5. Only on housings with heater system.
Perform the input and output (to the
camera) voltage connections using the PCB
installed inside the housing near the rear
flange.
. Only on housings with wiper system
Perform wiper electrical connections
through the three coloured wires connected
to the wiper mechanism mounted on the
rear flange.
odel with wiper voltage 110-240 VAC
Permanent 110-240 VAC voltage must be
connected between the BLUE wire (line) and
the WHITE wire (neutral). To activate the
wiper, connect the GREEN wire to the BLUE
wire. A normally open switch, connected
between GREEN and BLUE, can be used for
this operation.
When the voltage is connected to the GREEN
wire, the wiper works and continues to work
until the voltage is disconnected, then it
goes back to its initial position.
odel with wiper voltage 24 VDC (default
model)
Permanent 24VDC voltage must be
connected between the GREEN wire (+24V)
and the GREY wire (GND). To activate the
wiper, connect the BLUE wire to the GREY
wire (GND) An external switch (normally
open), connected between GREY and BLUE,
can be used for this operation.
When the BLUE wire is connected to GND
(GREY), the wiper works and continues to
work until the wire in disconnected, then it
goes back to its initial position.
Wiper wires
4/5