Tektronix VX1411 User manual

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Tektronix VX1411 at our website: Click HERE

Instruction Manual
VX1411
VXIbus Mainframe
070-9602-00
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to the Safety Summary prior to
performing service.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Copyright Tektronix, Inc. All rights reserved.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price change privileges reserved.
Printed in the U.S.A.
Tektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

WARRANTY
Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship
for a period of three (3) years from the date of shipment. If a product proves defective during this warranty period,
Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a
replacement in exchange for the defective product.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the
warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for
packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid.
Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the
Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any
other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate
maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting
from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair
damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction
caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated with other
products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO
REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO
THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE
LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE
OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH
DAMAGES.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

VX1411 MainFrame Instruction Manual i
Table of Contents
General Safety Summary vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Safety Summary ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface xi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Getting Started
Getting Started 1–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Description 1–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard Accessories 1–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optional Accessories 1–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selecting the Correct Power Cord and Fuse 1–5. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation 1–6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration 1–17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Functional Check 1–22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Basics
Operating Basics 2–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Speed Control 2–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference
Backplane Connectors 3–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
Specifications 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance Verification
Equipment Required 5–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC Voltage Regulation 5–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance
Service Strategy 6–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparation 6–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspection and Cleaning 6–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interior Cleaning 6–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Exterior Cleaning 6–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cleaning the Fan Filter 6–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removal and Replacement 6–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tools Required 6–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Procedure 1: Removing the Fan Assembly 6–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Procedure 2: Removing the Fan Control Board 6–7. . . . . . . . . . . . . . . . . . . . . . . . . .
Procedure 3: Removing the Power Supply 6–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Procedure 4: Removing the Card Guides 6–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Procedure 5: Replacing the Top and Bottom Nut Rails 6–11. . . . . . . . . . . . . . . . . . . .
Procedure 6: Removing the Backplane 6–12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents
ii VX1411 MainFrame Instruction Manual
Troubleshooting Procedures 6–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment List 6–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostic Information 6–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fuses 6–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fault Isolation 6–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repackaging Instructions 6–15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Theory of Operation 6–15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replaceable Parts
Parts Ordering Information 7–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VX1411 Mainframe Common Replaceable Parts 7–2. . . . . . . . . . . . . . . . . . . . . . . .
Using the Replaceable Parts List 7–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendicies
Appendix A: Power Budget Worksheet A–1. . . . . . . . . . . . . . . . . . . . . . . . .
Glossary
Index
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents
VX1411 MainFrame Instruction Manual iii
List of Figures
Figure 1–1: Installing the Option 1U 1.75-inch deep cable tray 1–7. . . . .
Figure 1–2: Installing the Option 1U 2.5-inch deep cable tray 1–8. . . . . .
Figure 1–3: Installing the Option 1U 4.25-inch deep cable tray 1–9. . . . .
Figure 1–4: Installing the rackmount kit hardware 1–11. . . . . . . . . . . . . . .
Figure 1–5:Assembling the slide-out track assemblies 1–12. . . . . . . . . . . .
Figure 1–6: Vertical clearance for rack installation
(standard mainframe) 1–13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1–7: Installing the slide-out track assemblies
in the rack (top view) 1–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1–8: Installing the rackmount door (Option 2R) 1–16. . . . . . . . . . .
Figure 1–9: Installing the empty slot panel fillers 1–18. . . . . . . . . . . . . . . .
Figure 1–10: Locations of safety and chassis ground connections on left rear
of the mainframe 1–19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1–11: Installing the backplane EMI DIN Shields 1–20. . . . . . . . . . .
Figure 1–12: Installing the EMI intermodule shield and front panel EMI
fillers 1–21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–1: Front view of the VX1411 Mainframe 2–1. . . . . . . . . . . . . . .
Figure 2–2: Power output fan versus temperature for
the 2 fan speeds 2–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–3: Rear View of the VX1411 Mainframe 2–3. . . . . . . . . . . . . . . .
Figure 4–1: Power output versus temperature for the 2 fan speeds 4–4. .
Figure 4–2: Mainframe cooling curve 4–5. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 4–3: Front view and side view of VX1411 Mainframe 4–10. . . . . . .
Figure 4–4: Front view and side view of VX1411 Mainframe with Option 1U
and rackmount option 4–11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–1: Removing the Fan Filter 6–3. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–2: Location of Fan Assembly Screws on the
Rear of the Mainframe 6–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–3: Removing the Fan Assembly 6–6. . . . . . . . . . . . . . . . . . . . . . .
Figure 6–4: Removing the Fans 6–6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–5: Removing the fan control board 6–7. . . . . . . . . . . . . . . . . . . .
Figure 6–6: Removing the Power Supply Interface Board 6–8. . . . . . . . .
Figure 6–7: Removing the Top and Bottom Card Guides 6–10. . . . . . . . . .
Figure 6–8: Replacing the Top and Bottom Nut Rails 6–11. . . . . . . . . . . . .
Figure 6–9: Removing the Backplane 6–13. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 6–10: Mainframe block diagram 6–17. . . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents
iv VX1411 MainFrame Instruction Manual
Figure 7–1: Cabinet and Chassis Assembly 7–7. . . . . . . . . . . . . . . . . . . . .
Figure 7–2: Circuit Boards and Chassis Parts 7–9. . . . . . . . . . . . . . . . . . .
Figure 7–3: Power Supply and Fan Assembly 7–11. . . . . . . . . . . . . . . . . . .
Figure 7–4: 1R Rackmount Assembly 7–13. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 7–5: 2R Rackmount and Door Assembly 7–15. . . . . . . . . . . . . . . . .
Figure 7–6: Option 1U Cable Tray 7–17. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents
VX1411 MainFrame Instruction Manual v
List of Tables
Table 1–1: VX1411 Mainframe options and upgrade kits 1–3. . . . . . . . .
Table 1–2: Power cord identification 1–4. . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1–3: Line fuse application 1–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1–4: Power supply voltages P1 and P2 of the extender card 1–22. .
Table 3–1: P1 Connector pinouts 3–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3–2: P2 Connector pinouts for slots 1 – 12 3–2. . . . . . . . . . . . . . . .
Table 3–3: P2 Connector pinouts for slot 0 3–3. . . . . . . . . . . . . . . . . . . . .
Table 4–1: AC power source 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4–2: Secondary power 4–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4–3: Cooling 4–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4–4: Environmental 4–6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4–5: Certifications and compliances 4–7. . . . . . . . . . . . . . . . . . . . . .
Table 4–6: Backplane 4–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4–7: Mechanical 4–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4–8: VXI and VXIplug&play 4–11. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 6–1: Fuses 6–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 7–1: VX1411 Mainframe Common Replaceable Parts 7–2. . . . . . .
Table 7–2: Parts list column descriptions 7–3. . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

VX1411 MainFrame Instruction Manual vii
General Safety Summary
Review the following safety precautions to avoid injury and prevent damage to
this product or any products connected to it.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read
the General Safety Summary in other system manuals for warnings and cautions
related to operating the system.
To avoid potential hazards use this product only as specified.
Use Proper Power Cord. To avoid fire hazard, use only the power cord specified
for this product.
Avoid Electric Overload. To avoid electric shock or fire hazard, do not apply a
voltage to a terminal that is outside the range specified for that terminal.
Avoid Overvoltage. To avoid electric shock or fire hazard, do not apply potential
to any terminal, including the common terminal, that varies from ground by
more than the maximum rating for that terminal.
Avoid Electric Shock. To avoid injury or loss of life, do not connect or disconnect
probes or test leads while they are connected to a voltage source.
Ground the Product. This product is grounded through the grounding conductor
of the power cord. To avoid electric shock, the grounding conductor must be
connected to earth ground. Before making connections to the input or output
terminals of the product, ensure that the product is properly grounded.
Do Not Operate Without Covers. To avoid electric shock or fire hazard, do not
operate this product with covers or panels removed.
Use Proper Fuse. To avoid fire hazard, use only the fuse type and rating specified
for this product.
Do Not Operate in Wet/DampConditions. To avoid electric shock, do not operate
this product in wet or damp conditions.
Do Not Operate in an Explosive Atmosphere. To avoid injury or fire hazard, do not
operate this product in an explosive atmosphere.
Use Proper Power Source. Do not operate this product from a power source that
applies more than the voltage specified.
Provide Proper Ventilation. To prevent product overheating, provide proper
ventilation.
Injury Precautions
Product Damage
Precautions
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

General Safety Summary
viii VX1411 MainFrame Instruction Manual
Do Not Operate With Suspected Failures. If you suspect there is damage to this
product, have it inspected by qualified service personnel.
Terms in this Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result
in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the
marking.
WARNING indicates an injury hazard not immediately accessible as you read the
marking.
CAUTION indicates a hazard to property including the product.
Symbols on the Product. The following symbols may appear on the product:
ProtectiveGround
(Earth)Terminal ATTENTION
Refer to Manual Double
Insulated
DANGER
High Voltage
Symbols and Terms
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

VX1411 MainFrame Instruction Manual ix
Service Safety Summary
Only qualified personnel should perform service procedures. Read this Service
Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this
product unless another person capable of rendering first aid and resuscitation is
present.
Disconnect Power. To avoid electric shock, disconnect the main power by means
of the power cord or, if provided, the power switch.
Use Care When Servicing With Power On. Dangerous voltages or currents may
exist in this product. Disconnect power, remove battery (if applicable), and
disconnect test leads before removing protective panels, soldering, or replacing
components.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

VX1411 MainFrame Instruction Manual xi
Preface
The VX1411 Mainframe Instruction Manual provides information on using the
mainframe. The manual includes the following chapters:
HGetting Started provides a brief description of the VX1411 Mainframe, a list
of accessories that accompany the mainframe, installation and configuration
procedures, and a functional check procedure.
HOperating Basics provides a functional overview of the mainframe and
includes illustrations of the main components.
HSpecifications lists all of the warranted characteristics, nominal traits, and
typical characteristics of the mainframe.
HPerformance Verification includes the performance verification procedures
used to verify the advertised specifications of the mainframe.
HMaintenance is intended for qualified service personnel who need to service
the mainframe. Module-level removal and replacement procedures and
troubleshooting procedures are included in this chapter.
HReplaceable Parts includes a list of replaceable mechanical and electrical
parts for the mainframe to be used with the maintenance chapter. It also
includes the exploded view diagrams of the mainframe and options.
HAppendices include a power budget.
HGlossary.
HIndex.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

VX1411 MainFrame Instruction Manual 1–1
Getting Started
This chapter provides an overview of the VX1411 Mainframe. It includes
installation and configuration information on user installed options.
Product Description
The VX1411 Mainframe is a 13-slot, C-size, VXIbus Mainframe. It fully
complies with the VXIbus Specification 1.4 requirements and is VXIplug&play
compatible. The mainframe has the following features:
HAdequate available power for the majority of applications
HIntelligent cooling for installed modules
HHigh quality auto-configuration backplane
HOptional adjustable rackmounts and cable tray
These features are explained in more detail in the following paragraphs.
The VX1411 Mainframe provides all VXIbus voltages at levels necessary for
most ATE applications. The power supply has a volt-ampere capacity of 904 VA,
but only 500 watts is usable by VXI instrument modules at any one time (see
Appendix A: Power Budget Worksheet). The mainframe accommodates
exclusively digital applications, exclusively analog applications, or combina-
tions of both.
The power supply plugs directly into the rear of the mainframe and has no cables
to disconnect. Because of this, the power supply can easily be replaced in less
than three minutes, keeping downtime to a minimum. The power supply
automatically sets the ranges for the appropriate input voltage and frequency; no
mechanical switch is required to select the correct line voltage.
The VX1411 Mainframe provides optimal cooling for all installed modules. The
mainframe is equipped with two efficient 2 speed fans. The fan speed can easily
be manually switched from a low noise, low speed to high speed for maximum
cooling.
Air is exhausted at the sides of the mainframe allowing you to stack the
mainframe with other rackmount equipment. Additional equipment placed on or
positioned above the product will not restrict airflow nor will that equipment be
directly affected by exhaust air.
Power Supply
Cooling
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Getting Started
1–2 VX1411 MainFrame Instruction Manual
CAUTION. Make sure the ambient air temperature inside the rackmount enclosure
remains below 55C.
Cooling is not wasted on empty slots. IntelliGuides automatically direct air to
only those slots containing modules; empty slots are shut off. The mainframe
directs airflow across each installed module from the bottom to the top of each
slot. Baffles balance the airflow from the front to back and across occupied slots
in the mainframe.
You can easily remove the air filter from the rear of the mainframe within a
matter of seconds. The fans can be easily replaced without disassembling the
entire mainframe.
The VX1411 Mainframe has an auto-configuration, solid-state backplane that
uses electronic jumpers for the IACK and BUS GRANT signal lines. There are
no jumpers to move or install on the backplane. This results in a high quality
backplane that is ideal for ATE systems that must be reconfigured frequently.
Full differential distribution of the CLK10 signals provide a clean timing source
for your VXIbus instruments.
You can order the VX1411 Mainframe with user-installed rackmounts and cable
tray. The cable tray provides a means to conveniently route cables from the front
of the modules to the rear of the mainframe. Option 1U includes a 1.75-inch
connector plate. You can install Option 1U to provide a 1.75-inch, 2.5-inch, or
4.25-inch deep cable tray.
The rackmount adapters let you recess the mainframe from the front panel
mounting surface at specified depths from 0.735 inches to 5.735 inches in
0.5-inch increments. Similarly, you can configure the mainframe to extend out of
the front of the rack at specified depths (0.57 inches to 5.57 inches in 0.5-inch
increments).
You can install the rackmount kits along with the cable tray to provide vertical
cable access to easily route cables to instruments above or below the mainframe
while keeping lead lengths as short as possible.
You can also install an optional Lexan door with the rackmount kit.
NOTE. If you choose to extend the mainframe out of the front of the rack, the
mainframe cannot accept a door.
Instructions for installing the cable tray begin on page 1–6 and instructions for
the rackmounts begin on page 1–10.
Backplane
Optional Rackmounts and
Cable Tray
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Getting Started
VX1411 MainFrame Instruction Manual 1–3
Table 1–1 lists the VX1411 Mainframe options and upgrade kits that you can
purchase and install separately. Contact your local Tektronix representative for
information on the upgrade kits.
Table 1–1: VX1411 Mainframe options and upgrade kits
Description Option Part Number
Rackmount Kit with Rack Slides 1R 020-2117-XX
Rackmount Kit with Rack Slides and Lexan Door 2R 020-2118-XX
Cable Tray Kit 1U 020-2119-XX
Options and Upgrade Kits
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Getting Started
1–4 VX1411 MainFrame Instruction Manual
Standard Accessories
The VX1411 Mainframe comes with the following standard accessories:
HVX1411 Mainframe Instruction Manual
HOne Power cord (voltage range and plug type varies according to country,
see Table 1–2)
H5 x 20 mm line fuse, 4 A, 250 V
H5 x 20 mm line fuse holder
Table 1–2: Power cord identification
Plugconfiguration Normal usage Option number
NorthAmerica
250V/13APlug
NEMA5-15P
Standard
Europe
230 V A1
UnitedKingdom
230 V A2
Australia
230 V A3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Getting Started
VX1411 MainFrame Instruction Manual 1–5
Table 1–2: Power cord identification (Cont.)
Plug configuration Option numberNormal usage
NorthAmerica
230 V A4
Switzerland
230 V A5
Optional Accessories
The VX1411 Mainframe has the following optional accessories:
HSingle-wide front panel fillers (Tektronix part number 334-4170-00)
HDouble-wide front panel fillers (Tektronix part number 334-4169-00)
HSingle-wide EMI front panel fillers (Tektronix part number 333-4092-00)
HDouble-wide EMI front panel fillers (Tektronix part number 333-4092-01)
HEMI intermodule shields (Tektronix part number 337-4041-00)
HBackplane EMI DIN shields (Tektronix part number 020-2144-00)
Selecting the Correct Power Cord and Fuse
The VX1411 Mainframe comes standard with a power cord and two fuses.
Before installing the mainframe, you must determine the correct fuse for your
application. Use the following information to determine the appropriate line fuse
for the VX1411 Mainframe:
Table 1–3: Line fuse application
Line voltage fuse
90 – 250V 10A fast, 0.25 x 1.25 in
207 – 250 V 4A time delay, 5 x 20mm, (use 5 x20mm fuseholder cap)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Getting Started
1–6 VX1411 MainFrame Instruction Manual
Installation
This section describes the procedures to install your mainframe. It includes
procedures for installing the mainframe with the rackmount or cable tray options.
This section does not include specific procedures for installing modules in the
mainframe. Refer to your module documentation for information regarding the
module installation instructions.
The VX1411 Mainframe is designed to operate on a bench or in a rackmount
environment. For proper cooling, allow at least two inches (5.1 cm) of clearance
on the rear and sides of the mainframe. Determine how you will use your
VX1411 Mainframe and follow the appropriate installation instructions. If you
ordered your mainframe with the cable tray option and one of the rackmount
options, install the cable tray before installing the rackmount.
WARNING. Use care when lifting or moving the mainframe to avoid personal
injury while performing the installation procedures.
The VX1411 Mainframe comes a with 0.75-inch cable access area on the bottom
of the mainframe (1-inch with the feet installed for bench-top operation). You
can order the mainframe with an optional cable tray and install the cable tray
following the procedures in this section. The option comes with a butch plate to
mount cable connectors at the rear of the cable tray.
The cable tray option can be installed three different ways as shown in the
following illustrations. In each example, place the mainframe upside-down or on
one of the sides on a clean working surface and follow the instructions in the
illustrations. To install the cable tray you need a T-15 and a T-20 Torx Driver.
Figure 1–1 on page 1–7 shows how to install Option 1U to provide a cable tray
depth of 1.75 inches.
Figure 1–2 on page 1–8 shows how to install Option 1U to provide a cable tray
depth of 2.5 inches.
Figure 1–3 on page 1–9 shows how to install Option 1U to provide a cable tray
depth of 4.25 inches.
You can modify the butch plate to accept cable connectors at the rear of the
mainframe. Specific instructions for modifying the butch plate are not given
since the locations, types, and size of connectors vary with each application.
Site Considerations
Cable Tray Installation
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Getting Started
VX1411 MainFrame Instruction Manual 1–7
Loosen 4
outside screws.
1Remove 4 feet.
3Remove 2 rails.
Install feet (optional)
Install butch plate.
(optional)
Install cable tray and
tighten 4 screws.
Remove 4
inside screws.
4
2
6
5
Figure 1–1: Installing the Option 1U as a 1.75-inch deep cable tray