1.1 General Remarks 4
1.2 Copyright note 4
1.3 Contents of this Documentation 5
1.4 Items delivered 5
Built in versions 51.4.1
VESA mount version 51.4.2
1.5 Installation 5
1.6 Safety Recommendations and Warnings 5
1.7 EMC 5
1.8 Electro Static Discharge 5
1.9 Life Cycle Information 6
Transportation and Storage 61.9.1
Assembly and Installation 61.9.2
Operation 61.9.3
Maintenance and Repair 61.9.4
Disposal 61.9.5
1.10 Warranty 6
RoHS 71.10.1
WEEE 71.10.2
1.1 Explanation of Symbols 7
Danger warnings 71.1.1
Warnings indicate the following: 71.1.2
Information pictograms indicate the following: 71.1.3
2Product Description 8
2.1 Benefits of Syslogic`s Projected Capacitive Touch Monitor 8
2.2 Intended use 8
Variants 82.2.1
Intended use of Projected Capacitive Touch Monitors 82.2.2
2.1 Device Versions 9
2.2 Additional software products 9
2.1 Accessories 9
3Installation Guide 10
3.1 LVDS Monitor TFT/PxxxxPU-A101E 10
3.2 DVI Monitor TFT/PxxxxPU-A102E 10
3.3 Mounting 11
TFT/PBxxxPU-A102E 113.3.1
Mounting procedure TFT/PBxxxPU-A102E 12
Mounting procedure TFT/PVxxxPU-A102E 133.3.2
4Hardware Description 14
4.1 Features 14
HBxxxPU7F16-A101E 144.1.1
HBxxxPU7F16-A102E 144.1.2
HVxxxPU71x16-A102E 144.1.3

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 3 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
4.2 Dimensions 15
HBxxxPU71x16-xxx 154.2.1
HVxxxPU71x16-xxx 164.2.2
4.3 Interface Description 17
Power Supply 174.3.1
LVDS Interface (TFT/PxxxxPU-A101E only) 184.3.1
DVI Interface (TFT/PxxxxPU-A102E only) 184.3.1
USB Interface 194.3.2
Indication LED 194.3.3
Brightness control 194.3.4
Fuse 204.3.5
4.4 Internal connectors and configuration 21
Backlight connector 214.4.1
PIR and Brightness Sensor Interface (P12) 214.4.2
1.1.1. External Potentiometer connector (P13) 21
Programming interface 214.4.3
Shield Connection J200 224.4.4
4.5 Notes on the Touch Screen 22
Basic functions of the touch screen 224.5.1
Using OnScreenKeyboard (OSK) with Windows7 224.5.2
4.6 Cleaning the Projected capacitive touch panel 23
Cleaning the glas front 234.6.1
Cleaning the metal housing 234.6.2
5 23
6Programming Information 24
6.1 Overview 24
Raw HID Commands and responses 246.1.1
USB HID Raw Command Package 246.1.2
7Technical Data 25
7.1 General technical Data 25
7.2 EMI / EMC Specification 26
8Firmware 26
9Product Revision History 26
10 Manufacturer Information 27
10.1 Contact 27
List of Tables
Tab. 1 Disposal Materials 6
Tab. 2 Projected capacitive touch monitor versions 9
Tab. 3 Projected capacitive touch monitor accessories 9
Tab. 4 TFT/PBxxxPU-A102E Mounting dimensions 11
Tab. 5 PVxxxPU-A102E VESA dimensions 13
Tab. 6 PBxxxPU71-A102E dimensions 15

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 4 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
Tab. 7 HVxxxPU71x16-xxx dimensions 16
Tab. 8 Power supply connector P1 (1x4 pin) 17
Tab. 9 LVDS Connector 18
Tab. 10 DVI-D Connector Pin description 18
Tab. 11 USB Host Connector 19
Tab. 12 External USB Device Connector 19
Tab. 13 External USB Device Connector 21
Tab. 14 External USB Device Connector 21
Tab. 15 External potentiometer connector (P13) 21
Tab. 16 Shiled Connection J200 22
Tab. 17 Controller commands 24
Tab. 18 USB Hid write command message 24
Tab. 19 General Absolute Maximum Ratings 25
Tab. 20 General Recommended Operating Conditions 25
Tab. 21 Maximum Cable length 25
Tab. 22 Firmware revisions 26
Tab. 23 Hardware Revision State 26
List of Figures
Fig. 1 LVDS Monitor System Setup 10
Fig. 2 LVDS Monitor System Setup 10
Fig. 3 HBxxxPU71x16-A101E 14
Fig. 4 HBxxxPU71x16-A102E 14
Fig. 5 HVxxxPU7F16-A102E 14
Fig. 6 Brightness Adjust TFT/BVxxxPU-A10xE Fig. 7 Brightness adjust (TFT/BVxxxPU-A10xE) 19
Fig. 8 Open side view with Reset button, battery and Cfast 20
Introduction
1.1 General Remarks
The content and presentation of this document has been carefully checked. No responsibility is accepted for any errors or omissions in the
documentation.
Note that the documentation for the products is constantly revised and improved. The right to change this documentation at any time without
notice is therefore reserved.
Syslogic is grateful for any help referring to errors or for suggestions for improvements.
1.2 Copyright note
This documentation is the intellectual property of Syslogic Datentechnik AG, which also has the exclusive copyright. Any modification of the
content, duplication or reprinting of this Documentation, as well as any distribution to third parties can only be made with the express
permission of Syslogic Datentechnik AG.
Syslogic Datentechnik AG does not accept any liability for damages arising from the use of any incorrect or incomplete information contained
in this documentation or any information missing.
All brand and product names are trademarks or registered trademarks of the owner concerned.

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 5 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
1.3 Contents of this Documentation
This document addresses to system integrators, programmers and instructed installation and maintenance personal working with the system. It
provides all information needed to set-up, mounting, start-up an operation of this device.
1.4 Items delivered
Built in versions1.4.1
The device is delivered with the following equipment
-1x TFT/PBxxxPU-A102E
-1x Fixing Frame with M4x20 securing screws
-1x Power supply connector
VESA mount version1.4.2
-1x TFT/PVxxxPU-A102E
-1x Power supply connector
-4x M4x8 securing screws for VESA100 mounting
1.5 Installation
The installation of the system is described in this documentation. Refer to chapter 3
1.6 Safety Recommendations and Warnings
The product is intended for measurement, control and communications applications in industrial environments. The products must be installed
by specially trained people. The strict observation of the installation guideline is mandatory.
The use of the product in systems in which the life or health of persons is directly dependent (e.g. life support systems, patient monitoring
systems, etc.) is not allowed.
The use of the product in potentially explosive atmospheres requires additional external protection circuitry which is not provided with the
product.
In case of uncertainty or of believed errors in the documentation please immediately contact the manufacturer (address see chapter 10). Do
not use or install the product if you are in doubt. In any case of misuse of the product, the user is solely liable for the consequences.
1.7 EMC
Important note
This is a Class A product and not intended to be used in domestic environments. The product may cause
electromagnetic interference. Appropriate measures must be taken.
1.8 Electro Static Discharge
Important note
Electronic boards are sensitive to Electro-Static Discharge (ESD). Please ensure that the product is handled with care
and only in a ESD protected environment. Otherwise a proper operation is not guaranteed.

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 6 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
Electronic boards are sensitive to Electro-Static Discharge (ESD). Please ensure that the product is handled with care and only in a ESD
protected environment. Otherwise a proper operation is not guaranteed.
1.9 Life Cycle Information
Transportation and Storage1.9.1
During transportation and storage the product must be in the original packing. It is recommended, to keep the original packing in case of
return of the product to the factory for repair. Note that the packing is recyclable.
Assembly and Installation1.9.2
Observe the EMI-precautions against static discharge. Carefully read the installation documentation before unpacking the product.
The installation procedures must be strictly observed. Note that deviations from the installation guidelines may result in degraded operational
reliability or in unfavourable EM-radiation or EM-susceptibility.
Operation1.9.3
The operating environment must guarantee the environmental parameters (temperature, power supply, etc.) specified in the technical
specification section of this document.
The main functionality of the product is defined by the application programs running. The application programs are not part of the delivery by
Syslogic but are defined, developed and tested by the customer or a system-integrator for each specific application. Refer to the respective
documentation for more information.
Maintenance and Repair1.9.4
In the rare case of a product hardware-failure or malfunction, the complete product should be exchanged. The faulty product must be returned
to the factory for repair. Please use whenever possible the original packing for return of the product (EMI and mechanical protection).
Disposal1.9.5
At the end of the lifespan product must be properly disposed. The product contains a multitude of elements and must be disposed like
computer parts. Packaging not needed anymore must be fairly disposed or be returned for disposal to the manufacturer or distributor. The
wrapping contains the following materials: Cardboard box and transportation protection.
Materials
Description
Front Glas
Safety glas
Front Touch
Glas, Plastic, Copper
Front frame
Metal /AlMg 4.5 Mn)
Hoods
Galvanized sheet steel
Mounting plates
Galvanized sheet steel
Display LED
1 Disposal qualitiy
Print boards
1 Disposal quality
Tab. 1 Disposal Materials
1.10 Warranty
Our products are covered by a world-wide manufacturer’s warranty. The warranty period starts at the delivery time from our official distributor
to the customer. The duration of the warranty period is specified in the respective product catalogues and the offers. All products carry a date
code and a job number for identification. The manufacturing data and deliveries are registered in a high level Quality Management System.
The warranty covers material and manufacturing defects. All products must be returned via the official distributor to the factory for repair or
replacement. The warranty expires immediately if the products are damaged of operation outside of the specified recommended operating
conditions. The warranty also expires if the date code or job number listed on the product is altered or rendered unintelligible. The warranty
does not include damage due to errors in firmware or software delivered with the products.

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 7 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
RoHS1.10.1
The product of the IPC/NETIPC-6 family are designed and produced according to the Restriction of Hazardous Substances (RoHS) Directive
(2002/95/EC).
WEEE1.10.2
The products of the IPC/NETIPC-6 are not designed ready for operation for the end-user and intended for consumer applications. Therefore
the Waste Electrical and Electronic Equipment (WEEE) Directive (2002/96/EC) is not applicable. But users should still dispose the product
properly at the end of life.
1.1 Explanation of Symbols
Danger warnings1.1.1
The following information is for your personal safety and the prevention of damage to the product described or connected devices.
Safety instructions and warnings for the prevention of danger to the life and health of users or service personnel, and for the prevention of
damage are highlighted in this document by the pictograms specified below. “Warning” and “Information” pictograms are shown in this
document.
Warnings indicate the following:1.1.2
Death, serious injury or substantial material damage may occur if the related safety measures are not implemented.
The individual “Warning” pictograms have the following meaning:
Attention! General!
Is an instruction that must be observed in order to ensure protection before, while and after using the device. The
correct procedure must be observed.
Attention! Electric shock!
Persons may be exposed to dangerous voltages in electrical installations.
There is a danger of electric shock if a live part is touched.
Attention! Observe ESD measures!
Electrostatic discharge may destroy electronic components.
Information pictograms indicate the following:1.1.3
Important information about the product or the relevant section of the document, requiring the particular attention of the reader.
The “Information” pictogram has the following meaning:
Indicates important and instructional information.

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 8 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
2Product Description
2.1 Benefits of Syslogic`s Projected Capacitive Touch Monitor
–Different screen sizes
–Robust touch screen technology
–Front protection to IP65
The product meets all the requirements of state-of-the-art advanced touch monitors.
The product is a rugged information display and input device that is specially developed for operation in harsh environments.
The TFT technology makes a wide range of applications possible with a perfect and clear picture on an absolutely flat surface.
The absolutely flat PCT (Projected capacitive Touch) touch panel offers the latest Dual-Touch technology. PCT Touch Screen can be used with
fingers or with special capacitive touch gloves or pens/stylus. Calibration of the touch screen can be easily made with the Touch driver software
described in chapter 2.4.
A metal housing with a solid front frame and scratch resistant safety glass protects the device
Reliably during long and rugged periods of use (front protection: IP65) and requires little careand maintenance.
2.2 Intended use
The products are intended for measurement, control and communications applications in industrial environments. The products must be
assembled and installed by specially trained people. The strict observation of the assembly and installation guidelines is mandatory.
The use of the products in systems in which life or health of persons is directly dependent (e.g. life support systems, patient monitoring
systems, etc.) is not allowed.
The use of the products in potentially explosive atmospheres requires additional external protection circuitry which is not provided with the
products.
In case of uncertainty or of believed errors in the documentation please immediately contact the manufacturer (address see chapter 10). Do
not use or install the products if you are in doubt. In any case of misuse of the products, the user is solely liable for the consequences.
Ensure that the power supply is disconnected from the device before working on the device (connecting interfaces, replacing flash cards,
batteries, opening the enclosure, etc.).
Please read the safety instructions of the power supply before installing/connecting the device.
Variants2.2.1
Syslogic provides two interface variants within the PROTOUCH Monitor Series.
LVDS Monitors
The LVDS Interface uses an FPD2 Link interface. In addition USB is transmitted on the same cable. This variant is intended for minimal system
wiring effort. Therefore there is only one cable used to connect the host device with the monitor to provide full functionality.
DVI Monitors
DVI Monitors are designed for maximum flexibility and compatibility to standard computer interfaces. The DVI monitors require an USB and a
DVI cable to connect the host device with the monitor.
Intended use of Projected Capacitive Touch Monitors2.2.2
The Projected Capacitive Touch Panel is designed for:
–Visualization and process control
–PLC visualization
–General control and automation tasks
–Industrial use
–For medical technology
–For multi-media systems

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 9 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
–Operation in the ambient conditions specified in the technical data
This device description is designed as a reference guide for the installation, connection,
Operation and maintenance of all versions of the Projected Capacitive Panel, and also provides all the relevant technical data.
2.1 Device Versions
The Projected capacitive touch panels are available in the following versions:
Order code
Flat screen
Mounting type
Display connection
TFT/PB104PU-A101E
10.4” XGA
Flush mounting
LVDS
TFT/PB104PU-A102E
10.4” XGA
Flush mounting
DVI-D
TFT/PB121PU-A102E
12.1” XGA
Flush mounting
DVI-D
TFT/PB150PU-A102E
15.0” XGA
Flush mounting
DVI-D
TFT/PV121PU-A102E
10.4” XGA
VESA mounting
DVI-D
TFT/PV150PU-A102E
12.1” XGA
VESA mounting
DVI-D
TFT/PV104PU-A102E
15.0” XGA
VESA mounting
DVI-D
Tab. 2 Projected capacitive touch monitor versions
2.2 Additional software products
2.1 Accessories
The following accessories are not necessarily supplied with the device. These parts could be ordered additionally or downloaded from
www.syslogic.com:
Accessories
Type designation
Description
Touch driver software
Touch driver software for Windows 9x / Me / 2000 / XP / 7 / Embedded
Monitor driver software
Monitor configuration tool to configure the device. (Windows/Debian)
PIR and Brightness Sensor
Additional Brightness sensor to automatically adjust the Brightness of the backlight and a Motion
Sensor to disable the display if nobody is watching.
Tab. 3 Projected capacitive touch monitor accessories

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 10 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
3Installation Guide
3.1 LVDS Monitor TFT/PxxxxPU-A101E
Make sure you are aware of the safety instructions of this manual.
Connect a power supply 24V to the power connector and the host.
Connect the display port of the host and the monitor using a special LVDS cable. (Max 5m)
Connect shield
Power up the device.
Fig. 1 LVDS Monitor System Setup
3.2 DVI Monitor TFT/PxxxxPU-A102E
Make sure you are aware of the safety instructions of this manual.
Connect a power supply 24V to the power connector.
Connect the Display connector to a computer (host) using a DVI cable.
Connect the USB B connector to the USB Port of the computer (host).
Connect shield
Connect any peripheral device to the USB Hub if required.
Power the host computer and the monitor.
Fig. 2 LVDS Monitor System Setup
Power supply
Monitor
DVI Cable
Host
Power supply
Monitor
LVDS Cable
Host
USB Cable

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 11 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
3.3 Mounting
TFT/PBxxxPU-A102E3.3.1
The desired mounting place must have a cut out and wall thickness regarding the following overview.
Front cut out dimensions
Edge radius
Wall thickness
Device #
W [mm]
H[mm]
R [mm]
D [mm]
TFT/PB104PU-A102E
271 -0/+2
217 -0/+2
Max. 3mm
1 to 7
TFT/PB121PU-A102E
316 -0/+2
258 -0/+2
TFT/PB150PU-A102E
378 -0/+2
295 -0/+2
Tab. 4 TFT/PBxxxPU-A102E Mounting dimensions
Mounting Angle: Mounting Angle must be 90°
Cooling Space: To ensure cooling leave at least 10cm of free space around product.
W
H
R
R
R
R
D

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 12 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
Mounting procedure TFT/PBxxxPU-A102E
Remove the screws highlighted in red and then remove the mounting frame.
The seal is delivered separately. Please insert the seal in the groove on the backside of the front. The ends of the seal must fit tight
together for a perfect sealing.
Insert the projected capacitive touch panel from the front into the cut out and make sure that the sealing fits properly.
Reattach the mounting frame and fix it into place by reattaching the screws highlighted in red.
The product is now installed properly.
Wall
Projected capacitive touch panel

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 13 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
Mounting procedure TFT/PVxxxPU-A102E3.3.2
All TFT/PVxxxPU-A102E are equipped with a VESA100 (100x100mm) mounting system delivered with M4x8 Philips screws.
Screw hole deepness is 7mm. The screw must fit at least 5mm into the screw holes.
Device #
X [mm]
W [mm]
H [mm]
TFT/PV104PU-A102E
100
89
74
TFT/PV121PU-A102E
100
111.5
102
TFT/PV150PU-A102E
100
142.5
139
Tab. 5 PVxxxPU-A102E VESA dimensions
Mounting Angle: Mounting Angle must be 90° ± 15°
Cooling Space: To ensure cooling leave at least 10cm of free space around product.
X
X
W
H

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 14 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
4Hardware Description
4.1 Features
HBxxxPU7F16-A101E4.1.1
Fig. 3 HBxxxPU71x16-A101E
HBxxxPU7F16-A102E4.1.2
Fig. 4 HBxxxPU71x16-A102E
HVxxxPU71x16-A102E4.1.3
Fig. 5 HVxxxPU7F16-A102E
DISPLAY
connector
LED
Shield Contact
4 USB Ports (Downstream)
USB Port (Upstream)
Display with Touch
Sensor
Mounting frame
Power connector
DISPLAY
connector
LED
Shield Contact
4 USB Ports (Downstream)
Display with Touch
Sensor
Mounting frame
Power connector
LED
DISPLAY
connector
Shield Contact
4 USB Ports (Downstream)
USB Port (Upstream)
Display with Touch
Sensor
Power connector

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 15 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
W
H
4.2 Dimensions
HBxxxPU71x16-xxx4.2.1
Device #
W
[mm]
W1
[mm]
W2
[mm]
H
[mm]
H1
[mm]
H2
[mm]
D1
[mm]
D2
[mm]
TFT/PB104PU-A102E
288
30
31
234
31
71.5
52.5
22
TFT/PB121PU-A102E
333
52.6
53.6
275
31
112
52.5
22
TFT/PB150PU-A102E
395
84.7
83.7
312
31
150.7
54.5
24
Tab. 6 PBxxxPU71-A102E dimensions
D2
D1
H1
H2
H
W
W1
1mm gap between
mounting frame and
front all around the
display
W2

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 16 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
HVxxxPU71x16-xxx4.2.2
b
Device #
W
[mm]
W1
[mm]
W2
[mm]
H
[mm]
H1
[mm]
H2
[mm]
D1
[mm]
D2
[mm]
D3
[mm]
TFT/PV104PU-A102E
279
15
15
224
14
39,5
62
24.5
8.5
TFT/PV121PU-A102E
324
26.5
26.5
266
15
67.5
62
24.5
8.5
TFT/PV150PU-A102Eb
386
57.5
57.5
303
15
104.5
65
27.5
8.5
Tab. 7 HVxxxPU71x16-xxx dimensions
D3
D2
D1
H
W
H1
H2
W1
W2
Front frame all around
the device with 2.5mm

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 17 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
4.3 Interface Description
Power Supply4.3.1
The processor and its peripherals are powered by a non-isolated, integrated power supply which generates all internal voltages.
Power Supply requirements:
The power supply used must fulfil surge protections according to the application.
Always use a short circuit protected power supply.
Do not use power supplies wires or cables longer than 3m.
The device uses a connector Weidmüller SC-SMT 3.81/04/90 LF RL (186398000).
A mating connector Weidmüller BCZ 3.81/04/180F SN SW (1792970000) is delivered with the device.
Pin
Signal
Marking
Remarks
1
+24VDC_AUX
VAUX
Additional, permanent power supply
2
Fail/Remote on/off
PF
Power fail input
3
+24VDC
VDC
+10V..+30V
4
GND
GND
GND (/shield)
Tab. 8 Power supply connector P1 (1x4 pin)
For normal operation the external power supply has to be connected to the pins 3 (+24VDC)
and 4 (GND) of the connector P1.
Pin 1 (+24VDC_AUX) is used to extend battery life time if the device main power is disabled.
Pin 2 is used as an input for either a power fail on remote on/off signal.
Power supply requirements
minimal power: 30W
voltage range: 15…30Vdc
efficiency > 88%
integrated over-current limitation
compliant with the directives 2004/1008/EC (EMC) and 2006/96/EC (LVD)
compliant with the standards EN 61000-6-1, EN 61000-6-2, EN 61000-6-3 and EN 61000-6-4, FCC Part 15 Class B
compliant with EN 60950-1
Syslogic recommends the use of the Syslogic DIN Rail power supply
PSU/DR24V60W
(input voltage: 230Vac, output voltage: 24Vdc,
power: 60W)
.
Please make sure that the input voltage does not exceed 30V otherwise the base board could get damaged. If the input voltage
drops below 10V the system doesn’t work properly, correct operation cannot be guaranteed.
Important notes
Please read the safety and installation instructions of the power supply before connecting it to the monitor.
If connecting additional devices to the power supply the specified maximum power must not be exceeded.
1
4

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 18 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
LVDS Interface (TFT/PxxxxPU-A101E only)4.3.1
This RJ45 connector carries the LVDS signals as well as the USB interface.
Pin number
Signal
Remarks
1
FPD-Link2 -
2
FPD-Link2 +
3
GND
Ground
4
Reserved
Not used
5
Reserved
Not used
6
VUSB
5V USB Supply
7
D-
USB Data
8
D+
USB Data
Tab. 9 LVDS Connector
DVI Interface (TFT/PxxxxPU-A102E only)4.3.1
This is the display data input interface. Connect this connector to a computer or other source using a DVI-D (single link) cable. Make sure the
selected display resolution of the sorurce device corresponds with the product.
PIN
Description
Remark
Pin
Description
Remark
Pin 1
TMDS data 2+
Digital red
Pin 16
Hot plug detect
Hot plug detect
Pin 2
TMDS data 2+
Digital red+
Pin 17
TMDS data 0−
Digital blue−
Pin 3
TMDS data 2/4
shield
Pin 18
TMDS data 0+
Digital blue+
Pin 4
TMDS data 4
Not connected
Pin 19
TMDS data 0/5
shield
Pin 5
TMDS data 4
Not connected
Pin 20
TMDS data 5−
Not connected
Pin 6
DDC clock
Pin 21
TMDS data 5
Not connected
Pin 7
DDC data
Pin 22
TMDS clock shield
Pin 8
A. vertical sync
Not connected
Pin 23
TMDS clock+
Digital clock+
Pin 9
TMDS data 1−-
Digital green−
Pin 24
TMDS clock−
Digital clock−
Pin 10
TMDS data 1+
Digital green+
C1
Analog red
Not connected
Pin 11
TMDS data 1/3
shield
C2
Analog green
Not connected
Pin 12
TMDS data 3-
Not connected
C3
Analog blue
Not connected
Pin 13
TMDS data 3+
Not connected
C4
A. horizontal sync
Not connected
Pin 14
+5 V
5V Supply
C5
Analogue ground
Not connected
Pin 15
Ground
Ground
Tab. 10 DVI-D Connector Pin description

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 19 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
USB Interface4.3.2
The USB interface has an internal USB hub providing the following functionalities:
The monitor controller interface is implemented as USB-HID device and can be controlled either with the configuration tool or
directly using the USB-HID interface. The monitor controller interface provides functions to set the brightness of the device or to
disable the backlight.
The touch controller is implemented using an EETI eGalay Touch Controller. Basic functionality is supported from most operating
system without any additional tools or drivers. To use extended features of the controller use EETI eGalaxTouch software.
Connection to four external (USB A) and one internal USB 2.0 Ports to be used for any USB device.
USB Host Connector (Type: USB B) (TFT/PxxxxPU-A102E only)
Pin number
Signal
Remarks
1
VddUSB
5V supply
2
D-
Data signal -
3
D+
Data signal +
4
GND
GND (/shield)
Tab. 11 USB Host Connector
External USB device connector (Type: USB A)
Pin number
Signal
Remarks
1
VddUSB
5V supply (max 500mA)
2
D-
Data signal -
3
D+
Data signal +
4
GND
GND (/shield)
Tab. 12 External USB Device Connector
Indication LED4.3.3
The device has two LED indicating the following state:
Red: Device not ready (start up, over current or over temperature or general error)
Green: Device OK
Brightness control
4.3.4
The Brightness can be controlled using the USB interface. Refer to the software manual to adjust the brightness of the monitor.
The Brigthness can be adjusted using the potentiometer on the rear of the panel. For VESA Monitors the service cover has to be removed. For
built in Monitors the Potentometer is available from the outside.
Fig. 6 Brightness Adjust TFT/BVxxxPU-A10xE Fig. 7 Brightness adjust (TFT/BVxxxPU-A10xE)
Turn it to the left to increase or turn it to the right to decrease the brightness of the monitor. Use the USB interface to configure the
potentiometer as the source of the brightness control.

Artikelcode: user documentation
DOC/PROTOUCH-MONITOR; V1.1
DOC_PROTOUCH_M-E.docx Seite 20 von 27
© 2016 Syslogic Datentechnik AG | All rights reserved
Fuse4.3.5
The onboard fuse prevents the destruction of the product in cause of a malfunction. The fuse must be replaced by an instructed
person/technician and in an ESD protected environment. The fuse F600 is located next to the power connector on the PCB.
1. Make sure that the device is not connected to a power supply!
2. Remove screws
Flush mounting versions Vesa Mounting versions
3. Remove the cover of the case.
4. Carefully remove the fuse with a pair of tweezers or needle-nosed pliers.
Fig. 8 Open side view with Reset button, battery and Cfast
Type for F1701: Littlefuse Nano2Slo-Blo 3A: 0452.003MRL
Please note that in the code above the package code for tape and reel and quantity 1000pcs is included.
For further information on how to replace the battery please contact the manufacturer.
F1701: Littlefuse Nano2Slo-Blo 3A
Ordercode: 0452.003MRL
This manual suits for next models
18