Tainet DT-2000 Series User manual

V1.4 07008-00033 6/11/2002
TAINET
DT-2000 Series HDSL
High-bit-rate Digital Subscriber Lines
Termination Unit
USER'S MANUAL
The Professional Partner
TAINET COMMUNICATION SYSTEM CORP.
Headquarters:
No. 25, Alley 15, Lane 120, Sec. 1. Nei-Hu Rd.,
Taipei 114, Taiwan, R.O.C.
TEL: 886-2-26583000
FAX: 886-2-26583232
Beijing Branch:
5F-A, NO.1 Building , 3rd Street , ShangDi information
industry Base , HaiDian District , Beijing , China
Mail BOX:P.O.BOX 100085 EXT.52, Beijing, China
TEL: 86-10-62964775~4779
FAX: 86-10-62964780

INFORMATION TO THE USER
NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device. Pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and if not installed and used in accordance with the instructions
may cause harmful interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on. The user is encouraged to try to correct the interference
by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
This booklet is available from the US government Printing Office, Washington, DC 20402,
Stock NO. 004-000-00345-4.
The shielded RS-232 cable is to be used in order to ensure compliance with FCC Part 15,
and it is the responsibility of the user to provide and use shielded RS-232 cable from
MODEM to personal computer.
CAUTION:Any changes of modifications not expressly approved by the grantee of this
device could void the user's authority to operate the equipment.

FCC REQUIREMENTS
This equipment complies with Part 68 of the FCC Rules. On the base unit of this equipment
is a label that contains, among other information, the FCC Registration Number and Ringer
Equivalence Number (REN) for this equipment. IF REQUESTED, THIS INFORMATION
MUST BE GIVEN TO THE TELEPHONE COMPANY.
The REN is useful to determine the quantity of devices you may connect to your telephone
line and still have all of those devices ring when your telephone number is called. In most,
but not all areas, the sum of the REN's of all devices connected to one line should not
exceed five (5.0). To be certain of the number of devices you may connect to your line, as
determined by the REN you should contact your local telephone company to determine the
maximum REN to your calling area.
If your equipment causes harm to the telephone network, the telephone company may
discontinue your service temporarily. If possible, they will notify you in advance. But the
advance notice isn't practical, you will be notified as soon as possible. You will be informed
of your right to file a complaint with the FCC. Your telephone company may make changes
in its facilities, equipment, operations or procedures that could affect the proper functioning
of your equipment. If they do, you will be notified in advance to give you an opportunity to
maintain uninterrupted telephone service.
If you experience trouble with this telephone equipment, please contact the following
address and phone number for information on obtaining service or repairs.
The telephone company may ask that you disconnect this equipment from the network until
the problem has been corrected or until you are sure that the equipment is not malfunctioning.
This equipment may not be used on coin service provided by the telephone company.
Connection to party lines is subject to state tariffs.
COMPANY: SUMMIT MICRO DESIGN, INC.
ADDRESS:485 MACARA AVE., SUITE 901 SUNNYVALE, CA 94086 USA
TEL NO: (408)739-6348

TABLE OF CONTENTS
CHAPTER 1: INTRODUCTION..................................................1-1
1.1 GENERAL DESCRIPTION...........................................................1-1
1.2 SPECIFICATIONS......................................................................1-3
1.3 MODULE LIST .........................................................................1-6
CHAPTER 2 : UNIT DESCRIPTIONS ........................................2-1
2.1 GENERAL DESCRIPTION...........................................................2-1
2.2RACK MOUNTED UNITS...........................................................2-5
CHAPTER 3 : INSTALLATIONS.................................................3-1
3.1 GENERAL DESCRIPTION...........................................................3-1
3.1.1 Unpacking .......................................................................3-1
3.1.2System Architecture...........................................................3-1
3.2 COMMON INSTALLATION.........................................................3-2
3.2.1The Front Panel Operation ..............................................3-2
3.2.2 The Rear Panel Connection..............................................3-2
3.2.3 Clock Source Configuration..............................................3-3
3.3 DT-2000F/NF FULL-E1 QUICK INSTALLATION.........................3-5
3.3.1 Setting as Co-directional clock (E1-C only).......................3-5
3.3.2 Using different clock source..............................................3-6
3.4 DT-2000F/NF FRACTIONAL E1 QUICK INSTALLATION..............3-7
3.4.1 CO site Installation Steps..................................................3-7
3.4.2 RT site Installation Steps..................................................3-8
3.5 THE INSTALLATION OF DT-2000NFRACK MOUNTED SERIES....3-9
3.5.1 Unpacking .......................................................................3-9
3.5.2 Card Installation..............................................................3-9

3.5.3 E1 and HDSL Loops Connection....................................3-10
CHAPTER 4 : OPERATING MAINTENANCE ..........................4-1
4.1 USING THE LCD MENU ...........................................................4-1
4.1.1 The LCD Menu Display Format.......................................4-1
4.1.2 The Full-E1 LCD Menu Tree (E1-C)................................4-5
4.1.3 The Fractional-E1 LCD Menu Tree (E1-CF) ...................4-7
4.1.4 The DT-2000NF LCD Menu Tree....................................4-9
4.2 OPERATION, CONFIGURATION, ADMINISTRATION AND
MAINTENANCE .....................................................................4-11
4.2.1 STATUS.........................................................................4-11
4.2.2 SYSTEM CONFIG .........................................................4-13
4.2.3 SYSTEM ADMINISTRATON..........................................4-14
4.2.4 ALARM..........................................................................4-15
4.2.5 HDSL CONFIG .............................................................4-17
4.2.6 PERFORMANCE MONITOR ........................................4-19
4.2.7 SYSTEM MAINTAIN ......................................................4-22
4.2.8LOGOUT.......................................................................4-25
APPENDIX.....................................................................................A-1
A. ORDERING INFORMATION.......................................................A-1
B. INTERFACE SPECIFICATIONS...................................................A-2

CHAPTER 1
INTRODUCTION
CONTENT
1.1 General Description
1.2 Specifications
1.3 Module List


INTRODUCTION 1-1
CHAPTER 1: INTRODUCTION
1.1 General Description
lThe TAINET DT-2000 series are High-bit-rate Digital Subscriber Line (HDSL)
systems which deliver 2.048Mbps E1 service to the customer up to 4.5 Km (2.8 miles)
length over four 24 AWG (0.5 mm) lines.
lDT-2000 series, use 2B1Q modulation and support Wetting Current, Power Feeding
fully complies with the ETSI standard ETR 152 provide full and fractional E1, switched
E1 or Nx64K E1 service over two pairs of wires.
lSwitched E1 or N×64K E1 service which is used in Point-to-Point, add-drop
applications such as dial-up video conference, distant learning, and home entertainment,
it also delivers new service such as Switched Multi-Megabit Data Services (SMDS) and
frame relay with speed and economy.
lThe 2B1Q line code is a four-level pulse-amplitude modulation code as shown as Table
1-1. Its power average on a sequence of symbols consist with a frame word in all other
positions is between 13.0 dBm and 14.0 dBm, which over the frequency band from 0
Hz to 1168KHz into a 135 ohms termination.
Binary Digits Quaternary Symbol
First Bit (Sign) Second Bit (Magnitude)
1 0 +3
1 1 +1
0 1 -1
0 0 -3
Table 1-1 The 2B1Q Line Coding
lThe HDSL system consist of Line Termination Unit(LTU) for Central Office (CO) in the
network side, and Network Termination Unit (NTU) for Remote Terminal (RT) in the
user side. It will provide an alternation to repeat E1 lines for buyer to support
repeaterless 2048Kbps rate access over non-loading copper loop.
lSupport either 120 ohms balanced (terminal block) or 75 ohms unbalanced (BNC).
Fractional E1 use one or two loops for data transmission from 64Kbps to 2048Kbps
(N x 64K) of V.35, RS-530, V.36(RS-449) or X.21/V.11 interfaces.
lRack mounted model may apply 16 cards to one shelf. TAINET Network Management
System work over TCP/IP for Windows 9x/NT platform is available.
lRemote configuration will be matched with central site: for general application, users just
need to setup CO and RT to be connected. Once it is connected, the parameters of RT
will follow CO automatically. For example, when CO site setup from Full E1 to
Fractional E1, the RT site will follow up to Fractional E1 too.

1-2INTRODUCTION
lThe features of TAINET DT-2000 Series:
DT-2000 Series Desktop Rack Mounted
Full E1 Only DT-2000 DT-2000N
Full/Fractional
E1 DT-2000F, DT-2000FD DT-2000NF1
Full/Fractional
E1 with Loop
Power
DT-2000FP (sink) DT-2000NF2 (source)
ØFully compliant with ETSI ETR 152
ØCompact desktop and rack mounted
ØFront panel menu driven to serve as LTU/CO (Line Termination Unit/ Central
Office) or NTU/RT (Network Termination Unit/ Remote side)
ØCommunication range up to 4.5Km on 24AWG without line conditions
ØOperate over loops (line interfaces) at data rate 1168Kbps per loop.
ØUtilizes 2B1Q line-code with echo cancellation
ØFull E1 functionality supports G.703 interface of data speed 2.048Mbps.
ØFractional E1 supports G.703 interface of data speed N x 64Kbps.
ØUp to 2 bridged taps of each 500 meters maximum length.
ØExtensive self test , internal BER test and loop test
ØSupporting Point-to-Point, Fractional Operation, D2048U, D2048S and E1 add-
drop applications
ØSetup, control, monitoring via front panel LCD or NMC controller.
ØSupport Network Management System WNMS over TCP/IP.

INTRODUCTION 1-3
1.2 Specifications
lHDSL interface
ØLine Code : 2B1Q (Two Binary One Quaternary)
ØMode : full duplex with echo cancellation
ØNumber of loops : two loops
ØLoop rate : 1168Kbps on each loop
ØBaud rate : 584 K ±32ppm baud
ØFrame format : compliant with ETSI ETR 152 (section 5.4)
ØStart up procedure : compliant with ETSI ETR 152 (section 5.6)
ØEOC and O&M function : compliant with ETSI ETR 152 (section 5.5/5.7)
ØTransmit characteristics (pulse peak ,shape ,power): compliant with ETSI ETR 152
(section 5.8.4)
ØLine impedance : 135 ohms
ØBridge taps : single tap < 500 m , maximum two taps
ØLoop length : 3.6 Km on 26 AWG (0.4 mm) and 4.5 Km on 24 AWG (0.5 mm)
without line conditions
ØReturn loss : compliant with ETSI ETR 152 (section 5.8.2 )
ØPerformance test (DLL model, BER, bit length ...): compliant with ETSI ETR 152
(section 5.9/6.3)
ØJitters tolerance : compliant with ETSI ETR 152 (section 5.9.3/7)
ØDelay difference between pairs : < 60 µsec
ØShaped noise : compliant with ETSI ETR 152 (section 6.3.3)
ØImpulse noise : compliant with ETSI ETR 152 (section 6.3.4)
ØCommon mode rejection : compliant with ETSI ETR 152 (section 6.3.5)
ØMicro interruption : compliant with ETSI ETR 152 (section 6.3.6)
ØConnector : RJ-45 phone jack.
ØSoftware configurable for CO (LTU) side or RT (NTU) side
lE1 interface
ØLine rate : 2.048Mbps ±50ppm
ØLine code : HDB3
ØFrame format : framed or unframed
ØLine impedance : 120 ohms (balanced) or 75 ohms (unbalanced)
ØCompliance : ITU-T G.703 ,G.704 ,G.706 ,G.732 ,G.826
ØJitters performance : compliant with ITU-T G.823
ØConnector : BNC (unbalanced) or RJ-45 phone jack (balanced)

1-4INTRODUCTION
lE1 Clock
ØSource : E1 Internal, E1-C Network, Codirectional (E1-C only).
ØInternal Clock Accuracy : ±32ppm
lIndicators
ØDT-2000FDesktop Series:
PWR, E1, L1, L2, HDSL, TST, BATL, ALM
ØDT-2000NFRack Mounted Series:
SEL, STAT, C/R, E1 LOS/BER, HDSL CONT/SNR, L1 LOSW/BER, L2
LOSW/BER, ALM, RMT/ALM, TST, SCAN.
lMaintenance
ØPerformance monitor :
ØHDSL : ES, SES, FEBE, BER, SNR, etc. (Refer to Chapter 3)
ØE1 : BER, ES, SES, etc. (Refer to Chapter 3)
ØDiagnostics : E1 Network Near End Loopback, Far End Loopback, Customer
near end Loopback. Customer Far End Loopback, Data port loopback, HDSL
Digital Loop Self-test
ØConfiguration backup and recovery to/from external device
ØFront panel switches: Display far-end, Loop back test
ØDT-2000FDesktop Series: front panel switches: Display far-end, Loop back test
ØDT-2000NFRack Mounted Series: front panel LCD and Key switches and NMC-
32 controller
ØLCD : 16 x 2 display
ØKey Switch : Up, Down, Left, Right, Home
ØWNMS with SNMP platform compatible.
lPower
ØDT-2000FDesktop Series:
Local power :
For DT-2000/ DT-2000F : AC Input 85 ~ 260 V, 47 ~ 63 Hz
For DT-2000FD: DC Input –30 ~ -72 V
For DT-2000FP: Loop Power sink(from HDSL loop 110V DC)
Power consumption : Full/Fractional E1< 7.5 watts
Wetting current : > 15mA

INTRODUCTION 1-5
ØDT-2000NFRack Mounted Series:
Max power consumption : 100 watts for full TRS-32 shelf
(-24 VDC input on each DT-2000N)
Wetting current : > 15mA
Loop Power: 110VDC, <140mA (DC -48V input on each card)
lEnvironment
ØTemperature:
Operating : 0°C ~ 50°C
Storage : -25°C ~ 70°C
ØHumidity :
Operating : 10% ~ 90%, non-condensing
Storage : 5% ~ 90%, non-condensing
lPhysical
ØDT-2000FDesktop Series:
Height : 60 mm
Width : 194 mm
Depth : 316 mm
Weight: 1.9 Kg
ØDT-2000NFRack Mounted Series:
Height : 8.2 inch (6U)
Width : 19 inch
Depth : 12 inch
Weight: 0.6 Kg
Full Shelf Equipped: 16 Kg

1-6INTRODUCTION
1.3 Module List
The TAINET DT-2000 series consist of :
HDSL Desktop Series
Model/Module Description
DT-2000 Full E1 HDSL, balanced/unbalanced (120/75 Ohm) G.703 interface support.
DT-2000F Full/Fractional E1 HDSL, with a slot for different user interface module.(AC power)
DT-2000FP Full/Fractional E1 HDSL, with a slot for different user interface module.(Loop power)
DT-2000FD Full/Fractional E1 HDSL, with a slot for different user interface module.(DC power)
Table 1-2 HDSL Standalone module list
USER INTERFACE MODULE
Model/Module Description
/G703U-3Full & Fractional E1, G.703 Unbalanced (75Ω) module, BNC
/G703B-3Full & Fractional E1, G.703 balanced (120Ω) module, terminal block
/G703B-CContra-direction; Fractional E1, G.703 Balance, 64K
/R530-3A Full/Fractional E1, Nx64Kbps (N=1 to 31), RS-530 Female
/V35-3A Full/Fractional E1, Nx64Kbps (N=1 to 31), V.35 Female
/V36-3A Full/Fractional E1, Nx64Kbps (N=1 to 31), V.36 Female with adapter cable
/X21-3A Full/Fractional E1, Nx64Kbps (N=1 to 31), X.21 Female with adapter cable
/Router Router Module
Table 1-3 HDSL User Interface module list
RACK POWER MODULE
Model/Module Description
/PWR-132A AC Power Module (support Wetting Current) for shelf module
/PWR-132D DC Power Module (support Wetting Current) for shelf module
Table 1-4 Rack Power module list
HDSL Rack Mounted LINE CARD
Model/Module Description
DT-2000N Full E1 HDSL, balanced/unbalanced (120/75 Ohm) G.703 interface support.
DT-2000NF1 Full/Fractional E1 HDSL provide wetting current (sealing current).
DT-2000NF2 Full/Fractional E1 HDSL provide loop power .
/V35-1A V.35 module for DT-2000NF
/R530-1RS-530 module for DT-2000NF
Table 1-5 HDSL Rack Mounted Line Card module list
HDSL RACK
Model/Module Description
TRS-32 Rack Mounted Shelf
/TB-32 TRS-32 rear panel module board (option) Terminal block for line connection
/TB-32LP TRS-32 rear panel module board (option) Terminal block for line connection and loop
power input (DC –48V)
/PJ-32A TRS 32 rear panel module board (option) RJ45 for line connection
NMC-32 Rack Mounted Controller
Table 1-6 HDSL Rack module list
HDSL REGENERATOR
Model/Module Description
REG-HHDSL Loop Regenerator
Table 1-7 HDSL Regenerator module list

CHAPTER2
Unit Description
CONTENT
2.1 General Description
2.1.1 Desktop Units
2.1.2 Rack Mounted Units


UNIT DESCRIPTIONS 2-1
CHAPTER 2 : UNIT DESCRIPTIONS
2.1 General Description
DT-2000F HDSL Desktop Unit without DTE interfaces module
Full /Fractional-E1 menu selectable
Optional DTE module V.35 Female
V.36 Female with adapter cable
V.21 Female with adapter cable
G.703 2M balanced/unbalanced
Fig.2-1The front panel view of DT-2000F
Fig.2-2The rear view of DT-2000F
Fig.2-3The rear view of DT-2000FD

2-2UNIT DESCRIPTIONS
The DT-2000F fractional E1 service model, the real panel has a slot for changeable DTE
interface module. Both of DT-2000 and DT-2000F contain an IEC 320 AC Power Inlet
Connector. They use AC power source input, but the DT-2000FD use DC -48V power
source input.
lThe LED Indicators OF DT-2000F:
NAME LED STATUS DESCRIPTION
PWR Green Means POWER ON
E1 Green Indicates E1 LOS/BER condition
Off Means no LOS/BER condition
HDSL
LED Green Indicates SNR of any HDSL loop is below a
predefined threshold
Off SNR of all loops are good
LOOP 1/2 Green Indicates HDSL loop in good condition
LEDs
Off Indicates HDSL loop LOSW (Lost of Sync
Word) condition
Or indicates HDSL loop BER condition
TST
LED Green The test state is active
Off Normal operation
Yellow Means that Battery LowBATL
LED Off Indicates Battery Good
ALM Yellow Indicates an alarm occurred at the far-end or
near end.
LED Off no alarm

UNIT DESCRIPTIONS 2-3
lThe LCD Panel and Key Switches
vprovides LCD control menu for system management and configuration
vwith back light control for power saving
lAC Power Supply Module
vPower Switch for AC Power Input On/Off
lHDSL Interface Module
vOne RJ-45 Phone Jack for connecting to 2 HDSL Loops
lFull E1 Interface Module (Refer to the following demo diagrams)
vOne RJ-45 Phone Jack for Balanced Application
vOne G.703 Unbalanced BNC Connector
vV.35 Interface
vRS530
lFractional E1 Interface Module (Refer to the following demo diagrams)
vV.35 Interface (N x 64 Kbps, N= 1 ~ 31)
vRS-530 interface (N x 64 Kbps, N= 1 ~ 31)
vV.35/RS-449 interface (N x 64 Kbps, N = 1 ~ 31)
vX.21/V.11 interface (N x 64 Kbps, N = 1 ~ 31)
vG.703 Balanced Terminal Block (2.048Mbps)
vG.703 Unbalanced BNC Connector (2.048Mbps)
Fig.2-7 V35-3A, 2.048Mbps, V.35 Data Interface Module; Female

2-4UNIT DESCRIPTIONS
Fig.2-8 R530-3A, 2.048MBps, RS 530 Data Interface module; Female
SW1 Setup
1OFF
2ON
3OFF
4OFF
JP1 CLKI
MMCK
(manufacture test only,
don’t change the setting)
E1 TX
E1 RX
SW1
JP1
Fig.2-9 G703B-3, 2.048MBps, G.703 Balance 120ohm-interface module
E1 TX
E1 RX
SW1
JP1
SW1 Setup
1OFF
2ON
3OFF
4OFF
JP1 CLKI
MMCK
(manufacture test only,
don’t change the setting)
Fig.2-10 G703U-3, 2.048MBps, G.703 Unbalance 75 ohm interface module

UNIT DESCRIPTIONS 2-5
2.2 Rack Mounted Units
TRS-32 Rack Shelf, for sixteen HDSL Line Cards to plug in
NMC-32 Rack Controller, for HDSL Line Cards configuration
PWR-132ARack AC power supply module, using AC power source 85~260V
PWR-132DRack DC power supply module, using DC power source -30~ -72V
DT-2000N HDSL Line Card for Full-E1 only
Full-E1, using G.703 balanced and unbalanced adapter only
Two HDSL loops, using Terminal Block on TRS-32 shelf
DT-2000NF1 HDSL Desktop Unit for Full or Fractional E1
E1 interface, using G.703 balanced and unbalanced adapter
Two HDSL loops, using Terminal Block on TRS-32 shelf
Internal power apply from power module for Wetting Current
Optional DTE module V.35 module (with female adapter cable)
RS530 module (female)
DT-2000NF2 HDSL Desktop Unit for Full-E1 only
E1 interface, using G.703 balanced and unbalanced adapter
Two HDSL loops, using Terminal Block on TRS-32 shelf
DC Power -48V input from outside for loop power supply
Optional DTE module V.35 module (with female adapter cable)
RS530 module (female)
JP5,6,7,8
JP1,2,3,4
JP11,12,15
JP
Enable Sealing Current
Disable Sealing Current
11,12,15
S S O
O O O
JP
Sealing Current on CO
Sealing Current on RT
1, 2, 3, 4
S O O S
O S O O
O: Open
S: Short
3 Volt
Battery
(CR2032)
Fig.2-11 DT-2000N/NF PCB
Caution
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by TAINET.
Dispose of used batteries according to the national instruction of government.
Table of contents
Other Tainet Gateway manuals
Popular Gateway manuals by other brands

AXIOMTEK
AXIOMTEK UST200-83H-FL user manual

Watts
Watts Connected Roof 8200875 quick start guide

SST Automation
SST Automation GT200-HT-DP user manual

NETGEAR
NETGEAR CVG834G Reference manual

HomeMatic
HomeMatic HMW-LGW-O-DR-GS-EU Installation and operating manual

Fujitsu
Fujitsu AIRSTAGE UTY-ABGXZ1 instruction manual

Moxa Technologies
Moxa Technologies AIG-501-T-AZU-LX Quick installation guide

Endress+Hauser
Endress+Hauser Firldgate SFG500 manual

RTA
RTA 460MSMM-NNA1 Product user guide

ZyXEL Communications
ZyXEL Communications 802.11g ADSL 2+ 4-Port Security Gateway HW-D... user guide

AudioCodes
AudioCodes MP-204 quick start guide

RTA
RTA 460ECMS-N2EW user guide