WALL TERMINATION VENTING
Exterior wall opening:
Determine the exact position of the replace so that the vent
pipe is centred (if possible) between two building framing
members. Consult your local building codes prior to proceed-
ing. The vent kit will accommodate up to a maximum wall
thickness of 12 inches.
1) Having determined the position of the replace, cut and
frame a 14-1/2 inches opening centred at a minimum
height of 74-1/4 inches above the oor. The opening may
be round or square. Height of the opening will vary with
each installation. As the horizontal vent run increases, so
does the minimum vertical rise (see Fig. #17).
IMPORTANT: When locating the opening, it should be
noted that vent terminal clearances must be maintained.
See "Vent Terminal Clearances" section for proper
clearances.
A minimum 2 foot length of pipe is required for any wall ter-
mination. With this minimal vertical rise in combination with a
90° elbow, a maximum horizontal run of 18inches is permitted
(see Fig. #17 and 18). For longer horizontal runs greater than
18inches, increase vertical rise appropriately. The rise and
run must be constrained to the boundaries of the chart shown
in gure #17. The horizontal run of vent should have a 1/4"
rise for every 1 ft. of run towards the termination.
HEARTH EXTENSION
While a hearth extension is not required
for this replace, one is recommended for
aesthetic reasons. The hearth extension
should be noncombustible and must not
be any more than 1" above the bottom of
the replace. If thicker, replace must be
raised up accordingly.
Caution: Hearth extensions thicker than
1" will interfere with the window frame.
1
4"
1"
MAX
WINDOW
FRAME
HEARTH
EXTENSION
WINDOW
TRACK
SUB-
FLOOR
Fig. # 13
VENTING
Before installing venting for this unit, the installer should read
these instructions to insure that the proper vent conguration
has been selected.
Use only Town and Country Termination kits #:
TCVT.WTA - Wall Termination Kit
TCVT.RTA - Roof Termination Kit
Vent system components approved for use with the Town and
Country Fireplace are shown in Figure #15.
Various combinations of vertical and horizontal runs may be
used. Refer to Figure # 17 and 18for details. For optimum
performance and ame appearance, keep the vent length
to a minimum and limit the number of elbows. Connections
between each vent system component must be tightly joined,
secured with sheet metal screws and sealed. A horizontal run
of vent should have a 1/4" rise for every 1 ft. of run towards
the termination.
CAUTION: UNDER NO CONDITION SHOULD COMBUSTI-
BLE MATERIAL BE CLOSER THAN 1 3/4 INCHES FROM
THE SIDES AND BOTTOM AND 1 3/4 INCHES FROM
THE TOP OF A HORIZONTAL SECTIONS OF THE VENT
PIPE AND 1 3/4 INCHES FROM A VERTICAL SECTION
OF PIPE.