TCS VBVS05-SG User manual

TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes.
TCS Hotline Germany • Mail: hotline@tcsag.de PI_VBVS05-uk
Product information
Power supply and control unit
VBVS05-SG
for small and medium-sized systems

2 11/2012
TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes.
Safety instructions
General safety regulations
!
Attention! Mounting, installation, commissioning and repair of electronic devices have
to be carried out only by qualified electricians. The standard for the prevention of acci-
dents must be observed!
When working in systems with 230 V mains voltage, the safety requirements according to
DIN VDE 0100 must be observed.
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
separated cabling of heavy and low current lines,
minimum distance of 10 cm for common cabling,
use of separators between heavy and low current lines in shared cable ducts,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
existing lines (modernisation) with deviating cross sections can be used in compliance
with the loop resistance.
Attention!
Fluids or small electroconductive parts which enter the device can cause a short-circuit,
fire or an electric shock. Please, avoid contacting the device with water or other fluids.
Avoid small electroconductive parts from entering the device (e.g. in the ventilation lou-
vres).
The device produces heat. Ensure a sufficiently ventilation. Do not cover existing venti-
lation louvres.
Installation –protective measures
Outside the device, an easy accessible separating unit for mains separation is neces-
sary.
An overcurrent protective device is to be installed upstream.
The device is to be installed in a way, that the user does not have any direct access to
the area of the mains connection terminal after the installation.
With suitable requirements to protect against lightning, it has to be ensured that a volt-
age of 32 V DC is not exceeded at the connections a, b and P.
The device is conform to the overvoltage category II.
Scope of delivery
1 x VBVS05-SG
1 x Product information

3 11/2012
TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes.
TCS Hotline Germany Mail: hotline@tcsag.de PI_VBVS05-uk - uk
Device overview
Technical data
Input voltage: 230 V ± 10 %, 50 - 60 Hz
Input nominal voltage: 0.35 mA
Housing: DIN-rail housing 4 SU for DIN-rail mounting
DIN EN 50022
Weight 800 g
Acceptable ambient temperature: 0 C to 40 C
Degree of protection: II
Output current a-terminal: I(a) = 60 mA
Output current P-terminal: I(P) = 600 mA
I(Pmax) = 700 mA
(for:1 min load / 10 min break between two
max. loads)
Door release voltage (idle running): U(Tö) = 12 V ± 2 V, 50 Hz (load-dependent)
External mains fuse: 16 A (recommended)
Connection for door opener
Potentiometer to set the
light switch time
Potentiometer to set the
door release time
Run/Prog-button
Run/Prog-
indication (LED)
Connection to switch lights
Connection for TCS:BUS
Connection for video
Connection for mains voltage

4 11/2012
TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes.
Usage
The VBVS05-SG is used for the central supply and control of small and medium-sized vid-
eo or audio systems with one strand.
The loop resistance must not exceed max. 5 Ohm (when in 5-wire operation).
The device can be used exclusively to supply the TCS:BUS. Any other use is considered
improper and is prohibited.
Short description
Basic functions
Controlling and indication of
the operation modes of the
system
via LED
Strand and P-terminal
Short-circuit protected against b-wire
Additional functions
Potential-free relay contact
(closing contact)
to control automatic light switching units 24 V / 2 A
Door release function
with integrated voltage supply, relay contact for door re-
lease with R ≥6 Ohm / 12 V
Door release time
adjustable from 1 to 8 s
Light switch function
Can be activated with the VBVS05. By pressing the door
release button at the indoor station, the lights can be
switched via the connected automatic light switch unit, if
the handset is hung up (no voice connection).
Factory setting: The function is not activated.
Light switch time
adjustable from 1 s to 5 min.
can be connected to:
automatic light switch unit (max. acceptable contact
load-capacity of 24 V DC / 2 A)
staircase light control unit FNA1000 (with 8-24V AC)
relay

5 11/2012
TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes.
TCS Hotline Germany Mail: hotline@tcsag.de PI_VBVS05-uk - uk
Installation
Wiring diagram
Connection diagram
max. 12 video indoor stations
Place matching
resistor, if the de-
vice is installed at
the end of a
TCS:BUS video
strand.
Preferably, the video terminals V1 and V2 of the indoor and front-door station have to be con-
nected directly. The terminals 32, 33 of the VBVS05 can be used as auxiliary terminals.
Floor
push button
Floor
push button

6 11/2012
TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes.
Wiring example: connect staircase light control unit FNA1000-0400
Setting
Door release time
System is operating, LED is ON
Set time afterwards switch ON and OFF again the programming mode of the system:
–: min. 1 s RUN/PROG-button LED blinks RUN/PROG-button LED is ON
+: max. 8 s shortly press shortly press
Light switch time
System is operating, LED is ON
Set time afterwards switch ON and OFF again the programming mode of the system:
–: min. 1 s RUN/PROG-button LED blinks RUN/PROG-button LED is ON
+: max. 5 min shortly press shortly press
Legend to setting, programming, operation
Press button until …
LED blinks slowly
Shortly press button
LED is ON
Release button
further

7 11/2012
TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes.
TCS Hotline Germany Mail: hotline@tcsag.de PI_VBVS05-uk - uk
Programming
Activate light
switch function*
Deactivate light
switch function*
*) That the LED is blinking does not mean, that the device is in programming mode.
Operation
System is operating, LED is ON
Switch ON the programming mode
of the system
Shortly press
RUN/PROG-button
LED blinks
Switch OFF the programming mode
of the system
Shortly press
RUN/PROG-button
LED is ON
FAQ
Error pattern
Possible cause
Our suggested solution
Speaking at the indoor station
is very quiet.
By interchanging or short-circuit
of the a-P-wires, a resistor at the
VBVS05 was damaged.
VBVS05 repair (replace)

8 11/2012
TCS TürControlSysteme AG: www.tcsag.de Subject to technical changes.
Conformity
The declarations of conformity are available under www.tcsag.de, Downloads, trade
information.
Information on diposal
The adjoining symbol shows that the device has to be disposed separately from
domestic waste. The materials used are recyclable. Please do help protecting our
environment and dispose the device via a collecting point for electronic scrap.
Dispose the parts of the packaging in collecting tanks for cardboard and paper
resp. plastics.
Warranty
We offer a simpliefied processing in case of warranty for electricians.
Please note our conditions of sale and delivery, download from www.tcsag.de, Down-
loads, trade information.
Please contact the TCS HOTLINE.
Service
Please send your questions and inquiries to
Head quarters
TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, D-39307 Genthin
Tel.:+49 (0) 3933/879910, FAX:+49 (0) 3933/879911, Mail: info@ tcsag.de, www.tcsag.de
Table of contents
Other TCS Control Unit manuals
Popular Control Unit manuals by other brands

LOGICDATA
LOGICDATA CBX-1 user manual

Carrier
Carrier Infinity SYSTXCCITC01-B owner's manual

Automationdirect.com
Automationdirect.com Productivity 2000 P2-08TD1S manual

Digilent
Digilent PmodBT2 Reference manual

Solid Technologies
Solid Technologies HERCULES user manual

GEM
GEM 653 Installation, operating and maintenance instructions

Ricoh
Ricoh 411402 - EFI Fiery EB-105EX Controller printing guide

Emerson
Emerson Asco PV-MXX-272/374 Series Installation and maintenance instructions

EOS
EOS SBM GLT KNX Installation and operating instructions

Digi
Digi Connect Wi-ME 9210 quick start guide

DSC
DSC PC5928 quick start guide

WDT
WDT Granudos 10 Touch Operating and installation instructions