Sylvania QUICKTRONIC T4 User manual

56
Lamp/Ballast Guide
Key System Features
System Information Plastic Enclosure Styles (S)
■Universal Input Voltage
■PROStart®Ballasts
■QUICKSENSE® Ballast Technlgy.
■High Power Factor
■Low Harmonic Distortion
■Small size and lightweight
■Metal or plastic enclosure
■UL, CSA, FCC
■QUICK 60+ warranty
■Dual-Mounting option
SYLVANIA
QUICKTRONIC CF
is ideally suited for:
■ Recessed Downlights
■Wall Sconces
■ Ceiling Fixtures
■Commercial
■Retail, Hospitality, Institutional
Application Information
Primary Systems
13W T4 – DULUX D/E, T/E
1-lamp or 2-lamp
QTP1/2x13CF/UNV DS
18W T4 – DULUX D/E, T/E
1-lamp or 2-lamp
QTP1/2x18CF/UNV DS
26W T4 – DULUX D/E, T/E
1- or 2-lamp
QTP2x26/1x42/32CF/UNV DS
32 or 42W T4 – DULUX T/E
2-lamp QTP2x26/32/42CF/UNV DM
1-lamp QTP2x26/1x42/32CF/UNV DS
57W or 70W T4 – DULUX T/E
1-lamp QTP2x26/32/42CF/UNV DM
For other lamp types, refer to the
Performance Guide section on the
next page.
SYLVANIA QUICKTRONIC CF
operates DULUX®D/E and T/E
lamps with full lumen output and
optimal system performance.
QUICKTRONIC CF Dual-Mount
features low profile, lightweight
enclosures to provide simple
assembly for any fixture appli-
cation. Mounting screws are
provided with the ballast to
enable either a bottom-mount or
a top-mount installation. A wiring
kit and an extraction tool is
provided for ease of installation.
A separate mounting bracket is
available that allows these
electronic ballasts to replace
magnetic-style CFL ballasts.
Universal Input Voltage
(120–277V) and multi-lamp
multi-watt capability allow for
fewer SKUs to support a wide
range of applications.
Setting the standard for quality,
QUICKTRONIC CF is also
covered by our QUICK 60+®
warranty, the first and most
comprehensive system warranty
in the industry.
PROStart®programmed rapid
start is the optimum starting
method, providing up to
100,000 switching cycles for
use on occupancy sensors and
building control systems.
QUICKSENSE®end of lamp life
sensing technology helps to
protect against overheated
bases and sockets, as well as
cracking of the glass wall.
QUICKSENSE ballast
technology uses dynamic
end-of-lamp-life sensing to
avoid false shutdowns caused
by some static sensing
methods and will auto-reset
when the end-of-life lamps are
replaced with new ones.
QUICKTRONIC CF comes with
wire-trap connectors for quick
and easy installation.
A complete OSRAM SYLVANIA
System Performance Guide
showing performance
characteristics of lamps and
ballasts is available upon
request.
Metal Enclosure Styles (M)
Mounting Bracket (51814)
QUICKTRONIC®CF – UNIVERSAL DUAL MOUNT
<10% THD Electronic T4 Compact Fluorescent Systems
DS = Dual Mount for recessed
downlight fixtures or ceiling
and wall sconce installation
DM = Dual Mount for recessed
downlight fixtures or ceiling
and wall sconce installation
Professional Series
57
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
Starting Method: PROStart®
Programmed Rapid-Start
Circuit Type: Series
Lamp Frequency: > 40KHz
Lamp CCF: Less than 1.7
Starting Temp: –5°F/–20°C min.5
Input Frequency: 50/60 Hz
Low THD: < 10%
Power Factor: > 98%
Voltage Range: 108–305V
UL Listed Class P, Type 1 Outdoor
CSA or C/UL Certified
75°C Max Case Temp. (5 yr. warranty)
80°C Max Case Temp. (3 yr. warranty)
FCC 47CFR Part 18 Non-Consumer
Sound Rated A
ANSI C62.41 Cat. A Transient Protection
Dynamic End-of-Lamp-Life Sensing
Remote Mounting Capability6
Performance Guide
Specifications*
Ordering Guide
<10% THD Electronic T4 Compact Fluorescent Systems
Dimensions: Packaging:
Metal “M” case: 4.95" L x 2.93" W x 1.35" H Quantity: 1 piece
Plastic “S” case: 4.95" L x 2.37" W x 1.10" H Weight: 0.40 lbs ea. (Plastic “S” case)
Mounting: Utilize flanges (4.57" L) 0.90 lbs ea. (Metal “M” case)
* See the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide (ECS-ELECTRONIC) for additional information.
* See wiring diagrams for proper installation.
5 Operation below 50°F may affect light output or lamp operation – see “Low Temperature Starting definition.
6 Typically 6 ft. with suitable ground plane, but varies by model and application – please contact ECS Application Engineering for information on longer applications.
Input Input Rated2Ballast Input System
Item Voltage Current Lamp1Lumens No. of Factor System Power Efficacy
Number Description3(VAC) (AMPS) Type (lm) Lamps (BF) Lumens (Watts) (lm/W)
13W DD/E,T/E 900 1 1.00 900 16 56
51810 QTP 1/2x13CF/UNV DS 120-277 0.25/0.11 13W DD/E,T/E 900 2 1.00 1800 29 62
18W DD/E,T/E 1200 1 1.00 1200 20 60
51811 QTP 1/2x18CF/UNV DS 120-277 0.32/0.14 18W DD/E,T/E 1200 2 1.00 2400 38 63
26W DD/E,T/E 1800 1 1.00 1800 28 64
51812 QTP 2x26/1x42/32CF/UNV DS 120-277 0.50/0.22 26W DD/E,T/E 1800 2 1.00 3600 54 67
32W DT/E 2400 1 0.98 2350 35 67
42W DT/E 3200 1 1.00 3200 45 71
26W DT/E 1800 2 1.02 3670 54 68
32W DT/E 2400 2 0.96 4600 69 67
518134QTP 2x26/32/42CF/UNV DM 120-277 0.90/0.40 42W DT/E 3200 2 0.95 6080 94 65
0.53/0.23 57W DT/E 4300 1 1.00 4300 62 69
0.57/0.25 70W DT/E 5200 1 0.92 4780 71 67
1 Also compatible with other manufacturers’ equivalent 4 pin lamp types that meet ANSI standards.
2 Rated lamp lumens and performance data based on DULUX T/E series 4 pin lamps.
3 Data is for all three models within the brackets. The maximum input current is shown for maximum input power.
4 Q1 2006
Item Number 51813 QTP 2 x 26/32/42 CF/UNV DM Case Type (Mounting Style)
QUICKTRONIC PROFESSIONAL Line Voltage
Number of Lamps (1, 2) Primary Lamp Wattage
DUAL MOUNT
CF UNIVERSAL
Normal Ballast Factor
BALLAST
Green
Black
White
Blue
Red
R
R
Blu
Blu G
B
W
L
A
M
P
Blue
Red
Y
Y
BALLAST
R
R
Blu
Blu
W
Y
Y
L
A
M
P
L
A
M
P
Red
Red
Blue
Blue
Yell o w
White
Black
B
Yell o w
BALLAST
Green
R
R
Blu
Blu
G
B
W
Y
Y
L
A
M
P
L
A
M
P
Red
Red
Blue
Blue
Yell o w
Yell o w
White
Black
System Life / Warranty
QUICKTRONIC products are covered
by our QUICK 60+ warranty, a
comprehensive lamp and ballast
system warranty. For additional
details, refer to our QUICK 60+
warranty bulletin.
Specifications subject to change
without notice.
Wiring:
Push-in connectors
(no leads provided)
Use 18AWG solid copper wire only
BALLAST
White
Blue
Red
R
R
Blu
Blu
W
L
A
M
P
Blue
Red
Y
Y
Black
B
Metal “M” Case Plastic “S” Case
QTP 2x26/1x42/32CF/UNV
model also operates:
1-lamp CF28/2D, CF38/2D,
FPC40/T5, FT40DL
1- or 2-lamp
FPC22/T5, FT24DL, FT24DF
2-lamp CF13DSE, FT18DL,
FT18DF, CF21/2D
QTP 2x26/32/42CF/UNV model
also operates:
2-lamp FT36DL, FT40DL,
FPC40T5
1+1 FPC22/T5 / FPC40/T5

Other Sylvania Indoor Furnishing manuals

Sylvania QUICKTRONIC T8 User manual

Sylvania

Sylvania QUICKTRONIC T8 User manual

Sylvania QUICKTRONIC HELIOS 49671 User manual

Sylvania

Sylvania QUICKTRONIC HELIOS 49671 User manual

Sylvania DULUX 20676 Manual

Sylvania

Sylvania DULUX 20676 Manual

Sylvania QUICKTRONIC POWERSENSE T5 User manual

Sylvania

Sylvania QUICKTRONIC POWERSENSE T5 User manual

Sylvania DULUX 20566 Manual

Sylvania

Sylvania DULUX 20566 Manual

Sylvania QUICKTRONIC POWERSENSE T8 User manual

Sylvania

Sylvania QUICKTRONIC POWERSENSE T8 User manual

Popular Indoor Furnishing manuals by other brands

Hülsta now! no.14 Cover Shelve 30750 Assembly instruction

Hülsta

Hülsta now! no.14 Cover Shelve 30750 Assembly instruction

SYDELL 930-2 Assembly instructions

SYDELL

SYDELL 930-2 Assembly instructions

Belnick WL-3958SYG-BK-GG Assembly instructions

Belnick

Belnick WL-3958SYG-BK-GG Assembly instructions

studioduc juno stacking toy storage Assembly instructions

studioduc

studioduc juno stacking toy storage Assembly instructions

Arthauss Furniture KLARA Assembly instructions

Arthauss Furniture

Arthauss Furniture KLARA Assembly instructions

Walker Edison TW42BR3PC Assembly instructions

Walker Edison

Walker Edison TW42BR3PC Assembly instructions

Woodard WDC-WOO-9240 Assembly instructions

Woodard

Woodard WDC-WOO-9240 Assembly instructions

Venjakob 4400 Assembly instructions

Venjakob

Venjakob 4400 Assembly instructions

J.Burrows OTVEN3DWE Assembly instruction

J.Burrows

J.Burrows OTVEN3DWE Assembly instruction

Creative Outdoor Solutions SWIVEL PAD STOOL Assembly instructions

Creative Outdoor Solutions

Creative Outdoor Solutions SWIVEL PAD STOOL Assembly instructions

ROHDE & GRAHL xpendo plus XP33 operating instructions

ROHDE & GRAHL

ROHDE & GRAHL xpendo plus XP33 operating instructions

Micasa BICO Goodnight Boxspring installation instructions

Micasa

Micasa BICO Goodnight Boxspring installation instructions

HiB Maxi 73106100 Fitting instructions

HiB

HiB Maxi 73106100 Fitting instructions

Naterial LAGUN ALU 2022R09P01-0332 Assemby - Use - Maintenance Manual

Naterial

Naterial LAGUN ALU 2022R09P01-0332 Assemby - Use - Maintenance Manual

Tradecraft Specialties BULLDOZ-10 instruction manual

Tradecraft Specialties

Tradecraft Specialties BULLDOZ-10 instruction manual

MIDJ Alfred Table manual

MIDJ

MIDJ Alfred Table manual

bbf CH1303BLF-03 Assembly and operating instructions

bbf

bbf CH1303BLF-03 Assembly and operating instructions

Auping Kiruna Sami user manual

Auping

Auping Kiruna Sami user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.