System air Fantech HEPA Series User manual

CM3000 • CM3000i
Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
United States 800.747.1762
Canada 800.565.3548
HEPA Series
Whole House Filtration Unit
Installation and Operation Manual
Item #: 401482
Rev Date: 2019-12-01
PARTS IN THE BOX (CM 3000)
Filtration Unit, 1 pc
Uninsulated 8" flex (UL listed) Duct, 2 pcs
8" Round Port Collar, 4 pcs
Hanging Chains & Hardware Kit, 1 pc
Operation and Installation Manual, 1 pc
PARTS IN THE BOX (CM 3000i)
Filtration Unit, 1 pc
8" Round Port Collar, 2 pcs
Hanging Chains & Hardware Kit, 1 pc
Operation and Installation Manual, 1 pc
registration.fantech.app
REGISTER THIS PRODUCT TO
BE REMINDED OF SUGGESTED
PRODUCT CARE SCHEDULE
Your Fantech HEPA Filtration system should
be installed in conformance with the appro-
priate local, provincial or state requirements
or in the absence of such requirements with
the current edition of the National Building
Code, and / or ASHRAE’s “ Good Engineering
Practices”.

2
fantech
Note Warning/
Important
note
Information Technical
information Practical tip
PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT
Before installation, careful consideration must be given to how this system will operate if connected to any other
piece of mechanical equipment, i.e. a forced air furnace or air handler, operating at a higher static pressure.
Products are designed and manufactured to provide reliable performance, but they are not guaranteed to be 100%
free of defects. Even reliable products will experience occasional failures, and this possibility should be recognized
by the user. If these products are used in a life support ventilation system where failure could result in loss or injury,
the user should provide adequate back-up ventilation, supplementary natural ventilation or failure alarm system, or
acknowledge willingness to accept the risk of such loss or injury.
Your Fantech HEPA Filtration system should be installed in conformance with the appropriate local, provincial or
state requirements or in the absence of such requirements with the current edition of the National Building Code,
and / or ASHRAE’s “ Good Engineering Practices”.

3
fantech
Table of content
INTRODUCTION..............................................................................4
DIMENSIONS ...............................................................................4
SPECIFICATIONS .............................................................................4
OPERATION ................................................................................4
INSTALLATION ..............................................................................5
CM 3000 – Uninsulated model
Option A.......................................................................5
Option B.......................................................................5
Option C.......................................................................5
Option D.......................................................................6
CM 3000 I – Insulated model
Option A.......................................................................7
Option B.......................................................................7
Option C.......................................................................8
Option D.......................................................................8
Whole House – Connecting a ventilation system (HRV/ERV) to HEPA system ...........................9
SERVICE .................................................................................10
FILTER REPLACEMENT .......................................................................10
MAINTENANCE SCHEDULE ....................................................................11
PARTS LIST ...............................................................................24

4
fantech
Introduction
HEPA Air Filtration Systems
You have purchased a very effective air cleaning and treatment system incorporating HEPA (High Efciency Particulate Arrestance) lter technology.
This is the type of air cleaning equipment that respiratory specialists recommend most. To optimize the performance of your HEPA Filtration System, it
should be installed by a professional contractor who is familiar with your indoor air quality situation and the operation of other heating, ventilation and
air conditioning equipment that you may have.
Two Units to Choose From
The Fantech HEPA Filtration system is available in two different models, depending on your choice of installation. Typically the CM 3000 is used in
geographical locations where the HEPA unit can be installed in a conditioned space such as a basement, closet or heated crawl space, (Example on
page 5 & 6). The CM 3000 I (Insulated version) is normally installed in the southern U.S. states where it's common to locate the HVAC equipment in an
unconditioned space such as a garage or attic (Example on pages 7 & 8).
Dimensions
A semi-annual service schedule must be followed to ensure the HEPA unit is operating at its full potential.
A
B
E
C D
F
Model A B C D E* F
Duct Size
Voltage Amp Delivery
in mm in mm in mm in mm in mm in mm V Amps cfm
CM 3000 16 1/4413 20 508 10 11/16 420 2 1/456 16 1/2410 8 203 115/V1/60 1 240
CM 3000 I 16 1/4413 20 508 10 11/16 420 2 1/456 16 1/2410 8 203 115/V1/60 1 240
Air In
Air Out
3" Cord- 3 Prong Plug
Front
Side
Back
Specifications
* Clearance required for servicing the unit
The CM3000I has 1/4" insulation all around the unit.
Model CM 3000 (uninsulated)
Insulated skin can be purchased separately and installed in the eld if required
Kit (included): – Two pcs. of uninsulated 8" ex (UL Listed)
– Four 8" round port collar
– Hanging Chains and hardware
– Installation manual
Model CM 3000 I (insulated)
Unit (included): – Two 8" round port collar
– Hanging Chains and hardware
– Installation manual

5
fantech
Operation
Your Fantech HEPA ltration system incorporates three stages of ltration. Air is drawn from the house via one of the installation examples, found
in this manual, by a powerful efcient EBM fan. The air is cleaned as it passes through the lters, where it is then reintroduced back into the home,
cleaned of the majority of harmful particles.
A semi-annual service schedule must be followed to ensure the HEPA unit is operating at its full potential.
Installation
CM 3000 - Uninsulated model
Option A & B
* Diagrams are examples only. Actual installation may vary.
The return side of the furnace is the recommended location for the HEPA to connect to. The supply side is normally avoided due to the higher static
pressure.
Furnace fan should operate continuous or when HEPA unit is on and running. (Options A & B)
Option C
* Diagrams are examples only. Actual installation may vary.
Duct work can be concealed in walls or closets. If the floor is the only choice, special care should be taken to avoid noise or drafts.
Air Return
Option A Option B

6
fantech
Option D
* Diagrams are examples only. Actual installation may vary.
Unit can be installed in a closet. Air drawn from a hallway or living area is cleaned by the HEPA unit and reintroduced back into a bedroom or other
room.
Installation (Cont'd)

7
fantech
Installation (Cont'd)
CM 3000 I - Insulated model
* Diagrams are examples only. Actual installation may vary.
In options A & B, the air handler should operate continuously or when HEPA unit is on and operating.
Special care and attention must be given to ensure that all openings in unit, and its duct connections, are sealed, to prevent vehicle
exhaust from entering the unit. Always follow local and state building codes as well as good engineering practices.
Option A – Garage installation
Option B – Attic installation connected to return of or handler

8
fantech
Installation (Cont'd)
CM 3000 I - Insulated model (continued)
* Diagrams are examples only. Actual installation may vary.
When unit is installed in an unconditioned space such as option C or option D, ductwork (not included) must be insulated and installed according to
local and state codes.
Unit should always be installed in a location that will allow the best possible access for service. Flexible ducting can be restrictive to airflow and
should be kept to a minimum. Avoid excessive turns, cramped ductwork and pinching.
*Proper airflow should be confirmed after installation
Option C – Independently ducted
Option D – Independently ducted installation in crawled space
30" max
recommended
16.5" of clearance is
needed from front of unit to
access lter for service.
Unconditioned
crawl space

9
fantech
Installation (Cont'd)
Whole House – Connecting a ventilation system (HRV/ERV) to a HEPA system
* Diagrams are examples only. Actual installation may vary.
Installation may vary drastically from picture depending on location of all appliances. After installation, proper operation of all the appliances must be
confirmed by a qualified contractor.
Fresh air
from outside
3" to 3" (1m)
Recommended
Minimum of 3' - 3"
(1m) separation of
ducts is recommended
Ventilation system (HRV/ERV) should be installed and balanced in accordance with its installation manual.
Furnace fan must be on when either the ventilation system (HRV/ERV) or the HEPA filtration system is operating.
A power damper is recommended to prevent backdrafting of some models of air to air changers, when in the off or standby position. This damper will
be installed between the HRV/ERV and the HEPA unit.
Models Flex100H, VHR100R, 70R, 150R, 1405R, 2005R, SHR1505R, 2005R & 3005R have an automatic backdraft damper build in that
activates when units are in standby position and do not need this additional damper.
All units should be checked after installation for compatibility and proper operation.

10
fantech
Warranty
• The maintenance free motors are
permanently lubricated and are
guaranteed for 7 years. They are
factory balanced to prevent
vibrations and promote silent
operation.
• All other components have a 5 year
limited warranty. (filters not included)
• The limited warranty covers normal
use. It does not apply to any defects,
malfunctions or failures as a result
of improper installation, abuse,
mishandling or misapplication,
fortuitous occurrence or any other
circumstances outside
manufacturer's control.
• The warranty is in effect for 5 years
on parts and 7 years on the motor
after the date of purchase, including
parts replaced during this time
period. If there is no proof of
purchase available, the date
associated with the serial number
will be used for the beginning of the
warranty period. Parts are a 1 year
warranty when replaced after the
initial warranty has expired.
• This warranty is the exclusive and only
warranty in effect and all other
warranties either expressed or
implied are invalid.
• Warranty from the manufacturer is
for parts only and does not include
labor or shipping to service or repair
them.
Service
The useful service life of the lter media in the HEPA Filtration System is directly related to the
volume of air passed through the system and the amount of contaminants in the air. In a typical
residential application, Stage 1 and 2, lters should be replaced every three to six months or when
needed. The Stage 3 HEPA lter should have a life span of two to ve years, again, depending on
the amount of particulate in the air and the maintenance of the Stage 1 pre-lter.
Filter replacement
Stage 1 - Prelter: Air passes through the prelter where larger particles are taken out of the
air. (part number 40195, also available in packs of 24 part numer 40196)
Stage 2 - Carbon: Air passes through the carbon lter where some gases and odors are
removed. (part number 40195, also available in packs of 24 part numer 40196)
Stage 3 - HEPA: Air passes through the certied HEPA media where very small particles are
removed. 99.97% of all particles 0.3 microns and larger that pass through this stage
are removed. Particles smaller than 0.3 microns are also removed with less intensity.
(part number 40193, also available in packs of 12 part numer 40194)
If the air ow through your unit is noticeably reduced, you can inspect the HEPA lter by removing it
and seeing if the lter paper is darkened on the inlet or outer side. If it is, the lter cartridge should
be replaced.
Please contact your local Fantech dealer or call Fantech Customer Service regarding replacement of
lter media, warranty information or if you have any questions or concerns about the performance
of your HEPA Filtration System.
Replacement parts number for motor (40323) .
Stage 1
Stage 3
Stage 2
Motor

11
fantech
Maintenance
Date Type of Service performed Service Technician
Schedule

12
fantech
Notes

Fantech reserves the right to modify, at any time and without notice, any or all of its products’ features, designs,
components and specifications to maintain their technological leadership position.
Please visit our website www.fantech.net for more detailed technical information.
Série HEPA
Système de filtration de l'air
Manuel d'installation
No. d'article #: 401483
Date de rév.: 2019-12-01
PIÈCES DANS LA BOÎTE (CM 3000)
Système de filtration de l'air, 1 pc
Conduits exibles non isolés de 8 po, 2 pcs
Collets pour orice circulaire de 8 po, 4 pcs
Chaînes de xation et la quincaillerie, 1 pc
Manuel d'installation, 1 pc
PIÈCES DANS LA BOÎTE (CM 3000i)
Système de filtration de l'air, 1 pc
Collets pour orice circulaire de 8 po, 4 pcs
Chaînes de xation et la quincaillerie, 1 pc
Manuel d'installation, 1 pc
CM3000 • CM3000i
États Unis 800.747.1762
Canada 800.565.3548
registration.fantech.app
ENREGISTREZ CE PRODUIT POUR
ÊTRE RAPPELÉ DU PROGRAMME
D'ENTRETIEN SUGGÉRÉ
Votre système de filtration HEPA de Fantech
doit être installé conformément aux exigenc-
es de la municipalité, de la province ou de
l’État où vous habitez ou, à défaut de telles
exigences, conformément à l’édition actuelle
du Code national du bâtiment du Canada ou
aux « méthodes d’ingénierie appropriées » de
l’ASHRAE.

14
fantech
Note Warning/
Important
note
Information Technical
information Practical tip
VEUILLEZ LIRE LE PRÉSENT MANUEL AVANT D’INSTALLER L’APPAREIL
Avant de procéder à l’installation, examinez avec soin la façon dont le système fonctionnera s’il est relié à tout
autre appareil mécanique, notamment une fournaise à air pulsé ou un appareil de traitement d’air dont la pression
statique est plus élevée.
Les produits sont conçus et fabriqués pour fournir une performance able, mais ils ne sont pas garantis à 100%
sans défaut. Même les produis ont des pannes occasionnelles et cette possibilité devrait être reconnue par
l'utilisateur. Si ces produits sont utilisés dans un système de ventilation qui maintien des fonctions vitales où une
défaillance pourrait entraîner des pertes ou des blessures, l'utilisateur doit fournir une ventilation de secours
adéquate, une ventilation supplémentaire naturelle, un système d'alarme de défaillance ou d'accepter les risques
de pertes ou de blessures.
Votre système de ltration HEPA de Fantech doit être installé conformément aux exigences de la municipalité, de
la province ou de l’État où vous habitez ou, à défaut de telles exigences, conformément à l’édition actuelle du Code
national du bâtiment du Canada ou aux « méthodes d’ingénierie appropriées » de l’ASHRAE.

15
fantech
Table des matières
INTRODUCTION..............................................................................4
DIMENSIONS ...............................................................................4
SPÉCIFICATIONS .............................................................................4
OPÉRATION ................................................................................4
INSTALLATION ..............................................................................5
CM 3000 – Modèle non istotherme
Option A.......................................................................5
Option B.......................................................................5
Option C.......................................................................5
Option D.......................................................................6
CM 3000 I – Modèle isotherme
Option A.......................................................................7
Option B.......................................................................7
Option C.......................................................................8
Option D.......................................................................8
Toute la maison – Raccordement d’un système de ventilation (VRC/VRE) à un système de filtration HEPA. ......9
ENTRETIEN................................................................................10
CHANGEMENT DES FILTRES ...................................................................10
CALENDRIER D'ENTRETIEN ....................................................................11
LISTE DES COMPOSANTES ....................................................................24

16
fantech
Introduction
Système de ltration d'air HEPA
Vous êtes l’heureux propriétaire d’un système d’épuration et de traitement de l’air très efcace mis au point selon la technologie de ltration HEPA
(ltre à particules à haute efcacité). Il s’agit du type d’appareil d’épuration de l’air le plus recommandé par les inhalothérapeutes.
An d’optimiser les performances de votre système de ltration HEPA, celui-ci doit être installé par un entrepreneur professionnel bien au fait du
niveau de qualité de l’air ambiant de votre maison et connaissant bien le fonctionnement du matériel de chauffage, de ventilation ou de climatisation que
vous possédez.
Le choix entre deux appareils
Le système de ltration HEPA de Fantech est offert en deux modèles différents selon le type d’installation choisi. Le modèle CM 3000 convient
généralement aux régions où il est possible d’installer l’appareil dans une pièce conditionnée tel un sous-sol, un placard ou un vide sanitaire chauffé
(voir les exemples des pages 5 et 6). Le modèle CM 3000 I (version isotherme) est d’ordinaire utilisé dans les états méridionaux des États-Unis où il
est commun d’installer le matériel CVA (chauffage, ventilation et climatisation) dans un endroit non conditionné, comme un garage ou un grenier (voir
les exemples des pages 7 et 8).
Dimensions
A
B
C
D E
F
Modèle A B C D Ex* F
Diamètre du conduit
Tension Amp Débit
d'air
po mm po mm po mm po mm po mm po mm V Amps pcm
CM 3000 16 1/4413 20 508 10 11/16 420 2 1/456 16 1/2410 8 203 115/V1/60 1 240
CM 3000 I 16 1/4413 20 508 10 11/16 420 2 1/456 16 1/2410 8 203 115/V1/60 1 240
Entrée
d'air
Sortie
d'air
3" Cordon de 3 pi –
Fiche à 3 broches
Avant
Côté
Arrière
Spécifications
* Jeu requis pour l'entretien courant
La CM3000I a une isolation de 1/4 po autour de l'appareil
Modèle CM 3000 (non isotherme)
Une enveloppe isolante peut être achetée séparément et installée sur place au besoin.
Nécessaire (compris): – deux conduits exibles non isolés de 8 po
(homologués UL)
– quatre collets pour orice circulaire de 8 po
– les chaînes de xation et la quincaillerie
– un manuel d’installation.
Modèle CM 3000 I (isotherme)
Nécessaire compris: – deux collets pour orice circulaire de 8 po
(xés)
– les chaînes de xation et la quincaillerie
– un manuel d’installation.

17
fantech
Operation
Votre système de ltration HEPA de Fantech est un système de ltration à trois étages. L’air de la maison est aspiré (voir les différents exemples
d’installation dans le présent manuel) à l’aide d’un ventilateur EBM puissant et efcace. L’air passe dans les ltres pour y être épuré et est ensuite
rediffusé dans la maison exempt de la plupart des particules nocives.
Un calendrier d’entretien semestriel doit être suivi pour assurer un rendement optimal de l’appareil HEPA.
Installation
CM 3000 – Modèle non isotherme
Option A et B
* Les schémas ne sont que des exemples. L’installation réelle peut être différente.
Il est recommandé de raccorder l’appareil HEPA au côté retour d’air de la fournaise. Le côté air fourni est d’ordinaire à éviter en raison de la
pression statique qui y est plus élevée.
Le ventilateur de la fournaise doit fonctionner continuellement ou lorsque l’appareil HEPA est sous tension et en marche. (Options A et B)
Option C
* Les schémas ne sont que des exemples. L’installation réelle peut être différente.
Le réseau de conduits peut être dissimulé dans les murs ou les placards. Si le plancher est le seul endroit possible, il faut alors prendre des
précautions particulières pour éviter le bruit et les refoulements d’air.
Retour d'air
Retour d'air
Option A Option B
Salon Chambre à coucher
Apareil HEPA

18
fantech
Option D
* Les schémas ne sont que des exemples. L’installation réelle peut être différente.
L’appareil peut être installé dans un placard. L’air aspiré d’un couloir ou d’une pièce d’habitation est épuré par l’appareil HEPA et rediffusé dans une
chambre à coucher ou une autre pièce.
Installation (Suite)
Chambre à coucher
Apareil
HEPA
Chambre à coucher
Placard
Apareil
HEPA
Chambre
à coucher
Placard
Chambre
à coucher

19
fantech
Installation (Suite)
CM 3000 I – Modèle isotherme
* Les schémas ne sont que des exemples. L’installation réelle peut être différente.
Pour les options A et B, l’appareil de traitement d’air doit fonctionner continuellement ou lorsque l’appareil HEPA est sous tension et en marche.
Il faut veiller scrupuleusement à ce que toutes les ouvertures de l’appareil et ses raccords de conduit soit scellés pour empêcher que les
gaz d’échappement des véhicules ne pénètrent dans l’appareil.Toujours se conformer aux codes du bâtiment locaux et de la province ou de
l’État ainsi qu’aux méthodes d’ingénierie appropriées.
Option A – Installation dans un garage
Option B – Installation dans un grenier – raccordement au retour d'air d'un appareil de traitement d'air
Door
Door
Garage
Garage
Apareil HEPA
Apareil
HEPA
Retour
Alimentation

20
fantech
Installation (Suite)
CM 3000 I – Modèle isotherme (suite)
* Les schémas ne sont que des exemples. L’installation réelle peut être différente.
Lorsque l’appareil est installé dans un endroit non conditionné, comme dans le cas des options C et D, le réseau de conduits (non compris) doit être
isolé et installé conformément aux codes du bâtiment locaux et provinciaux ou de l’État.
L’appareil doit toujours être installé dans un endroit offrant le meilleur accès possible aux fins d’entretien. Les conduits flexibles peuvent retreindre le
débit d’air et doivent être utilisés par courts segments. Éviter les angles excessifs, de même que l’utilisation de conduits étroits et pincés.
* La constatation d’un débit d’air approprié doit être confirmée après l’installation.
Option C –Installation avec réseau de conduits indépendant
Option D – Installation avec réseau de conduits indépendant dans un vide sanitaire
Hauteur maximale
recommandée de 30 pi
Un jeu de 16,5 po est
nécessaire à l’avant de
l’appareil pour accéder aux
ltres aux ns d’entretien.
Vide sanitaire
non conditionné
Appareil HEPA
Salon Chambre à coucher
Appareil HEPA
Salon Chambre à coucher
This manual suits for next models
4
Table of contents
Languages:
Other System air Water Filtration System manuals
Popular Water Filtration System manuals by other brands

AQUA JOY
AQUA JOY AUTO DELUXE Owner's handbook

Bluewater
Bluewater Spirit Series user manual

Aqua Guard
Aqua Guard AquaSure Aquaflo DX user manual

Ecoplus
Ecoplus ecoPLUS EP-600-UV Owner's manual & installation guide

DELTA PLUS
DELTA PLUS M9000 Series Instructions for use

AQUA FILTER
AQUA FILTER EXCITO installation manual

Astral Pool
Astral Pool Asralpool Chlore Smart 30 Installation and maintenance manual

Puretec
Puretec Sparq S4 user guide

Puretec
Puretec HybridPlus Series user guide

ThePondguy
ThePondguy AllClear Series installation manual

PowerFlex
PowerFlex 700L installation instructions

Pure-Pro
Pure-Pro BB20-02 user manual