TECSYSTEM TRBH User manual

2
TRBH SYSTEM
PAGE
1) CONTROL BOX SAFETY REGULATIONS
……….........................................
3
2) FANS SAFETY REGULATIONS
……….........................................
4
3) CONTROL BOX TECHNICAL SPECIFICATIONS
…………………………………..
5
4) FANS/BARS TECHNICAL SPECIFICATIONS
…………………………………..
6
5) TRBH SYSTEM PRESENTATION
…………………………………..
7
6) SYSTEM COMPONENTS
…………………………………..
8
7) CONTROL BOX ASSEMBLY
…………………………………..
9
8) BAR AND FANS ASSEMBLY
…………………………………..
10
•ASSEMBLY NOTES
…………………………………..
12
•ENVIRONMENTAL CONDITIONS OF USE
…………………………………..
--
•MAINTENANCE
…………………………………..
--
9) TRBH SYSTEM CONFIGURATION SELECTION
…………………………………..
--
10) ELECTRICAL CONNECTIONS
…………………………………..
13
•CONTROL BOX POWER SUPPLY
…………………………………..
14
•CONTROL BOX CONTROL UNIT ELECTRICAL
CONNECTIONS
…………………………………..
--
•CONTROL BOX B1 CONTROL BOX B2 ELECTRICAL
CONNECTIONS
………………………………….
--
•FANS CONTROL BOX ELECTRICAL CONNECTIONS
…………………………………..
15
•CONNECTION NOTES
…………………………………..
20
11) FANS TEST
…………………………………..
--
12) FAN DIAGNOSTICS
…………………………………..
21
13) TG180BH-TG360BH-TG500BH FANS DIMENSIONS
…………………………………..
--
14) 1200BH-1800BH-3600BH BARS DIMENSIONS
…………………………………..
22
15) WARRANTY REGULATIONS
......................................................
23
16) TROUBLESHOOTING
…………………………………..
24
17) EQUIPMENT DISPOSAL
……………………………………………
--
18) USEFUL CONTACTS
……………………………………………
--
INTRODUCTION
TABLE OF CONTENTS
First of all we wish to thank you for choosing to use a TECSYSTEM product and we strongly suggest that you read this
instruction manual carefully: You will understand the use of the equipment and therefore be able to take advantage of all its
functions.
ATTENTION! THIS MANUAL IS VALID AND COMPLETE FOR THE TRBH SYSTEM.

3
TRBH SYSTEM
CONTROL BOX SAFETY REGULATIONS
ATTENTION:
Read the manual carefully before starting to use the control unit. Keep the instructions for future reference.
Do not open the device, touching any internal components can cause electric shock. Contact with a voltage over 50
Volts can be fatal. To reduce the risk of electric shock, do not dismantle the back of the device for any reason. Moreover its
opening would void the warranty.
Before connecting the device to the power supply, make sure that all the connections are correct. Powering the
control box / fans lines, with the control unit NT935 disconnected / faulty or with the fan data cable disconnected /
faulty, the SAFETY SPEED function is enabled. The speed safety function automatically starts the fans at speed 5,
do not touch the running fans, risk of injury. Always disconnect the unit from the supply before any cabling modification.
Any work on the equipment must be entrusted to a qualified engineer.
Failure to comply with these instructions can cause damages, fires or electric shock, and possible serious injuries!
POWER SUPPLY
Before using it, make sure the power cable is not damaged, knotted or pinched. Do not tamper with the power cable. Never
disconnect the unit by pulling thecable, avoid touching the pins. Do not carry out any operations of connecting/disconnecting
with wet hands. To disconnect the device, do not use objects such as levers. Disconnect the power supply immediately if you
notice that the device gives off a burning smell or smoke: contact the assistance.
LIQUIDS
Do not expose the equipment to splashes or drops, do not position it in places with humidity exceeding 90% and never touch
with wet hands. If any liquid penetrates the control unit, disconnect it immediately and contact technical service.
CLEANING
Disconnect the power cable before cleaning the control unit, use a dry cloth to dust it, without any solvent or detergents, and
compressed air.
OBJECTS
Never insertany objects intothecracks of thecontrolunit. If this happens, disconnectthecontrol unit and contact anengineer.
USE RESERVED TO QUALIFIED PERSONNEL
The purchased goods are a sophisticated electronic device that is totally unsuitable to be used by non-qualified personnel.
Any work must be carried out by a specialist engineer.
ACCESSORIES
The use of non-original accessories or spare parts can damage the unit and endanger users' safety. In the event of faults,
contact technical service.
POSITIONING
Install the control unit indoors, in a place protected from water splashes and from the sun’s rays. Do not place near heat
sources exceeding the parameters stated in this manual. Position on a stable surface, far from any possible vibrations.
Position the unit as far as possible from any intense magnetic fields.
REPAIRS
Do not open the control unit. For any fault, always use qualified personnel. The opening of the control unit and/or the removal
of the series identifying label entails the automatic forfeiture of the warranty. The Warranty seal is applied to all devices, any
attempt to open the unit would break the seal and cause the consequent automatic forfeiture of the warranty.
TECHNICAL INFORMATION
Mail: ufficiotecnico@tecsystem.it - tel: 02/4581861

4
TRBH SYSTEM
FANS SAFETY REGULATIONS
ATTENTION:
Read the manual carefully before starting to use the fans. Keep the instructions for future reference.
Do not touch/disassemble the bar or the fans while they are in operation: RISK OF INJURY.
The product must be installed in a place with access limited to qualified personnel only. Any work on the equipment
must be entrusted to a qualified engineer.
Do not touch the motor or the power cables. Contact with a voltage over 230 Volts AC can be fatal. To reduce
the risk of electric shock, do not dismantle or modify the fan motor for any reason.
Before connecting the system to the power supply, make sure that all the connections are correct. Powering the
control box / fans lines, with the control unit NT935 disconnected / faulty or with the fan data cable disconnected
/ faulty, the SAFETY SPEED function is enabled. The speed safety function automatically starts the fans at speed
5, do not touch the running fans, risk of injury. Always disconnect the fan from the power supply before performing
any type of maintenance.
Never touch the motor, danger of burns: RISK OF INJURY.
POWER SUPPLY
Before using it, always make sure the power cable is not damaged, knotted or pinched. Do not tamper with the power
cable. Never disconnect the unit by pulling the cable, avoid touching the pins. Do not carry out any operations of
connecting/disconnecting with wet hands. Do not use items such as levers to disconnect the system power supply.
Immediately disconnect the device if there is a smell of burning or smoke. Contact the Tecsystem technical assistance.
LIQUIDS
Do not expose the product to dripping or splashing liquids. Do not place in places with humidity over 90% and never
touch with wet or damp hands.
CLEANING
Before cleaning the fan, always disconnect the power cord. To avoid malfunctions only use compressed air to remove
dust and dirt. Do not use lubricants or greases of any kind.
OBJECTS
Never insert objects into the air inlet or outlet, if this happens disconnect the fan and contact a technician.
USE RESERVED TO QUALIFIED PERSONNEL
The purchased product is a sophisticated electro-mechanical device that must neverbe used by non-qualified personnel.
Any work must be carried out by a specialist engineer.
ACCESSORIES
Do not use non-original accessories or spare parts, it could cause damage to the fan and compromise the safety of the
user. In case of faults, contact technical assistance.
POSITIONING
Install the fans indoors, in a place protected from water splashes and from the sun’s rays. Do not place it near sources
of heat
above the parameters indicated in this manual. Place horizontally and on stable surfaces. The product must
be installed in a place with access limited to qualified personnel only.
REPAIRS
Do not repair or modify the fan yourself. For any fault, always use qualified personnel. Opening or tampering with the fan
will automatically invalidate the warranty.
PRODUCTION
The date and the production batch of the product are shown on a label placed on the fan. Removal of the label
entails the automatic forfeiture of the warranty.
TECHNICAL INFORMATION OR REPORTING INFORMATION
Mail: ufficiotecnico@tecsystem.it - tel: +39 024581861

5
TRBH SYSTEM
CONTROL BOX TECHNICAL SPECIFICATIONS
POWER SUPPLY
Nominal values for the BH motor line power supply
230Vac 50/60Hz
Range 187-265Vac
50/60Hz
Direct connection with the Power-link source from the thermometric control unit
12VDC 30mA max
INPUTS
Digital input for connection with the BH control units (BLDC IN)
●
OUTPUTS
3 digital outputs to manage and control motors B1 (M1-M2-M3) and B2 (M4-M5-M6)
●
3 LN outputs for motors B1 (M1-M2-M3) and B2 (M4-M5-M6)
230Vac 50/60Hz
Range 187-265Vac
50/60Hz
1 digital output for control box B1-B2 (BLDC OUT)
12VDC
DIMENSIONS
106x108 depth.53.50mm
Din rail
TESTS AND PERFORMANCE
Construction in compliance with CE regulations
●
Protection from electrical interference EN 61000-4-4
●
Ambient operating temperature from –20°C to +70°C
●
Humidity 90% non-condensing
●
IP20 degree of protection
●
Housing UL 94V0 self-extinguishing Blend PC/ABS
●
Fan fault self-diagnosis circuit
●
Motor operation test key
●
Connections on removable terminal boards
●
Protection treatment of the electronic part
Optional

6
TRBH SYSTEM
BARS TECHNICAL SPECIFICATIONS
MODEL
1200BH
1800BH
3600BH
FAN MODEL
TG180BH
TG360BH
TG500BH
BAR LENGTH
1400 mm
1800 mm
2300 mm
MAX FLOW RATE
1350 mᶟ/h
2640 mᶟ/h
3000 mᶟ/h
FAN GENERIC TECHNICAL SPECIFICATIONS
POWER SUPPLY
Supply rated values
230Vac
50/60Hz
Min and Max. supply values
187÷265Vac
50/60Hz
Max absorption (speed S10)
95Watt
(TG500)
Power consumption in standby
500mWatt
INPUTS
Digital input for the control box connection
●
TESTS AND PERFORMANCE
Ambient operating temperature from as indicated in the standard IEC 60076-11
●
IP40 degree of protection
●
Min and max speed (rpm)
1500-2800
Motor protection: input fuse, thermal protection, current limiter, mechanical overload
●
EMC reference standard: EN61000-6-3, EN61000-6-2 and EN 61000-3-2
●
TECHNICAL SPECIFICATIONS OF FANS FOR MODEL
MODEL
TG180BH
TG360BH
TG500BH
FAN LENGTH
180 mm
360 mm
500 mm
FAN DIAMETER
80 mm
80 mm
80 mm
MAX CURRENT
0.34A
0.55A
0.74A
MAX POWER
45W
75W
95W
FLOW RATE
450 mᶟ/h
880 mᶟ/h
1000 mᶟ/h

7
TRBH SYSTEM
TRBH SYSTEM PRESENTATION
The TRBH SYSTEM, installed on the resin transformers, will allow thermoregulation of the single phase U-V-W of the
transformer. Activation of the ventilation system and the regulation of the air flow of the fans will be managed by the
thermometric control unit models: NT935BH-D and NT935BH-ETH.
The activation and shutdown of the ventilation system, programmable on the thermometric devices, they will be anticipated
by 10° C with respect to the FAN1 ON threshold (programmed on CH1-CH2-CH3): ON speed S1 and OFF speed S0,
maximum speed S10 will reach at the threshold value of FAN1 ON.
E.g. threshold programming FAN1 ON 70°C
•Activation of ventilation system TRBH ON 61°C, speed (rpm) fan S1.
•Switch off ventilation system TRBH ON 60°C, speed (rpm) fan S0
The speed regulation (rpm) on the fans is divided into 10 steps in relation to the temperature detected on the CHF channel
and to the FAN 1 ON value.
E.g. programming of the threshold FAN1 ON 70°C, the fan speed will progressively increase in relation to the temperature
detected on the individual channel, see table example speed CH1.
table example speed CH1
Temperature CH1
Motor S and Rpm Speed
Fan flow rate mᶟ/h
TG180BH
TG360BH
TG500BH
60°C
S0 = OFF
OFF
OFF
OFF
61°C
S1 = 1500
220
430
507
62°C
S2 = 1650
245
455
567
63°C
S3 = 1780
265
535
617
64°C
S4 = 1925
295
580
650
65°C
S5 = 2075
335
630
710
66°C
S6 = 2220
370
700
775
67°C
S7 = 2365
390
750
850
68°C
S8 = 2500
410
795
890
69°C
S9 = 2650
430
850
960
70°C
S10/full Speed = 2800 rpm
450
880
1000
NOTE: The speed regulation on the installed fans, with reference CH2 and CH3, will be managed in relation to the
temperature increase on the relative channel (selections B2-M3 and B1-M3).
The TRBH system will introduce the following advantages into your system:
•Containment of thermal and mechanical shock
•Stress reduction of the ventilation system
•Reduction in ventilation system consumption
•Reduction of noise emitted by the fans on average
•Motor fault identification and signalling
•Fan speed regulation
•Custom configuration of the ventilation system
•Fan protection for ambient overheating
In relation to the number of fans installed, the TRBH system provides for the possibility of programming the number of
connected bars (B1 - B2) and the number of fans on the single bar using the thermometric control unit.

8
TRBH SYSTEM
SYSTEM COMPONENTS
Temperature control unit versions:
•NT935BH-D
•NT935BH-ETH
Control box CB3-BH
•B1 management bar 1 (M1-M2-M3)
•B2 management bar 2 (M4-M5-M6)
Fans
•TG180BH
•TG360BH
•TG500BH
BH bar

9
TRBH SYSTEM
CONTROL BOX CB3-BH ASSEMBLY
Attach the device to the DIN rail and make the connections to the removable terminal blocks.
The following components are available for each control box:
Control Box device dimensions
Control box CB3-BH cod: 1AC0078
Quick start guide and QR code
Bar identification labels B1 - B2
1 Terminal 3 poles pitch 5 supply
Code: 2PL0367 - Screws tightening torque 0.5Nm
2 Terminals 3 poles pitch 3.81 control box IN/OUT
Code: 2PL0366 - Screws tightening torque 0.25Nm
1 Terminal 12 poles pitch 3.81 motor control line
Code: 2PL0420 - Screws tightening torque 0.25Nm
1 Terminal 6 poles pitch 5 motor power line
Code: 2PL0372 - Screw tightening torque 0.5Nm
ATTENTION: always install the device using the terminals included in the pack.
The use of terminals other than those included in the control unit could cause malfunctions.
1MN0165 REV.0

10
TRBH SYSTEM
BAR AND FANS ASSEMBLY
Position the two profiles on the sides of the transformer (BAR 1-BAR 2).
Prepare the bar on the transformer trolley and centre the positioning of the bar using the central column of the
transformer as a reference.
Fix the bar on the transformer trolley using the appropriate fixing slots, suggested M8 bolts plus washer.
Position the fans on the bar, centre each individual fan with the U-V-W reference column.
1MN0193 REV.0
1MN0194 REV.0
1MN0192 REV.0
U
V
W

11
TRBH SYSTEM
Use the dedicated slots on the bar and the self-drilling screws, supplied, to lock the fans in the desired position.
Use the fan flappers to correctly direct the air inside the transformer columns.
ATTENTION: always maintain a safe distance from the windings, indicated by the transformer
manufacturer.
1MN0195 REV.0
Air flow direction inside the transformer
1MN0195 REV.0

12
TRBH SYSTEM
TRBH SYSTEM CONFIGURATION SELECTION
The customised configuration of the ventilation system provides for the possibility of programming, by means of the
NT935BH temperature control unit, the number of bars connected (B1 - B2) and the number of fans on the single bar. The
following configurations BARS - FANS can be selected:
1) B1-M1/1 bar (B1) 1 fan (M1) connected
HOT speed regulation reference channel (the hottest channel of CH1-CH2-CH3)
2) B1-M2/1 bar (B1) 2 fans connected (M1-M2)
Reference channel for HOT speed regulation (the hottest channel of CH1-CH2-CH3)
3) B1-M3/1 bar (B1) 3 fans connected (M1-M2-M3)
Single speed regulation reference channel CH1 (M1) CH2 (M2) CH3 (M3)
4) B2-M1/2 bars (B1-B2) 2 fans connected (M1-M6)
Reference channel for HOT speed regulation (the hottest channel of CH1-CH2-CH3)
5) B2-M2/2 bars (B1-B2) 4 connected fans (M1-M2-M5-M6)
Reference channel for HOT speed regulation (the hottest channel of CH1-CH2-CH3)
6) B2-M3/2 bars (B1-B2) 6 fans connected (M1-M2-M3-M4-M5-M6)
Reference channel for single speed regulation CH1 (M1-M6) CH2 (M2-M5) CH3 (M3-M6)
NOTE: the fan speed adjustment (rpm), with sections other than B1-M3 and B2-M3, is managed with HOT reference
channel or the hottest channel of CH1-CH2-CH3.
In order to avoid malfunction signals, it is advisable to make the TRBH system connections respecting the selected
configuration, see control box - fans connections from page 15.
E.g. B1-1 = 1 bar B1 (only control box B1) and 1 fan connected M1 (only fan M1 connected).
Make the connections between the control unit and box (B1) and between the box (B1) and the M1 fan.
ASSEMBLY NOTES
Fix the fans on the bar using the dedicated holes on the back. Do not modify the fan fixing holes.
During fan movement, avoid deforming the impeller fins. Never change the position of the motor.
If the fan/bar is mounted on a transformer the fan's working position must
respect the safety distance indicated in the manual of the transformer on which you are installing the fan. The fan must be
positioned in a horizontal plane; always check, with the help of a spirit level, that the fan is positioned correctly.
The maximum level of vibration permitted is 60Hz.
ENVIRONMENTAL CONDITIONS OF USE
Absence of fine dust.
Absence of flammable or corrosive gases.
Relative humidity: 90% non-condensing (for short periods).
NB: maximum temperature as prescribed by the IEC 60076-11 standard.
Avoid installing it in a marine environment, except after specific treatment of the metal parts.
NOTE: failure to comply with the assembly notes and any use in critical environmental conditions
such as: long periods of standstill, high humidity, high temperatures, excessive dust and excessive vibration,
can hasten deterioration of the mechanical parts of the fans.
MAINTENANCE
In order to maintain the efficiency of the fans, periodically perform (every 6 months) a cleaning intervention on them, using
only compressed air. Do not use lubricants or greases of any kind.
Prolonged shutdown of the fan could be the cause of faults. The installation of the fans combined with the Tecsystem
thermometric control units avoids any prolonged stops. Enabling the HFN function present in the Tecsystem control units
it is possible to program activation cycles of the fans from 1 to 200 hours, recommended setting every 24 hours (for further
information on the HFN function, check the manual of the control unit purchased).
NOTE: Periodic maintenance and activation of the HFN will contribute to extending the efficiency of the fans.
Maintenance work on the fans must be programmed according to the environmental conditions in which they
operate.

13
TRBH SYSTEM
ELECTRICAL CONNECTIONS
1)
Power supply 230 VAC 50/60Hz fans
M1-M2-M3 (M4-M5-M6)
4)
Digital connection INPUT control unit BH and
control box power supply
2)
Power supply 230 Vac 50/60 Hz fan line
5)
Bar earthing.
3)
Digital connection OUTPUT control box
2 BLDC bar.
6)
Digital connection of M1-M2-M3 fans (M4-M5-
M6).
4
1
2
4
4
3
ATTENTION: Before making the electrical connections on the control boxes it is advisable to
identify the two bars with CONTROL BOX BAR B1 and CONTROL BOX BAR B2, using the
supplied labels.
The identification of the two bars will be used to define the connections of the two boxes and of the
fans (M1-M2-M3-M4-M5-M6) associated with the channels CH1-CH2-CH3.
ATTENTION:
powering the power
motors supply inlet of
the control box, the
power line outlets
B1 M1-M2-M3
B2 M4-M5-M6
will be energised. Do
not touch risk of injury
BOX B1
BOX B2
1MN00165 REV.0
5
6
ATTENTION:
The earthing of the bar
(5) must always be
connected to the earth of
the system.
To allow correct
operation of the system,
always connect the
shields of the signal
cables to the earth on
the side of the bar only.
1MN0179 REV.0

14
TRBH SYSTEM
If an existing control unit needs to be replaced with a new one, in order to guarantee its safe and correct operation,
the connection terminals must be replaced with the new data terminals supplied.
CONTROL BOX POWER SUPPLY
The control box has two dedicated power supplies:
•Digital power supply, input inlet, 12VDC 30mA max; it is used for the management and control of the control box.
The digital power supply is supplied directly from the B1 thermometer control unit and from the B1 control box to
the B2 bar control box, see connections, control unit - control box B1and control box B1 - control box B2 reported
below.
•Power supply for 230Vac 50/60Hz motors, it is used to power the B1 M1-M2-M3 box fans or the B2 M4-M5-M6
box fans. The earthing cable must always be connected to the earthing terminal .
ELECTRICAL CONTROL UNIT CONTROL UNIT - CONTROL BOX B1
The electrical connection between the NT935 temperature control unit and the B1 control box must be performed between:
the FAN1 BLDC output (B1-B2-B3-B4) of the control unit and the IN control box B1 input (B1-B2-B3-B4)
ELECTRICAL CONNECTIONS CONTROL BOX B1 - CONTROL BOX
B2
BOX B1
NT935
BOX B1
BOX B2
The electrical connection between control box B1 and control box B2 must be performed between: output OUT (B1-B2-
B3-B4) of control box B1 and input IN control box B2 (B1-B2-B3- B4).
NOTE: connection only available in configurations with two bars B1 and B2 (B2-1- B2-2- B2-3).
1MN0165 REV.0
1MN0165 REV.0

15
TRBH SYSTEM
ELECTRICAL CONNECTIONS CONTROL BOX - BH FANS
The TG180BH-TG360BH-TG500BH motors have two cables, 250mm long, dedicated to the connection between the
fan and the control box:
➢A) Motor power supply connection: 3-pole female connector, 2x0.75 h05vvf cable with 6mm external
diameter and BLACK colour
➢B) digital connection of motor signals: 4-pole female connector, 4x0.35 liyy cable with 4.9mm external
diameter and GREY colour.
1MN0181 REV.0
A
B
Connector A: motor
power supply.
- pin 1 neutral - blue
- pin 2 phase - brown
- pin 3 nc.
Connector B: digital signals for
motor signals.
- pin 1 - white
- pin 2 - brown
- pin 3 - blue
- pin 4 - black
The connections between the control box and the individual fans must be made using the cables supplied with the
universal bar. Fan power cable and digital cable motor signals.
1MN0180 REV.0
Motor power cable
- pin 1 neutral - blue
- pin 2 phase - brown
- pin 3 nc.
BH motor signals digital cable
- pin 1 - white
- pin 2 - brown
- pin 3 - blue
- pin 4 - black
NOTE: depending on the bar purchased, it is possible to request the cable kit 1200BH-1800BH-3600BH.

16
TRBH SYSTEM
Connect the motor connector A, of the single fan, with the relative motor power
cable to the MOTORS POWER LINE output of the control box.
B1 bar motor power supply
B2 bar motor power supply
BOX B1
BOX B2
The electrical connections of the two bars B1 and B2 depend on the configuration of the TRBH system selected
(programmed on the thermometric control unit).
1) In the B2-M3 configuration, 2 bars (B1-B2) 6 fans connected (M1-M2-M3-M4-M5-M6), the positioning and connection
of the fans must absolutely respect what is shown in the image below:
ATTENTION: incorrect positioning or
connection of the fans could result in
anomalies in operation of the TRBH
system.
Connect the B motor connector of the single fan, with the relative digital cable motor signals to the MOTORS CONTROL
LINE output of the control box.
B1 bar digital connection:
B2 bar digital connection:
M1
M2
M3
1 White
2 Brown
3 Blue
4 Black
5 White
6 Brown
7 Blue
8 Black
9 White
10 Brown
11 Blue
12 Black
M1
M2
M3
~ Brown
~ Blue
~ Brown
~ Blue
~ Brown
~ Blue
M4
M5
M6
~ Brown
~ Blue
~ Brown
~ Blue
~ Brown
~ Blue
After making all the connections of the individual fans, connect the 230Vac 50/60Hz fan lines
to the MOTORS POWER SUPPLY input of both control boxes (B1-B2) .
M4
M5
M6
1 White
2 Brown
3 Blue
4 Black
5 White
6 Brown
7 Blue
8 Black
9 White
10 Brown
11 Blue
12 Black
2) In the B2-M2 configuration, 2 bars (B1-B2) + 4 connected fans (M1-M2-M5-M6), the positioning and connection of
the fans must absolutely respect what is shown in the image below:
BOX B1
BOX B2
ATTENTION: incorrect positioning or
connection of the fans result in
anomalies in operation of the TRBH
system.

17
TRBH SYSTEM
Connect the motor connector A, of the single fan, with the relative motor power
cable to the MOTORS POWER LINE output of the control box.
B1 bar motor power supply
B2 bar motor power supply
Connect the B motor connector of the single fan, with the relative digital cable motor signals to the MOTORS CONTROL
LINE output of the control box.
B1 bar digital connection:
B2 bar digital connection:
M1
M2
~ Brown
~ Blue
~ Brown
~ Blue
M5
M6
~ Brown
~ Blue
~ Brown
~ Blue
M1
M2
1 White
2 Brown
3 Blue
4 Black
5 White
6 Brown
7 Blue
8 Black
After making all the connections of the individual fans, connect the 230Vac 50/60Hz fan lines
to the MOTORS POWER SUPPLY input of both control boxes (B1-B2) .
3) In the B2-M1 configuration, 2 bars (B1-B2) + 2 connected fans (M1-M6), the positioning and connection of the fans
must absolutely respect what is shown in the image below:
ATTENTION: incorrect positioning or
connection of the fans result in
anomalies in operation of the TRBH
system.
M5
M6
5 White
6 Brown
7 Blue
8 Black
9 White
10 Brown
11 Blue
12 Black
BOX B2
BOX B1
Connect the motor connector A, of the single fan, with the relative motor power
cable to the MOTORS POWER LINE output of the control box.
B1 bar motor power supply
B2 bar motor power supply
After making all the connections of the individual fans, connect the 230Vac 50/60Hz fan lines
to the MOTORS POWER SUPPLY input of both control boxes (B1-B2).
M1
~ Brown
~ Blue
M6
~ Brown
~ Blue

18
TRBH SYSTEM
Connect the B motor connector of the single fan, with the relative digital cable motor signals to the MOTORS CONTROL
LINE output of the control box.
B1 bar digital connection:
B2 bar digital connection:
M1
1 White
2 Brown
3 Blue
4 Black
M6
9 White
10 Brown
11 Blue
12 Black
4) In configuration B1-M3, 1 bar (B1) + 3 fans connected (M1-M2-M3), the positioning and connection of the fans must
absolutely respect what is shown in the image below:
ATTENTION: incorrect positioning or
connection of the fans result in
anomalies in operation of the TRBH
system.
Connect the motor connector A, of the single fan, with the relative motor power
cable to the MOTORS POWER LINE output of the control box.
B1 bar motor power supply
M1
M2
M3
~ Brown
~ Blue
~ Brown
~ Blue
~ Brown
~ Blue
After making all the connections of the individual fans, connect on the MOTORS POWER
SUPPLY input of the B1 bar supply 230Vac 50/60Hz fan lines.
Connect the B motor connector of the single fan, with the relative digital cable motor signals to the MOTORS CONTROL
LINE output of the control box.
B1 bar digital connection:
M1
M2
M3
1 White
2 Brown
3 Blue
4 Black
5 White
6 Brown
7 Blue
8 Black
9 White
10 Brown
11 Blue
12 Black
BOX B1

19
TRBH SYSTEM
5) In configuration B1-M2, 1 bar (B1) + 2 fans connected (M1-M2), the positioning and connection of the fans must
absolutely respect what is shown in the image below:
ATTENTION: incorrect positioning or
connection of the fans result in
anomalies in operation of the TRBH
system.
Connect the motor connector A, of the single fan, with the relative motor power
cable to the MOTORS POWER LINE output of the control box.
B1 bar motor power supply
After making all the connections of the individual fans, connect the 230Vac 50/60Hz fan lines
to the MOTORS POWER SUPPLY input of both control boxes (B1-B2) .
M1
M2
~ Brown
~ Blue
~ Brown
~ Blue
Connect the B motor connector of the single fan, with the relative digital cable motor signals to the MOTORS CONTROL
LINE output of the control box.
B1 bar digital connection:
M1
M2
1 White
2 Brown
3 Blue
4 Black
5 White
6 Brown
7 Blue
8 Black
6) In configuration B1-M1, 1 bar (B1) + 1 fan connected (M1), the positioning and connection of the fan must absolutely
respect what is shown in the image below:
ATTENTION: incorrect positioning or
connection of the fans result in
anomalies in operation of the TRBH
system.
BOX B1
BOX B1

20
TRBH SYSTEM
NOTES: DIGITAL SIGNAL CONNECTIONS
All signal transport cables, components of the TRBH system (connections between: temperature control unit, control box
(B1), control Box (B2) and fans), must strictly respect the following rules:
• be separated from those of power
• be created with shielded and cable with twisted conductors
• have a section of at least 0.25 mm²
• be firmly fixed in the terminal blocks
• have the conductors tinned or silvered
NOTE: the use of cables not complying with the above could cause possible reading anomalies. It is very
important to always bear in mind that any disturbance on the signal lines could be the cause of anomalies.
FANS TEST
Pressing the test button of the single control box, it is possible to start the fan
test.
During the fan test the control box will activate in sequence, for approximately
10 seconds on a fan, the M1 - M2 - M3 fans connected to the single bar.
The function test of the fans has the purpose of verifying the correct positioning
and wiring of the installed fans.
Connect the motor connector A, of the single fan, with the relative motor power
cable to the MOTORS POWER LINE output of the control box.
B1 bar motor power supply
After making all the connections of the individual fans, connect the 230Vac 50/60Hz fan lines
to the MOTORS POWER SUPPLY input of both control boxes (B1-B2) .
Connect the B motor connector of the single fan, with the relative digital cable BH motor signals to the MOTORS
CONTROL LINE output of the control box.
B1 bar digital connection:
M1
~ Brown
~ Blue
M1
1 White
2 Brown
3 Blue
4 Black
TEST KEY
Table of contents
Other TECSYSTEM Control System manuals

TECSYSTEM
TECSYSTEM VRT300 Series User manual

TECSYSTEM
TECSYSTEM NT935 WS User manual

TECSYSTEM
TECSYSTEM T119 Manual

TECSYSTEM
TECSYSTEM VRT600 SERIES User manual

TECSYSTEM
TECSYSTEM FO 935 User manual

TECSYSTEM
TECSYSTEM NT538 User manual

TECSYSTEM
TECSYSTEM VRT600 SERIES User manual

TECSYSTEM
TECSYSTEM NT311 ETH User manual

TECSYSTEM
TECSYSTEM FO 935 ETH User manual

TECSYSTEM
TECSYSTEM T30 User manual