Technical Concepts Autoflush Clamp User manual

Manufacturedby:
TECHNICAL CONCEPTS •1-800-551-5155
®
AutoFlush®Clamp
forUrinals&Toilets
LooksClean-IsClean™
TheAutoFlush®sendsoutacontinuousinfraredbeamthatisreflectedbackbythepresenceofapersoninfrontoftheurinal
ortoilet.“ObjectLock”technologydifferentiatesbetweensomeonewalkingpasttheunitoractuallyusingthefixture.
Ifflush handleisleaking,replacebeforeinstallingAutoFlush®
AutoFlush®forUrinals
AutoFlush®forToilets
Allen Wrench
Sensor Adjustment
Tool
4 “C”Alkaline Batteries
AUTOFLUSH®COMPONENTS
-+
-
+
1.1 UsingthesuppliedAllen
wrench,removebatterycom-
partment.
1.2 RemoveAutoFlush®coverby
rotatingthecoverupatthe
endoverthebatterycom-
partmentandslideout.
Seeillustration1.2
INSTRUCTIONS
1.1
1.2
(Continued)
1.3 UsetheAllenwrenchto
unscrewthetwohexboltsat
theneckoftheunituntila
fewthreadsarestillscrewed
intotheconnectingbracket.
1.4 SlidetheAutoFlush®onto
theflushhandleandsecure
themountingclampoverthe
existinghandlebase.
NOTE:Iftheunitisonahighmount
toiletflushvalvewheretheflushhan-
dleisapproximately40”abovethe
floor,youshouldrotatetheAutoFlush®
downtoensuresensorisdirected
atuser.
1.3
1.4
(Continued)
1.5 ReplacetheAutoFlush®cover.
Seeillustration1.5
1.6 Install4“C”cellalkalinebat-
teriesintothebatterycom-
partmentnotingthebattery
positionmarksontheinside
ofthecompartment. Slide
thebatterycompartmentinto
theAutoFlush®unitand
securetraywithAllenwrench.
Thelastthreeturnsofthe
wrenchwillactivatethe
AutoFlush®unit.
1.5
--
+
-
++
1.6
1.4
NOTE: FitsSloan andZurn flushhandles. Tofitotherflushhandles contactTC customerserviceat800-551-5155.
Step1.
Step1.Step1.

--
+
-
++
UseAllenwrenchtoremove
batterycompartmenttray.
Removecoverbyrotatingthe
coverupattheendoverthe
batterycompartmentand
slideout.
Removerubberseal.
APPENDIXA-ADJUSTINGYOURAUTOFLUSH®TOCHANGEACTIVATIONDISTANCEFORTHEOBJECTLOCKSENSOR:
1Removebatterycompartment. Seeillustration2.1.
2Removecover. Seeillustration2.2.
3ReplacebatterycompartmentinAutoFlush®toactivateunitandremoverubberseal. Seeillustration2.3.
4PresssensorrangeresetbuttonasindicatedinAppendixA. NOTE:thegreenL.E.D.willflashcontinuously
whenithasanobjectinviewforthesevenminuteresetperiod.
5Standatdesiredactivationdistance.
6UseprovidedsensoradjustmenttoolandturnSensorRangeAdjustmentScrewallthewaydown(count-
erclockwise)andthenturnslowlyup(clockwise)untilgreenL.E.D.beginstoflash.
7EnsureObjectLockSensorisnotdetectingstalldoororwallbyclosingdoor,steppingoutofsensorpath
andmakingsuregreenL.E.D.isnotflashing. Ifsensorlocksontodoororwall,unitwillnotflushproperly.
Shortenactivationdistance.
8Removebatterycompartment,andreplacecover. Replacebatterycompartmenttraytoreactivate
AutoFlush®unit.
9After7minutestart-upsequence,thegreenL.E.D.willflashonly3timeswhenauserisinview
(aftera5seconddelay).
1
ON
2
1
ON
2
-+
SensorRange
AdjustmentScrew Short Long
Operation
Features* Switch1
24HoursFlushOff
Switch2
AlarmToneOff
Switch1
24HoursFlushOff
Switch2
AlarmToneOn
Switch1
24HoursFlushOn
Switch1
24HoursFlushOn
Switch2
AlarmToneOn Switch2
AlarmToneOff
SensorRangeResetButton
CourtesyManual
FlushButton
(ToiletModelOnly)
Allowsmanualactivation
offlushifneeded.
SensorRange
Adjustment
UseSensor
Adjustment
Tool
BatteryLED(Yellow)FlashingLED=ChangeBatteries
*TrapSealProtection(24hrflush):Ensuresfixturesareflushedatleastonceevery24hours.Thisfeaturepreventssewergases
escapingthroughopentrap.Thisfeaturecanbeturnedoffbyplacingswitch#1inthedownposition.
*BatteryReplacementTone: OptionalaudiotonereinforcesyellowLED(changebatteries).Thisfeaturecanbeturnedoffby
placingswitch#2inthedownposition.
ObjectLockSensor-DetectsUserorObject
User-In-ViewLED(Green)Flashes3Times=Useracknowledged&readytooperate.
1
ON
2
1
ON
2
1
ON
21
ON
2
TROUBLESHOOTINGGUIDE
PROBLEM CAUSE SOLUTIONTOPROBLEM
GreenL.E.D.(light)flashes3
timeswhentherearenousers
GreenL.E.D.(light)flashes
continuouslywhenObjectLock
Sensorisactivatedbyauser
YellowL.E.D.(light)flashes
Notenoughwatertofixtureor
toomuchwatertofixture
Valvewillnotoperate
Valvedoesnotshutoff
Valvedoesnotflushevenafter
SensorRangehasbeen
adjusted
FrontofObjectLockSensoriscoveredorObject
LockSensorissettoofarout,registeringthe
oppositewallordoorasauser
AutoFlush®unitisin7minutestartupmode
(whenfirstactivated)orSensorRangeReset
Buttonhasbeendepressed
Batteriesneedreplacing
Diaphragmdamagedorvalvecontrolstop
improperlyadjusted
ObjectLockSensorrangesettocloseto
AutoFlush®,batteriesaredead,orwatersupply
isturnedoff
Dirtordebrispreventingdiaphragmfromfunc-
tioningproperly
Deadbatteries
RemoveitemcoveringsensororadjustObjectLock
Sensoractivationdistance.(SeeAppendixA-
AdjustingtheAutoFlush)
GreenL.E.D.(light)willflashonly3times
acknowledgingauserisinviewafterthe7minute
startupmode
Replacebatteries. UseONLYalkalinebatteries
Replacediaphragmand/oradjustvalvecontrolstop
AdjustObjectLockSensor—Replacebatteries—Turn
wateron.IftheAutoFlush®doesnotbegintofunction,
call(800)551-5155fortechnicalassistance.
Removedirtordebris,consultvalvemanufacturer’s
directions
Replacebatteries.
YourAutoFlush®unitcomespresetfromthefacto-
ry.Ifspecialcircumstancesrequireadjustmentof
theactivationdistance,seeAppendixA—
AdjustingYourAutoFlush®.
TheAutoFlush®unithasa7minutestart-up
sequenceinwhichtheObjectLockSensorwill
activatetheUser-In-Viewgreen L.E.D. continu-
ouslyaslongasauserorobjectisinview. After
thestart-upsequenceiscompletedandwhenthe
ObjectLockSensorhasauserinview,theUser-In-
Viewgreen L.E.D.willflash3timesoncetheuser
isinfrontoftheunitforaminimumof5seconds.
This preventsneedlessflusheswhensomeone
walksby.
ACTIVATION
USER-IN-VIEWL.E.D. (Greenlightflashes3times,after
5seconddelay,whenauserisinview. Thegreenlight
flashesconstantlywhenauserisinviewduring
the7minutestartupsequence).
OBJECTLOCKSENSOR
(Detectsuserorobject).
BATTERYL.E.D. (Yellowlightflashes
indicatingitistimetoreplace
batterieswith4new“C”cellalkalinebatteries).
COURTESYMANUALFLUSHBUTTON
(Allowsmanualactivationof
flushwhenneeded—Toilet
modelonly).
VISUALINDICATORGUIDE
1
ON
2
2.1
2.2
2.3
SpanishandFrench instructionsareavailableatwww.technicalconcepts.com
InstrucciónesenFrancesy en Españolestarandisponiblesen la paginawww.techicalconcepts.com
Lesinstructionssont disponibles enfrancais et enespagnolsurnotre site web;www.technicalconcepts.com
Step2.
Popular Toilet manuals by other brands

IFO
IFO Spira 6260 Operating and maintenance

Delabie
Delabie 130200 manual

Dometic
Dometic 310 Series instruction manual

Geberit
Geberit AQUACLEAN MERA COMFORT user manual

American Standard
American Standard Right Height Elongated Toilet Triumph Cadet... INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

Kallista
Kallista P70080-00 installation guide