AUX video interfaces resolution to optimal values.
We recommend to use monitors with the following technical characteristics:
Type of DigiEye
Optimal video resolution
A/R
DVR
1024 x 768
1280 x 1024
1600 x 1200
4:3
5:4
4:3
HVR / NVR
1440 x 900
1920 x 1080 (Full-HD o 1080p) (*)
16:10
16:9
(*) The new DigiEye user interface (dark gray) is enabled only when a Full-HD
primary (MAIN)monitor is being used (resolution 1920x1080).
If no monitor is connected to the system at boot, it will activate the MAIN or AUX
interface anyway (depending on the configuration) that will be displayed once a
monitor will be connected on one of video interfaces.
When you change a monitor or a video port, we suggest to reboot the system
(shutdown/restart).
2. Connection of USB devices
Connect the USB devices using the below chart:
USB ports
Supported Devices
USB
(1 on the front and 2
on the rear, white)
USB Mouse/Keyboard
USB Storage (backup)
CONV.USB-485 (opt.) –COM3
USB 3.0
(2 on the rear, blue)
USB Mouse/Keyboard
USB Storage (backup)
CONV.USB-485 (opt.) –COM4
3. LAN/WAN Network Connection

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 7
Use LAN1 / LAN2 ports to connect the Digieye to the network. Up to 2 networks
can be connected to the system, with different management modes
(backup/load-balance/dual-homing). If you use only 1 network, use the LAN1
port. Network interfaces are of the 10/100/1000 Base-T/Base-TX (self-adaptive)
kind. We recommend to use professional network switch and shielded cables
CAT-5e (minimum) to achieve optimal network performances.
4. Analog Cameras Connection (mod. DVR/HVR)
In DVR/HVR units, connect the analog cameras through the multi-BNC adapter
cables provided, to VIDEO IN ports.
The DigiEye COMPACT unit is not provided with loopthrough BNC video output.
5. Inputs/Outputs connection
The DigiEye COMPACT unit is provided with:
4 opto-isolated inputs, dry contacts (potential free) –common GND
2 relay Outputs (24VDC/1A), potential free –with maximum load of 1A at
24 Vdc for each output.
The following chart shows the contacts available on the terminal :
Pin
Description
1
GND
2
IN1
3
IN2
4
IN3
5
IN4
6
OUT1A
7
OUT1B
8
OUT2A
9
OUT2B
6. Power Supply
Connect the power supply to 4 poles Mini-DIN socket on the rear of the unit.
The connector has the following pinout:
The DigiEye unit is supplied with an AC-DC transformer12Vdc/5A.
DigiEye COMPACT starts as soon as it receives power.
For all eventualities, DigiEye is protected against reverse polarity of the input
voltage.
For EN 50130-4 DigiEye must be connected to a UPS system.
Power Supply
Tension
9 –30 Vdc
(recommended
12Vdc)
Power
60W (max.)
GND
V+

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 8
5. Initial Configuration
(Legacy interface)
1. Press the button with SYAC-TB logo
2. Press the Configuration button (tools icon)
3. Set local parameters (“Configure” button)
a. System name
b. Date/time
c. Number of analog/IP channels (for hybrid systems)
d. Automatic recording reactivation time
4. Network parameters setup (“TCP/IP” button)
a. Static or dynamic IP address (DHCP) for LAN1 interfaces and,
if necessary, LAN2.
1
2
3
4
5a
6
5b
8
7

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 9
5. For each camera to be connected to the system:
a. Press Camera button: for analog cameras set Input Mode
=Color/BN, for IP cameras select Enable and set Model and
IP Address (or perform an automatic search pressing the
button Detect), followed by the button Probe/Connect to
establish video connection.
b. To set up recording on motion detection press the button
Motion of each camera, define the detection area using the
drawing tools and set alarm thresholds.
6. To configure the cameras to record press the Phase settings button
and activate the base recording (column with red dot) or the alarm
recording (column with green bell) for each camera in the
“Recording Settings” section. To enable the operation of the
secondary monitor, select the corresponding check.
7. To enable the user management press “User Accounts”, enter user
name and password with supervisor rights (AC) defined on the
system. Factory defaults are User = SUPER and Password = SUPER.
Enable the option Access Control enabled. To reset the password
select the user’s row, press the Modify button and change the
password field.
8. To enable recording, exit the configuration screen and, in the main
screen, press the record button (red dot). While recording the
cameras will be indicated in pink (base recording) and in red color
(alarm/motion recording).

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 10
6. Initial Configuration
(Full-HD interface –from s/w 6.0)
1. Press the Configuration button (tools icon) and refer to the former
section.
2. At the end of system configuration press the REC button to start
Video Recording.
1
2

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 11
1. Reset to factory configuration
In case you want to reset the system configuration to the factory defaults,
proceed as follows:
1. Turn off the DigiEye system and connect a USB mouse and a monitor
to the VGA or HDMI port.
2. Turn on the system and during the initial loading (boot) hold both
the left and right mouse buttons SIMULTANEOUSLY, moving the
mouse at the same time.
3. At the prompt for User / Password : enter username and password
with Supervisor rights (AC) defined on the system. Factory defaults
are User = SUPER and Password = SUPER. In case of User/Password
loss, please contact SYAC-TB technical support.
4. To completely reset the configuration press the following key
sequence:
a. Reinitialize configuration
b. Reinitialize TCP/IP settings
c. Delete sequences
d. Exit
5. Wait until system reboots.

DIGIEYE COMPACT Informazioni di base
EN-UM-DGI.CO2.A
Rev. 1.4
Page 12
1. Technical Support
The instructions in this document are a simplified base example.
For a detailed description of the DigiEye system and a complete guide to its
configuration we recommend to read the user manual, available in digital
format on the supplied CD.
The latest version of the manual can also be downloaded from the restricted
area of SYAC-TB site (requires registration)
www.syac-tb.com
To contact SYAC-TB technical support:
Phone: +39-059-289899
English
Correct Disposal of this Product (electrical and electronic waste)
This marking shown on the product or its literature, indicates
that it should not be disposed with other household wastes at
the end of its working life.
To prevent possible harm to the environment or human health
from uncontrolled waste disposal, please separate this from
other types of wastes and recycle it responsibly to promote the
sustainable reuse of business users should contact their supplier and check
the terms and conditions of the purchase contract. This product should
not be mixed with other commercial wastes for disposal.
Table of contents
Popular Security System manuals by other brands

Defender Security
Defender Security FOOTBALL ALARM manual

Alarm Lock
Alarm Lock 715 quick start

Tyco
Tyco DSC SCW9055 user manual

Swann
Swann SW231PC4 operating instructions

Edaphic Scientific
Edaphic Scientific ESRAD-200 operating instructions

Response Electronics
Response Electronics miGuard G5 Installation and operating instructions

Pfannenberg
Pfannenberg DS Series Instructions for operating and installing

DSC
DSC PowerSeries Neo HS2064 E user manual

SJE Rhombus
SJE Rhombus Xpert Alert quick start

Pyronix
Pyronix EURO 46 V10 installation manual

Star Headlight & Lantern
Star Headlight & Lantern StarSignal SS741MG-11 Installation and operating instructions

ERA
ERA Protect SALAPWHESSU Installation and operating manual