Technical Concepts Autoflush Clamp User manual

Manufacturedby:
TECHNICAL CONCEPTS •1-800-551-5155
®
AutoFlush®Clamp
forUrinals&Toilets
LooksClean-IsClean™
TheAutoFlush®sendsoutacontinuousinfraredbeamthatisreflectedbackbythepresenceofapersoninfrontoftheurinal
ortoilet.“ObjectLock”technologydifferentiatesbetweensomeonewalkingpasttheunitoractuallyusingthefixture.
Ifflush handleisleaking,replacebeforeinstallingAutoFlush®
AutoFlush®forUrinals
AutoFlush®forToilets
Allen Wrench
Sensor Adjustment
Tool
4 “C”Alkaline Batteries
AUTOFLUSH®COMPONENTS
-+
-
+
1.1 UsingthesuppliedAllen
wrench,removebatterycom-
partment.
1.2 RemoveAutoFlush®coverby
rotatingthecoverupatthe
endoverthebatterycom-
partmentandslideout.
Seeillustration1.2
INSTRUCTIONS
1.1
1.2
(Continued)
1.3 UsetheAllenwrenchto
unscrewthetwohexboltsat
theneckoftheunituntila
fewthreadsarestillscrewed
intotheconnectingbracket.
1.4 SlidetheAutoFlush®onto
theflushhandleandsecure
themountingclampoverthe
existinghandlebase.
NOTE:Iftheunitisonahighmount
toiletflushvalvewheretheflushhan-
dleisapproximately40”abovethe
floor,youshouldrotatetheAutoFlush®
downtoensuresensorisdirected
atuser.
1.3
1.4
(Continued)
1.5 ReplacetheAutoFlush®cover.
Seeillustration1.5
1.6 Install4“C”cellalkalinebat-
teriesintothebatterycom-
partmentnotingthebattery
positionmarksontheinside
ofthecompartment. Slide
thebatterycompartmentinto
theAutoFlush®unitand
securetraywithAllenwrench.
Thelastthreeturnsofthe
wrenchwillactivatethe
AutoFlush®unit.
1.5
--
+
-
++
1.6
1.4
NOTE: FitsSloan andZurn flushhandles. Tofitotherflushhandles contactTC customerserviceat800-551-5155.
Step1.
Step1.Step1.

--
+
-
++
UseAllenwrenchtoremove
batterycompartmenttray.
Removecoverbyrotatingthe
coverupattheendoverthe
batterycompartmentand
slideout.
Removerubberseal.
APPENDIXA-ADJUSTINGYOURAUTOFLUSH®TOCHANGEACTIVATIONDISTANCEFORTHEOBJECTLOCKSENSOR:
1Removebatterycompartment. Seeillustration2.1.
2Removecover. Seeillustration2.2.
3ReplacebatterycompartmentinAutoFlush®toactivateunitandremoverubberseal. Seeillustration2.3.
4PresssensorrangeresetbuttonasindicatedinAppendixA. NOTE:thegreenL.E.D.willflashcontinuously
whenithasanobjectinviewforthesevenminuteresetperiod.
5Standatdesiredactivationdistance.
6UseprovidedsensoradjustmenttoolandturnSensorRangeAdjustmentScrewallthewaydown(count-
erclockwise)andthenturnslowlyup(clockwise)untilgreenL.E.D.beginstoflash.
7EnsureObjectLockSensorisnotdetectingstalldoororwallbyclosingdoor,steppingoutofsensorpath
andmakingsuregreenL.E.D.isnotflashing. Ifsensorlocksontodoororwall,unitwillnotflushproperly.
Shortenactivationdistance.
8Removebatterycompartment,andreplacecover. Replacebatterycompartmenttraytoreactivate
AutoFlush®unit.
9After7minutestart-upsequence,thegreenL.E.D.willflashonly3timeswhenauserisinview
(aftera5seconddelay).
1
ON
2
1
ON
2
-+
SensorRange
AdjustmentScrew Short Long
Operation
Features* Switch1
24HoursFlushOff
Switch2
AlarmToneOff
Switch1
24HoursFlushOff
Switch2
AlarmToneOn
Switch1
24HoursFlushOn
Switch1
24HoursFlushOn
Switch2
AlarmToneOn Switch2
AlarmToneOff
SensorRangeResetButton
CourtesyManual
FlushButton
(ToiletModelOnly)
Allowsmanualactivation
offlushifneeded.
SensorRange
Adjustment
UseSensor
Adjustment
Tool
BatteryLED(Yellow)FlashingLED=ChangeBatteries
*TrapSealProtection(24hrflush):Ensuresfixturesareflushedatleastonceevery24hours.Thisfeaturepreventssewergases
escapingthroughopentrap.Thisfeaturecanbeturnedoffbyplacingswitch#1inthedownposition.
*BatteryReplacementTone: OptionalaudiotonereinforcesyellowLED(changebatteries).Thisfeaturecanbeturnedoffby
placingswitch#2inthedownposition.
ObjectLockSensor-DetectsUserorObject
User-In-ViewLED(Green)Flashes3Times=Useracknowledged&readytooperate.
1
ON
2
1
ON
2
1
ON
21
ON
2
TROUBLESHOOTINGGUIDE
PROBLEM CAUSE SOLUTIONTOPROBLEM
GreenL.E.D.(light)flashes3
timeswhentherearenousers
GreenL.E.D.(light)flashes
continuouslywhenObjectLock
Sensorisactivatedbyauser
YellowL.E.D.(light)flashes
Notenoughwatertofixtureor
toomuchwatertofixture
Valvewillnotoperate
Valvedoesnotshutoff
Valvedoesnotflushevenafter
SensorRangehasbeen
adjusted
FrontofObjectLockSensoriscoveredorObject
LockSensorissettoofarout,registeringthe
oppositewallordoorasauser
AutoFlush®unitisin7minutestartupmode
(whenfirstactivated)orSensorRangeReset
Buttonhasbeendepressed
Batteriesneedreplacing
Diaphragmdamagedorvalvecontrolstop
improperlyadjusted
ObjectLockSensorrangesettocloseto
AutoFlush®,batteriesaredead,orwatersupply
isturnedoff
Dirtordebrispreventingdiaphragmfromfunc-
tioningproperly
Deadbatteries
RemoveitemcoveringsensororadjustObjectLock
Sensoractivationdistance.(SeeAppendixA-
AdjustingtheAutoFlush)
GreenL.E.D.(light)willflashonly3times
acknowledgingauserisinviewafterthe7minute
startupmode
Replacebatteries. UseONLYalkalinebatteries
Replacediaphragmand/oradjustvalvecontrolstop
AdjustObjectLockSensor—Replacebatteries—Turn
wateron.IftheAutoFlush®doesnotbegintofunction,
call(800)551-5155fortechnicalassistance.
Removedirtordebris,consultvalvemanufacturer’s
directions
Replacebatteries.
YourAutoFlush®unitcomespresetfromthefacto-
ry.Ifspecialcircumstancesrequireadjustmentof
theactivationdistance,seeAppendixA—
AdjustingYourAutoFlush®.
TheAutoFlush®unithasa7minutestart-up
sequenceinwhichtheObjectLockSensorwill
activatetheUser-In-Viewgreen L.E.D. continu-
ouslyaslongasauserorobjectisinview. After
thestart-upsequenceiscompletedandwhenthe
ObjectLockSensorhasauserinview,theUser-In-
Viewgreen L.E.D.willflash3timesoncetheuser
isinfrontoftheunitforaminimumof5seconds.
This preventsneedlessflusheswhensomeone
walksby.
ACTIVATION
USER-IN-VIEWL.E.D. (Greenlightflashes3times,after
5seconddelay,whenauserisinview. Thegreenlight
flashesconstantlywhenauserisinviewduring
the7minutestartupsequence).
OBJECTLOCKSENSOR
(Detectsuserorobject).
BATTERYL.E.D. (Yellowlightflashes
indicatingitistimetoreplace
batterieswith4new“C”cellalkalinebatteries).
COURTESYMANUALFLUSHBUTTON
(Allowsmanualactivationof
flushwhenneeded—Toilet
modelonly).
VISUALINDICATORGUIDE
1
ON
2
2.1
2.2
2.3
SpanishandFrench instructionsareavailableatwww.technicalconcepts.com
InstrucciónesenFrancesy en Españolestarandisponiblesen la paginawww.techicalconcepts.com
Lesinstructionssont disponibles enfrancais et enespagnolsurnotre site web;www.technicalconcepts.com
Step2.