System air X-RS485 User manual

RS485Gateway
Wireless
UserManual
-en_GB
Documentinoriginal
language2017-03-20A005

Contents
1DeclarationofConformity...............................1
2Productdescription......................................3
3Guidelinesforinstallation...............................4
4Interfacedescription.....................................5
4.1Connections.......................................6
4.2Power-up..........................................9
4.3Active/User/Faultmode..........................9
4.4Bindingmode.....................................11
5CommunicationInterfaceFunctions...................12
5.1Power-UpandResetOperation.................12
6Troubleshooting..........................................13

1DeclarationofConformity
Manufacturer
SystemairAB
Industrivägen3
SE-73930SkinnskattebergSWEDEN
Ofce:+4622244000Fax:+4622244099
www.systemair.com
herebyconrmsthatSmartDial,CO2sensor,Humidity
sensor,InputmoduleandRS485Gatewaycomplywithall
applicablerequirementsintheDirective2014/53/EU.
TheunitswillmeettherequirementsoftheWEEEandROHS
directives.
RS485GatewayUserManual
1SystemairAB

Thecompletetechnicaldocumentationisavailable.
Skinnskatteberg,20-03-2017
MatsSándor
TechnicalDirector
RS485GatewayUserManual
2SystemairAB

2Productdescription
TheRS485gatewayisawirelessgatewaybetweenthe
Systemairairhandlingunitandwirelessremotemodules.The
communicationfrequencyis868.3MHz
Thewirelessremotemodulessuchas:SmartDial,Input
Module,HumiditysensorandtheCO2sensorareall
wirelesslyconnectedtotheRS485gateway.Noneofthe
remotemodulesworkswithoutthegatewayinstalled.Up
to10wirelessremotemodulescanconnecttothegateway
simultaneously.
TheRS485gatewayisintendedforwallmountingeitheron
thewalloronawall-box.
Note:
Nointernalparametersorsettingscanbechangedbythe
user.
RS485GatewayUserManual
3SystemairAB

3Guidelinesforinstallation
Thesignalstrengthissufcientformostapplications,however,
wirelesssignalsareweakenedonthewayfromthegateway
tothedifferentwirelessmodules.Eachbuildinghasdifferent
obstaclestobetakenintoconsideration.
DonotmounttheRS485gatewaydirectlyontheairhandling
unitsincethesheetmetalchassiscaninterferewiththeradio
communication.
Ensurethebestperformancebykeepingthefollowinginmind
forplanningandinstallation:
•Min.1mandmax.30mbetweendevicesinfreespace.
•Allmetallicpartsinthebuildingconstructioncanweaken
wirelesssignals.
•Reinforcedconcretewallsandoorsweakenthesignal
strengthsignicantly,butalmostalltypesofconstruction
materialsreducethesignaltosomedegree.
RS485GatewayUserManual
4SystemairAB

Note:
Togetagoodoverviewofthedevicesineachrooms,and
theirplacement,Systemairrecommendsthataninstallation
planismadebeforebeginningtheactualinstallation.
4Interfacedescription
Thegatewayissendingandreceivingdatawirelesslytothe
remotemodulesandiswiredviaanRS485bustotheair
handlingunit.
TheManMachineInterface(MMI)forthisproductconsistsof
abuttonandtwoLEDindicators.Onered(thelower)andone
green(top)LEDthatindicatesthestatusofthegateway.
RS485GatewayUserManual
5SystemairAB

1.GreenandRedstatusLED’s.
2.Functionbutton
4.1Connections
TheSystemairairhandlingunitandtheRS485Gatewayare
interconnectedbyacable:
•Maximumcablelength:50m.
•Cabletype:Flat4–conductorCECPhonecable,or
equivalent.
Thegatewayispoweredbytheairhandlingunit.
RS485GatewayUserManual
6SystemairAB

Screw/Ter-
minal
FunctionColouredconnection
cable(#208263)
1(A)RS485Ayellow
2(G)GND(shielding)black
RS485GatewayUserManual
7SystemairAB

3(B)RS485Bgreen
4(P)Powersupply(5VDC
/24VAC)
red
Externalconnectionsontheairhandlingunit.
1.Cableglands
2.ConnectiontoDI3
throughanon/offswitch
3.Connectiontocontrol
paneland/orRS485
Gateway
Connectthecableto(3)ontheairhandlingunit.Ifacontrol
panelisalreadyconnectedto(3),adivertingplugcanbeused
toenableconnectionofbothagatewayandthestandard
controlpanel.
RS485GatewayUserManual
8SystemairAB

4.2Power-up
Afterthegatewayhasbeenturnedon,thegreenLEDlights
up.
After2seconds,thegatewaywillgotoidlemode.
Inidlemode,thestatusLED’sareturnedoff.
WhenthebuttonispushedtheActive/User/Faultmodeis
entered.
4.3Active/User/Faultmode
IntheActive/User/Faultmode,theLED’scanshowthe
followingstatus:
RS485GatewayUserManual
9SystemairAB

IndicationStatus/Function
GreenLED
continuouslylit
SystemOK.
GreenLEDashing
for3seconds
Remotemodulecanstartsending
bindrequests.
RedLEDashingNowirelesscommunication
betweenremotemoduleand
gatewayorremotemodulenot
connected.
•Flashingred(fault).Thisstatusisrepeatedeveryfew
seconds.
•Whenthebuttonispressedandheldfor10seconds,the
greenLEDstartsashingfor3seconds.
•Ifthebuttonisreleasedwithinthese3seconds,the
bindingmodeisentered.
•Ifthebuttonisnotreleasedwithinthese3seconds,the
LEDgoesoffandthegatewaywillgotoidlemode.
RS485GatewayUserManual
10SystemairAB

•Ifthebuttonisnotpressedforatleast10seconds,the
gatewaywillgotoidlemode.
4.4Bindingmode
Inthebindingmode,theremotemodulescontactsthe
gatewayandrequestsconnection.
Inthebindingmode,theredandgreenLED’sarealternately
litandabindrequestmessagefromaremotemodulecanbe
received.Ifamessagefromaremotemoduleisreceivedand
accepted,thegatewaystaysinbindingmodeforanadditional
5minutes.Thegatewaywillacceptadditionalrequestsfrom
remotemoduleswithoutpressingthebuttonagain.
Ifnobindrequestmessageisreceivedfor5minutes,theidle
modeisentered.
Whenthebuttonispressedagain,theActive/User/Faultmode
isentered.
RS485GatewayUserManual
11SystemairAB

5CommunicationInterfaceFunctions
5.1Power-UpandResetOperation
Allremotemodulesanddigitalinputsaremarkedasinvalid
afterPower-Up.Ifanewvalueisreceived,thisvalueisstored
inthegateway.
Toresetthegatewaytofactorysettingsandhenceclearthe
bindingwithallremotemodules:
•PushtheFunctionbuttonandholditfor30seconds.The
greenLEDstartsashingrapidlyfor5seconds.
•Ifthebuttonisreleasedwithinthese5secondsthereset
operationisentered.
•Ifthebuttonisnotreleased,theLEDgoesoffandthe
gatewaywillgotoidlemode.
RS485GatewayUserManual
12SystemairAB

6Troubleshooting
IndicationProbablecauseandaction
Gatewaydoesnot
start.
LED’sdoesnotlight
up.
Wiringproblems.Checkwiring.
LED’slightup.Red
LEDashing.
Communicationproblems.
1.Remotemodulenotconnected.
—CheckACpowerorbatteriesinremote
module(dependingonmoduletype)
2.RemotemoduleconnectedbutredLED
stillashing.
—Othermodulesnotpowered.Check
batteriesinothermodules.
—Distancebetweengatewayandremote
modulestoofar.Max30m.
Reviseplacementoftheequipment.
—Metallicpartsorotherreecting
materialsinthebuildingconstruction.
Reviseplacementoftheequipment.
RS485GatewayUserManual
13SystemairAB

lastpage
SystemairABreservestherighttomakechangesandimprovements
tothecontentsofthismanualwithoutpriornotice.
SystemairAB
Industrivägen3
SE-73930Skinnskatteberg,Sweden
Phone+4622244000
Fax+4622244099
www.systemair.com
This manual suits for next models
2
Table of contents
Other System air Gateway manuals
Popular Gateway manuals by other brands

Grandstream Networks
Grandstream Networks GXW-4004 user manual

CheckVideo
CheckVideo G1002-16-XT quick start guide

ZIGBEE
ZIGBEE IH-K008 product manual

AudioCodes
AudioCodes Gateway & Session Border Controller Series Hardware installation manual

NETGEAR
NETGEAR DSL VVG2000 user guide

Icotera
Icotera i6800 user guide