Teledyne SyriXus 65x Operating instructions

SyriXus Syringe Pumps Installation and Operation Guide
Syringe Pumps
Installation and
Operation Guide
Part #69-1263-358
Copyright © 2022. All rights reserved, Teledyne ISCO
Rev. - April, 2022
Use and Disclosure of Data: Information contained herein is classified as EAR99 under the U.S. Export
Administration Regulations. Export, reexport or diversion contrary to U.S. law is prohibited.

EAR99 Technology Subject to Restrictions Contained on the Cover Page
This instruction manual is designed to help you gain a thorough understanding of the operation of the
equipment. Teledyne ISCO recommends that you read this manual completely before placing the
equipment in service.
Although Teledyne ISCO designs reliability into all equipment, there is always the possibility of a
malfunction. This manual may help in diagnosing and repairing the malfunction.
If a problem persists, call or e-mail Teledyne ISCO technical support for assistance. Refer to Section
9.3 "Customer Service Department". Simple difficulties can often be diagnosed over the phone. For
faster service, please have your serial number ready.
If it is necessary to return the equipment to the factory for service, please follow the shipping instruc-
tions provided by technical support, including the use of the Return Material Authorization (RMA)
specified. Be sure to include a note describing the malfunction. This will aid in the prompt repair and
return of the equipment.
Teledyne ISCO welcomes suggestions that would improve the information presented in this manual
or enhance the operation of the equipment itself.
Teledyne ISCO is continually improving its products and reserves the right to change product specifi-
cations, replacement parts, schematics, and instructions without notice.
Contact Information
Customer Service
Phone (USA, Canada, Mexico): (800) 228-4373
P h o n e ( O u t s i d e N o r t h
America):
(402) 464-0231
Fax: (402) 465-3022
Email: [email protected]
Technical Support
Phone (Toll Free): (800) 775-2965 Syringe Pumps & Liquid Chromatography
Email: [email protected]
R e t u rn E q u ip m e n t a n d
Other Correspondence
Mail: 4700 Superior Street, Lincoln, NE 68504-1398
Warranty and Operation Manuals can be found on our website at:
www.teledyneisco.com

Warnings and Cautions
i
EAR99 Technology Subject to Restrictions Contained on the Cover Page
Preface
Warnings and Cautions
Symboles de Sécurité
Warnungen und Vorsichtshinweise
The lightning flash and arrowhead within the triangle is a warning sign alerting you to
“dangerous voltage” inside the product.
The exclamation point within the triangle is a warning sign alerting you to important
instructions in this manual.
Ce symbole signale la présence d’un danger d’électrocution.
Ce symbole signale l’existence d’instructions importantes relatives au produit dans ce
manuel.
Der gepfeilte Blitz im Dreieck ist ein Warnzeichen, das Sie vor „gefährlichen Span-
nungen“im Inneren des Produkts warnt.

Advertencias y Precauciones
ii
EAR99 Technology Subject to Restrictions Contained on the Cover Page
Advertencias y Precauciones
General Product Warnings and Cautions
Das Ausrufezeichen in Dreieck ist ein Warnzeichen, das Sie darauf aufmerksam macht,
daß wichtige Anleitungen zu diesem Handbuch gehören.
Esta señal alerta sobre la presencia de alto voltaje en el interior del producto.
Esta señal le advierte sobre la importancia de las instrucciones del manual que acom-
pañan a este producto.
“To prevent damaging the instrument or injuring yourself, it is
absolutely necessary that you understand everything in English,
above all, technical terms, before operating the instrument. Oth-
erwise, it is necessary for you to receive complete instruction from
someone qualified who understands both the instrument and
English very well.”
“Um eine Beschädigung des Gerätes oder eine Gefährdung des
Anwenders zu vermeiden ist es notwendig, daß dieser vollstandig
die englische Sprache und die technischen Bezeichnungen
beherrscht. Oder der Anwender muß von einer Person eingeübt
werden, die bereits vorher dieses Gerät bedienst hat.”
“Pour empêcher dommage à l’instrument ou blesser vous-même, il
faut absolument que vous compreniez tout en anglais, surtout les
termes techniques, avant d’actionner l’instrument. Autrement, il
faut que vous receviez l’instruction parfaite d’une personne très
compétente qui comprend bien les deux l’instrument et anglais.”
“Para prevenir cualquier daño en el instrumento o en el operador,
es necesario que el usuario comprenda perfectamente el lenguaje
inglés y las términos técnicos intrínsecos, o bien ser formado por
una persona que haya trabajado ya previamente con este instru-
mento.”

General Product Warnings and Cautions
iii
EAR99 Technology Subject to Restrictions Contained on the Cover Page
“For a forhindre skade på instrumentet eller operatøren er det nød-
vendig at brukeren har full forståelse for det engelske sprak og
tekniske uttrykk Ellers må brukeren få opplæring av en person,
som kan engelsk, for instrumentet tas i bruk.”
“För att förhindra skade på instrumentet eller operatören, år det
nötvändigt att användaren har fullständiga kunskaper i det
engelska språket och dess tekniska termer, eller utbildas av en
person, som tidigare brukat instrumentet.”
“For at undgå skade på produktet eller på brugeren er det nød-
vendigt at brugeren til fulde forstår det engelske sprog for at forstå
den tekniske formulering i den engelske manual. I modsat fald skal
brugeren modtage træning, inden apparatet tages I drift.”
Laitteelle tai käyttäjälle aiheutuvien vahinkojen välttämiseksi on
tärkeää, että käyttäjä hallitsee englannin kielen ja englantilaiset
tekniset termit tai on saanut käyttöopastuksen englantia osaavalta
henkilöltä.
“Per evitare danni allo struménto od incidenti all’operatore, é nec-
essario che l’utilizzatore abbia una completa conoscensza della
lingua inglese oppure che venga istruita da una persona che abbia
utilizzato precedentemente questo strumento.”
“Para impedir qualquer dano no aparelho ou ferimentos parao
operador, é necessario que o utilizador tenha um conhecimento
completo da lingua inglesa e dos respectivos termos técnicos, ou
seja, treinado por uma pessoa que tenha esse conhecimento, antes
de operar com este aparelho.”
“‘
”
Figyelmeztetés! A készülék meghibásodásának valamint a kezelö
sérülésének megelözése érdekében a felhasználónak feltétlenül
értenie kell az angol nyelvet, ezen belül a müszaki kifejezéseket,
vagy pedig a használatba vételt megelözöen a készülék kezelésében
már gyakarlott személy által történö betanitás szükséges!
С цел да избегне повреда на апаратурата или нараняване на
оператора е необходимо клиента добре да владее английски език и
техчническата терминолгия, която е използувана в описанието
или да бъде обучен от лице, което е вече работило с такъв апарат.

EXPLOSION WARNING
iv
EAR99 Technology Subject to Restrictions Contained on the Cover Page
EXPLOSION WARNING
WARNING
Teledyne ISCO SyriXus syringe pumps are
NOT EXPLOSION PROOF.
Teledyne ISCO SyriXus Syringe Pump Safety Note When Using a Flammable Fluid
The Teledyne ISCO syringe pumps must be placed within a properly operating vent hood (fume cup-
board), when using any flammable liquid at elevated temperatures, or ethane or any other flam-
mable gas. Ensure that all fluid handling connections are completely free of any gas leaks by
performing the leak test using CO2(for leak test procedures, refer to Technical Bulletin TB05 Field
Verification Procedures which can be found at https://www.teledyneisco.com/en-us/pumps/tech-
nical-bulletins). There must absolutely be NO gas leaks present before introducing the flammable
vapor. The flow rate, as registered by the pump, should settle to a value below 0.01 mL/min after 15
minutes during a static extraction in a temperature stable, leak-free system.
Important: When using flammable fluids with the Teledyne ISCO SyriXus syringe
pumps, ensure that proper safety precautions are followed, and that adequate ventilation
is always provided around the pump.
The Teledyne ISCO SyriXus syringe pumps use brush-type drive motors. Minor modifications to the
pumps may render them safer, especially in the rare event of catastrophic piston seal failure.
However, these modifications will not make these pumps explosion proof.
Remove the front and back cylinder covers located on the ball screw tower. This will allow any
escaped gas to quickly dissipate away from the pump cylinder area and to reduce the amount
entering the motor compartment.
Seal the syringe pump motor compartment with tape and purge the pump lower cabinet with a con-
tinuous flow of nitrogen (N2) gas. This will also reduce the possibility of accumulating anexplosive
mixture around the motor and relays.
For further information, consult the Teledyne ISCO Customer Service Department using the contact
information in Section 9.3 "Customer Service Department".
ATTENTION: Teledyne ISCO does not recommend or support the use of the SyriXus
syringe pumps with any flammable gas.
USE THE Teledyne ISCO SyriXus SYRINGE PUMPS IN THESE POTENTIALLY HAZ-
ARDOUSAPPLICATIONS AT YOUR OWN RISK!

AVERTISSEMENT
v
EAR99 Technology Subject to Restrictions Contained on the Cover Page
AVERTISSEMENT
Les pompes SyriXus Teledyne ISCO ne sont
pas antidéflagrantes.
Note de sécurité sur les pompes seringues SyriXus Teledyne ISCO lors de l'utilisation
d'un liquide inflammable
Les pompes seringues Teledyne ISCO doivent être placées dans une hotte ventilée (sorbonne)
fonctionnant correctement, lors de l'utilisation de tout liquide inflammable à des températures
élevées, ou d'éthane ou de tout autre gaz inflammable. Assurez-vous que toutes les connectiques sont
complètement exemptes de toute fuite de gaz en effectuant le test de fuite à l'aide de CO2(Cette
méthode est détaillée dans le bulletin technique TB05 Field Verification Procedures que vous pouvez
trouver sur le lien https://www.teledyneisco.com/en-us/pumps/technical-bulletins). Il faut absol-
ument qu'il n'y ait AUCUNE fuite de gaz avant d'introduire le gaz inflammable. À partir d’un
système à température stable et sans aucune fuite de gaz, le débit, tel qu'enregistré par la pompe,
doit se stabiliser à une valeur inférieure à 0,01 ml/min après 15 minutes lors d'une extraction sta-
tique.
Important: Lors de l'utilisation de fluides inflammables avec les pompes seringues
SyriXus Teledyne ISCO, assurez-vous que les bonnes précautions de sécurité sont prises
et qu'une ventilation adéquate est toujours assurée autour de la pompe.
Les pompes seringues de la série SyriXus Teledyne ISCO utilisent des moteurs à charbon. Des modi-
fications mineures apportées aux pompes peuvent les rendre plus sûres, en particulier dans les rares
cas de défaillance catastrophique du joint de piston. Cependant, ces modifications ne rendront pas
ces pompes antidéflagrantes.
Retirez les couvercles du cylindre avant et arrière situés autour de la vis sans fin à billes. Cela per-
mettra à tout gaz échappé de se dissiper rapidement de la zone du cylindre de la pompe et de réduire
la quantité entrant dans le compartiment moteur.
Scellez le compartiment moteur de la pompe seringue avec du ruban adhésif et purgez la partie
inférieure de la pompe avec un flux continu d'azote (N2). Cela réduira également la possibilité
d'accumuler un mélange explosif autour du moteur et des cartes électroniques.
Pour toute information supplémentaire, consulter le Service Clients de Teledyne ISCO en utilisant
les informations données dans le chapitre 9.3 "Service Clients".
Pour l'information supplémentaire, consulter le département de service technique 9.3
"Customer Service Department".
ATTENTION : Teledyne ISCO ne recommande ni ne prend en charge l'utilisation des
pompes seringues SyriXus avec des gaz inflammables.
UTILISER LES POMPES SERINGUES Teledyne ISCO SyriXus DANS CES APPLICA-
TIONS POTENTIELLEMENT DANGEREUSES EST À VOS PROPRES RISQUES !

Supercritical Fluid Extraction Laboratory Staff - Warning to Users
vi
EAR99 Technology Subject to Restrictions Contained on the Cover Page
Supercritical Fluid Extraction Laboratory Staff - Warning to Users
WARNING: PLEASE READ
At the request of our Supercritical Fluid Extraction laboratory staff, we want our cus-
tomers to be aware of the potential hazards involved with supercritical fluid extraction.
Oxidizing gases, such as nitrous oxide, in contact with organic matrices or flammable modifiers, can
detonate under certain conditions. Likewise, flammable fluids, such as methane, under high
pressure conditions can present a hazard.
With concern for the safety of our customers, we have designed our equipment to be as safe as pos-
sible. However, we do not recommend the use of our instrument with potentially explosive reactions.
The letter below, which appeared in the July 22, 1991 edition of Chemical and Engineering News, is
reprinted with permission from Professor Robert E. Sievers and his colleagues at the University of
Colorado at Boulder. Even though they were not performing supercritical fluid extraction, it details
the problems their lab experienced using nitrous oxide under similar conditions. We add our support
for their suggestion to use only carbon dioxide or other less hazardous fluids for supercritical fluid
extraction.

Instrument Use Warnings and Cautions
vii
EAR99 Technology Subject to Restrictions Contained on the Cover Page
Instrument Use Warnings and Cautions
CAUTION:
Avoid spills! Liquids associated with this instrument may be clas-
sified as carcinogenic, biohazardous, flammable, or radioactive.
Should these liquids be used, it is highly recommended that this
application be accomplished in an isolated environment designed
for these types of materials in accordance with federal state and
local regulatory laws and in compliance with your organization’s
chemical/hygiene plan in the event of a spill.
In all cases, when using Teledyne ISCO instrumentation, prudence
and common sense must be used.
WARNING:
Pinch point. This symbol warns you that your fingers or hands will
sustain serious injury if you place them between the moving parts
of the mechanism near this symbol.
WARNING:
Avoid hazardous practices! If you use this instrument in any way
not specified in this manual, the protection provided by the
instrument may be impaired; this will increase your risk of injury.
CAUTION:
Liquids associated with this instrument may be classified as car-
cinogenic, biohazardous, flammable, or radioactive. Should these
liquids be used, it is highly recommended that this application be
accomplished in an isolated environment designed for these types
of materials, in accordance with federal, state, and local regulatory
laws, and in compliance with your company’s chemical/hygiene
plan in the event of a spill.
In all cases, when using Teledyne ISCO instrumentation, prudence
and common sense must be used.
WARNING:
Team lift. To reduce the risk of injury do not attempt to lift this
instrument independently. It is highly recommended that a team be
used when lifting this instrument.
AVIS:
Éviter de répandre! Les liquides qui sont pompés dans cet
instrument peuvent être cancérigènes, hasards biologiques, inflam-
mables, ou radioactifs. Si vous devez utiliser ces liquides
hasardeux, il est très recommandé que vous le faites à l'intérieur
d'un environnement isolé conçu pour tels liquides. Cet envi-
ronnement isolé devrait être construit selon les règlements
fédéraux, provinciaux, et locaux, aussi que le plan de votre organi-
sation qui concerne l'évènement d'un accident avec les matières
hasardeuses. En tout cas, utilisez toujours l'instrumentation d'Isco
avec prudence et sens commun.

Instrument Use Warnings and Cautions
viii
EAR99 Technology Subject to Restrictions Contained on the Cover Page
ATTENTION:
Risque de pincement. Ce symbole vous avertit que les mains ou les
doigts recevront une blessure sérieuse si vous les mettez entre les
éléments en mouvement du mécanisme près de ce symbole.
ATTENTION:
Éviter les usages hasardeux! Si vous utilisez cet instrument d’une
manière autre que celles qui sont specifiées dans ce manuel, la pro-
tection fournie par l’instrument peut être affaiblie; cela aug-
mentera votre risque de blessure.
AVIS:
Les liquides qui sont analysés dans cet instrument peuvent être
cancérigènes, hasards biologiques, inflammables, ou radioactifs.
Si vous devez utiliser ces liquides hasardeux, il est très recom-
mandé que vous le faites à l'intérieur d'un environnement isolé
conçu pour tels liquides.
Cet environnement isolé devrait être construit selon les règlements
fédéraux, provinciaux, et locaux, aussi que le plan de votre organi-
sation qui concerne l'évènement d'un accident avec les matières
hasardeuses.
En tout cas, utilisez toujours l'instrumentation d'Isco avec pru-
dence et sens commun.
AVERTISSEMENT:
Ascenseur d’équipe. Pour réduire le risque de blessure, n’essayez
pas de soulevez cet instrument indépendamment. Il est fortement
recommandé qu’un équipe être utilisé lors du levage de cet
instrument.

Commonly Ordered Replacement Parts for the SyriXus Series Syringe Pumps
ix
EAR99 Technology Subject to Restrictions Contained on the Cover Page
Commonly Ordered Replacement Parts for the SyriXus Series Syringe
Pumps
Pre-Assembled Tubing Assemblies for SyriXus Series Syringe Pumps
Part Model Description P/N
Cylinder Seals General 65x 0-1379 bar 202-9096-08
260x 0-655.0 bar 202-9091-06
500x 0-344.7 bar 202-9091-56
1000x 0-137.8 bar upper seal 202-9990-25
1000x 0-137.8 bar lower seal 202-9990-23
Inlet/Outlet Fittings 65x 1/4” F250C Gland 209-0164-02
1/4” F250C Collar 209-0164-03
260x Valco - 1/8” Nut 209-0169-27
1/16” Nut 209-0094-07
1/8” Plug 209-0166-80
1/8” – 1/16” Tubing Reducer 209-0169-42
500x 1/8” Tubing Connector to 1/8” NPT 209-0161-01
1000x 1/4” NPT Plug 209-0168-09
Model Description P/N
65x Air Valve Tubing 209-0166-71
Air Valve Collar 209-0164-03
Air Valve Gland Nut 209-0164-02
260x Air Valve 60-1268-030
Electric Valve 60-1268-033
500x Air Valve 60-1268-031
Electric Valve 60-1268-032
500xv Air Valve 69-1263-360
(tubing only)
1000x Air Valve 60-1268-048
Electric Valve 60-1268-046

Pre-Assembled Tubing Assemblies for SyriXus Series Syringe Pumps
x
EAR99 Technology Subject to Restrictions Contained on the Cover Page
Intentionally Left Blank

TOC-I
EAR99 Technology Subject to Restrictions Contained on the Cover Page
SyriXus Series Pumps Installation and Operation Guide
Table of Contents
Section 1 Introduction
1.1 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.3 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1.4 Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1.5 Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
1.5.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
1.6 Preliminary Checkout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18
Section 2 Fluid System Connections and Accessories
2.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2 Fluid System Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2.1 Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2.2 Installation Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2.3 Tubing Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.4 Installing the 65x Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.2.5 Draining Overflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.2.6 Cylinder Washing - Wash Gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.2.7 Cylinder Washing - Nitrogen Purge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.2.8 Flushing Pumps with External Transducers . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.3 Fluid Connection Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.3.1 Manual Refill Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.3.2 Manual Outlet Valve Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
2.4 Temperature and Pressure Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
2.4.1 Temperature Control Jacket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
2.4.2 Removing the Pump Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
2.4.3 Using the Wrench Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
2.4.4 Installing the Temperature Control Jacket . . . . . . . . . . . . . . . . . . . . . . . . 2-14
2.5 Seal Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Section 3 Basic Programming and Operation
3.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2 General Controller Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2.1 Controller Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2.2 Rates, Units, and Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.2.3 Programming Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.2.4 Run Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.2.5 Selecting Operating Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.3 Main Menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.4 Menu One . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.4.1 Flow and/or Pressure Units of Measure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.4.2 Pump Selection
(if Multiple Pumps) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.4.3 Refill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3.4.4 Power Failure [STOP] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3.4.5 System Reset (Restore Default Settings) . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3.4.6 Display Contrast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3.5 Menu Two . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3.5.1 Serial Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3.5.2 Pump Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8

TOC-II
EAR99 Technology Subject to Restrictions Contained on the Cover Page
3.5.3 External Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3.5.4 Multiple Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3.5.5 Total Volume Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3.5.6 Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3.6 Menu Three . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3.6.1 Poor Fill Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3.6.2 Diagnostic Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3.6.3 Pressure Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3.6.4 Diff. Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3.6.5 Pressure Integral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3.6.6 Pressure Deadband . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3.7 Menu Four . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3.7.1 Modbus Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3.8 Front Panel Keys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.8.1 CONST PRESS and CONST FLOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.8.2 PRGM GRAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.8.3 HOLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.8.4 RECALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.8.5 STORE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.8.6 REFILL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.8.7 LIMITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.8.8 RAPID PRESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
3.8.9 DISP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
3.8.10 ACC CTRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
3.8.11 ZERO PRESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
3.9 Control of Multiple Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
3.9.1 Multi-Pump Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
3.9.2 Independent Control of up to Four Separate Pumps . . . . . . . . . . . . . . . . . 3-17
3.10 Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
3.10.1 Constant Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
3.10.2 Constant Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19
3.10.3 Dispense Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3.11 External Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.12 External Control - Analog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.12.1 Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
3.12.2 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
3.12.3 External Control for Refill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.12.4 Calculation Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3.12.5 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24
3.13 Remote RUN/STOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24
3.13.1 Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24
3.14 Analog Flow Rate and Volume Output Options . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3.14.1 Voltage Analog Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3.14.2 Current Loop Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
Section 4 Gradient Pumping for Pressure, Flow, and Concentration
Modes
4.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1.1 Tools and Parts for Single-Pump System . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1.2 Tools and Parts for Dual-Pump System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.2 Connecting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.2.1 Inlet Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.2.2 Outlet Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.2.3 Dual-Gradient System Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.3 Single-Pump Gradient Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
4.4 Dual-Pump Concentration Gradient Programming . . . . . . . . . . . . . . . . . . . . . . . . 4-9
4.5 Review, Revise, & Hold Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11

TOC-III
EAR99 Technology Subject to Restrictions Contained on the Cover Page
4.6 Program Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Section 5 Continuous Flow Introduction, Installation, and Opera-
tion
5.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2 Continuous Flow Air Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2.1 Continuous Flow Air Valves Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
5.2.2 Air Valve Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
5.3 Continuous Flow Electric Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
5.3.1 Continuous Flow Electric Valves Overview . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
5.3.2 Electric Valve Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9
5.4 User
Supplied Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
5.5 Continuous Flow Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
5.5.1 Defining Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
5.5.2 Constant Flow Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5.5.3 Constant Pressure Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5.5.4 No Check Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16
5.5.5 To Run or Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
5.5.6 Tips for Running Continuous Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
Section 6 Modifier Addition
6.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
6.1.1 Example of Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6.1.2 Two Independent Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6.1.3 Continuous Flow System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6.1.4 Modifier Mode Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
6.1.5 Two-Pump Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6.2 Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
6.2.1 Minimum Modifier Pressure Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
6.2.2 Modifier Concentration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
6.3 Refilling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
6.3.1 Refill the CO2Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
6.3.2 Refill Pump B (the Modifier Pump) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
6.3.3 Start Modifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
Section 7 Modbus Configuration
7.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
7.1.1 Modbus RTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
7.1.2 Modbus TCP/IP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.1.3 Modbus Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Section 8 Serial Interface
8.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
8.2 Network Control and
Communication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
8.3 USB Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8.4 Cabling for Serial Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8.4.1 One Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
8.4.2 Two
Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
8.4.3 Three or More Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5
8.5 Serial Control Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.6 Controller Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6

TOC-IV
EAR99 Technology Subject to Restrictions Contained on the Cover Page
8.6.1 Restore Defaults (If Desired) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.6.2 Change Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
8.6.3 Verify Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8.7 User-Written Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8.7.1 DASNET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8.7.2 Universal Driver from Teledyne ISCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8
8.8 Serial Commands for the SyriXus Series Pumps . . . . . . . . . . . . . . . . . . . . . . . . . 8-20
8.8.1 Get Status Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-26
8.8.2 Gradient Download Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-30
8.8.3 Gradient Upload Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-30
8.8.4 Range Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-34
8.8.5 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-35
Section 9 Pump Maintenance, Troubleshooting, and Servicing
9.1 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
9.2 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.3 Customer Service Department . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.4 General Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3
9.5 Resetting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4
9.5.1 Basic Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4
9.5.2 Hard Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4
9.6 Diagnostic Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4
9.6.1 LCD TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4
9.6.2 ANALOG INPUTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5
9.6.3 KEYPAD TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5
9.6.4 MOTOR CONTROL/LIMITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5
9.6.5 SERIAL TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-7
9.7 Removing the Case Top. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-8
9.7.1 Controller Case Top Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-8
9.7.2 Pump Case Top Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-9
9.8 Test Points. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-9
9.8.1 Power Supply (A1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-9
9.8.2 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10
9.9 Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10
9.9.1 Ball Nut . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11
9.10 Seal Cleaning and Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-11
9.10.1 Piston Seal
(Excludes 30D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-13
9.10.2 Piston Seal Break-In (Aqueous Seals Only) . . . . . . . . . . . . . . . . . . . . . . . 9-13
9.10.3 All Other Piston Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-14
9.10.4 Wiper Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-14
9.11 Wear Ring Cleaning and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-15
9.12 Flushing the Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-16
9.12.1 Gas Solvent Changeover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-16
9.12.2 Liquid Solvent Changeover and Flushing . . . . . . . . . . . . . . . . . . . . . . . . 9-16
9.13 Overpressure
Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-17
9.13.1 Shear Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-18
9.13.2 Replacement Using Installation Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-19
9.13.3 Replacement
Without Installation Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-20
9.13.4 Completion of Shear Key Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . 9-20
9.14 Motor Brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-21
9.14.1 Motor Brush Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-23
9.15 Calibrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24
9.15.1 Pressure Transducer Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24
9.15.2 A/D Circuit Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24

TOC-V
EAR99 Technology Subject to Restrictions Contained on the Cover Page
9.15.3 Limit Sensor Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24
9.15.4 Limit Sensor Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-27
9.15.5 Electric Valve Motor
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-28
List of Figures
1-1 260x flow rate range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1-2 500x and 500xv flow rate range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1-3 1000x flow rate range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
1-4 Pump controller key functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1-5 Pump controller rear panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
1-6 Pump rear panel connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
1-7 Pump front panel controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
1-8 Syringe pump cylinder cap: Attach to pressure
transducer connector on back of pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17
1-9 Connecting the pump and controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17
1-10 Status Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18
1-11 Menu 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
1-12 Three pump stop menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19
1-13 Four pump stop menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20
2-1 Liquid system plumbing connections (65x on left) . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2-2 SyriXus 65x Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2-3 Drain tube installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2-4 Drain tube installation and wash gland connection . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2-5 Purge connector installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2-6 Refill kit installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
2-7 Outlet valve package connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
2-8 System with temperature control jacket installed . . . . . . . . . . . . . . . . . . . . . . . . 2-11
2-9 Secure screws with the 1/4” hex wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
2-10 Temperature control jacket installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
2-11 Inside the pump cylinder: wetted materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17
3-1 Menu 1 program selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3-2 Units menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3-3 Menu 2 program selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3-4 Serial option menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3-5 Total volume reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3-6 Types of valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
3-7 Menu 3 program selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3-8 Location of transducer midpoint value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3-9 Limits menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
3-10 Limits setpoint (Max Press) menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
3-11 Depiction of dispense mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20
3-12 External control for refill menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
3-13 Button sequence for external control setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24
3-14 Analog voltage output connection, rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3-15 Output range selection jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
4-1 Two-way valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4-2 Pump inlet connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4-3 Pump outlet connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4-4 Dual-gradient system connections
(Inlet valves (A & C) are from refill valve kits) . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
4-5 Dual-gradient connection detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
5-1 Controller Accessory Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5-2 Actuator wire labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
5-3 Electric valve installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
5-4 Keystrokes to specify valve type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
5-5 Keystrokes to reset volume totalizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14

TOC-VI
EAR99 Technology Subject to Restrictions Contained on the Cover Page
5-6 Keystrokes to set up constant flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5-7 Keystrokes to set up constant pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5-8 No Check Valve Setting to ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
5-9 Keystrokes to Run or Stop the pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18
6-1 Modifier addition components installation (Two-pump configuration) . . . . . . . . . 6-2
6-2 Modifier addition kit installation (continuous flow) . . . . . . . . . . . . . . . . . . . . . . . . 6-3
6-3 Minimum modifier pressure screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
7-1 RS-485 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
8-1 Serial network connection example - Single connection . . . . . . . . . . . . . . . . . . . . 8-4
8-2 Serial network connection example - dual connection . . . . . . . . . . . . . . . . . . . . . . 8-5
8-3 Get status string ‘G’ command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-26
8-4 Get status string ‘GG’ command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-27
8-5 Get all status string ‘G&’ command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-28
8-6 Get all status strings from four pump operation ‘G&2’ command . . . . . . . . . . . . 8-29
8-7 Gradient download commands - single-pump flow gradient . . . . . . . . . . . . . . . . 8-30
8-8 Gradient download commands - two-pump flow gradient . . . . . . . . . . . . . . . . . . 8-31
8-9 Gradient upload commands - single-pump flow gradient . . . . . . . . . . . . . . . . . . 8-32
8-10 Gradient upload commands - two-pump flow gradient . . . . . . . . . . . . . . . . . . . 8-33
8-11 Upload commands - single-pump pressure programming . . . . . . . . . . . . . . . . . 8-33
8-12 Range serial commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-34
9-1 Accessing the diagnostic menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4
9-2 Analog input diagnostic screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5
9-3 Optical sensor, interrupted by flag (bottom sensor
shown, rear tower cover plate removed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6
9-4 Serial connection to a computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-7
9-5 Controller case top screws (2 of 4 shown) - TBD . . . . . . . . . . . . . . . . . . . . . . . . . . 9-8
9-6 Pump case top screws (3 of 6 shown) - TBD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-9
9-7 Gear train lubrication and motor drive service . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10
9-8 Cylinder lock screw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12
9-9 Break-in procedure for aqueous seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-14
9-10 Accessing the shear key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-18
9-11 Shear key replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-19
9-12 Shear key installation tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-19
9-13 SyriXus series motor brush replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22
9-14 Location of motor brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22
9-15 Length of a new motor brush (1.1 cm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-22
9-16 Inserting new motor brush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-23
9-17 Limit sensor replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-26
9-18 Installing the plastic mounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-26
9-19 Electric valve motor voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-28
9-20 Electric valve motor adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-29
List of Tables
1-1 65x Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1-2 260x Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1-3 500x Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1-4 500xv Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1-5 1000x Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1-6 Pump Controller Front Panel Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9
1-7 Pump Controller Key Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
1-8 Pump Controller Rear Panel Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11
1-9 Pump Rear Panel Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
1-10 Pump Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
1-11 Cable Part Numbers and Lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
2-1 Standard Port Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2-2 Manual Refill Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
2-3 Manual Outlet Valve Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10

TOC-VII
EAR99 Technology Subject to Restrictions Contained on the Cover Page
2-4 Temp. Control Jacket Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
2-5 Wetted Materials in SyriXus Series Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17
2-6 Seal Selection Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
3-1 SyriXus Series Controller to D Series Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3-2 D Series Controller to SyriXus Series Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3-3 Key Functions in the Multi-Pump Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
3-4 Analog Output Options (Connections to Female 25 Pin Sub-D) . . . . . . . . . . . . . 3-26
3-5 Analog Output Signal/Sub-D Pins for 4-20mA . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27
3-6 Analog Output Signal/Sub-D Pins for 0-10 VDC . . . . . . . . . . . . . . . . . . . . . . . . . 3-28
4-1 Manual Refill Valve Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4-2 Manual Outlet Valve Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4-3 Swaging Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
5-1 Air Valve Package Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5-2 Continuous Flow Technical Specifications-Air Valves . . . . . . . . . . . . . . . . . . . . . . 5-2
5-3 ALL Dual Air SyriXus Pumps -
Conversion Table for A-B Pump Pair and C-D Pump Pair . . . . . . . . . . . . . . . . . . 5-6
5-4 Electric Valve Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
5-5 Continuous Flow Technical Specifications - Electric Valves . . . . . . . . . . . . . . . . . 5-8
5-6 Accessory Control Digital Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
5-7 Key Functions in the Multi-Pump Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
7-1 Modbus TCP/IP Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7-2 Modbus TCP/IP Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7-3 Modbus RTU Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7-4 Supported Modbus Function Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7-5 Exception Responses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7-6 Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7-7 Holding Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
8-1 External Control Connector Serial Pin Connections . . . . . . . . . . . . . . . . . . . . . . . 8-2
8-2 USB Interface Pin Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
8-3 Serial Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-20
8-4 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-35
9-1 Replacement Shear Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-18

TOC-VIII
EAR99 Technology Subject to Restrictions Contained on the Cover Page
Intentionally Left Blank
This manual suits for next models
4
Table of contents
Other Teledyne Water Pump manuals
Popular Water Pump manuals by other brands

Teryair
Teryair DP 75 AL N Operation and maintenance guide

Conrad Electronic
Conrad Electronic 55 12 20 operating instructions

Xylem
Xylem FLYGT Concertor Installation, operation and maintenance manual

Desmi
Desmi SA50-T HATZ 1B20 Operation and maintenance instructions

SKF
SKF Lincoln GTP-C Original operating instructions

Agilent Technologies
Agilent Technologies PHV K Series Operating and maintenance instructions