VIEWING THE CURRENT TEMPERATURE (508 ONLY)
The View menu allows you to view the current temperature(s) being sensed by the thermostat and
its auxiliary sensor To view the various temperatures, begin by selecting the View menu using the
Menu button Next use the Item button to view the available temperatures
Room: This is the current air temperature of the room that is being controlled At least one air
sensor must be active for this temperature to be displayed
Outdoor: This is the current outdoor air temperature This item is only available if the auxiliary sensor has been set to sense
the outdoor air temperature
Slab: This is the current slab temperature This item is only available if the auxiliary sensor has been set to sense the
slab temperature
SETTING THE TEMPERATURE(S)
Use the following procedure to set the desired air and/or slab temperatures
Note: Slab temperatures are only a ailable when a slab sensor is used.
Step One: Press and release the Menu button until the Adjust Menu is reached
Step Two: Press and release the Item button until the desired item is displayed
Step Three: Use the
or button to set the desired temperature
AWAY OVERRIDE (508 ONLY)
An Away override is a quick override that does not change your existing temperature setting(s)
This is to be used during long periods of absence When the Away override is selected, the heating
temperature is automatically set to 62°F (16 5°C) If a slab sensor is being used with the thermostat,
the minimum slab temperature is also ignored This operation continues as long as the Away
override is selected
To select the Away o erride, use the following procedure.
Step One: Press and release the Menu button until the Schedule (SCHD) Menu is displayed
Step Two: Use the
or button to select the Away override
CANCELING THE AWAY OVERRIDE (508 ONLY)
To cancel the Away o erride, use the following procedure.
Step One: Press and release the Menu button until the Schedule (SCHD) Menu is displayed
Step Two: Use the
or button to select the None setting
UNITS OF DISPLAY
To select between Fahrenheit and Celsius, use the following procedure.
Step One: Press and release the Menu button until the Adjust Menu is reached
Step Two: Press and release the Item button until the current temperature unit begins to flash
Step Three: Use the
or button to select between Fahrenheit and Celsius
SETTING THE MODE OF OPERATION
Use the following procedure to select the mode of operation
Step One: Press and release the Menu button until the Adjust Menu is reached
Step Two: Use the
or button to select between the Off and Heat setting
Off:
In the Off mode, the thermostat does not operate the heating device
Heat: In the Heat mode, the thermostat operates to maintain the room at the required
heating temperature