TeeJet 814 User manual

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 1of 15
Tee
J
et®
814
Sprayer Monitor
Progra mming and Operat ing Ma nua l
(v2.10 A)
98-70013-R0

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 2of 15
Table of Cont e nts
Progra mming Guidelines ______________________________________________________________3
Start __________________________________________________________________________________4
System Se tup Mode ___________________________________________________________________5
Speed Sensor Calibration ________________________________________________________________ 5
Simulated Speed _______________________________________________Error! Bookmark not defined.
Flow Meter Calibration ___________________________________________________________________ 7
Section Width__________________________________________________________________________ 7
Pressure sensor calibration ______________________________________________________________ 8
Step 1______________________________________________________________________________ 8
Step 2______________________________________________________________________________ 8
Boom Control Valve Type _________________________________________________________________ 8
Completing the System Setup Mode ________________________________________________________ 9
Norma l M onit or Mode ________________________________________________________________1 0
Introduction __________________________________________________________________________ 10
Speed and Dose Rate___________________________________________________________________ 10
Dose rate and Pressure_________________________________________________________________ 10
Flow and Pressure_____________________________________________________________________ 10
Sprayed area and sprayed volume ________________________________________________________ 11
Working width ________________________________________________________________________ 11
Ope rat ing I nstruc tions _______________________________________________________________12
Sprayer Checkout _____________________________________________________________________ 12
The Spraying Operation_________________________________________________________________ 12
Automat ic Pow er Dow n ______________________________________________________________13
Appendix A: Ove rvie w of Monitor Displays____________________________________________1 4
Appendix B: Overview of Programm ing Ste ps ________________________________________15

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 3of 15
Progra m m ing Guidelines
Make sure that all hardware components are properly installed and tested. Before you start
the programming process you should first check if the Console and all sensors are working
properly.
Important Preliminary Information
Before you begin, we recommend that you review the following Programming Guidelines that
control the programming process:
*The Pro key is used for power ON
*Clr + Up + Down key combination is used to power OFF (when not spraying)
*Holding Pro key for 3 seconds is used to enter or exit the programming mode
*Shortly pressing the Pro key saves the current parameter and advances to the next
programming step
*Shortly pressing the Clr key restores the parameter with the default value
*Holding the Clr key restores the parameter with its minimum value (mostly zero)
*The value of a parameter is changed with the Up and Down keys. Holding the Up or
Down key changes the parameter rapidly.

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 4of 15
St a rt
To begin the programming process:
*Read above for programming tips.
*Be sure the Master switch is “OFF.”
*Turn console “ON” by pressing the Pro key. When the Control Console is turned on, the
software version will be displayed for approximately 5 seconds.
This information will be needed when calling for service support.
814 US V2.10A
Example : the 814-spray monitor is working in US units and the software version is
V2.00A.
*After a short time the Console will change to the normal monitor mode.
0.0 MPH 0 GPA

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 5of 15
Syst e m Se t up Mode
The System Setup Mode contains the programming steps that customize the monitor to the
sprayer or sprayer components. These include calibration steps and parameters that, once
programmed, will likely never change. An overview of all programming steps is shown in
“Appendix B: Overview of Programming Steps”.
To enter the System Setup Mode:
*First be sure that the Console is ON (if not put it on by pressing the Pro key and wait until
the normal display is visible).
*Check if the Master switch is OFF
*Then press and hold the Pro key to enter the System Setup Mode.
SELECT ING UNITS
Default = US
>US units
Select the units that the monitor will be operating in. Select US units for English measurement
units or select SI units for metric measurement units.
Depress the
P
RO
key to accept the flow meter value and advance to the next program step.
SPEED SENSOR CALI BRATION
Default = 250 pulses/300 ft (100m)
>250 puls/300 ft
The speed sensor needs to be calibrated in order to provide the proper speed and area
readings. The value for this step is the number of pulses generated by the speed sensor in
300 ft (100 meters).

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 6of 15
Manual Calculation
To manually calculate the proper value for Wheel Speed Sensor pulses, you need to know the
circumference of the wheel to which the sensor is mounted. It can be measured by marking
the tire and measuring the distance covered as that mark makes one full revolution.
Then use the following formula:
480
30
4600,3
..
#600,3=
×
=
×ge
inchesinnceCircumfereWheel
wheelonmagnets
Use the Up or Down keys to adjust the value. Press the Pro key to validate the value and
advance to the next programming step.
Note: The wheel calibration should be repeated if you are changing to another wheel
diameter. If a radar calibration number is to be entered manually, the Clr key must be
pressed so that the r is displayed with the calibration number
Auto calibration
The speed sensor can be automatically calibrated by driving 300ft. The console will
automatically detect a RADAR sensor (if used).
To start the auto calibration procedure, press simultaneously on the Up and Downkeys.
The display now will show :
Start auto cal
Now you have to drive to the starting point of the 300ft distance. Push the Up key to start
counting speed pulses. Drive 300ft and press Up key again to stop the pulse counting.
Drive300ft 176
Note: During the pulse counting the Speed Indication LED will be flashing.
Press the Up key when crossing the end point of the 300ft course. The number now on the
display is the number of pulses corresponding to 300ft.
223 puls/300ft
To accept the value and advance to the next step press the Pro key.
A radar speed sensor will be indicated with an "r" on the display e.g.
Drive300ft r 11

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 7of 15
The "r" will automatically appear during the auto calibration process when the console has
determined that a radar is being used. When manually entering a radar calibration number
the "r" must be turned on by pushing the Clr key. With this key you can toggle between radar
or wheel sensor. The calibrationvalue itself is adjusted with the Up and Down keys.
>r12.4puls/300ft
The auto calibration procedure can be escaped with the Pro or Clr keys. The console will then
return to the previous calibration value..
Note: The auto speed calibration should be repeated at least twice and an average of
the calibration numbers should be entered.
Simulated Speed
If you enter 0 in this programming step, then the Console always shows a simulated speed of
6 mph. This can be used to test out the sprayer at stand still. The simulated speed feature
allows you to check out the sprayer at a certain speed without actually moving the sprayer.
This can be done prior to any spraying activity.
Depress the
P
RO
key to accept the flow meter value and advance to the next program step.
FLOW METER CALI BRAT ION
Default = 650 pulses/liter
> 650 puls/l
First, locate the factory calibrated Flow Meter pulse rate tag on the Flow Meter. If this varies
from the default value of the console, use the Up and Down keys to modify the value.
Note: The Flow Meter Calibration number will always be expressed in pulses/l. The
monitor will automatically make the necessary conversion if operating in US units.
Depress the
P
RO key to accept the flow meter value and advance to the next program step.
SECTION WI DTH
Default = 10 ft (3.00 m)
In the next 9 programming steps the width of each section has to be entered. If a certain
section is not used then the value must be programmed to zero (i.e. If your sprayer only has 3
sections, only program values for the first 3 sections. All others should be set to 0).
Use the Up and Down keys to change the value.
> 10.0ft Sect 1

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 8of 15
Press the Pro key to save this parameter and to advance to the next section width. After
programming the ninth section, the Pro key advances to the next programming step.
Very Important
The section widths are used to calculate the treated acres (hectares) and the correct
application rate per acre (hectare). Therefore it must always be related to the effectively
sprayed area.
PRESSU RE SENSOR CALI BRATION
If you don’t have a pressure sensor connected to your system, you only have to program the
maximum pressure to zero in step 2.
If a pressure sensor is connected, it is calibrated with two programming steps. The first step
calibrates the sensor at 0 bar, while the second step calibrates the maximum pressure of the
sensor. The sensor can only be a 4 to 20 mA or 0 to 20 mA type.
Step 1
Default = 4.0 mA
In the first step the number of mA corresponding to 0 bar must be entered.
Use the Up and Down keys to change the value.
>4.0 mA 0.0 Bar
Press the Pro key to save this parameter and to advance to the next programming step.
Step 2
Default = 10.0 Bar
The second pressure calibration step specifies the maximum pressure of the sensor at
20mA.
If no pressure sensor is connected then zero must be entered in this step.
Use the Up and Down keys to change the value.
>10.0 Bar 20 mA
Press the Pro key to save this parameter and to advance to the next programming step
BOOM CON T ROL VALVE TYPE
Default = 2 Way
In this programming step, the type of section valve (2-Way or 3-Way) must be selected.
Use the Up and Down keys to change the value.
>2 Way

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 9of 15
This programming step is used to distinguish the type of on-off boom control valves you have
on your system. There are two types of valves that can be used, 2 -way control valves or 3 -way
control valves.
A 2-way control valve is simply an on/off valve. Flow is either directed to the boom section(s)
or it is blocked. A 3-way control valve is known as a by-pass valve. Flow continuously passes
through this valve. When the valve is activated (on), flow is directed to the boom section(s).
When the valve is not activated (off), flow is directed through a bypass port, back to the supply
tank.
If you are using the 3-way type of boom control valves in your system, change the value using
the Up and Down keys. Depress the Pro key to accept the value and advance to the next
programming step.
If the default value is correct, depress the Pro key to accept the value and advance to the next
programming step.
Note: If using 3-way, bypass boom control valves, refer to the instruction manual of
the valve you are using for proper calibration instructions. Every time you
change to another tip on the boom you should mechanically re-calibrate the
return flow of the boom control valves. If the boom section valves are
calibrated for the current tip on the boom then no further actions are
necessary on the controller (no calibration needed on the controller).
COM PLETIN G T HE SYST EM SET UP MODE
When you have completed the last calibration or programming step, you have completed the
System Setup Mode.
NOW, PRESS AND HOLD THE Pro KEY FOR THREE SECONDS AND THE CONSOLE
WILL RETURN TO THE NORMAL MONITOR MODE.
Note: For your protection, the 814 console will not automatically power down while
in the System Setup Mode. You must exit properly as described above to
enable the auto power down feature.
Note: Cutting the power to the controller while in the System Setup Mode will not
save any changes made into the computer’s memory.

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 10 of 15
Normal Monit or Mode
INT RODU CTI ON
The normal monitor mode is the normal working mode of the Console after power up.
The screen always shows one or two values at the same time (one on the left and/or one on
the right hand side). The displayed value can be recognized by the unit text string displayed
after the value e.g. the speed value is shown in MPH (km/h) units.
The usage of the keys during monitoring is summarized as follows:
*Pro key is used to power ON
*Clr & Down key combination is used to power OFF (when not spraying)
*Up and Down arrow keys are used for scrolling through the list of display information
*Holding Clr key is used to clear counters Ac, Gal (Ha, l)
In the following, the different monitor displays will be described in more detail. An overview is
given in “Appendix A: Overview of Monitor Displays ”.
SPEED AN D APPLICATION RATE
The default display is the speed and application rate display. On the left the current speed is
shown in MPH (km/h) and on the right hand side the current application rate in Ac (l/ha) is
shown. When the Master switch is off, the application rate shown is zero.
5.0 MPH 100 GPA
Press the Up or Down key to select another display.
APPLI CAT I ON RATE AN D PRESSU RE
In this display the application rate in GPA (l/ha) and the pressure in PSI (bar) is shown. The
pressure is only shown when there is a pressure sensor installed.
20 GPA 30 PSI
Press the Up or Down key to select another display.
FLOW RATE AN D PRESSU RE
In this display the flow rate in GPM (l/min) and the pressure in PSI (bar) is shown. The
pressure is only shown when there is a pressure sensor installed.
35.2 GPA

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 11 of 15
Press the Up or Down key to select another display.
SPRAYED AREA AND SPRAY ED VOLUME
In this display the area and volume counters are shown. The area is measured in acres
(hectares) and the volume is measured in gallons (liters). The counters can be reset to zero by
pressing and holding the Clr key until the values are reset to zero. This can only be done when
there is no spraying activity and the Master switch is OFF.
0.000 Ac 0 Gal
Press the Up or Down key to select another display.
WORKIN G WIDT H
In this display the current working width is shown. The working width depends on the number
of closed sections and whether or not the Master switch is turned on.
45.0 ft <--->
Press the Up or Down key to select another display.

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 12 of 15
Opera t ing Instructions
SPRAYER CH ECK OUT
Before spraying check all connections related to the Sprayer Control assembly. Particular
attention should be given to the speed sensor to be sure the sensor and bolts or magnets are
in-line, and properly secured.
Very important: Whenever you are working around a sprayer or farm chemicals, be
sure to wear protective clothing and eyewear.
Partially fill the sprayer tank with water to flush the system and to make a visual check of the
spray tips to be sure all tips are delivering a good spray pattern.
Follow these steps, in sequence, being sure the Master Switch is in its “OFF” position:
*Be sure the tank shut-off valve is open.
*Start the engine, engage pump, and set the rpm to that which will be used when spraying.
*Switch the computer on by depressing the Pro key on the display panel.
*Turn “ON” the toggle switches for each of the spray booms on your sprayer.
*Now, toggle the Master switch to “on.”
*Adjust the pressure with the +/-switch.
At this point, the sprayer will be activated and spray tip performance can be visually checked.
The +/-switch can be used to raise or lower your spraying pressure. To stop spraying, toggle
the Master switch to “OFF”.
The above steps provide a quick way to check-out your sprayer and computerized monitor
system.
THE SPRAY I NG OPERAT I ON
You have filled the sprayer tank and have thoroughly mixed the chemical(s). Your application
rate has been determined as well as the spray tip you will be using, with the sprayer data
programmed into the computer.
*Switch the computer on by depressing the Pro key on the display panel.
*Toggle the boom switches to their “ON” position, for each of the booms on your sprayer.
*Take note of the “numbered” booms on each side of the sprayer, so that the appropriate
boom can be toggled “OFF” as necessary.
*While spraying with the Master switch “ON”, you can scroll through the different displays
until the information you want is on the display :
♦actual application rate in GPA (l/Ha)
♦vehicle speed in MPH (Km/h)
♦pressure in PSI (bar)
♦actual working width in ft (m)
♦application area covered in Ac (Ha)

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 13 of 15
♦total volume applied in Gal (L)
*Adjust the pressure and target dose rate with the +/-switch.
As you enter the field to the point where you will begin spraying, turn the Master switch to “ON”
position. This will activate the spraying operation. Maintain your usual vehicle speed for
spraying. Use the +/-key to maintain the application rate.
If for any reason you need to stop, turn the MASTER SWITCH to “OFF.”
Automatic Pow er Dow n
The TeeJet 814 Sprayer Monitor has an automatic power down feature. With the Master
switch in the “OFF” position, the Console will automatically shut down after 10 minutes of no
inputs (when in normal monitor mode). This prevents possible battery drainage.
You can also power down the controller by the following key combination: press
simultaneously the Clr, Up and Down keys and the Console will power down immediately (only
with Main valve switch OFF).
WARNING:DO NOT SWITCH OFF THE CONSOLE BY REMOVING THE MAIN CABLE!

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 14 of 15
Appe ndix A: Overview of Monitor Displays
10.0 MPH 25.0GPA
25.0 GPA 36 PSI
CLR
51.3 GPM 45 PSI
5.126 Ac 152 Gal
90.0 ft <
---
>

TeeJet 814 Sprayer Monitor Programming and Operating Manual (V1.00)Page 15 of 15
Appe ndix B: Overview of Progra m m ing Steps
> US u
nits
> 250 puls/300ft
PRO
> 650 puls/l
PRO
> 9.00ft Sect1
-
9
PRO
>4.0 mA 0.0 Bar
PRO
>10.0 Bar 20 mA
PRO
> 2 Way
PRO
PRO
CLR
CLR
CLR
CLR
CLR
CLR
CLR