Synergys LEAKSHOOTER LKS1000 V3+PRO User manual

SUMMARY
PACK LKS1000 V3+PRO 3
WHAT IS LEAKSHOOTER®? 4
HOW TO WORK WITH LEAKSHOOTER®? 4
DETAIL OF LEAKSHOOTER®6
DETAIL OF KEYBOARD 7
DETAIL OF SCREEN 8
BATTERY CHARGING 9
ON / OFF 9
MAIN MENU 10
K, HOW IT WORKS? 12
K, CONDITION OF USE 12
K, WITHOUT SETTINGS 13
K, WITH SETTINGS 13
THERMAL CAMERA (V3+PRO) – HOW IT WORKS? 14
STRAPSHOOTER+®(V3+PRO) – HOW IT WORKS? 16
STRAPSHOOTER+®(V3+ PRO) – REAL TIME 17
STRAPSHOOTER+®(V3+ PRO) – AUTO 18
MAIN ICONS USED IN LEAKSHOOTER®20
ACCESSORIES LEAKSHOOTER®DETAIL 22
—2 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

WHAT IS A
LEAKSHOOTER®?
LEAKSHOOTER®LKS1000 V3+PRO is a portable detection
device that helps locate, hear, view, measure and record
leaks which emit ultrasounds. It can estimate the leak
ow and the leak cost for each leak.
It has also a special expert program STRAPSHOOTER+®
dedicated to STEAM TRAP condition analysis and an em-
bedded 160x120 pixels thermal imaging camera.
Main industrial applications are:
LCompressed air leak detection
LCompressed process gases leak detection
LVacuum leak detection
LSteam trap or valve condition analysis
LHigh voltage capacitive default detection (corona,
arcing, tracking…)
LTightness checking and seal integrity test (with
ultrasonic emitter)
HOW TO WORK WITH
LEAKSHOOTER®?
LEAKSHOOTER®LKS1000 has been designed to display in
real time the fusion of images of the scene being scanned
and the detected ultrasounds coming from a leak (ultra-
sound received = white or colored dynamic target).
Depending on the leak size (intensity of ultrasonic waves
received around 40 kHz) and on the settled sensitivity
(GAIN), the dynamic target will be big or small (white).
Of course if you want to know the leak severity, please
click on the K function button. The target will then have
a severity color (LEAKSCORE from 0 to 100 is made for a
1 meter distance detection).
LEAKSHOOTER®LKS1000 is equipped with a special MAX
RMS value function which thanks to the target, shows you if
you are close to the leak (simple round target) or in front of
the leak (round target + cross in its center).
—4 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

The method consists of scanning the scene, conscientiously.
From far to close location. Do not forget to decrease GAIN
slowly to avoid saturation.
Start with the maximum of sensitivity (GAIN=106 dB,
settled when the device is switched ON).
Sweep the scene for example from left to right and from
top to bottom, with the aim of going in front of the leak and
thus activating the special MAX value, which will remain
frozen a few seconds (bold vertical line in the bargraph).
If you still have the white target with cross, everywhere,
Leak &
ultrasound
it is because you are in a saturated zone. Look on the
ground with LEAKSHOOTER®, slightly decrease the GAIN to
be in the green part of the bargraph and scan again in such
a way as to nd a direction in which to go.
Thus, go back to the area to nd this special MAX value
(align RMS real time and MAX). You will see a cross in the
center of the dynamic target. You are in front of the leak.
—5 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

DETAIL OF
KEYBOARD
With LEAKSHOOTER®LKS1000 V3+PRO Keyboard
Power plug
(12V-1.5A)
Micro USB plug
Wired head phone
jack plug
External probe plug
ON/OFF
STRAP-
SHOOTER+®
Gain
setting
(+or-)
Validation
or Menu Headphones level
setting (+or-)
Photo
capture
DETAIL OF A
LEAKSHOOTER®
Thermal
camera
—7 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

DETAIL OF SCREEN
INT or EXT
Internal (cone) or
External sensor
Sensitivity
(Gain) level
Target which is
white or colored
(if K is activated
or not)
Bargraph which
is white or
colored if K is
activated or not
Max RMS
«Large» cursor
Real time RMS
«Thin» cursor K cursor zone dB RMS
value
Battery level
Flow/Cost
estimation
K value position
K estimator
Severity (0>100)
K value
—8 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

BATTERY CHARGING
LEAKSHOOTER®LKS1000 V3+PRO have an internal NiMH
(Nickel Metal Hybrid) battery pack technology (6x 1,2V-2600
mAh). To charge this battery pack, please only do it with the
delivered charger DC 12V-1,5A.
Maximum recommended charging time is about 2H30.
Do not leave your device unattended.
Please be careful not to charge several times (connect
- disconnect - connect…) within a few hours. It could
disturb the automatic ending charge detection.
Feeling some heat at the end of the charging process is normal.
Note: If you want to store your LEAKSHOOTER®during
a long time without using it, please charge it to its 100%
capacity before! Then you will be able to use it after seve-
ral months without any problem.
ON/OFF
•Switching ON:
Briey press the button , LEAKSHOOTER®starts
5 seconds after initialization.
•Switching OFF:
Press for a longer time (> 3 seconds) the button ,
LEAKSHOOTER® goes to switch OFF.
—9 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

A. INT (cone) or EXT (exible or contact) sensor
B. LED light activation
C. Memory with leakage photos
D. USB LINK activation
E. General settings
F. K (Severity and Estimator of leak ow/cost) settings
G. Limit of green/white part of bargraph adjustment
H. Bluetooth activation
I. Activation of K function
J. Escape icon
MAIN MENU
(VIA OK BUTTON)
A
E
I
C
G
B
F
J
D
H
—10 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

A. It conrms the used sensor between cone (INT) or
exible/contact (EXT).
When you connect an external sensor, it is automati-
cally detected as EXT (same when removing it).
B. To help you to have a better light to take a picture
in a dark situation.
C. To be able to review stored leakage photos
(READ or CANCEL).
You can navigate with or buttons and escape
with .
To cancel a photo, click on the PHOTO button .
D. To download photos to PC or to update device.
Connect your device (ON) to PC with USB cable, acti-
vate USB LINK and wait with WINDOWS function.
Copy / Paste / Delete your photos. Before
disconnecting, be sure to eject USB with WINDOWS func-
tion.
E. To set clock/date, luminosity (5 per default),
Auto o, frequency mixing (42 kHz per default).
F. K (Severity and Estimator of leak ow/cost) settings.
If you need a ow/cost estimation, please ful-
ll h/Y compressor use and Nm³ cost. To do that, click
on the icon and go to the virtual keyboard with .
Choose your number and valid it with the virtual
keyboard Enter button.
G. Limit of green/white part of bargraph adjustment.
Select this icon and add +0,5 or +1 or +1,5 dB to your
cursor with or button, to make it more closed to
white part than green part of bargraph when you do not
have ultrasounds. It will helps for small leak detection
(target will be more reactive to small ultrasounds). Valid
value with .
H. Bluetooth activation
Select this icon and put your headphones or your
speaker in pairing mode. Wait some seconds and it’ will
be OK.
I. Activation of K function (leak severity or estimation)
J. Escape icon to go back to measure mode.
—11 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

K,
HOW IT WORKS?
To activate K function , please select it in general
MENU. You can activate or deactivate it according
your need.
K,
CONDITION OF USE
Only for industrial compressed air (5 to 8 Bar (72
to 116 Psi)).
SET GAIN TO HAVE CURSOR BETWEEN DOTTED LINES
« DISTANCE BETWEEN LEAK AND CONE »
—12 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

K,
WITHOUT SETTINGS
LEAKSCORE NUMBER:
0 to 100, from very small to very big leakage
LEAKSCORE NUMBER:
0 to 100, from very small to very big leakage
5 colored levels:
•0-20 ;
•20-40 ;
•40-60 ;
•60-80 ;
•80-100
5 colored levels:
•0-20 ;
•20-40 ;
•40-60 ;
•60-80 ;
•80-100
(for about :
•0.2 m³/h;
•0.6 m³/h;
•3.5 m³/h;
•14.5 m³/h;
•31.7 m³/h)
+ Flow m³/h
+ Cost/year estimations
IF IN K MENU, SETTINGS ARE = « 0 » IF IN K MENU, SETTINGS ARE BOTH
DIFFERENT THAN « 0 »
++
Cost of 1x
Nm³
Cost of 1 Nm³
(is about 0,02 €)
Use per year Use per year
K,
WITH SETTINGS
—13 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

THERMAL CAMERA
(V3+PRO)
HOW IT WORKS?
Out of STRAPSHOOTER+® program
•(-10°C to +400°C range) with AUTO thermal imaging
mode
•Ɛ can be adjusted with and buttons
•Photo can be taken with 2x clicks on the PHOTO
button
and a name validated with Enter button on
the virtual keyboard
•To go back in ultrasound measurement mode,
click on keyboard button.
•Red cursor and blue cursor values are on the high and
low parts of the right vertical colored bargraph.
You can access to general settings of IR camera
under .
—14 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

In STRAPSHOOTER+®REAL TIME or AUTO mode, select
THERMAL icon and wait some seconds to have a stable
thermal image (wait after rst shutter activation):
•Take/freeze your trap thermal picture with the
PHOTO button .
•Select T° IN icon and valid it with to place
the T° IN cursor with joystick keyboard.
Valid it with .
•Select T° OUT icon and valid it with to place
the T° IN cursor with joystick keyboard.
Valid it with .
•Now you can save thermal image if necessary with the
Escape icon . Conrm or not.
•You can continue with your ultrasonic measurements.
•Do not forget to save all of your data at the end with
the SAVE icon to take your STEAM TRAP photo
and give it a name before nal storage in memory
(with Enter button on the virtual keyboard).
STRAPSHOOTER+®
(V3+PRO)
HOW IT WORKS?
STRAPSHOOTER+® is made for a combination of ultrasonic
and temperature measurements.
From main MENU, click on the STRAPSHOOTER+®keyboard
button :
•Choose between AUTO or REAL TIME modes.
Note: For mechanical ball oat trap, you need to nd
modulation in ultrasounds or sometimes cycles.
For thermodynamic or thermostatic, you will probably nd
cycles. If you have a low level and constant, it is probably a
closed situation and if you have a high level and constant,
it is probably an open leaking situation.
—16 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

STRAPSHOOTER+®
(V3+PRO) – REAL TIME
•Click on REAL TIME icon.
•Put your probe in contact with your trap.
•Click on START, choose your time period with
button, wait some seconds and look at your curve.
•If necessary, adapt GAIN and SCALE (settings) for high
level of ultrasounds (avoid saturation).
•Wait about STOP following chosen time period.
•Measure T°IN and T°OUT with thermal camera and
save results (SAVE icon ).
•You can save all data following instructions on screen.
Note: Blue curve is the REAL TIME ultrasonic noise in the
trap.
—17 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

STRAPSHOOTER+®
(V3+PRO) – AUTO
The STRAPSHOOTER+® algorithm will analyze T°IN, T°OUT
and ultrasound level and shape in the trap to give its condi-
tion result. Click .
The thermal camera will be automatically ON after some
seconds. You can adjust emissivity ε if necessary with UP
and DOWN buttons (0.90 per default). Freeze
thermal picture by clicking on PHOTO keyboard button .
Click on keyboard button and place T°IN cursor with
keyboard joystick. Valid with . Repeat the same for
T°OUT.
Click to valid Escape icon to save T°IN and T°OUT
values. You can also save thermal picture if necessary
or not .
When you are ready (contact probe on the trap), do not
move and click on keyboard button to START autogain
.
Then click on keyboard button to START measurement
. Choose duration time of analysis (common is 30 s).
Do not move with contact probe during measurement
and wait until STOP .
AUTO trap condition (*) result is given after 1 second.
You can SAVE or ESCAPE it.
If you SAVE, take trap picture by clicking on PHOTO key-
board button to freeze it and again to valid it. Go on
virtual keyboard to give a name to the le and valid it with
ENTER virtual keyboard button.
If you ESCAPE, program goes back to general STRAPSHOOTER+®
menu.
—18 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

(*) AUTO - TRAP
CONDITIONS :
means trap condition is OK.
It can be CYCLING or MODULATING.
means trap condition is NOT OK.
It can be BIG LEAK or CLOSED or TOO
FAST CYCLING or DROWNED
(or NOT IN SERVICE)
means trap condition is NOT OK but
UNKNOWN. You need to investigate.
—19 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide

MAIN ICONS USED
IN LEAKSHOOTER®
BLUETOOTH setting
(Headphones or speaker pairing)
Your use of compressed air / year
(8.760 h/year for 24h/24h use)
Frequency mixer setting
(42 kHz per default)
AUTO OFF setting
Your Nm³ compressed air cost
(for example 0.02 €).
Use # for special non standard money.
Clock & date settings
White LED light ON/OFF
Internal or external
probes
—20 —
SYNERGYS TECHNOLOGIES / LEAKSHOOTER ® / User Guide
This manual suits for next models
1
Table of contents
Other Synergys Security Sensor manuals
Popular Security Sensor manuals by other brands

Cobra
Cobra DSP 9200BT operating instructions

Siemens
Siemens UP 255D21 5WG1 255-2DB21 Operating and mounting instructions

Ksenia
Ksenia unum wls installation guide

ComMaster
ComMaster CM 9150 user manual

Bridgesecure Technologies
Bridgesecure Technologies Alarmster WFH500 user manual

McCue
McCue Pedestrian Barrier installation instructions