・All specifications are subject to change without notice.
10
RTW 150W
Outline Drawing
TypeL(terminalblockfacingupward,withoutcover)
* The insertion length of screws used for mounting the power supply should
be within 6mm from the product surface.
Unit: mm
Allowable tolerance is ±1mm if not specied separately.
+S
+
-
-S
+RS
-RC
G
L
N
UP
UP
UP
(5.2)
3-M4×0.7
147.5
±0.5
17
±0.5
175
26
7
29.2
Indicator of output voltage On Output voltage trimmer
4MAX
2
-
M4×6L
7
-
M3×6L
Short plate
Name plate
Board
Frame
2
-
M4×0.7
(86.7)
(86.25)
(39.1) (10.2)(8.62)(7.62)
(12.5)
(7)
191.5
Remote On/Off switch
Name plate
Name
plate
Name plate
Insulation plate
77±0.5
155±0.5
9
92
8
Terminal No.
Name and function
1 AC input terminal (N) Connects to AC.100-120V or AC.200-240V input line.
2 AC input terminal (L) Connects to AC.100-120V or AC.200-240V input line.
3 Ground terminal (G) Connects to the ground line. This is connected to the case.
4 Remote On/O terminal (+RC, -RC)
By inputting external signals between terminals, the output voltage can be switched on and o from outside
the power supply. Output is not generated if voltage is not applied to RC terminal. The RC terminal is oated.
5 Remote sensing terminal (+S, -S) Used for compensating for voltage drop to load. The line between the remote sensing termi-
nal and DC output terminal is short-circuited with a short piece.
6 DC output terminal (+, -) Connects the load line.
7 Output voltage trimmer (V.ADJ)
Output voltage can be varied. Voltage increases by turning the trimmer in a clockwise direction.
8 LED output indicator (green) The LED is lit green when output voltage is generated.
9Switch for use/nonuse of Remote On/O
function
Remote On/O function is activated by setting the switch for use/nonuse of Remote On/O
function, located in the center of the power supply, to Y (turning in a clockwise deirection).
Terminals
Type with cover/without cover Type L
8
+S
G
L
N1
2
3
4
5
6
7
+RC
ー
RC
ー
S
+
ー
7
9
+S
G
L
N
1
2
3
4
5
6
+RC
ー
RC
ー
S
+
ー
8
7 9
・All specifications are subject to change without notice.
RTW300W Specifications
With nominal input/output voltage, maximum output current, and Ta=25°C, if not specified separately.
(*1) In primary surge current, 25°C.
(*2)
The maximum output current value is between -10°C and +40°C. For use in outside this temperature range, Derating is needed.
(*3) 30min to 8h after the start of input voltage application.
(*4) 1.5 times the value in 100MHz and at between -10°C and 0°C.
(*5)
Fixed current reduction system; current is shut down if overload condition continues 15 seconds or over. Restarting input
Resumes after (approximately 30s interval) or resetting remote control. (Shutdown by low output voltage detection in 3/5/28V models)
(*6) The detection value tracks the set output voltage (Vo). Output voltage shutdown system,
Resumes by restarting input (approximately 30s interval) or resetting remote control.
(*7) Output is shut down in the condition of 60% or lower of the nominal voltage for 3.3V and 5V models. For 28V models, Output
is shut down in the when the nominal voltage is 20% or lower. Other models do not have this function.
ITEMS/UNITS
MODEL
RTW03-70RH RTW05-60RH RTW12-25RH RTW15-20RH RTW24-13RH RTW28-11RH RTW48-6R5H
Input
Voltage Range (Nominal: 100-240VAC)
V AC85 - 265
Frequency
(Nominal: 50-60 single phase) Hz 47 - 66
Power Factor (100/240VAC)(typ)
0.99/0.93
Efficiency (100VAC)(typ) %6858384838
Efficiency (200VAC)(typ) %9888687868
Current
(100/200VAC)
(max)
A 4.0/2.0(3.3V:3.6/1.8) max
Inrush Current (100/200VAC)(typ) (*1)
A 15/30
Leakage Current (100/240VAC) (max)
mA 0.5/0.7
Output
Nominal Voltage
VDC
3.3 5 12 15 24 28 48
Maximum Current (*2) A 70 60 25 20
13(peak 20)
11 6.5
Maximum Power W 231 300 312 308 312
Maximum Line Regulation
(Within input voltage range) (max/typ)
0.2%/0.1%
Maximum Load Regulation
(0-100% load) (max/typ) 0.4%/0.2%
Temperature Coefficient
(Ambient temperature -10℃to +71℃) (max/typ)
%1.0/0.5
Warm Up Drift (max/typ) (*3) %0.5/0.2
Max Power Total Regulation (max/typ)
%1.8/ 0.9
Maximum Ripple Voltage (max) (*4)
mVp-p
80 100 150 200
Maximum Ripple & Noise (max) (*4)
mVp-p
120 150 200 300
Start Up Time (100/240VAC)(typ) (*5)
ms 220/120
Hold-up Time (100/240VAC)(typ) ms 30/40 25/30 30/40 25/30 30/40
Voltage Adjustable Range
VDC
1.8 - 3.6 3.5 - 5.6 7.2 - 14.4 10.5 - 18.0 16.8 - 26.4 19.6 - 33.6 33.6 - 55.0
Function
Over Current Protection (*6)
A
73.5 - 84.0 63.0 - 72.0 26.3 - 30.0 21.0 - 24.0 11.5 - 13.2 6.8 - 7.8
Over Voltage Protection (*7)
VDC
Vo+0.66 - 1.32
Vo+1.0 - 2.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6
Vo+5.6
-
10.4
Vo+1.0 - 10
Not availableOver Temperature Protection
AvailableRemote Sensing
AvailableRemote ON/OFF Control (*8)
Parallel Operation
Applicable (current balance function and master/slave operation are supported; synchronized operation is not supported)
Series Operation Available (green LED)
Operation Indicator Available
Variable Output Voltage Available (power fail signal)
Low Output Voltage Dectation (*7) Available
Environment
Operating Temperature
℃
-10 to +71
Storage Temperature
℃
-30 to +75
Operating Humidity
%RH
10-95 (the conditions of maximum 35°C in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
%RH
10-95 (the conditions of maximum 35°C in wet bulb temperature and non-condensation should be ensured.)
Vibration 5-10Hz, 10 minutes sweep, 10mmp-p total amplitude, 3 directions, 1h for each, in non-operation
10-200Hz, 10 minutes sweep, 19.6m/s² (2G) acceleration, 3 directions, 1h for each, in non-operation
Shock 588m/s² (60G), 11 5ms, 3 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
For 1 minute at ordinary temperature and humidity
Between input terminal and ground terminal: 2.0kVAC, 10mA cutout current
Between input terminal and output terminal: 3.0kVAC, 10mA cutout current
Between output terminal and ground terminal: 500VAC, 40mA cutout current
Isolation Resistance
In 500VDC and 100MΩor over at ordinary temperature and humidity
Between input terminal and ground terminal, between input terminal and output terminal, and
between output terminal and ground terminal
Standards
Safety Standards
PFHC Complying with EN61000-3-2
EMI Complying with FCC-Class B / VCCI-Class B / EN55011-B / EN55032-B
Immunity Complying with EN61000-4-2 Level2, 3, -3 Level3, -4 Level3, -5 Level3, 4, -6 Level3, -8 Level4, -11
Mechanical
Weight
without cover / with cover / type L (max)
g
1300/1200
Size (W x H x D)
without cover / with cover / type L
mm
40 x 120 x 250/40 x 120 x 250
Models of different
Detailed product name1 with cover
RTW03-70RL RTW05-60RL RTW12-25RL RTW15-20RL RTW24-13RL RTW28-11RL RTW48-6R5L
RTW 300W
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1.
(Expire date of 60950-1: 20/12/2020) Designed to meet Den-an Appendix 8 at 100VAC only.
11