POWER PIPE™ SYSTEM
Power Pipe™ Stake
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
RELEASE DATE
9-12-17
DRAWING NUMBER
INS-001082
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
Warning High Voltage
NEEDED
FOR
INSTALLATION:
By Others
Hot Surface
Optional
Stability
Flange
Specify Fixture
Separately
12V In 12V Out 120V In 12V Out 120V In 12V or
120V Out
12V or
120V Out
Conduit or UF Cable Conduit or UF Cable
Conduit or UF Cable
GRADEGRADE
Power Pipe™
Junction Box
with ‘B’ Cap
Power Pipe™
Junction Box
with integral 75VA
transformer for
remote fixtures
with ‘C’ Cap
Power Pipe™
Junction Box
with integral 75VA
transformer
with ‘B’ Cap
with integral 75VA
transformer for
remote fixtures
with ‘C’ Cap
with integral 75VA
transformer
with ‘B’ Cap
12V In 12V Out
Power Pipe™
Stake
with ‘B’ Cap
GRADE
12V Out
Power Pipe™
Stake
GRADE
120V In120V In
Power Pipe™
Stake
GRADE
12" or
18"
2" Dia. PVC
Housing
Two 1/2"
PVC Slip
Connectors
PP Stake ‘S’
PP Junction ‘J’
12" or
18"
2" Dia. PVC
Housing
Specify Fixture
Separately
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
IMPORTANT - WEAR GLOVES TO AVOID GETTING FINGERPRINTS ON THIS PRODUCT. MANY TEKA ILLUMINATION PRODUCTS ARE DESIGNED TO NATURALLY PATINA.
OILS FROM YOUR SKIN WILL ACCELERATE THIS PROCESS WHERE TOUCHED AND ARE NEARLY IMPOSSIBLE TO REMOVE. THIS PROCESS OCCURS OVER TIME AND IS
DETERMINED BY THE INSTALLATION ENVIRONMENT.
· Suitable for wet locations
IMPORTANT LISTINGS AND CERTIFICATIONS
Please refer to the low voltage design guide at www.tekaillumination.com/lvguide before installation for proper wire selection.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
5/64” Allen Wrench
Waterproof Wire Connectors
Phillips Screwdriver
POWER PIPE™ SYSTEM
Power Pipe™ Stake
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
1. Make watertight connections from remote
magnetic transformer to fixture leads using
waterproof wire connectors. (By Others)
STAKE WITH “B” CAP:
2. Attach ground from branch circuit to screw in
transformer T-housing. Place transformer and
connectors into T-housing.
3. Attach C cap and transformer T-housing
to Power Pipe™ with (3) #8-32 round head
Phillips stainless steel screws at base of
housing to secure to Power Pipe™ with Phillips
screwdriver.
WIRING DIAGRAM
120V 12V
Lamp
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
Junction Box/Stake w Transformer and B Cap
120V 12V
Fixture
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
Junction Box/Stake w Transformer and C Cap
1. Make watertight connections from primary
branch circuit to primary side of transformer
using waterproof wire connectors. (By Others).
Attach secondary leads from transformer to
fixture leads using waterproof wire connectors.
(By Others). See wiring diagram.
STAKE WITH INTEGRAL TRANSFORMER T-HOUSING WITH “C” CAP:
RELEASE DATE
9-12-17
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
DRAWING NUMBER
INS-001082
2. Route the necessary UL approved under
ground branch circuit or low voltage wiring
to Power Pipe™ necessary for appropriate
installation. Leave enough length to make
connections to lamp leads.
3. Back fill hole with soil and/or prep for
concrete.
4. Pull branch circuit or low voltage wiring
necessary for appropiate installation (By
Others).
1. Excavate trench according to designed lighting
plan. Dig hole a minimum of 24” deep and 10” wide
to accommodate Power Pipe™ at desired fixture
locations.
INSTALLATION OF POWER PIPE™ STAKE
Finished grade
Pea gravel or sand
Finished grade
Finished grade
Stability Flange Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
Finished grade
Pea gravel or sand
Finished grade
Finished grade
Stability Flange Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
Finished grade
Pea gravel or sand
Finished grade
Finished grade
Stability Flange Pea gravel or sand
Finished grade
Pea gravel
or sand
Above Ground
Installation
Pea gravel
or sand
Concrete
Pea gravel
or sand
Pea gravel
or sand
Pea gravel
or sand
Concrete
Below Ground
Installation
Pea gravel
or sand
2. Attach B cap to Power Pipe™ with (3) #8-32
round head Phillips stainless steel screws at
base to secure to Power Pipe™ with Phillips
screwdriver.
120V 12V
Fixture
COM
Remote
Transformer
COM
120V 12V
Fixture
COM
GROUND
WIRING DIAGRAM
Integral
Transformer
COM
GROUND IN HOUSING
WIRING DIAGRAM
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
POWER PIPE™ SYSTEM
Power Pipe™ Stake
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
WIRING DIAGRAM 4. Place transformer and connectors into
T-housing. Attach B cap to T-housing with
(3) #8-32 stainless steel set screws using 5/64”
Allen wrench.
3. Make watertight connections from primary
branch circuit to primary side of transformer
using waterproof wire connectors. (By Others).
Attach secondary leads from transformer to
fixture leads using waterproof wire connectors.
(By Others). See wiring diagram.
STAKE WITH INTEGRAL TRANSFORMER AND “B” CAP:
RELEASE DATE
9-12-17
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
DRAWING NUMBER
INS-001082
1. Pull primary branch circuit through
transformer T-housing. Attach ground
from branch circuit to screw in transformer
T-housing.
WIRING DIAGRAM
120V 12V
Lamp
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
Junction Box/Stake w Transformer and B Cap
120V 12V
Fixture
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
Junction Box/Stake w Transformer and C Cap
2. Attach transformer T-housing to Power Pipe™
with (3) #8-32 round head Phillips stainless
steel screws at base of housing to secure to
Power Pipe™ with Phillips screwdriver.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
POWER PIPE™ SYSTEM
Power Pipe™ Junction Box
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
RELEASE DATE
9-12-17
DRAWING NUMBER
INS-001082
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY
DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
Warning High Voltage
5/64” Allen Wrench
Waterproof Wire Connectors
Phillips Screwdriver
NEEDED
FOR
INSTALLATION:
By Others
Hot Surface
Specify Fixture
Separately
12V In 12V Out 120V In 12V Out 120V In 12V or
120V Out
12V or
120V Out
Conduit or UF Cable Conduit or UF Cable
Conduit or UF Cable
GRADEGRADE
Power Pipe™
Junction Box
with ‘B’ Cap
Power Pipe™
Junction Box
with integral 75VA
transformer for
remote fixtures
with ‘C’ Cap
Power Pipe™
Junction Box
with integral 75VA
transformer
with ‘B’ Cap
with integral 75VA
transformer for
remote fixtures
with ‘C’ Cap
with integral 75VA
transformer
with ‘B’ Cap
12V In 12V Out
Power Pipe™
Stake
with ‘B’ Cap
GRADE
12V Out
Power Pipe™
Stake
GRADE
120V In120V In
Power Pipe™
Stake
GRADE
12" or
18"
2" Dia. PVC
Housing
Two 1/2"
PVC Slip
Connectors
PP Stake ‘S’
PP Junction ‘J’
12" or
18"
2" Dia. PVC
Housing
Specify Fixture
Separately
Optional
Stability
Flange
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
IMPORTANT - WEAR GLOVES TO AVOID GETTING FINGERPRINTS ON THIS PRODUCT. MANY TEKA ILLUMINATION PRODUCTS ARE DESIGNED TO NATURALLY PATINA.
OILS FROM YOUR SKIN WILL ACCELERATE THIS PROCESS WHERE TOUCHED AND ARE NEARLY IMPOSSIBLE TO REMOVE. THIS PROCESS OCCURS OVER TIME AND IS
DETERMINED BY THE INSTALLATION ENVIRONMENT.
· Suitable for wet locations
IMPORTANT LISTINGS AND CERTIFICATIONS
Please refer to the low voltage design guide at www.tekaillumination.com/lvguide before installation for proper wire selection.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
• Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all Local and
Provincial Codes.
• Follow product label information and instructions.
• Qualified Personnel with appropriate personal protective
equipment must perform all servicing of this product.
• Before wiring to power supply and during servicing, turn off and
lock out power at fuse or circuit breaker before service.
• The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an
unsafe condition. The use of damaged components may cause an
unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY
AND INSTALLATION INSTRUCTIONS
• Do not block light emanating from product in whole or part, as
this may cause an unsafe condition.
• Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
• Entire fixture may become extremely hot. Do not touch hot
lens or fixture body.
• Replace LED assembly only with correct wattage and type of
power supply appropriate for LED assembly.
• All gaskets, o-rings and sealing surfaces must be kept clean
during installation and service; failure to do this may cause an
unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY TO
PERSONS IMPORTANT SAFETY
INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time. Use
a soft cloth or gloves. Oil from skin may cause damage.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS
2. Connect conduit to the 1/2” conduit couplers
attached to the bottom of the PowerPipe™.
Place PowerPipe™ in hole.
3. Back fill hole with soil and/or prep for
concrete.
4. Pull branch circuit or low voltage wiring
necessary for appropriate installation (By
Others).
1. Excavate trench according to designed lighting
plan. Dig hole a minimum of 24” deep and 10” wide
to accommodate PowerPipe™ at desired fixture
locations.
INSTALLATION OF POWER PIPE™ JUNCTION BOX
Finished grade
Pea gravel or sand
Concrete or Dirt
Finished grade
Finished grade
Pea gravel or sand
Concrete or Dirt
Finished grade
Finished grade
Pea gravel or sand
Concrete or Dirt
Finished grade
POWER PIPE™ SYSTEM
Power Pipe™ Junction Box
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASE DATE
9-12-17
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
DRAWING NUMBER
INS-001082
1. Make watertight connections from remote
magnetic transformer to fixture leads using
waterproof wire connectors. (By Others)
JUNCTION BOX WITH “B” CAP:
2. Attach ground from branch circuit to screw in
transformer T-housing. Place transformer and
connectors into T-housing.
3. Attach C cap and transformer T-housing
to Power Pipe™ with (3) #8-32 round head
Phillips stainless steel screws at base of
housing to secure to Power Pipe™ with Phillips
screwdriver.
WIRING DIAGRAM
120V 12V
Lamp
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
Junction Box/Stake w Transformer and B Cap
120V 12V
Fixture
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
Junction Box/Stake w Transformer and C Cap
1. Make watertight connections from primary
branch circuit to primary side of transformer
using waterproof wire connectors. (By Others).
Attach secondary leads from transformer to
fixture leads using waterproof wire connectors.
(By Others). See wiring diagram.
JUNCTION BOX WITH INTEGRAL TRANSFORMER T-HOUSING WITH “C” CAP:
2. Attach B cap to Power Pipe™ with (3) #8-32
round head Phillips stainless steel screws at
base to secure to Power Pipe™ with Phillips
screwdriver.
120V 12V
Fixture
COM
Remote
Transformer
COM
120V 12V
Fixture
COM
GROUND
WIRING DIAGRAM
Integral
Transformer
COM
GROUND IN HOUSING
WIRING DIAGRAM
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
POWER PIPE™ SYSTEM
Power Pipe™ Junction Box
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASE DATE
9-12-17
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING
IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.
DRAWING NUMBER
INS-001082
WIRING DIAGRAM 4. Place transformer and connectors into
T-housing. Attach B cap to T-housing with
(3) #8-32 stainless steel set screws using 5/64”
Allen wrench.
3. Make watertight connection from primary
branch circuit to primary side of transformer
using waterproof wire connectors. (By Others).
Attach secondary leads from transformer to
fixture leads using waterproof wire connectors.
(By Others). See wiring diagram.
JUNCTION BOX WITH INTEGRAL TRANSFORMER AND “B” CAP:
1. Pull primary branch circuit through
transformer T-housing. Attach ground
from branch circuit to screw in transformer
T-housing.
WIRING DIAGRAM
120V 12V
Lamp
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
Junction Box/Stake w Transformer and B Cap
120V 12V
Fixture
COM
GROUND
Transformer
COM
GROUND IN T-HOUSING
WIRING DIAGRAM
Junction Box/Stake w Transformer and C Cap
2. Attach transformer T-housing to Power Pipe™
with (3) #8-32 round head Phillips stainless
steel screws at base of housing to secure to
Power Pipe™ with Phillips screwdriver.
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]

Popular Transformer manuals by other brands

Chamberlain 041C0168 manual

Chamberlain

Chamberlain 041C0168 manual

Hypertherm HyPerformance Plasma HPR260 Field Service Bulletin

Hypertherm

Hypertherm HyPerformance Plasma HPR260 Field Service Bulletin

Audioplex STEREO MATCHIT 200 installation manual

Audioplex

Audioplex STEREO MATCHIT 200 installation manual

mdexx TAM Series operating instructions

mdexx

mdexx TAM Series operating instructions

LEGRAND HPM RGL11 instruction manual

LEGRAND

LEGRAND HPM RGL11 instruction manual

Arteche CA user manual

Arteche

Arteche CA user manual

Art DTI Specifications

Art

Art DTI Specifications

Farfisa PRS 210 quick start guide

Farfisa

Farfisa PRS 210 quick start guide

Monacor Security TVI-100 manual

Monacor

Monacor Security TVI-100 manual

Inter-m OT-4960 operating manual

Inter-m

Inter-m OT-4960 operating manual

ZELISKO GWR3 MAINTENANCE AND MOUNTING INSTRUCTION

ZELISKO

ZELISKO GWR3 MAINTENANCE AND MOUNTING INSTRUCTION

Art T8 Specifications

Art

Art T8 Specifications

Sealey WST10000 manual

Sealey

Sealey WST10000 manual

MicroRidge WedgeLink SP user guide

MicroRidge

MicroRidge WedgeLink SP user guide

LUMIEN TR-250 installation guide

LUMIEN

LUMIEN TR-250 installation guide

3B SCIENTIFIC 1001009 instruction sheet

3B SCIENTIFIC

3B SCIENTIFIC 1001009 instruction sheet

Heatit Controls 45 126 48 quick guide

Heatit Controls

Heatit Controls 45 126 48 quick guide

Omron KM-NCT-E Series instruction manual

Omron

Omron KM-NCT-E Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.